Loading...
PMT17-01234 City of Menifee Permit No.: PMT17-01234 29714 HAUN RD. SnCCEL/-> MENIFEE, CA 9258E Type: Residential Electrical evs"^—AWft.'° MENIFEE Date Issued: 0 510 5/2 01 7 PERMIT Site Address: 29602 EDGEMERE WAY, MENIFEE, CA Parcel Number: 364-360-050 92584 Construction Cost: $6,328.72 Existing Use: Proposed Use: Description of SOLAR TR 30422-3 MARIPOSA Work: 9 MODULES,2.39KW LOT 214 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA,CA 92879 ATTN GOREEN MUELLER Applicant Phone:9493498269 JEREMIAH ACAYTURRI License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO,CA 92656 Fee Description OOrt Amount lE1 Solar,Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing building operations being carried on thereunder when In violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bidg_Permil_Templale.rpt Page 1 of 1 .,,wsxe BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION Menifee DATE PERMIT/PLAN CHECK NUMBER TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL MULTI-FAMILY ❑MOBILEHOME POOL/SPA ❑SIGN SUBTYPE: ❑✓ ADDITION []ALTERATION [—]DEMOLITION ❑ELECTRICAL ❑MECHANICAL [-]NEW [-]PLUMBING ❑RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit-Plan 2129-2.39 kW/9CS Master Solar Permit No.:PMT16-00910 PROJECTADDRESS 29602 Edgemere Way,Menifee, CA 92584 ASSESSOR'S PARCEL NUMBER 36% -36Q —'OsnOT 214 TRACT 30422-3 PROPERTY OWNER'S NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,suite 302,Corona, CA 92879 PHONE (951)817--3680 EMAIL jeremiah.acayturri@lennar.com APPLICANT NAME Lennar Homes of California,Inc. ADDRESS 980.Montecito:Dr.,.suite3.02,.Corona,CA92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? ❑✓ YES❑NO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA.92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ $6,328.72 L SO,FT APPLICANT'S SIGNATURE DATE 04/06/2017 CITY STAFF USE ONLY DEPARTMENT DISTRIBUTION ,[► CITY OF MENIFEE BUSINESS LICENSE NUMBER BURRING PLANNING ENGINEER G FIRE GREEN SMIP INVOICE " PAIDAMOUNT AMOUNT OCASH OCHECK# OCREDIT CARD VISA/MC PLAN CHECK FEES PAID AMOUNT O CASH O CHECK# O CREDIT CARD VISA/MC OWNER BUILDER VERIFIED OYES O NO DL NUMBER NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Department 29714 Houn Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-245-6213 SYSTEM INFORMATION ^ '✓ J BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MFR. MODEL Mike Dufault ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 12.38S KW 1 Sr VPOpennons LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 1 9 PCS.1 HYUNDAI I HIS-S265RG(265W) 1101001133 GassB BUYER: INVERTER .. l 9 PCS..l ENPHASE. I M2I5-60-2LL-S22-IG .1 _ ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: _ _— SUB-ARRAY INFORMATION ARRAY#I 1 ARRAY#2 ARRAY#3 MOD OTY 9 NA NA BUYER: NIFE TILT 23° 1 NA' I NA' AZIMUTH 175° 1 NA- I NA- DATE: ND RAFE PLAN APPROV City of Menitee 1 Building Dept REVIEWED BY MAY 0 3 2017 Approval of these plans sl all not approval of,any violation of any `' '' regulation.,and ordinance .This m A' e i �/ e d jobsite until completion. z --- -- - . z I a� LL I I l SOLADECK WIRE TRANSITION BOX i + (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE � UTILITY METER& O � MAIN SERVICE PANEL —— (VERIFIED BY BUILDER) L NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF N PLAN T2129 ATI ELEVATION A-RIGHT ORIENTATION 1 LO #2 4 ENNAR: ORIGINAL BY: KIM ABCOUWER I DATE:17.03.23 MARIPO&AREVIEWED'BY:JIM PARKS DATE:I].03.23 CORONNA,A,C CA AT THE LAKES 980 I DRIVE,#302 A 92879 REV.# BY DATE I DESCRIPTION �nama ud tee DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4511 Broatlway Street INDIVIDUAL 29602 EDGEMERE WAY BmIder,CO 80304 PLOT PLAN 1 1/I6-=1'-0' MENIFEE,CA 303.447.0300 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE,CA INV.MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INV. MODEL INVERTER SPEC M215-6D-2LL-S22-IG ., ..TEMP..AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -, ... 2 -..,, ,1' INV. MAX POWER,IWAC MAX) INVERTER SPEC WATTS(AC). 225. TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V.(Voc MAX) INVERTER SPEC VOLTS(Od 48 TEMP.DELTA LOW(TDELTA) THIN-TTEST °C -27 INV. OUTPUT V,(VAC NOM) INVERTER SPEC VOLTS(AC) 240 MOD. MANUFACTURER MODULE SPEC HYUNDAI INV. OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD. PART NUMBER MODULE SPEC HIS-S265RG INV.OUTPUT CURRENT,IAC INVERTER SPEC AMPS(AC) 0.9 MOD. POWER STC(P) MODULE SPEC WATTS(DO 265 INV. PHASE QUANTITY INVERTER SPEC PHASE I MOD. POWER PTC MODULE SPEC WATTS(Bc) 238 COMPLIANCE INVERTER SPEC UL17411JEEE1547 MOD. OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(DO 31.30 INV.GROUNDING INVERTER SPEC ISOLATED EPA MOD.OPEN CCT.VOLTAGE(Vac) MODULE SPEC VOLTS(oc) 38.10 INV. OTY,MAX/BRANCH CCT. INV,OTYBc OTY 9 MOD.COEFF. VOLT/TEMP(CLEF) MODULE SPEC V/°C -0.114 BRANCH CCT.OUTPUT,IMAXBC I (IAC•INV.GTYec) I AMPS(A[) 1 8.10 MOD.MAX VOLTAGE(VMAXMO9) (Voc♦(TOCOEF)) VOLTS(OC) 41.18 INV. QUANTITY,TOTAL I INV.OTYT I CITY 1 9 MOD.OPERATING CURRENT(IMP) MODULE SPEC AMPS(DC) 8,50 TOTAL SYSTEM OUTPUT,IMAXTS (IAC-INV.GTYT) AMPS(AC) 8.10 MOD.SHORT CCT.CURRENT(Isc) MODULE SPEC AMPS(DO 9.00 MOD.MAXIMUM CURRENT OMAX) (ISC• 1.25) AMPS(DO 11.25 MIN.AMPACITY REO'D,PER NEC (IMAX•1.25) AMPS(DC) 14.06 SERIES FUSE RATING,MAX MODULE SPEC AMPS(BC) 15 ELECTRICAL EQUIPMENT SCHEDULE (medtl KEY CITY MANUFACTURER MODEL NOTES TRADE ui nS Oft 1 9 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR pr0va 2 9 ENPHASE M21S-60-2LL-S22-IG PV INVERTER SOLAR 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 4 1 CUTLER-HAMMER OG221URB PV AC DISCONNECT,NEMA 3R,240V.30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR 8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS:I X I5A-IP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBD PV BREAKER, I X 20A-2P.LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 1 TBD TBD SERVICE PANEL.MIN. 125A BUS BLDR.El EC. II I TBD TBO UTILITY METER, MIN. 120/24OV,200A BLDR.ELEC. 12 I TBD TBD GROUNDING ELECTRODE UFER BLDR.ELEC. 13 1 I 1 TBD I TBD GROUNDING ELECTRODE.690.47(D) SOLAR CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS 1)CONDITION OF USE(COU): (AMPACITY• TEMP.DERATE•FILL DERATE) vs. REO'D(IMAX) ITEM JAMPS PANEL 2)TERMINALS(TERM): AMPACITY AT TERMINALS. VS.REC'D,(IMAX• 1.25) PANEL HER. CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALC' AMPACITY W/0 TEMP. FILL RESULT REO'D OCD BUS RATING 200 TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT 200 A #12 CU THWN-2 COU 30 0.76 1.0 22.80 8.10 ALLOWED PV PER NEC 40 TERM 25 25 10.13 20 PV OCPD DEVICE USED 20 B #10 CU NM-B COU 40 0.91 1.0 36.40 8.10 TERM 35 35 IO.13 20 ^ C #10 CU NM-B COU 40 0.91 1.0 36.40 8.10 ✓ TERM 35 35 10.13 20 M eik Duhult CONDUCTOR SCHEDULE Sr VPOwmdGns KEY CONDUCTORS CU/AL TYPE LOCATION TRADE Uc#1001133 OwB A 1-#12 ENGAGE CABLE,h#6G,FREE AIR CU TC-ER ARRAY SOLAR B 3-#10, 1-#10 EGC CU NM-B(ROMEX) INTERIOR SOLAR C 3-#10, 1-#10 EGC CU NM-B(ROMEX) INTERIOR SOLAR D CATSE.ETHERNET CABLE CU CATSE INTERIOR SOLARA14 E 1-#6GEC.2010 CEC 690.47(D) CU BARE EXTERIOR SOLARG 13 = E A B. I I I ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.385 KW LOT#214 LENNAR: ORIGINAL BY: KIM ABCOUWER DATE:17.03.23 MARIPOSA REVIEWED BY:JIM PARKS DATE:17.03.23 CORONA,CA AT THE LAKES 980 NA,CAI2 DRIVE;u302 92879 REV.# BY DATE DESCRIPTION Gta namaste SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: treet INDIVIDUAL 4571 ear,CO 3M PLOT PLAN 2 NTS MENIF EOGEMERE WAY Ba3M. CO80304 ELECTRICAL MENIFEE,CA 303.4A7.0300 STRUCTURAL NOTES: Mike 0utaul[ SOLAR CONTRACTOR- Sr VP Opeotlons 1)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. U01001193 ClassB 2)ALL PV ROOF ATTACHMENTS WILL.BE.STAGGERED,�,Y ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT.POSSIBLE. .. _ 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL,VERSION 227.3.PUB 140113-ICC,JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(1')SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(2-)BEYOND THE EDGE NT OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. ROOFING CONTRACTOR- 1)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(Y)OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF SAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. .1 p nail CD 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE.BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO I< al,state 1 INSTALLATION. u151 EC k ELECTRICAL NOTES: GENERAL- 1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/GEL. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE 1.1-1703,IEC61646, IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. M)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT t. 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. LENNAR: ORIGINAL BY: KIM ABCOUWER DATE:17.03.23 MARIPOSA REVIEWED BY: JIM PARKS DATE:17.03.23 AT THE LAKES 9B0 CORONNA.A.MON C CA DRIVE,#302 A 92879 REV.;< BY GATE DESCRIPTION u namasbe acsee DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Bmadway Saeet INDIVIDUAL - 29602 EDGEMERE WAY Boulder,CO 803M PLOT PLAN 3 NTS MENIFEE.CA 303A47.0300 NOTES Mike Default Se VPOperattons Uc#1001133 Class B CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. W SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER 8 MAIN SERVICE PANEL (VERIFIED BY BUILDER) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: 8J A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION LENNAR: ORIGINAL BY: KIM ABCOUWER DATE:17.03.23 MART POS'A REVIEWED980 MONTECITO DRIVE,#302 'BY:JIM PARKS DATE:17.03.23 AT THE LAKES CORONA.CA 92879 REV.# BY DATE DESCRIPTION Qto namastd DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 45T1lde tlCOd8 304 29fi02 EOGEMERE WAY Boulder, 7030306 PLOT PLAN 4 NTS MENIFEE,CA 303.447.0300 PLACARDS