PMT17-01232 City of Menifee Permit No.: PMT17-01232
29714 HAUN RD.
�CCEL/-> MENIFEE,CA 92586 Type: Residential Electrical
MENIFEE Date Issued: 05/05/2017
PERMIT
Site Address: 29578 EDGEMERE WAY, MENIFEE,CA Parcel Number: 364-360-048
92584 Construction Cost: $6,328.72
Existing Use: Proposed Use:
Description of SOLAR TR 30422-3 MARIPOSA
Work: 9 MODULES,2.39KW
LOT 212
Owner Contractor
LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC
980 MONTECITO DR#302 25 ENTERPRISE
CORONA,CA 92879 ATTN GOREEN MUELLER
Applicant Phone:9493498269
JEREMIAH ACAYTURRI License Number:728102
LENNAR HOMES OF CALIFORNIA INC
25 ENTERPRISE
ATTN GOREEN MUELLER
ALISO VIEJO, CA 92656
Fee Description (Ql( Amount lSl
Solar,Residential or Small Commercial 1 252.00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 1.00
General Plan Maintenance Fee-Electrical 1 12.60
$293.60
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors In the plans and
specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bldg Permit_Template.rpt Page 1 of 1
BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION
"I'Meniiee i `�—
DATE PERMIT/PLAN CHECK NUMBER
TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILEHOME ❑POOL/SPA ❑SIGN
SUBTYPE: ❑✓ ADDITION ❑ALTERATION []DEMOLITION ❑ELECTRICAL El MECHANICAL
❑NEW ❑PLUMBING [IRE-ROOF-NUMBER OF SQUARES
DESCRIPTION OF WORK Solar Permit-Plan 2129-2.39 kW/9CS
Master Solar Permit No.: PMT16-00910
PROJECT ADDRESS 29578 Edgemere Way, Menifee,CA 92584
ASSESSOR'S PARCEL NUMBER 36y -3GO-04/q LOT 212 TRACT 30422-3
PROPERTY OWNER'S NAME Lennar Homes of California, Inc,
ADDRESS 980 Montecito Dr.,suite 302,Corona,CA 92879
PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com
APPLICANT NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr.,suite 302,Corona,CA 92879
PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com
CONTRACTOR'S NAME Lerner Homes of California,Inc. OWNER BUILDER? ❑✓ YES.❑NO
BUSINESS NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879
PHONE (951)817-3680 EMAIL leremiah.acayturi@lennar.com
CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B
VALUATION$ $6,328.72 SQ L SO FT
APPLICANT'S SIGNATURE DATE 04/06/2017
CITYSTAFFUSE . . .. .. -.
AfLY
DEPARTMENT DISTRIBUTION 'Q CITY OF MENIFEE BUSINESS LICENSE NUMBER
BUILDING PLANNING ENGINEERING FIRE GREEN V- SMIP
INVOICE PAID AMOUNT
AMOUNT � JCASH 0CHECK# 0CREDIT CARD VISA/MC
PLAN CHECK FEES PAID AMOUNT p CASH 0 CHECK# O CREDITCARD VISA/MC
OWNER BUILDER VERIFIED OYES NO DL NUMBER NOTARIZED LETTER 0 YES 0 NO
City of Menifee.Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777
www.cityofinenifee.us Inspection Request Line 951-246-6213
SYSTEM INFORMATION I..,��,� BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED
ITEM OTY MFR. MODEL Mike Dufault ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE
SYSTEM SIZE 12.385 KW Sr VPOp"ti.m LOCATIONS INDICATED BY THE ILLUSTRATION.
MODULE 9PCS. HYUNDAI I HIS-S265RG(265W) Uc#1001133 Class B BUYER:
INVERTER... 9PCS.1 ENPHASE I M215-60-ZLL-S22-IG
ROOF TYPE I TILE Wit COMPOSITE SHINGLE UNDER ARRAY DATE:
SUB-ARRAY INFORMATION CITY OF MENMEE
ARRAY#I ARRAY#2 ARRAY#3 BUYER: III In DINE i ANT) SAF TY
MOD OTY 9 NA NA
TILT 23° NA' NM DATE: FLAN APPROV
AZIMUTH 264° NA' NA'
Aill-
City of Menifee R1:VIIEWEDe ki
Building Dept
MAY 0 '"!
3 ��s 51:punal+d these plans shall nc be cot
ulgnnral nf,aay violation of an provis
+rKulahnn.and nrdin:tnsxs.Thi sctof
E l eh c e i yr e (4 p:bsnc until complction.
16'-4' 3'
————_————_1 .>z
I
co l
_ I
I I
I I
I I
1 I
I I
SOLADECK WIRE
TRANSITION BOX
(UNDER ARRAY)
I I
PV
I
EX DISCONNECT
EXTEE RIOR-GARAGE
UTILITY METER 8
MAIN SERVILE PANEL ,
(VERIFIED BY BUILDER)
NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF N
PLAN TAT ELEVATION B-RIGHT
ORIENTATION I L
LENNAR: ORIGINAL BY: KIM ABCOUWER DATE:17.03.23
MARIPOSA '
980 MONTECITO DRIVE.#302 REVIEWED BY:JIM PARKS DATE:17.03.2-3
AT THE LAKES CORONA,CA 92679 REV.# BY DATE DESCRIPTION
Zinam=6
SULAR
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Br dt%,ay Street
INDIVIDUAL 29578 EDGEMERE WAY B..Weq CO 803M
PLOT PLAN 1 I/16'=1'-0' MENIFEE.CA 303A47.0300
SYSTEM LAYOUT
MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS
ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL
LOCATION MENIFEE,CA INV. MAKE INVERTER SPEC ENPHASE
TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% 'C 37 INV. MODEL INVERTER SPEC M215-60-2LL-S22-IG
._, .TEMP.AMBIENT LOW(TMIN) ASHRAE EXTR.MIN -C,.- .„... -2 ,... INV. MAX POWER,(WAC MAX) INVERTER SPEC WATTS,(Ad. 225
TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V,(Voc MAX) INVERTER SPEC VOLTS(oc) 48
TEMP,DELTA LOW(TOeLTA) THIN-TT[5T 'C -27 INV. OUTPUT V.(VAC NOM) INVERTER SPEC VOLTS(AC) 240
MOD. MANUFACTURER MODULE SPEC HYUNDAI INV. OUTPUT FREQUENCY INVERTER SPEC HERTZ 60
MOD.PART NUMBER MODULE SPEC HIS-S265RG INV. OUTPUT CURRENT,IAC INVERTER SPEC AMPS(AC) 0.9 . ART]
MOD. POWER STC(P) MODULE SPEC WATTS(oc) 265 INV. PHASE QUANTITY INVERTER SPEC PHASE 1
MOD.POWER PTC MODULE SPEC WATTS(cc) 238 COMPLIANCE INVERTER SPEC UL1741/IEEE1547
MOD. OPERATING VOLTAGE WHO MODULE SPEC VOLTS(DC) 31.30 INV. GROUNDING INVERTER SPEC ISOLATED
MOD. OPEN CCT.VOLTAGE(Vac) MODULE SPEC VOLTS(DC) 38.10 INV. OTY,MAX/BRANCH CCT. 1 INV.OTYac i QTY 19
MOD.COEFF. VOLT/TEMP(COEF) MODULE SPEC V/°C -0.114 BRANCH CCT. OUTPUT,IMAXBC I (IAC'INV.GTYBC) I AMPS(Ac) 18.10
MOD.MAX VOLTAGE(VMAXMOO) (VOc+(TB'COEF)) VOLTS(130 41.18 INV. QUANTITY,TOTAL I INV.OTYT I OTY 19
MOD.OPERATING CURRENT(IMP) MODULE SPEC AMPS(cc) 8.50 TOTAL SYSTEM OUTPUT,IMAXTB I OAC'INV.GTYT) I AMPS(Ac) 18.10
MOD.SHORT CCT.CURRENT(Isc) MODULE SPEC AMPS(Bc) 9.00
MOD.MAXIMUM CURRENT(IMAX) (Isc' 1.25) AMPS(cc) IL25
MIN.AMPACITY REG'D.PER NEC (IMAX' 1.25) AMPS(cc) 14.06 1. to be 1
SERIES FUSE RATING,MAX MODULE SPEC AMPS Old 15 T the Ca
ELECTRICAL EQUIPMENT SCHEDULE . 'ed plan
KEY OTY MANUFACTURER MODEL NOTES TRADE
1 9 HYUNDAI HIS-S265RG (265W) PV MODULE SOLAR
2 9 ENPHASE M215-60-2LL-S22-IG PVINVERTER SOLAR
3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR
4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R.240V,30A SOLAR
5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR
6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR
7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR
8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS:I X ISA-IP(ENVOY) SOLAR
9 NOTE CUTLER-HAMMER TBD PV BREAKER, I X 2OA-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR
10 1 TBD TBO SERVICE PANEL,MIN. 125A BUS BLDR.ELEC.
II TBD TBD UTILITY METER,IPH,120/24OV.200A BLAB.ELEC.
12 TBD TBD GROUNDING ELECTRODE UFER BLDR.ELEC.
13 1 1 1TBD 1 TED I GROUNDING ELECTRODE, 690.47(D) SOLAR
CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS
1)CONDITION OF USE(COU): I(AMPACITY'TEMP.DERATE-FILL DERATE) vs. REO'D(MAX) ITEM UNIT PANEL
2)TERMINALS(TERM): AMPACITY AT TERMINALS. vs. REO'D.(IMAX• 1.25) PANEL MFR. CUTLER-HAMMER
KEY SIZE CU/AL INSULATION CALC' AMPACITY W/O TEMP. FILL RESULT REO'D M20
BUS RATING AMPS 200
TYPE DERATES DERATE DERATE (A) (A) MAIN DISCONNECT AMPS 200
A #12 CU THWN-2 COU 30 0.76 1.0 22.80 8.10ALLOWED PV PER NEC AMPS 40
TERM 25 25 10.13 PV OCPD DEVICE USED AMPS 20
B #10 CU NM-B COU 40 0.91 1.0 36.40 8.10
TERM 35 35 10.13
C #10 CU NM-B COU 40 0.91 L0 36.40 8.1D -/^L
TERM 35 35 10.13 �`03 T
Mike Duhult
CONDUCTOR SCHEDULE 5r VPOperations
KEY CONDUCTORS CU/AL TYPE LOCATION TRADE Uc#1001133 ClassB
A 1-#12 ENGAGE CABLE,I-#6G,FREE AIR CU TC-ER ARRAY SOLAR
8 3-#10, 1-#10 EGC CU NM-B(ROMEX) INTERIOR SOLAR
C 3-#10, 1-#10 EGC CU NM-B(ROMEX) INTERIOR SOLAR O
D CATSE,ETHERNET CABLE CU CAT5E INTERIOR SOLAR 5 6 II
E 1-#6GEC,2010 CEC 690.47(D) CU BARE EXTERIOR SOLAR 7 e o
M -
SEE NOTE 15 10
O
ISA/IP
O O O OA/2P
3
�N
G G G I
13 = E A 8 C = 12
ROOF E%TERIOR-GARAGE
ELECTRICAL DIAGRAM 2.385 KW
LOT#212
MARIPOSA LENNAR: ORIGINALBY: KIM ABCOUWER DATE:17.03.23
960 MONTECITD DRIVE,#302 REVIEWED BY:JIM PARKS I DATE:17.03.23
AT THE LAKES CORONA,CA 92879 REV.# BY DATE I DESCRIPTION •,
Q'N namaste
SOLAR
DWG TITLE: PAGE#: SCALE: SITE LOCATION:
treet
INDIVIDUAL 4Bo Ber,CO8dAay 3D4
PLOT PLAN 2 NTS 29578 EDGEMERE WAY Boulder,C030304
ELECTRICAL MENIFEE,CA 303.667.0300
STRUCTURAL NOTES: NBke Duhul[
SOLAR CONTRACTOR- Sr VPOperatlons
1)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'D.C. Uc#1001133 Class B
2)ALL PV ROOF AjTALHMENTfi_W018E`STAGGEREO.BY ROW AMONGST THE ROOF FRAMING MEMBERS.TO-MAXIMUM EXTENTRO SIBLE
3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL-BE SEALED WITH AN APPROVED SEALANT.
4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED.
5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE.
6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION
MANUAL.VERSION 227.3,PUB 140113-ICC,JANUARY 2014. NT
7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(I')SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(2-)BEYOND THE EDGE
OF THE PV ARRAY/SUB-ARRAY.
8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN AO'.
ROOFING CONTRACTOR-
D DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'.
2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE
APROVED PRIOR TO PV SYSTEM INSTALLATION.
3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(I')OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO y
BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS.
4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. -nit for,
5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. .Lilc C
6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE.BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO 1`n
INSTALLATION.
ELECTRICAL NOTES:
GENERAL-
1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL).
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC.
3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC
WELD.
4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE
MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED.
5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE.
6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE.
SOLAR CONTRACTOR-
7)MODULE CERTIFICATIONS WILL INCLUDE UL1703, IEC61646, IEC61730.
8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS.
9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS.
10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM.
11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE
ROOF SURFACE AND SHALL BE MANAGED IN A WORKMANiIKE MANNER.
12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122.
13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS.
14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT.
15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR.
SIGNAGE-
I6)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES.
17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS.
I8)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT t.
19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE:OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10%
BUILDER ELECTRICAL AND SOLAR CONTRACTORS-
20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER.
21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26.
LENNAR: ORIGINAL BY: KIM ABCOUWER DATE:I7A3.23
MARIPOSA REVIEWED BY: JIM PARKS DATE:17,03.23
-�- - 980 MONTECITO DRIVE,#302
AT THE LAKES CORONA.CA 92879 REV.# BY DATE I DESCRIPTION •�
n S."It
solve
DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 4571 Broadway S4eel
INDIVIDUAL 29578 EDGEMERE WAY Boulder,CO 803N
PLOT PLAN - 3 NTS MENIFEE.CA 303.447.0300
NOTES
-?J9)"0-
Mike Default
Sr VP OperaOons
UO IOO1233 Class 8
CAUTION:
POWER TO THIS BUILDING IS SUPPLIED BY THE
UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS
ARE LOCATED AS SHOWN.
,9J
SOLADECK WIRE
TRANSITION BOX
(UNDER ARRAY)
PV AC DISCONNECT
EXTERIOR-GARAGE
UTILITY METER 8
RAIN SERVICE PANEL
(VERIFIED BY BUILDER)
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
I-877-SLR-POWR
PV POWER SOURCE - AC SPECS
AC OPERATING VOLTAGE: 240 V
AC OPERATING CURRENT: 8.1 A
NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION
LENNAR: ORIGINAL BY: KIM ABCDIIWER DATE:17.03.23
MARIPOSA REVIEWED BY:JIM PARKS DATE 17.03.23
CORONNA,A,C CA
AT THE LAKES 9B0 I DRIVE,#302
A 92879 REV.# BY DATE DESCRIPTION
d namasbe
sous
DWG TITLE: PAGE It: SCALE: SITE LOCATION:
INDIVIDUALtueot
4S]1 Ber,GO8 304
PLOT PLAN 4 NTS 2ENIF EDGEMERE WAY Bo303. 0080306
PLACARDS MENIFEE.CA 303.66].0300