Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
PMT17-01229
City of Menifee Permit No.: PMT17-01229 29714 HAUN RD. �AACCELA4� MENIFEE,CA 92586 Type: Residential Electrical MENIFEE Date Issued: 0 510 5/2 01 7 PERMIT Site Address: 29599 EDGEMERE WAY,MENIFEE,CA Parcel Number: 364-360-010 92584 Construction Cost: $6,328.72 Existing Use: Proposed Use: Description of SOLAR TR 30422-3 MARIPOSA Work: 9 MODULES,2.39KW LOT 30 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA, CA 92879 ATTN GOREEN MUELLER Applicant Phone: 9493498269 JEREMIAH ACAYTURRI License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO,CA 92656 Fee Description aty Amount($1 Solar, Residential or Small Commercial 1 262.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Template.rpt Page 1 of 1 SAFETYBUILDING & • a APPLICATION 't. '"I`Menifee DATE PERMIT/PLAN CHECK NUMBER TYPE: [—]COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILE HOME ❑POOL/SPA ❑SIGN SUBTYPE: ❑✓ ADDITION []ALTERATION []DEMOLITION ❑ELECTRICAL []MECHANICAL ❑NEW []PLUMBING ❑RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit-Plan 2129-2.39 kW/9CS Master Solar PermR No.:PMT16-00910 PROJECT ADDRESS 29599 Edgemere Way, Menifee.CA 92584 ASSESSOR'S PARCEL NUMBER 364-F>60 -010LOT 30 TRACT 30422-3 PROPERTY OWNER'S NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,suite 302, Corona,CA 92879 PHONE (951)817-3680 EMAIL leremiah.acayturri@lennar.com APPLICANT NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL leremiah.acayturd@lennar.com CONTRACTOR'S NAME Lennar Homes of California,Inc. OWNER BUILDER? ❑✓ YES❑NO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona, CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lenner.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ $6,328.72 L SQ FT APPLICANT'S SIGNATURE DATE /06/2017 CITY STAFF USE ONLY DEPARTMENT DISTRIBUTION I� I� CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN SMIP INVOICE PAIDAMOUNT AMOUNT bfl� O CASH O CHECK# O CREDITCARD VISA/MC PLAN CHECK FEES PAIDAMOUNT OCASH OCHECK# OCREDITCARD VISA/MC OWNER BUILDER VERIFIED OYES O No DLNUMBER NOTARIZED LETTER YES O NO City of Menifee Building&Safety Deportment 29714 Houn Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION ✓�,Q, BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MFR. MODEL Mike Dufault ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 2.385 KW I I Sr VPOPlradons LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 9 PCS.1 HYUNDAI I HIS-5265RG (265W) Uc#1001133 Class6 BUYER: INVERTER 9 PCS.l ENPHASE I M215-60-ZLL-SZ2-IG ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: SUB-ARRAY INFORMATION ARRAY#I ARRAY#2 ARRAY#3 MOD OTY 9 NA NA BUYER: TILT 25- NA' I NA• CITY OF M NIFI AZIMUTH 1 266- NA' I NA' DATE: _ City of Menifee bf9fhf3BqG I,ND Building Dept PLAN APPR V MAY 0 3 20it REVIEWEDB Received Apprmal of these lans sl approval Of,any, lalion regulaunns and ar nancc, 3' Ib'-4- JOhslte until comp) fl0n. —_--__— _. az r-- i �N Q J I i l l TRANSITSOLADECION WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT • V EXTERIOR-GARAGE �^] UTILITY METER 8 7 MAIN SERVICE PANEL (VERIFIED BY BUILDER) i NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN 2129 ELEVATION C-LEFT ORIENTATION 3 LOT#30 N MARIPOSA - - - LEN14AR: ORIGINAL BY: KIM ABCOUWER DATE:17.03.23 980 MONTECITO DRIVE,#302 REVIEWED BY:JIM PARKS'"' I DATE:17.03.23 AT THE LAKES CORONA.CA 92879 REV.# BY DATE DESCRIPTION e�namaste :at.. DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 4671 B.,.CO 8 Street 2ENIF EDGEMERE WAY BO393.4CO8D30a PLOT PLAN I/16'= I'-0' MENIFEE,CA 303.467.0300 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE,CA INV.MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INV. MODEL INVERTER SPEC M215-60-ZLL-S22-IG ... TEMP.,ANBIENT LOW(THIN) ASHRAE EXTR.MIN PC -2..._ . .. ...... iMV.-MAX.POWER.IWAC MAX) INVERTER SPEC WATTS(AC), 225. -� 'TEMP.MODULE TEST(TMT) MODULE SPEC °C 25 INV. INPUT V.(VOC MAX) INVERTER SPEC VOLTS(CC) 48 TEMP.DELTA LOW(TOELTA) THIN-TTMT °C -27 INV.OUTPUT V.(Vac MOM) INVERTER SPEC VOLTS(Ac) 240 MOD.MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD.PART NUMBER MODULE SPEC HIS-S265RG INV. OUTPUT CURRENT,IAC INVERTER SPEC AMPS(AC) 0.9 MOD. POWER STC(P) MODULE SPEC WATTS(oc) 265 INV. PHASE QUANTITY INVERTER SPEC PHASE 1 MOD. POWER PTC MODULE SPEC WATTS(Oc) 238 COMPLIANCE INVERTER SPEC UL17A1/IEEE1547 DE MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(DO 31.30 INV. GROUNDING INVERTER SPEC ISOLATED MOD. OPEN CCT.VOLTAGE Nod MODULE SPEC VOLTS(DO 38.10 INV. OTY,MAX/BRANCH CCT. INV.QTYec OTY 9 MOD.COEFF.VOLT/TEMP(COEF) MODULE SPEC V/°C -0.114 BRANCH CCT.OUTPUT,IMAXaC (IAC'INV.QTYBC) I AMPS(AC) 8.10 MOD. MAX VOLTAGE(VMAXMOD) (Voc+(Tu°COEF)) VOLTS(DC) 41.18 INV.QUANTITY,TOTAL INV.OTYi I OTY 9 MOD. OPERATING CURRENT(IMP) MODULE SPEC AMPS(DO 8.50 TOTAL SYSTEM OUTPUT,IMAXTS (IAC-INV.OTYT) I AMPS(AC) 8.10 MOD.SHORT CCT. CURRENT OSC) MODULE SPEC AMPS(uc) 9.00 -- MOD.MAXIMUM CURRENT(IMAX) (ISC• 1.25) AMPS(od 11.25 MIN.AMPACITY REG'0,PER NEC ([MAX- 1.25) AMPS(DO 14.06 SERIES FUSE RATING.MAX MODULE SPEC AMPS(oc) 15 h. canstn ELECTRICAL EQUIPMENT SCHEDULE .ision: KEY OTY MANUFACTURER MODEL NOTES TRADE C DED�I 1 9 HYUNDAI HIS-S265RG (265W) PV MODULE SOLAR 2 9 ENPHASE M215-60-2LL-S22-IG PV INVERTER SOLAR 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX.NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT.NEMA 3R.240V.30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR 8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS:I x ISA-IP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBD PV BREAKER, I X ZOA-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 1 1 1TBD TBD SERVICE PANEL,MIN. 125A BUS BLDR.ELEC. II TBD TBD UTILITY METER, IPH, 120/240V,200A BLDR.ELEC. 12 1 1 1 TBD 1 TBD GROUNDING ELECTRODE UFER BLDR.ELEC. 13 TBD TBD GROUNDING ELECTRODE,690.47(D) SOLAR CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS 1)CONDITION OF USE(COU): I (AMPACITY•TEMP. DEBATE -FILL DERATE) vs.REO'D(IMAX) ITEM UNIT PANEL 2)TERMINALS(TERM): I AMPACITY AT TERMINALS.YS.REG-D.(IMAX• 1.25) PANEL MFR. CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALC AMPACITY W/O TEMP. FILL RESULT REO'D OCD BUS RATING AMPS 200 TYPE DEBATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 A #12 CU I THWN-2 COU 30 0,76 1.0 22.80 8.10 ALLOWED PV PER NEC AMPS 40 TERM 25 25 10.13 20 PV OCPD DEVICE USED AMPS 20 B #10 CU NM-B COU 40 0.91 1.0 36.40 8.10 TERM 35 35 10.13 20 C #U O HENM_ COU 40 0.91 L0 36.40 8.10 s TERM 35 35 10.13 20 J Mike Dufault CONDUCTOR SCHEDULE Sr VP OperaHOns KEY CONDUCTORS CU/AL TYPE LOCATION TRADE Uc#1001133 ClamB A 1412 ENGAGE CABLE, I46G.FREE AIR CU TC-ER ARRAY SOLAR B 3410, 1410 EGC CU NM-B(ROMEX) INTERIOR SOLAR C 3-#10, 1410 EGG CU NM-B(ROMEX) INTERIOR SOLAR O © II D CAT5E,ETHERNET CABLE CU CAT5E INTERIOR SOLAR E I-#6GEC,2010 CEC 690.47(D) CU BARE EXTERIOR SOLAR M SEE NOTE 15 10 0 O ISA/IP O O CD 20N2P 3 Ilyi N G G G I I I ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.385 KW. LOT#30 ORIGINAL BY: KIM ABCOUWER I DATE: LENNAR: 17.03.23 MARIPOSA REVIEWED BY:JIM PARKS I DATE:17.03.23 . . . 980 MONTECITO DRIVE.*302' AT THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTIONZ- u namastEi SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Bmad.y SHaal INDIVIDUAL 29599 EDGEMERE WAY BOuldar,CO BM04 PLOT PLAN 2 NTS MENIFEE,CA 303.447.0300 ELECTRICAL t STRUCTURAL NOTES: Mike Ouhul SOLAR CONTRACTOR- Sr VPOperaUans 0 ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. U&1001133 Clans 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY.R0W-AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. .._ ,)e:...,,... ------ 3)ROOF PENETRATIONS ASSOCIATED WITH BOLA§RAEKIHG_WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3-ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL,VERSION 227.3,PUB I40113-ICC,JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(I')SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(2-)BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. .RT ENT B)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. ROOFING CONTRACTOR- U DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. 2)26 GAUGE INTERLOCKING FLASHING-SIDEWALL-TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE, APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT 00 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. 4/ 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. i be a It Iq 6)BIROSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE.BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. he fedc A,8tite plarn nust be) ELECTRICAL NOTES: GENERAL- U ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. L)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING.NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS..WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT a. 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. MARIPOSA LENNAR: ORIGINAL BY: KIM ABCOUWER DATE:17.03.23 980 MONTECITO DRIVE,#302 REVIEWED BY: JIM PARKS DATE:17.03.23, AT THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION (a namasGe SOl/4 DWG TITLE: PAGE#: I SCALE: SITE LOCATION: INDIVIDUAL 4577 B.,.CO 8 Street PLOT PLAN 3 NTS 29599 EDGEMERE WAY Boulder,CO 80306 NOTES MENIFEE,CA 303.447.0300 l�- Mike DufaVl[ Sr VP Ope2nons Uc#3001133 C1assB CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. in .v 'n the SOLADECK WIRE TRANSITION SOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER 8 MAIN SERVICE PANEL (VERIFIED BY BUILDER) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: U A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION LENNAR: ORIGINAL BY: KIM ASCOUWER DATE:17.03.23 MARIPOSA """ 980 MONTECITO DRIVE•#302 REVIEWED BY:JIM PARKS I DATE:17.03.23 AT THE LAKES CORONA.CA 92879 REV.# BY DATE DESCRIPTION d namasbe SOLAt DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 29599 EDGEMERE WAY Boulder,CO W304 PLOT PLAN 4 NITS PLACARDS MENIFEE.CA 303.447.0300