Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
PMT17-01228
City of Menifee Permit No.: PMT17-01228 29714 HAUN RD. Type: Residential Electrical 4q%CCEL/-> MENIFEE,CA 92586 MENIFEE Date Issued: 0 510 512 01 7 PERMIT Site Address: 29611 EDGEMERE WAY,MENIFEE, CA Parcel Number: 364-360-009 92584 Construction Cost: $6,328.72 Existing Use: Proposed Use: Description of SOLAR TR 30422-3 MARIPOSA Work: 9 MODULES,2.39 KW LOT 29 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA,CA 92879 ATTN GOREEN MUELLER Applicant Phone:9493498269 JEREMIAH ACAYTURRI License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO,CA 92656 Fee Description f3yt Amount Solar,Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The Issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bidg_Permit_Templale.rpl Page 1 of 1 BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION Menifee I DATE PERMIT/PLAN CHECK NUMBER TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILEHOME ❑POOL/SPA [—]SIGN SUBTYPE: ❑✓ ADDITION ❑ALTERATION []DEMOLITION [—]ELECTRICAL [:]MECHANICAL ❑NEW [—]PLUMBING [I RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit-Plan 1924-2.39 kW/9CS Master Solar Permit No.:PMT16-00910 PROJECT ADDRESS 29611 Edgemerre Way,Menifee,C/A 99258844]' ASSESSOR'S PARCEL NUMBER 36q- 360-O(C- ( LOT 29 TRACT 30422-3 PROPERTY OWNER'S NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturr@lennar.com APPLICANT NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S NAME Lennar Homes of California,Inc. OWNER BUILDER? ❑✓ YES❑NO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ $6,328.72 SO FT L SQ FT APPLICANT'S SIGNATURE DATE 04/06/2017 CITYSTAFF USE ONLY DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE I GREEN I 1 SMIP INVOICE PAID AMOUNT AMOUNT GCASH OCHECKk OCREDIT CARD VISA/MC PLAN CHECK FEES PAID AMOUNT O.CASH OCHECK# OCREDITCARD VISA/MC OWNER BUILDER VERIFIED OYES O NO DL NUMBER NOTARIZED LETTER O YES 0 NO City of Menifee Building&.Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-5777 www.cityafinen1fee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION Q J BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MFR. MODEL Mike Dufault ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 1Z.385 KIN i Sr VPOpemians LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 9 PCS.1 HYU14DAI HIS-S265RG(265W) U01Do1133 Class BUYER: -- INVERTER. 1 9 PCS.1 ENPHASE_.I M215-60-2LL-S22-IG ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE- SUB-ARRAY INFORMATION ARRAY#I ARRAY#2 AR AY #3 MOD OTY 9 NA NA BUYER: elTy AC ME F R El TILT 23- NA' NA" City of Menitee DATE: AZIMUTH 176- NA' NA' G S A Building Dept PLAN APP V MAY 0 3 2017 it l'.vn:weo e Received App wal of these lan5 sh apptov;J ,f,any vi latioO regOleUOns and Or nanm 16'-5'ARRAY 3' 17'-3'FLASHING �absile mttl aompl Uon. r_. — —— — —._——— ————l ( I I I I I I I I I I I PC I I SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) i r I I PV AC DISCONNECT _ _ EXTERIOR-GARAGE UTILITY METER e L—— - — MAIN SERVICE PANEL (VERIFIED BY BUILDER) , NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN 1924 ELEVATION A-RIGHT ORIENTATION NON 3 LO #29 I LEN14AR: ORIGINAL BY: KIM ABCOUWER DATE:17.03.23 9e0 MONTECITO DRIVE.#302 MARIPOSA C+"" REVIEWED BY:JIM PARKS DATE:O.O3.23 is AT THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION namaste SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 29611 EDGEMERE WAY Boulder,CO 80304 PLOT PLAN 1 1/I6'=I'-0' MENIFEE.CA 303.447.D300 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE,CA INV.MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH MAX) ASHRAE 2% °C 37 INV.MODEL INVERTER SPEC M215-60-2LL-S22-IG TEMP.AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C .... _. -2 - INV.MAX POWER.(WAC MAX) INVERTER SPEC WATTS(AC)..22$ TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V.Me MAX) INVERTER SPEC VOLTS(oc) 48 _ TEMP,DELTA LOW(TOELTA) TMIN-TTEST °C -27 INV-OUTPUT V.(VAC NON) INVERTER SPEC VOLTS(AC) 240 MOD. MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD. PART NUMBER MODULE SPEC HIS-S265RG INV.OUTPUT'CURRENT,IAC INVERTER SPEC AMPS(AC) 0.9 MOD. POWER STC(P) MODULE SPEC WATTS(oc) 265 INV-PHASE QUANTITY INVERTER SPEC PHASE 1 MOD. POWER PTC MODULE SPEC WATTS 0c) 238 COMPLIANCE INVERTER SPEC UL1741/IEEE154L DEP MOD. OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(10C) 31.30 INV.GROUNDING INVERTER SPEC ISOLATED BR MOD. OPEN CCT. VOLTAGE(VOC) MODULE SPEC VOLTS(OC) 38.10 INV.OTY,MAX/ ANCH CCT. INV.OTYBC QTY 9 MOD.COEFF.VOLT/TEMP(COEF) MODULE SPEC V/°C -0.114 BRANCH CCT. OUTPUT. IMAxEc I UAC'INV.QTYBC) AMPS(AC) 0.10 MOD. MAX VOLTAGE(VMAXMaa) (Vac+(TO-COEF)) VOLTS(oc) 41.18 INV.QUANTITY.TOTAL INV.OTYT OTY 9 MOD. OPERATING CURRENT(IMP) MODULE SPEC AMPS(oc) 8.50 TOTAL SYSTEM OUTPUT,IMAXTS (IAC'INV.OTYT) I AMPS AC) 18.10 MOD.SHORT CCT.CURRENT(ISC) MODULE SPEC AMPS(oc) 9.00 MOD. MAXIMUM CURRENT(IMAX) (ISC• 1.25) AMPS(oC) 11.25 MIN.AMPACITY REO'D,PER NEC (IMAx' 1.25) AMPS(OC) 14.06 SERIES FUSE RATING,MAX MODULE SPEC AMPS(DC) 15 "i C instmC ELECTRICAL EQUIPMENT SCHEDULE 1411 isionsI KEY CITY MANUFACTURER MODEL NOTES TRADE °cl fappra 1 9 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR 2 9 ENPHASE M215-60-2LL-S22-IG PVINVERTER SOLAR 3 1 RSTC/SOLAOECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT.NEMA 3R.24OV.30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR.120V SOLAR 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CATS PART FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR 8 NOTE CUTLER-HAMMER TED PV BRANCH CIRCUIT BREAKERS:I x ISA-IP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBD PV BREAKER, I x 20A-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 I TBD TBO SERVICE PANEL,MIN. 125A BUS BLDR.EL EC. 11 1 TBD TBD UTILITY METER.IPH, 120/24OV.200A BLDR.ELEC. 12 I TBD TBO GROUNDING ELECTRODE LIFER BLDR.ELEC. 13 I TBD I TBD GROUNDING ELECTRODE,690.47(0) 1 SOLAR CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS 1)CONDITION OF USE(COU): I(AMPACITY•TEMP. DERATE•FILL DEBATE) V5.REO'D UHAX) ITEM UNIT PANEL 2)TERMINALS(TERM): I AMPACITY AT TERMINALS. Vs. REQ'D.(WAS• 1.25) PANEL MFR. CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALC. AMPACITV W/0 TEMP. FILL RESULT REO'D OCD BUS RATING AMPS 200 TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 A #12 CU THWN-2 COU 30 0.76 1.0 22.80 8.10 ALLOWED PV PER NEC AMPS 40 TERM 25 25 10.13 20 PV OCPD DEVICE USED AMPS 20 B *10 CU NM-B COU 40 0.91 1.0 36.40 SAID TERM 35 35 10.13 20 NM-L #U O HE COU 40 0.91 110 36.40 8.10 JTERM 35 35 10.13 20 Mike Duhul[ CONDUCTOR SCHEDULE Srs/vroPeanaa: KEY CONDUCTORS CU/AL TYPE LOCATION TRADE UalOO1133 Clul A 1-#12 ENGAGE CABLE,1-#613,FREE AIR CU TC-ER ARRAY SOLAR B 3-#10, 1-#10 EGG CU NM-B(ROM EX) INTERIOR SOLAR C 3-#10, 1-#10 EGC CU NM-B(ROMEX) INTERIOR SOLAR O © II D CAT5E,ETHERNET CABLE CU CAT5E I INTERIOR SOLAR E 1-#615EC,2010 CEC 690.47(D) CU BARE I EXTERIOR SOLAR I SEE NOTE 15 10 ® 150 0 O O 20 O ®N G G G� 13— E A B C = 12 r ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.385 xW LOT#29 LENNAR: ORIGINAL BY: KIM ABCOUWER I DATE:17.03.23 MARIPOSA 900 MONTECITO'DRIVE,4302 REVIEWED BY:JIM PARKS I DATE:17.03.23 _ AT THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION •� 0 namasbe SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 4Bo Ber,CO 3N PLOT PLAN 2 NTS 29611 EDGEMERE WAY Boulder,C080304 ELECTRICAL MENIFEE,CA 303.id].0300 �i STRUCTURAL NOTES: Mike Oafault SOLAR CONTRACTOR- Sr VPOwMloos U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48,O.C. Uc#1001133 Cim9 2)ALL PV ROOF ATTACHMENTS.WILL BE.STAGGERED BY ROW.AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT_ POSSIBLE..., 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. _ " -- 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 61 THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL.VERSION 227-3.PUB 140113-ICC,JANUARY 2014. A1ENI 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(I-)SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. ROOFING CONTRACTOR- U DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING (COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. 2)26 GAUGE INTERLOCKING FLASHING'SIUEWALL-TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(10 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE.DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. ;14 a��j( 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. deR)�!t 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE.BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO I;n5 must INSTALLATION. ELECTRICAL NOTES: GENERAL- 1)ALL PV EQUIPMENT WILL BE TESTED.AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646.IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)OC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS,WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING.OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING /PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT k. 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY: KIM ABCOUWER DATE:17.03.23 LENNAR: MARIPOSA REVIEWED BY: JIM PARKS DATE:17.03.23 980 MONTECITO DRIVE.#302 AT THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION Sima Ste DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broeder,CD 8 304 weet INDIVIDUAL MENI EDGEMERE WAY Boulder, 7030304 PLOT PLAN 3 NTS MENIFEE.CA 303.447.0300 NOTES t Mlke Ou(aul Sr VP Operations 00100103 ClassB CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. • i " 7 cltN SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER B MAIN SERVICE PANEL (VERIFIED BY BUILDER) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: 8.1 A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION LEN MONTECITO DRIVE,#302 MAR: ORIGINAL BY: KIM ABCOUWER DATE:17.03.23 MARIPOSA - 980 REVIEWED BY:"JIM PARKS I DATE:17.03.23 AT THE LAKES CORONA.CA 92879 REV.# BY I DATE I DESCRIPTION namaste It- SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Braadu y SVeel INDIVIDUAL 29511 EDGEMERE WAY Boulder,CO BM04 PLOT PLAN 4 NTS MENIFEE.CA 303.447.0300 PLACARDS