Loading...
PMT17-01227 City of Menifee Permit No.: PMT17-01227 29714 HAUN RD. '(ACCELA—> MENIFEE,CA 92586 Type: Residential Electrical MENIFEE Date Issued: 0 510 512 01 7 PERMIT Site Address: 30288 BRISTOL GATE LN, MENIFEE,CA Parcel Number: 364-360-046 92594 Construction Cost: $6,328.72 Existing Use: Proposed Use: Description of SOLAR TR 30422-3 MARIPOSA Work: 9 MODULES,2.39KW LOT 210 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA,CA 92879 ATTN GOREEN MUELLER Applicant Phone:9493498269 JEREMIAH ACAYTURRI License Number.728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO, CA 92656 Fee Description Oft f Amount fE1 Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Pennit_Templale.rpt Page 1 of 1 BUILDING SAFETY PERIMIT/PLAN CHECK APPLICATION "Menifee DATE PERMIT/PLAN CHECK NUMBER I715' 3125 / TYPE: ❑COMMERCIAL ❑✓ .RESIDENTIAL ❑MULTI-FAMILY ❑MOBILE HOME ❑POOL/SPA ❑SIGN SUBTYPE: ❑✓ ADDITION ❑ALTERATION []DEMOLITION ❑ELECTRICAL ❑MECHANICAL []NEW []PLUMBING ❑RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit-Plan 1924-2.39 kW/9CS Master Solar Permit No.:PMT16-00910 PROJECT ADDRESS 30288 Bristol Gate Ln,Menifee,CA 92584 ASSESSOR'S PARCEL NUMBER 36y- 360-OV46 LOT 210 TRACT 30422-3 PROPERTY OWNER'S NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com APPLICANT NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,suite 302,Corona, CA 92879 PHONE (951)817-3680 EMAIL leremiah.acayturi@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? ❑✓YES❑NO BUSINESS NAME Lennar Homes of California,Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acaytuni@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ $6,328.72 SO FT L SO FT APPLICANT'S SIGNATURE DATE 04/06/2017 CITY STAFF USE ONLY DEPARTMENT DISTRIBUTION W �UU CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEEiXNG FIRE GREEN SMIP INVOICE PAID AMOUNT AMOUNT OCASH OCHECK# OCREDITCARD VISA/MC PLAN CHECK FEES PAIDAMOUNT 0CASH 0CHECK# OCREDITCARD VISA/MC OWNER BUILDER VERIFIED OYES O NO DL NUMBER NOTARIZED LETTER O YES G NO City of Menifee Building&Safety Department 29714 Houn Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION "'7.�J.[�-- BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM CITYMFR. MODEL �ke0vt' ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE yV°OP'° LOCATIONS INDICATED BY THE ILLUSTRATION. SYSTEM SIZE 2.385 KW 1 1 Dori MODULE 9PCS. HYUNDAI HIS-S265RG(265W) BUYER: INVERTER .. 9 PCS.1 ENPHASE I M215-60-ZLL-S22-1G P -. . . . .. ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE:----—______ _----_-- SUB-ARRAY INFORMATION ARRAY#I ARRAY#2 ARRAY#3 CITY OF MEND EE MOD OTV 9 NA NA BUYER: AN SAI TILT 23• NM NV DATE: AZIMUTH 242° NA- NA' DATE: City of Menifee Building Dept REVIEWED By MAY 03 2017 Approvalur hese plans all no Approval of,any violatio Oran) R e C e i p /e d regulations a ordinan This V jobsile until coO mpletion.. IIIII ————— -------- t6'-5'ARRAY LN 11'-H 31" III�I SOLADECK WIRE r TRANSITION ) r6 (UNDER ARRAYAY? I PV AC DISCONNECT EXTERIOR-GARAGE—"— UTILITY METER B I L MAIN SERVICE PANEL L---f— -----J (VERIFIED BY BUILDER) NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN 1924 ELEVATION C ORIENTATION 2 LO #210 LENNAR: ORIGINAL BY: SHAUN MARUNA DATE:16.12.07 MARIPOSA 980 I DRIVE,#302 - REVIEWED BY:KIM ABCOUWER DATE:16.12.08 CORONA. CA ` - AT THE LAKES CA 2 92879 REV.# BY DATE DESCRIPTION �a mast6 saint DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 30288 BRISTOL GATE LN Boulder,CO BD304 PLOT PLAN 1 1/16'=P-0' MENIFEE,CA 303.447.0300 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE,CA INV. MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °L 37 INV. MODEL INVERTER SPEC M215-60-2LL-S22-IG ._ TEMP,AMBIENT LOW(THIN) .ASHRAE EXTR.,MIN °G...... .. -2 INV. MAX POWER,(WAC MAX) INVERTER SPEC. ,WQT.TS,(A0 ,225 TEMP,MODULE TEST(TTEST) MODULE SPEC bC 25 INV. INPUT V,(VOC MAX) INVERTER SPEC VOLTS DC 48 TEMP.DELTA LOW(FoECTA) THIN-TTEST °C -27 INV. OUTPUT V.(VAc NOM) INVERTER SPEC VOLTS(Ad 240 MOD. MANUFACTURER MODULE SPEC HYUNDAI INV. OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD. PART NUMBER MODULE SPEC HIS-S265RG INV. OUTPUT CURRENT.IAC INVERTER SPEC AMPS(AC) 0.9 MOD. POWER STC(P) MODULE SPEC WATTS(DC) 265 INV. PHASE QUANTITY INVERTER SPEC PHASE I MOD. POWER PTC MODULE SPEC WATTS Wc) 238 COMPLIANCE INVERTER SPEC UL1741/IEEE1547„ MOD. OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(DC) 31.30 INV. GROUNDING INVERTER SPEC ISOLATED EPA MOD. OPEN CCT.VOLTAGE(Pot) MODULE SPEC VOLTS(00) 38.10 INV. QTY,MAX/BRANCH OCT. 1 INV.QTYBc OTy 9 MOD. COEFF.VOLT/TEMP(COEF) MODULE SPEC V/"C -0.114 BRANCH CLT. OUTPUT,IMAMC I(IAc•INV.OTYBc) AMPS(AC) 8.10 MOD. MAX VOLTAGE(VMAXMOD) (Vac+(TD•COEF)) VOLTS(Dc) 41.18 INV.QUANTITY,TOTAL I INV.OTYT OTY 9 MOD. OPERATING CURRENT(IMP) MODULE SPEC AMPS(DU 8.50 TOTAL SYSTEM OUTPUT,IMAXTS I 0ACINV.OTY1) I AMPS 00 8.10 MOD. SHORT OCT.CURRENT(ISO) MODULE SPEC AMPS(00 9.00 MOD. MAXIMUM CURRENT(IMAx) (ISC• 1.25) AMPS(DC) 11.25 MIN. AMPACITY REG'D.PER NEC (IMAx• 1.25) AMPS(Dc) 14.06 SERIES FUSE RATING,MAX MODULE SPEC AMPS(OG) 15 ELECTRICAL EQUIPMENT SCHEDULE In, rued to KEY QTY MANUFACTURER MODEL NOTES TRADE i'it as O(th 1 9 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR "•I roved, 2 9 ENPHASE M215-60-2LL-S22-IG PVINVERTER SOLAR 3 1 RSTC/SOLADECK 0786-3RS PV ROOF JUNCTION BOX,NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,240V.30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR.120V SOLAR 6 1 TBD TBO IZOV DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR 0 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS; I x 15A-IP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBO PV BREAKER, I x 2OA-ZP,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 1 TBD TBO SERVICE PANEL.MIN. 125A BUS BLDR.ELEC. II TBD TBD UTILITY METER,IPH, 120/240V,200A BLDR.ELEC: 12 TBD TBD GROUNDING ELECTRODE UFER BLDR.ELEC. 13 1 TBD I TBD I GROUNDING ELECTRODE.690.47(D) I SOLAR CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS U CONDITION OF USE(COU): (AMPACITY•TEMP.DEBATE -FILL DERATE)vs. REO'D OMAX) ITEM UNIT PANEL 2)TERMINALS(TERM): AMPACITY AT TERMINALS.VS.REG'D,(IMAx• 1.25) PANEL HER. CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REO'D OCD BUS RATING AMPS 200 TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 A #12 CU THWN-2 COU 30 0.76 1.0 1 22.80 8.10 ALLOWED PV PER NEC AMPS 40 TERM 25 25 10.13 20 PV OCPD DEVICE USED AMPS 20 B #to CU NM-B COU 40 0.91 1.0 36.40 8.10 TERM 35 35 10.13 20 �q C #10 1 CU NM-B COU 40 0.91 1-0 36.40 8.10k. TERM 35 135 10.13 20 SrwW tt YYPmhuft u CONDUCTOR SCHEDULE W=2133 oarB KEY CONDUCTORS CU/AL TYPE LOCATION TRADE A 1-#12 ENGAGE CABLE.1-#6G,FREE AIR CU TC-ER ARRAY SOLAR 8 3-#10,1-#10 EGC CU NM-B(ROMEX) I INTERIOR SOLAR C 3-#10, 1410 EGC CU NM-B(ROMEX) INTERIOR SOLAR 0 CAT5E,ETHERNET CABLE CU CAT5E INTERIOR SOLAR E 1-#6GEC,2010 CEC 690.47(D) CU BARE EXTERIOR SOLAR 5 6 11 7 • c g O— SEE NOTE 15 10 0 O ISO 20O - - -( LAM G G 13= E A B C =12 r ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.395 KW LOT#210 LENNAR: ORIGINAL BY: SHAUN MARUNA DATE:16.12.07 MARIPOSA 980 HONTECITO DRIVE,#302 REVIEWED BY:KIM ABCOUWER I DATE:16.12.D8.. AT THE LAKES CORONA.CA 92879 REV.# BY DATE DESCRIPTION namasbe SOl/R DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 30288 BRISTOL GATE LN Boulder,CO 803N PLOT PLAN 2 NTS MENIFEE,CA 303.447.0300 ELECTRICAL MMdAw STRUCTURAL NOTES: Ikg tkemwn. SOLAR CONTRACTOR- lIXlsl3l uaue U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL P.V.ROOF.ATTACHMENTS WILL BE,STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS 1011AffIMUI.POSSIBLE._ 3)ROOF PEVOR T OWNS'-ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT." 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL,VERSION 227.3.PUB 140113-ICC.JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH 00 SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(2-)BEYOND THE EDGE EN OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40% ROOFING CONTRACTOR- , O DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3-. 2)26 GAUGE INTERLOCKING FLASHING 'SIDEWALL-TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(I')OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. 5)TILE INSTALLED BELOW THE ARRAY TO HE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. pcsmit1 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO era),stal INSTALLATION. must 151 ELECTRICAL NOTES: GENERAL- 1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURES FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. ID MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122- 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- I6)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING /PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT i'. 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE:OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. LENNAR: ORIGINAL BY: SHAUN MARUNA DATE:16.12.07 MARIPOSA REVIEWEDBY:KIM,AB000WER DATE:16.12.08 AT THE LAKES 980 NA.CA I92 DRIVE,#302 CORONA,CA 92879 REV.# I BY DATE I DESCRIPTION •, Gib nama 156 e DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 30288 BRISTOL GATE LN Boulder,CO 80304 PLOT PLAN 3 NTS MENIFEE.CA NOTES 301447,0300 FfieOuhuh swooear IW SOJI]3I OauB CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. • SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER 8 MAIN SERVICE PANEL (VERIFIED BY BUILDER) tim SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP I-877-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: 8.1 A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION MARIPOSA LENNAR ORIGINAL BY: SHAUN MARUNA DATE:16.12.07 980 MONTECITO DRIVE,#302 REVIEWED BY:KIM ABCOUWER I DATE:16.12.08 AT THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION �n ..LAI SOLAe DWG TfTLE: PAGE*: SCALE: SITE LOCATION: 4571 Bmadway Street INDIVIDUAL 30288 BRISTOL GATE LN BOWdet,CO 30304 PLOT PLAN 4 NTS MENIFEE,CA 303A47.0300 PLACARDS