PMT17-01221 City of Menifee Permit No.: PMT17-01221
29714 HAUN RD.
<ACCELX—> MENIFEE,CA 92586 Type: Residential Electrical
MENIFEE Date Issued: 05/05/2017
PERMIT
Site Address: 30333 BRISTOL GATE LN, MENIFEE,CA Parcel Number: 364-360-021
92584 Construction Cost: $6,328.72
Existing Use: Proposed Use:
Description of SOLAR TR 30422-3 MARIPOSA
Work: 9 MODULES,2.39KW
LOT 51
Owner Contractor
LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC
980 MONTECITO DR#302 25 ENTERPRISE
CORONA,CA 92879 ATTN GOREEN MUELLER
Applicant Phone:9493498269
JEREMIAH ACAYTURRI License Number:728102
LENNAR HOMES OF CALIFORNIA INC
25 ENTERPRISE
ATTN GOREEN MUELLER
ALISO VIEJO,CA 92656
Fee Description Oft f Amount($l
Solar, Residential or Small Commercial 1 252.00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 1.00
General Plan Maintenance Fee-Electrical 1 12.60
$293.60
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bldg_Permlt_Template.rpt Page 1 of 1
��Menifee
DATE PERMIT/PLAN CHECK NUMBER
TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILEHOME ❑POOL/SPA [-]SIGN
SUBTYPE: ❑✓ ADDITION []ALTERATION []DEMOLITION []ELECTRICAL ❑MECHANICAL
[—]NEW ❑PLUMBING El RE-ROOF-NUMBER OF SQUARES
DESCRIPTION OF WORK Solar Permit-Plan 1769-2.39 kW/9CS
Master Solar Penult No.:PMT16-00910
PROJECT ADDRESS 30333 Bristol Gate Ln, Menifee,CA 92584
ASSESSOR'S PARCEL NUMBER 96y —36Q — OZ I LOT 51 TRACT 30422-3
PROPERTY OWNER'S NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr.,suite 302,Corona,CA 92879
PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com
APPLICANT NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr.,suite 302,Corona, CA 92879
PHONE (951)817-3680 EMAIL jeremiah.acayturi@lennar.com
CONTRACTOR'S NAME Lennar Homes of California,Inc. OWNER BUILDER? ❑✓ YES❑NO
BUSINESS NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879
PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com
CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B
VALUATION$ $6,328.72 L SQ FT
APPLICANT'S SIGNATURE DATE 04/06/2017
CITY STAFF USE ONLY
DEPARTMENT DISTRIBUTION „^ �Vv CITY OF MENIFEE BUSINESS LICENSE NUMBER
BUILDING PLANNING ENGINEERING FIRE GREEN 00 SMIP VV
INVOICE PAID AMOUNT
AMOUNT OCASH 0CHECK# OCREDITCARD VISA/MC
PLAN CHECK FEES PAIDAMOUNT OCASH OCHECKII 0CREDIT CARD VISA/MC
OWNER BUILDER VERIFIED OYES O NO DLNUMBER NOTARIZED LETTER O YES O NO
City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777
www.cityofinenifee.us Inspection Request Line 951-246-6213
SYSTEM INFORMATION ''-7.D��.— BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED
ITEM OTY MFR. MODEL Imta°m�mr ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE
vwocemm� 13 LOCATIONS INDICATED BY THE ILLUSTRATION.
SYSTEM SIZE 2QTY KW S,wo,ua a
MODULE 1 9 PCS.1 HYUNDAI HIS-S265RG(265W) BUYER:
.'INVERTER . 9 PCS.l ENPHASE I M215-60-ZLL-S22.IG .1; ..
ROOF TYPE TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE:
SUB-ARRAY INFORMATION
ARRAY#1 ARRAY#2 1 ARRAY#3
MOD OTY 9 NA NA BUYER: IFE
TILT 23° NA' NA' CITY O
AZIMUTH 245° NA' NA' DATE:_ E'
PLAN APPROVA
City of Menifee Itl?VIL'WEDBy
Building Dept
Ul
MAY0 3 2617 Approval of these plans sh 1111011
approval of,any violation f any I
regulations and ordinancel This:
Receivedjobsite Until completion.
-------------------
'-6, ARRAY
30'-6'FLASHING
SOLADECK WIRE
TRANSITION BOX
(UNDER ARRAY)
I I
PV AC DISCONNECT
EXTERIOR-GARAGE
` UTILITY METER A
MAIN SERVICE PANEL
L———————— (VERIFIED BY BUILDER)
I __J
NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF
PLAN 1769 ELEVATION C REVERSE ®�
ORIENTATION 4 LOT#51
: ORIGINAL BY: SHAUN MARUNA DATE:16.12.07
MARIPOSA LENNAR REVIEWED BY:KIM ABCOUWER DATE:I6.12.08
CORONNA,A.C CA
AT THE LAKES 980 I DRIVE.#302
A 92879 REV.* BY DATE DESCRIPTION 4Z.1a namaste
RO{�R
DWG TITLE: PAGE #: SCALE: SITE LOCATION: 4571 Sroadi Street
INDIVIDUAL 30333 BRISTOL GATE LN Boulder,CO 80304
PLOT PLAN 1 U16'=1'-0' MENIFEE,CA 303.447.0300
SYSTEM LAYOUT
MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS
ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC I(WIT DETAIL
LOCATION MENIFEE,CA INV.MAKE INVERTER SPEC ENPHASE
TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INV.MODEL INVERTER SPEC M21S-6O-2LL-SZ2-IG
.TEMP,AMBIENT LOW(THIN) I. ASHRAE EXTR.11ft. inGaa..,, „. -2 INV. MAX POWER,(WAC MAX) INVERTER SPEC WATTS(AC) 225
TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V.(Voc MAX) INVERTER SPEC VOLTS(DO 48
TEMP.DELTA LOW(TDELTA) TMIN-TTEST °C -27 INV.OUTPUT V,(VAc NOM) INVERTER SPEC VOLTS(Ac) 240
MOD.MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60
MOD.PART NUMBER MODULE SPEC HIS-S265RG INV.OUTPUT CURRENT,IAC INVERTER SPEC AMPS(AC) 0.9
MOD.POWER STC(P) MODULE SPEC WATTS(oc) 265 INV.PHASE QUANTITY INVERTER SPEC PHASE I
MOD.POWER PTC MODULE SPEC WATTS(oc) 238 COMPLIANCE INVERTER SPEC UL1741/IEEE1547 I EPA]
MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(DC) 31.30 INV.GROUNDING INVERTER SPEC ISOLATED
MOD. OPEN CCT.VOLTAGE(Voc) MODULE SPEC VOLTS(DC) 38.10 INV.QTY,MAX/BRANCH CCT. INV.GTYSC QTY 9
MOD.COEFF. VOLT/TEMP(COEF) MODULE SPEC V/°C -0.114 BRANCH CCT. OUTPUT,IMAMC I (IAC•INV.OTYac1 AMPS(AC) 8.10 Ap
MOD.MAX VOLTAGE(VMAXMDD) (VOC+(TD°COEF)) VOLTS(DC) 41.18 INV. QUANTITY,TC I INV.OTYr I OTY 9
MOD. OPERATING CURRENT(IMP) MODULE SPEC AMPS(od 8.50 TOTAL SYSTEM OUTPUT, IMAXn. (IFC-INV.GTYT) I AMPS(AD) 8.10
MOD.SHORT CCT. CURRENT 05c) MODULE SPEC AMPS(DO 9.00
MOD.MAXIMUM CURRENT(IMAX) (Isc° 1.25) AMPS(EX) 11.25
MIN.AMPACITY REGO,PER NEC (IMAX• 1.25) AMPS(DC) 14.06
SERIES FUSE RATING.MAX MODULE SPEC AMPS(DC) I5 r:cd to
ELECTRICAL EQUIPMENT SCHEDULE lloTth
KEY OTY MANUFACTURER MODEL NOTES TRADE ;:.I Hro%cd
1 9 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR
2 9 ENPHASE M215-60-2LL-S22-IG PV INVERTER SOLAR
3 1 RSTC/SOLADECK 0706-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR
4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,24OV.30A SOLAR
5 1 ENPHASE ENVOY PV DATA MONITOR, 120V SOLAR
6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR
7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR
8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS;I X ISA-IP(ENVOY) SOLAR
9 NOTE CUTLER-HAMMER TBD PV BREAKER,I X 20A-2P, LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR
10 1 TBD TBD SERVICE PANEL,MIN. 125A BUS BLDR.ELEC.
II TBD TBD UTILITY METER,[PH,120/24OV,200A BLDR.ELEC.
12 1 TBD TBD GROUNDING ELECTRODE UFER BLDR.ELEC.
13 1 1 1 TBD I TBD I GROUNDING ELECTRODE,690.47(D) SOLAR
CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS
U CONDITION OF USE(COU): I(AMPACITY• TEMP.DERATE °FILL DERATE)V5. REO'D(IMAX) ITEM UNIT PANEL
2)TERMINALS(TERM): I AMPACITY AT TERMINALS. vs. REO'D,(IMAX• 1.25) PANEL MFR. CUTLER-HAMMER
KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REO'D OCD BUS RATING AMPS 200
TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200
A #12 CU I THWN-2 COU 30 0.76 1.0 22.80 8.10 ALLOWED PV PER NEC AMPS 40
TERM 25 25 10.13 20 PV DCPD DEVICE USED AMPS 20
B #le CU NM-B COU 40 0.91 1.0 36.40 8.10
TERM 35 35 10.13 20
C #to CU NM-B COU 40 0.91 10 36.40 8.10
TERM 35 35 10.13 20 kwow h
YVIDpmKans
CONDUCTOR SCHEDULE unMmvaX O.r:5
KEY CONDUCTORS CU/AL TYPE LOCATION TRADE
A 1412 ENGAGE CABLE,146G,FREE AIR CU TC-ER ARRAY SOLAR
B 3-#10,1410 EGC CU NM-B(ROMEX) INTERIOR SOLAR
C 3-#10,1-#10 EGC CU NM-B(ROMEX) INTERIOR SOLAR
D CAT5E.ETHERNET CABLE CU CAT5E INTERIOR SOLAR
E I-#6GEC,2010 CEC 690.47(0) CU I BARE I EXTERIOR SOLAR
5 6 II
7 • o 0
M -
SEE NOTE 15. 10
O � O
ISA/IP
9
0
'N
GaG
ROOF EXTERIOR-GARAGE
ELECTRICAL DIAGRAM 2.385 KW
LOT#51
LENNAR: ORIGINAL BY: SHAUN MARUNA DATE:Ib.12.07
MARIPOSA - 980 MONTECITO DRIVE.#302 REVIEWED BY:KIM ASCOUWER I DATE:Ib.12.08
AT THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION
Q�namaste
SOLAR
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street
INDIVIDUAL 30333 BRISTOL GATE LN Boulder,CO 80304
PLOT PLAN 2 NTS MENIFEE,CA 3G3A47.a300
ELECTRICAL
Mikv Dufaull
STRUCTURAL NOTES: vwoperamm
SOLAR CONTRACTOR- uuiaovaa Uave
1)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C.
2)ALL.PV ROOF.AATACHMENTS..WILL BESTAGGERED BY ROW AMONGST THE ROOF.FRAMING.NEMBERSITP:MAXIMUM.EXTENT POSSIBLE. .. ... .
3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT.
4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED.
5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE.
6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION
MANUAL.VERSION 227.3,PUB 140113-ICC,JANUARY 2014.
7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(I')SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(2-)BEYOND THE EDGE
OF THE PV ARRAY/SUB-ARRAY. .
8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'.
ROOFING CONTRACTOR-
1)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3%
2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE
APROVED PRIOR TO PV SYSTEM INSTALLATION.
3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(T)OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO
BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS.
4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE,
5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS.
6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE.BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO cimU if
INSTALLATION.
J,ilalC
9u�l be I
ELECTRICAL NOTES:
GENERAL-
U ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL).
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC.
3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC
WELD.
4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE
MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED.
5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE.
6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE.
SOLAR CONTRACTOR-
7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730.
8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS.
9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS.
10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM.
II)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE
ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER.
12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122.
13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS.
14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT.
15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR.
SIGNAGE-
16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES.
17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS.
18)MARKING /PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT k.
19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE,'OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'.
BUILDER ELECTRICAL AND SOLAR CONTRACTORS-
20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER.
21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26.
/� LENNAR: ORIGINAL BY: SHAUN MARUNA DATE;16.12.07
MARIPOSA. _ REVIEWED BY:KIM ABCOUWER DATE:16.12.08
980 MONTECITO DRIVE,#302
AT THE LAKES CORONA.CA 92879 REV.# BY DATE DESCRIPTION
�b namc1W.
SOl/!
DWG TITLE: PAGE#: SCALE: SITE LOCATION:
INDIVIDUAL45Ti Broadway Street
PLOT PLAN 3 NTS. 30333 BRISTOL GATE LN Boulder,CC)00 4
NOTES MENIFEE,CA
RLh Ubaul,
tid 1001133 ClasaB
CAUTION:
POWER TO THIS BUILDING IS SUPPLIED BY THE
UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS
ARE LOCATED AS SHOWN.
YV"V
SOLADECK WIRE
TRANSITION BOX
(UNDER ARRAY)
PV AC DISCONNECT
EXTERIOR-GARAGE
UTILITY METER B
MAIN SERVICE PANEL
(VERIFIED BY BUILDER)
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
I-877-SLR-POWR
PV POWER SOURCE - AC SPECS
AC OPERATING VOLTAGE: 240 V
AC OPERATING CURRENT: 8.1 A
NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION
LENNAR:. ORIGINAL BY: SHAUN MARUNA DATE:16.12.07
MARIPOSA .. - 2 REVIEWED BY:KIM ASCOUWER DATE:16-12.08
980 NA.CA 92 DRIVE,#302
AT THE LAKES CORONA.CA 92879 REV.# BY DATE DESCRIPTION
Q nCI masGe
:etwb
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 BmaEway Street
INDIVIDUAL 30333 BRISTOL GATE LN Bouldeq CO 80304
PLOT PLAN 4 NTS MENIFEE,CA 303.447.0300
PLACARDS