PMT17-01220 City of Menifee Permit No.: PMT17-01220
29714 HAUN RD.
�ACCELA7. MENIFEE,CA 92586 Type: Residential Electrical
MENIFEE Date Issued: 0510512017
PERMIT
Site Address: 29563 EDGEMERE WAY, MENIFEE,CA Parcel Number. 364-360-012
92584 Construction Cost: $6,328.72
Existing Use: Proposed Use:
Description of SOLAR TR 30422-3 MARIPOSA
Work: 9 MODULES,2.39KW
LOT 32
Owner Contractor
LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC
980 MONTECITO DR#302 25 ENTERPRISE
CORONA, CA 92879 ATTN GOREEN MUELLER
Applicant Phone:9493498269
JEREMIAH ACAYTURRI License Number:728102
LENNAR HOMES OF CALIFORNIA INC
25 ENTERPRISE
ATTN GOREEN MUELLER
ALISO VIEJO,CA 92656
Fee Description Qtty Amount tEl
Solar,Residential or Small Commercial 1 252.00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 1.00
General Plan Maintenance Fee-Electrical 1 12.60
$293.60
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing builiding operations being carded on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bldg_Parmit_Template.rpt Page 1 of 1
yp4
.."Menifee
DATE PERMIT/PLAN CHECK NUMBER 1 a
TYPE: [—]COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY El MOBILE HOME ❑POOL/SPA []SIGN
SUBTYPE: ❑✓ ADDITION ❑ALTERATION ❑DEMOLITION [—]ELECTRICAL El MECHANICAL
❑NEW ❑PLUMBING El RE-ROOF-NUMBER OF SQUARES
DESCRIPTION OF WORK Solar Permit-Plan 2129-2.39 kW/9CS
Master Solar Permit No.: PMT16-00910
PROJECTADDRESS 29563 Edgemere Way, Menifee,CA 92584
ASSESSOR'S PARCEL NUMBER 36Y-360 `012 LOT 32 TRACT 30422-3
PROPERTY OWNER'S NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr.,suite 302,Corona,CA 92879
PHONE (951)817-3680 EMAIL jeremiah.acayturd@lennar.com
APPLICANT NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr.,suite 302,Corona,CA 92879
PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com
CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? ❑✓ YES❑NO
BUSINESS NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr.,Suite 302, Corona,CA 92879
PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com
CONTRACTOR'S STATE LC NUMBER 728102 LICENSE CLASSIFICATION A&B
VALUATION$ $6,328.72 SO FT LSQFT
APPLICANT'S SIGNATURE DATE 04/06/2017
CITY STAFF USE ONLY
DEPARTMENT DISTRIBUTION lW �uv CITY OFMENIFEE BUSINESS LICENSE NUMBER
BUILDING PLANNING ENGINEERING FIRE GREEN SMIP uv
INVOICE
AMOUNT PAID AMOUNT CASH 0CHECK# 0CREDI7 CARD VISA/MC
PLAN CHECK FEES PAID AMOUNT OCASH 0CHECK# OCREDITCARD VISA/MC
OWNER BUILDER VERIFIED OYES O NO DLNUMBER NOTARIZED LETTER G YES C NO
City of Menifee Building&Safety Department 29714 Houn Rd. Menifee, CA 92586 951-672-6777
www.cityofinenifee.us Inspection Request Line 951-246-6213
SYSTEM INFORMATION "'7�J-C� BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED
ITEM OTV MFR. MODELa`0i1ap1t ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE
srwoRanVwn LOCATIONS INDICATED BY THE ILLUSTRATION.
SYSTEM SIZE 12.385KW I Iuw rwsua Oassa
MODULE 9 PCS.1 HYUNDAI I FaS-S265RG(265W) BUYER:
INVERTER 1 9 PCS-1 ENPHASE I M2I5-60-2LL-S22-IG
ROOF TYPE I TILE W7 COMPOSITE SHINGLE UNDER ARRAY DATE:
SUB-ARRAY INFORMATION
ARRAY#I ARRAY#2 ARRAY#3
MOD OTY 9 NA NA BUYER: ^*'*'v'^�'ME FE1
TILT 23° NA- NA'
AZIMUTH 250- NA" NA'
DATE: -- G A D S
PLAN APPR V
REVIEWED B
Approval of tbese p am sh
approval of,any vic lation
regulations and Ord nancOS
jobsite until COMO ion.
3' I6'-4'
-----------
i
i
i
SOLAOECK WIRE_,,,- m_
TRANSITION BOX
(UNDER ARRAY) +
PV AC DISCONNECT
EXTERIOR-GARAGE
UTILITY METER 8
MAIN SERVICE PANEL,.r
L—
(VERIFIED BY BUILDER) ---- — -----
——— ,tee `----
NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF
PLAN 2ATI /V ELEVATION A
ORIENTATION 3 LOT# 2 �
LENNAR:, ORIGINAL BY: SHAUN MARUNA DATE:16.12.07
980 MONTECITO DRIVE,#302
MARIPOSA I/ REVIEWED BY:KIM ABCOUWER DATE:16.12.08
AT THE LAKES
CORONA,CA 92879 REV.# BY DATE DESCRIPTION
V masbe
SOIAR
OWE TITLE: PAGE#: SCALE: SITE LOCATION:
INDIVIDUAL 4Bo Broadway 3M
PLOT PLAN 1 1116'= I'-0' MENIF EOGEMERE WAY Boulder, 7. B0304
SYSTEM LAYOUT MENIFEE,CA 303.447.0300
MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS
ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL
LOCATION MENIFEE,CA INV.MAKE INVERTER SPEC ENPHASE
TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INV.MODEL INVERTER SPEC M215-60-2LL-S22-IG
TEMP,AMBIENT.LOW..(THWD ASHRAE EXTR.MIN •C -2 INV.MAX POWER.(WAnMAX), INVERTER SPEC WATTS(Ac) 225 _
TEMP,MODULE TEST(TT MODULE SPEC °C 25 INV. INPUT V,(Voc MAX) INVERTER SPEC VOLTS(oc) 48
TEMP,DELTA LOW(TOELTA) THIN-TTEST °C -27 INV.OUTPUT V,(VAc NOM) INVERTER SPEC VOLTS(Ac) 240
MOD.MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60
MOD.PART NUMBER MODULE SPEC HIS-S265RG INV.OUTPUT CURRENT,IAC INVERTER SPEC AMPS(AC) 0.9
MOD.POWER STC(P) MODULE SPEC WATTS(Dc) 265 INV.PHASE QUANTITY INVERTER SPEC PHASE I
MOD.POWER PTC MODULE SPEC WATTS(O[) 236 COMPLIANCE INVERTER SPEC UL1741/IEEE1547
MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(oc) 31.30 INV. GROUNDING INVERTER SPEC ISOLATED TTv np�
MOD. OPEN CCT. VOLTAGE(Voc) MODULE SPEC VOLTS(D[) 38.10 INV.QTV,MAX/BRANCH CCT. INV.OTYBc OTY 9
MOD.COEFF. VOLT/TEMP(COEF) MODULE SPEC V/°C -0.114 BRANCH CCT. OUTPUT.IMasee (IAc•INV.OTYac1 AMPS(AC) 8.10
MOD.MAX VOLTAGE(VMAXMOD) (Voc+(TD•COEF)) VOLTS(Dc) 41.18 INV.QUANTITY,TOTAL INV.OTYT QTY 9
MOD, OPERATING CURRENT(IMP) MODULE SPEC AMPS(D[) 8.50 TOTAL SYSTEM OUTPUT, InAXTs (IAt•INV.QTYi) AMPS(A[) 118.10
MOO. SHORT CCT.CURRENT(ISC) MODULE SPEC AMPS(oo) 9.00
MOD.MAXIMUM CURRENT(IMAX) (ISc• 1.25) AMPS(Oc) 11.25
MIN.AMPACITY REO'D,PER NEC (IMAX• 1.25) AMPS(a) 14.06
SERIES FUSE RATING,MAX MODULE SPEC AMPS(oc) 15
ELECTRICAL EQUIPMENT SCHEDULE ot be consl UW to
KEY QTY MANUFACTURER MODEL NOTES TRADE Iy provi5i0 a of th
1 9 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR 15 set ofap III
2 9 ENPHASE M215-60-2LL-S22-IG PV INVERTER SOLAR
3 1 RSTC/SOLADECK 0786-3RS PV ROOF JUNCTION BOX,NEMA 3R SOLAR
4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,240V,30A SOLAR
5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR
6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR
7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR
8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS:1 X 15A-IP(ENVOY) SOLAR
9 NOTE CUTLER-HAMMER TBD PV BREAKER, I x 20A-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR
10 I TBD TBD SERVICE PANEL,MIN. 125A BUS BLDR.ELEC.
II I TBD 1 TBD 1
UTILITY METER.[PH.120/24OV,200A BLDR.ELEC.
12 TBD I TBD I GROUNDING ELECTRODE UFER BLDR.ELEC.
13 I I I TED I TBD I GROUNDING ELECTRODE,690.47(D) SOLAR
CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS
1)CONDITION OF USE(COLD: (AMPACITY• TEMP.DERATE•FILL DERATE)v5.REO'D(IMAX) ITEM UNIT PANEL
2)TERMINALS(TERM): AMPACITY AT TERMINALS.vs. REO'D, [MAX( • 1.25) PANEL MFR. CUTLER-HAMMER
KEY SIZE CU/AL INSULATION
CALC. AMPACITY W/O TEMP. FILL RESULT NREO'DOCD BUS RATING AMPS 200
TYPE DERATES DERATE DEBATE W USED(A) MAIN DISCONNECT AMPS 200
A #12 CU THWN-2 COU 30 0.76 1.0 2280 ALLOWED PV PER NEC AMPS 40
TERM 25 25 20 PV OCPD DEVICE U#10 CU NM-B COU 40 0.91 1.0 36.40 TERM 35 35 20NM-B COU 40 0.91 1.0 36.40 TERM 35 35 20 SrWObuk
Sr VP mf..k s
CONDUCTOR SCHEDULE
KEY CONDUCTORS CU/AL "BAREIXXT1.11i.
CATION TRADE
A 1-#12 ENGAGE CABLE,1-#6G,FREE AIR CU RAY SOLAR
B 3-#10,I-#10 EGC CU ERIOR SOLAR
C 3-#10, I-#10 EGC CU ERIOR SOLAR
D CATSE,ETHERNET CABLE CU ERIOR SOLAR
E 1-#6GEC,2010 GEL 690.47(D) CU TERIOR SOLAR
S 6 II
7 • o u
M —
SEE NOTE 15 10
® „
O O a)
O
G G
G
I 1 I
ROOF EXTERIOR-GARAGE
ELECTRICAL DIAGRAM 2.385 KW
LOT#32
LENNAR: ORIGINAL BY: SHAUN MARUNA I DATE:16.12.07
MARIPOSA 980 MONTECITO DRIVE,#302 REVIEWED BY:KIM,ABCOUWER I DATE:16.12.08
AT THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION
namaste
SOLAP
DWG TITLE: PAGE O: SCALE: SITE LOCATION: 4571 Broadway Street
INDIVIDUAL 29563 EDGEMERE WAY Boulder,CO 80304
PLOT PLAN 2 NITS MENIFEE,CA 303.447.0300
ELECTRICAL
MAa eN ult
STRUCTURAL NOTES:
s.wapenrau
SOLAR CONTRACTOR- Ixutaovv ueue
1)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C.
-......2),ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST�HE,ROaF RAM".G MEMBERS.TO MAXIMUM EXTENT POSSIBLE. _ _ .. �.....,..,.� ., .
r y 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SULAT. ,
4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED.
5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE.
6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION
MANUAL,VERSION 227.3.PUB 140113-ICC.JANUARY 2014.
7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(I')SPACE BETWEEN PV MODULES. SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND THE EDGE
OF THE PV ARRAY/SUB-ARRAY. MNI
8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'.
ROOFING CONTRACTOR-
1)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'.
2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION.IT SHALL BE
APROVED PRIOR TO PV SYSTEM INSTALLATION.
3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT 01 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE.DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO
BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS.
4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE.
5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS.
6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE.BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO Ptt
INSTALLATION. oral,sta
must h
ELECTRICAL NOTES:
GENERAL-
U ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL).
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/GEC.
3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC
WELD.
4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE
MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED.
5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE.
6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE.
SOLAR CONTRACTOR-
7)MODULE CERTIFICATIONS WILL INCLUDE UL1703.IEC61646, IEC61730.
8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS.
9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS.
10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM.
11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS. WIRING SHALL NOT MAKE CONTACT WITH THE
ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER.
12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122.
13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS.
14)A PV AGGREGATION PANEL(SIB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT.
15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR.
SIGNAGE-
16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES.
17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS.
18)MARKING /PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT i'.
19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE:OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'.
BUILDER ELECTRICAL AND SOLAR CONTRACTORS-
20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER.
21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26.
LENNAR: ORIGINAL BY: SHAUN MARUNA DATE:16.12.07
MARIPOSA REVIEWED BY:KIM ABCOUWER DATE:16.12.08
CORONNA.A.C CA
AT THE LAKES 980 I DRIVE;#302
A 92879 REV.# BY DATE DESCRIPTION
la namasbd
iOl,a
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street
INDIVIDUAL 29563 EDGEMERE WAY Boulder,CO 803M
PLOT PLAN 3 NTS MENIFEE,CA
NOTES 303.447.0300
kLta Wlauh
S`NOpxaHenf
UCP1W1133 Gau6
CAUTION:
POWER TO THIS BUILDING IS SUPPLIED BY THE
UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS
ARE LOCATED AS SHOWN.
�n
ilv
the
SOLADECK WIRE
TRANSITION BOX
(UNDER ARRAY)
PV AC DISCONNECT
EXTERIOR-GARAGE
UTILITY METER 8
MAIN SERVICE PANEL
(VERIFIED BY BUILDER)
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
1-877-SLR-POWR
PV POWER SOURCE - AC SPECS
AC OPERATING VOLTAGE: 240 V
AC OPERATING CURRENT: 8.1 A
NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION
LENNAR: ORIGINAL BY: SHAUN MARUNA DATE:16.12.07
MARIPOSA 980 MONTECITO DRIVE,#302 REVIEWED BY:KIM ABC ER I DATE:16.12.08
AT THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION
Cl
namaste
ae4Aa
DWG TITLE: PAGE#: SCALE: SITE LOCATION:
INDIVIDUAL 4871lde e 3N
PLOT PLAN 4 NTS 2ENIF EDGEMERE WAY Bo303. C00080304
PLACARDS MENIFEE,CA 303.447.0300