Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
PMT17-01218
City of Menifee Permit No.: PMT17-01218 29714 HAUN RD. CACCELA. MENIFEE,CA92586 Type: Residential Electrical MENIFEE Date Issued: 04/2712017 PERMIT Site Address: 30252 BRISTOL GATE LN, MENIFEE,CA Parcel Number: 364-360-043 92584 Construction Cost: $6,328.72 Existing Use: Proposed Use: Description of SOLAR TR 30422-3 MARIPOSA Work: 9 MODULES,2.39KW LOT 207 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA,CA 92879 ATTN GOREEN MUELLER Applicant phone:9493498269 JEREMIAH ACAYTURRI License Number.728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALSO VIEJO,CA 92656 Fee Description Qt t Amount 1E1 Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The Issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise staled,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Pennit_Template.rpt Page 1 of 1 .Menifee DATE PERMIT/PLAN CHECK NUMBER TYPE: ❑COMMERCIAL QRESIDENTIAL ❑MULTI-FAMILY ❑MOBILEHOME ❑POOL/SPA ❑SIGN SUBTYPE: ❑✓ ADDITION ❑ALTERATION ❑DEMOLITION ❑ELECTRICAL ❑MECHANICAL ❑NEW [-]PLUMBING ❑RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit-Plan 1769-2.39 kW/9CS Master Solar Permit No.:PMTl MD910 PROJECT ADDRESS 30252 Bristol GateL/n, Menifee,CA 92584 ASSESSOR'S PARCEL NUMBER 36"/, -:�6O-0g3 LOT 207 TRACT 30422-3 PROPERTY OWNER'S NAME Lerner Homes of California, Inc. ADDRESS 980 Montecito Dr.,suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL leremiah.acayturri@lennar.com APPLICANT NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,suite 302, Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S NAME Lerner Homes of California,Inc. OWNER BUILDER? ❑✓ YES❑NO BUSINESS NAME Lerner Homes of California,Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL leremiah.acayturri@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ $6,328.72 SQ FT L SO FT APPLICANT'S SIGNATURE lkc DATE 04/06/2017 CITY STAFF USE ONL Y DEPARTMENT DISTRIBUTION E�l CITY OF MENIFEEBU5INESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE I GREEN SMIP l INVOICE PAID AMOUNT AMOUNT n 5- OCASH OCHECKR OCREDa CARD VISA/MC PLAN CHECK FEES PAIDAMOUNT OCASH 0CHECK# OCREDITCARD VISA/MC OWNER BUILDER VERIFIED OYES O NO OL NUMBER NOTARIZED LETTER O YES NO City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION ,\J BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MFR. MODEL Mikp FAult ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 2.385 KW LOCATIONS INDICATED BY THE ILLUSTRATION. Sr VP Operations MODULE 9 FCS.I HYUNDAI HIS-S265RG(265W) U01001133 CImB BUYER: —_ _--_---___— INVERTER, 1 9 FCS.1 ENPHASE MZ15-60-2LL-SZ2-IG ROOF TYPE I CONCRETE TILE DATE: i- Mf NIF SUB-ARRAY INFORMATION ARRAY#1 ARRAY#2 ARRAY#3 BUILDING MD MOD OTY 9 NA NA BUYER- TILT — TILT 23° NA° NM DATE- �1_i1i+1 APPR VA AZIMUTH 258° NA' NA' S`rtU i'MED City of Menifee — Building Dept Ap;roval of these pans sh. APR 2 ' 201/ =aproval of,any violi lion of A r> ulations and ordi antes. Receir, � -:; obsite until complet! , ----------- ------ ------ I t I I I SOLADECK WIRE I6'-5'ARRAY TRANSITION BOX IT-3-FLASHING $a, I (UNDER ARRAY) I I PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER 8 MAIN SERVICE PANEL VERIFIED BY BUILDER) L--------- L--- I GOP NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN I769 ELEVATION 8 ORIENTATION 2 LOT#207 LENNAR: ORIGINAL BY: KIM ABCOUWER DATE:16.11. 980 29 MARIPOSA E - - REVIEWED BY:SHAUN MARUNA DATE:I0.11.30 AT THE LAKES CORONNA.A.C LA A 92 DRIVE,#302 879 REV.# BY DATE DESCRIPTION •, to nomosre DWG TITLE: PAGE#: SCALE: SITE LOCATION: teet INDIVIDUAL 4Bo BouldeBmar, 8 304 PLOT PLAN 1 I/16-=1'-0' 30252 BRISTOL GATE LANE Bo303.4C080304 SYSTEM LAYOUT MENIFEE.CA 303.447.0300 MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE,CA INV.MAKE INVERTER SPEC ENPHASE TEMP.AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INV.MODEL INVERTER SPEC M215-60-2LL-S22-IG TEMP..AMBIENT LOWdTHIN), ASHRAE EXTR.,MIN °C -2 INV.MAX.P➢.WER.(WAC MAX) _ INVERTER SPEC WATTS(AC) 225 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V,(Voc M ) INVERTER SPEC VOLTS(6C) 48 TEMP,DELTA LOW(ToELTA) THIN-TTBST °C -27 INV.OUTPUT V,(VAC NOM) INVERTER SPEC VOLTS(AC) 240 MOD. MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD. PART NUMBER MODULE SPEC HIS-S265RG INV.OUTPUT CURRENT.IAC INVERTER SPEC AMPS(AC) 0.9 DE MOD. POWER STC(P) MODULE SPEC WATTS(oc) 265 INV.PHASE QUANTITY INVERTER SPEC PHASE MOD. POWER PTC MODULE SPEC WATTS(oc) 238 COMPLIANCE INVERTER SPEC UL1741/IEEE1547 MOD. OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(DO 31.30 INV.GROUNDING INVERTER SPEC ISOLATED MOD. OPEN CCT. VOLTAGE(VOC) MODULE SPEC VOLTS(Oc) 38.10 INV.OTY,MAX/BRANCH CCT. INV.QTYBC OTY 9 MOD. COEFF.VOLT/TEMP(COEF) MODULE SPEC V/°C -0.114 BRANCH CCT. OUTPUT,IMAXRC (IAC*INV.QTYBC) AMPS(AC) 0.10 MOD. MAX VOLTAGE(VMAXMOD) (Voc+(TD-COEF)) VOLTS(DO 41.18 INV. QUANTITY,TOTAL I INV-OTYT OTY 9 MOD. OPERATING CURRENT(IMP) MODULE SPEC AMPS(DO 5.50 TOTAL SYSTEM OUTPUT,IMAxrs (IAC*INV.QTYT) AMPS(it) 8.10 MOD.SHORT CCT. CURRENT 050 MODULE SPEC AMPS(DO 9.00 MOD. MAXIMUM CURRENT(IMAX) (Isc. 1.25) AMPS(00 11.25 MIN. AMPACITY REO'D,PER NEC (IMAX- 1.25) AMPS(O[) 14.06 SERIES FUSE RATING.,MAX MODULE SPEC AMPS(oc) 15 ELECTRICAL EQUIPMENT SCHEDULE KEY DTY MANUFACTURER MODEL NOTES TRADE 'it be On6fTUE 1 9 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR ;prove ions of 2 9 ENPHASE M215-60-2LL-S22-IG PVINVERTER SOLAR 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR .s set c appr0l 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,24OV,30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR 0 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS:I x BA-IP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBD PV BREAKER, I x 2OA-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 1 TBD TBD SERVICE PANEL,MIN. 125A BUS BLDR.ELEC. II TBD TBD UTILITY METER.1Ph.120/24OV.200A BLDR.ELEC. 12 T00 I TBD I GROUNDING ELECTRODE LIFER BLDR.ELEC. 13 1 I 1 TBD I TBD I GROUNDING ELECTRODE,690.47(D) SOLAR CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS 1)CONDITION OF USE(COU): I (AMPACITY•TEMP.DERATE •FILL BERATE) V5.REO'D(IMAX) ITEM UNIT PANEL 2)TERMINALS(TERM I AMPACITY AT TERMINALS. VS.REO'D.(IMAX° 1.25) PANEL MFR. CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REO'D OCD BUS RATING AMPS ZOO TYPE BERATES BERATE BERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 A #12 CU I THWN-2 COU 130 0.76 L0 22.80 8.10 ALLOWED PV PER NEC AMPS 40 TERM 1 25 25 10.13 20 PV OCPD DEVICE USED AMPS 20 B #10 CU NM-B. COU 1 40 0.91 1.0 36.40 8.10 TERM 35 1 135 10.13 20 ^ C #10 CU I NM-B COU 1 40 0.91 11.0 1 36.40 8.10 ��\� TERM 135 1 135 10.13 20 1 Mike Ouffaault CONDUCTOR SCHEDULE Sr VP Operations KEY CONDUCTORS CU/ALMK.NX.R1.1�. CATION TRADE UC#3001133 Oa55B A I-#12 ENGAGE CABLE,I-#6G,FREE AIR CU RAY SOLAR B 3-#10, 1-#10 EGC CU ERIOR SOLAR C 3-#10.1-#10 EGC CU ERIOR SOLAR D CAT5E.ETHERNET CABLE CU ERIOR SOLAR 5 © II E 1-#6GEC,2010 CEC 690.47(D) CU TERIOR SOLAR O e o Y O SEE NOTE 15 I 10 0 I6AlIP O O 20M L IN G G� B C 10 ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.305 KW LOT#207 r� LENNAR: ORIGINAL BY: KIM ABCOUWER DATE:16.11.29 MARIPOSA .. REVIEWED BY:SHAUN MARUNA DATE:16.11.30 AT THE LAKES CORONA.80 A9287CITO RIVE.#302 CORONA,CA 92879 REV.# BY DATE DESCRIPTION Qla namaste SOAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Slreel INDIVIDUAL 30252 BRISTOL GATE LANE Boulder,CO 80304 PLOT PLAN 2 NTS MENIFEE,CA 303.447.0300 ELECTRICAL STRUCTURAL NOTES: Mlke Duhult SOLAR CONTRACTOR- Sr VP Operations I)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS.ATF- NOT GREATER THAN M D.C. Uck 1001133 CIa55 B 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW.AMONGST.THE-ROOF MING MEMBERS,TO,MAXIMUM EXTENT POSSIBLE. .._. . 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE`SE'1ILE�l� APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3-ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL,VERSION 227.3.PUB 140113-ICC,JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(I')SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND.A MINIMUM OF TWO INCHES(2')BEYOND THE EDGE AR MEN OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. ROOFING CONTRACTOR- U DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. . • 2)26 GAUGE INTERLOCKING FLASHING-SIDEWALL-TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION- 31 PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT 00 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE.DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE.BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. I lea ermitfa ederi I,state a plans I nustbei ELECTRICAL NOTES GENERAL- 1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL).. 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH.. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM, 11)MODULE AND.ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR: SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING /PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT t. 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE:OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY: KIM ABCOUWER DATE:I .11. LENNAR: 29 MARIPOSA REVIEWED BY: SHAUN MARUNA I DATE:16.11.30 AT THE LAKES CORONA RIVE:#302 CORONA,CAA 92B7 92879 REV.# BY GATE I DESCRIPTION 2amasCe swine DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 30252 BRISTOL GATE LANE Boulder,CO 80304 PLOT PLAN 3 NITS MENIFEE,CA NOTES 303.447.0300 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. LD �n SOLADECK WIRE TRANSITION BOX m the (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER 8 MAIN SERVICE PANEL (VERIFIED BY BUILDER) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V Slyp Operations AC OPERATING CURRENT: 8.1 A Lich 1W1133 ClassB NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION p LENNAR: ORIGINAL BY: KIM ABCOUWER DATE:16.11.29 MARIPOSA 980 MOMECITO DRIVE,#302 REVIEWED BY:'SHAUN MARUNA I DATE:I6-ii30 AT THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION •� d namaste SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4S71 Bmadw Sy Sheet INDIVIDUAL 30252 BRISTOL GATE LANE Baald.,,CO W304 PLOT PLAN A NTS MENIFEE.CA 303.447.0300 PLACARDS