Loading...
PMT17-01217 City Of Menifee Permit No.: PMT17-01217 29714 HAUN RD. <A—CCELP MENIFEE,CA 92586 Type: Residential Electrical MENIFEE Date Issued: 04/27/2017 PERMIT Site Address: 30240 BRISTOL GATE LN,MENIFEE,CA Parcel Number: 364-360-042 92584 Construction Cost: $6,328.72 Existing Use: Proposed Use: Description of SOLAR TR 30422-3 MARIPOSA Work: 9 MODULES,2.39KW LOT 206 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA,CA 92879 ATTN GOREEN MUELLER Applicant Phone:9493498269 JEREMIAH ACAYTURRI License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO,CA 92656 Fee Description Qtv Amount($) Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The Issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carded on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bidg_Permit Template.rpt Page 1 of 1 BUI LDI SAFETY •ERM IT/PLAN CHECK IT/.LA APPLICATION Menifee DATE PERMIT/PLAN CHECK NUMBER 1 �� TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILE HOME ❑POOL/SPA SIGN SUBTYPE: ❑✓ ADDITION ❑ALTERATION []DEMOLITION ❑ELECTRICAL ❑MECHANICAL ❑NEW ❑PLUMBING ❑RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit-Plan 2129-2.39 kW/9CS Master Solar Permit No.: PMT16-00910 PROJECT ADDRESS 30240 Bristol Gate Ln, Menifee,CA 92584 ASSESSOR'S PARCEL NUMBER �3641-36n-oy2 LOT 206 TRACT 30422-3 PROPERTY OWNER'S NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL leremiah.acayturri@lennar.com APPLICANT NAME Lennar Homes of California,Inc. ADDRESS 980 Montecito Dr.,suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S NAME Lennar Homes of California,Inc. OWNER BUILDER? ❑✓ YES❑NO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879 PHONE (951)8173680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ $6,328.72 S L SQ FT APPLICANT'S SIGNATURE DATE 04/06/2017 CITY STAFF USE ONLY DEPARTMENT DISTRIBUTION w^ CITY OF MENIFEE BUSINESS LICENSE NUMBER �BUILDING PLANNING ENGINEERING FIRE GREEN SMIP Tr INVOICE { PAIDAMOUNT AMOUNT {6 1 1 O CASH O CHECK# O CREDIT CARD VISA/MC PLAN CHECK FEES PAIDAMOUNT OCASH 0CHECK# 0CREDIT CARD VISA/MC OWNER BUILDER VERIFIED OYES O NO DLNUMBER NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION ....�� J\ BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MFR. MODEL Mike Dufault ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 2.385 KW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 9PLB. HYDNOAI HIS-5265RG(265W) Sr VP Opembons 1-101001133 ClassB BUYER:-----—---------------_ INVERTER. 9 PCS.1 ENPHASE I M215-60-2LL-S22-IG ROOF TYPE I CONCRETE TILE DATE:_---—----—---—----— TT-OF MENII SUB-ARRAY INFORMATION ARRAY#1 ARRAY#2 ARRAY#3 BUILDING ANI MOD OTY 9 NA NA BUYER: (}� /�1��TILT 23° NW NA° : -P AZIMUTH I70° NW NA. kM DATE APP OV City of Menifee Building Dept HVIEWE APR 2 7 2017 oval of thes plans Received e c e i v e d o .r. val of,any vi lation �l 3 6• L_Aiations and or linanci e until compl ation. ------ - ----- �a a� I PT - I SOLAD I r I � I TRANSI WIRE TRANSITIOIO N SOX (UNDER ARRAY) � + PV AL DISCONNECT EXTERIOR-GARAGE _ O UTILITY METER 6 MAIN SERVICE PANEL (VERIFIED BY BUILDER) NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF z PLAN 2129 ELEVATION C-R ORIENTATION 2 LOT*206 MAp LENNAR: ORIGINAL BY: KIM ABCOIIWER DATE:16.11.29 RIPOSA REVIEWED BY:SHAUN MARUNA - DATE:16-11.30 CORONNA.A.C CAA 92 AT THE LAKES 98o I DRIVE.#3oz 879 REV.# BY DATE DESCRIPTION �namaste ao... DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Bm dways"et INDIVIDUAL 30240 BRISTOL GATE LANE SoulEer,CO SM04 PLOT PLAN 1 1116'=1'-0' MENIFEE,CA 303A47.0300 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE,CA INV.MAKE INVERTER SPEC ENPHASE TEMP.AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INV.MODEL INVERTER SPEC M215-6D-2LL-S22-IG ^� TEMFrAMB(ENT_LOW(THIN) . , .ASHRAE.EXTR.MIN °C .. -2 INV.MAX,BOWER..(WAC MAX) INVERTER SPEC WATTS.(AC) .225 ,..... - TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V.(VBG MAX) INVERTER SPEC VOLTS(DC) 48 TEMP.DELTA LOW(TGELTA) THIN-TTEST °C -27 INV.OUTPUT V,(Vac NON) INVERTER SPEC VOLTS(Ac) 240 MOD- MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD. PART NUMBER MODULE SPEC HIS-S265RG INV.OUTPUT CURRENT.IAC INVERTER SPEC AMPS(Ac) 0.9 E� MOD. POWER STC(P) MODULE SPEC WATTS(oc) 265 INV.PHASE QUANTITY INVERTER SPEC PHASE I MOD. POWER PTC MODULE SPEC WATTS(00 238 COMPLIANCE INVERTER SPEC UL1741/IEEE1547 MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(oc) 31.30 INV. GROUNDING INVERTER SPEC ISOLATED MOD.OPEN CCT.VOLTAGE(Voc) MODULE SPEC VOLTS(oc) 38.10 INV, OTY.MAX/BRANCH CCT. INV.QTYBC OTY 9 MOD.COEFF. VOLT/TEMP(COEF) MODULE SPEC V/°C -0.114 BRANCH CCT-OUTPUT,(MANIC (IAC•INV.QTYBC) AMPS(AC) 9.10 MOD.MAX VOLTAGE(VMAX10D) (Vac+(TD•COEF)) VOLTS(oc) 41.18 INV. QUANTITY,TOTAL INV.OTYT OTY 9 MOD-OPERATING CURRENT(imp) MODULE SPEC AMPS(DC) 8.50 TOTAL SYSTEM OUTPUT,IMAXTS (IAC-INV.QTYT) AMPS(ACE 8.10 MOD.SHORT CCT.CURRENT(Isc) MODULE SPEC AMPS(DO 9.00 MOD. MAXIMUM CURRENT(TMAX) (ISO• 1.25) AMPS 00 11.25 MIN.AMPACITY REO'D,PER NEC (TMAX- 1.25) AMPS(m) 14.06 SERIES FUSE RATING,MAX MODULE SPEC AMPS(oc) 15 ELECTRICAL EQUIPMENT SCHEDULE a be con KEY OTY MANUFACTURER MODEL NOTES TRADE JV TOYISIOI 1 9 HYUNDAI MIS-S265RG (265W) PV MODULE SOLAR 2 9 ENPHASE M215-60-2LL-S22-IG PVINVERTER SOLAR N5 etofal 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 31? SOLAR 4 1 CUTLER-HAMMER DG22JURB PV AC DISCONNECT.NEMA 3R,24OV,30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR 8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS:I X ISA-IP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBD PV BREAKER.I X 2OA-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 I TBD TBD SERVICE PANEL,MIN. 125A BUS BLDR.ELEC. II 1 TBD T8D UTILITY METER,IPH. 120/240V.200A BLDR.ELEC. 12 TEO TBO GROUNDING ELECTRODE UFER BLDR.ELEC, 13 1 TBD I TBD I GROUNDING ELECTRODE,690.47(D) I SOLAR CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS 1)CONDITION OF USE(COU): (AMPACITY• TEMP.DEBATE• FILL DEBATE) VS.REO'D(TMAX) ITEM UNIT PANEL 2)TERMINALS(TERM): AMPACITY AT TERMINALS. VS-REO'D,(IMAX• 1.25) PANEL MFR. CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALL. AMPACITY W/O TEMP. FILL RESULT REO'D OCD BUS RATING AMPS 200 TYPE DERATES DEBATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 A #12 CU I THWN-2 i 30 0.76 1.0 22.80 B.10 ALLOWED PV PER NEC AMPS 40 TERM 25 25 10.13 20 pV OCPO DEVICE USED AMPS 20 B #10 CU NM-B COU 40 0.91 1.0 36.40 8.10 TERM 35 35 10.13 20 ^ C #10 CU NM-B COU 40 0.91 1.0 36.40 8.10 TERM I 35 35 10.13 20 k DUFauI( CONDUCTOR SCHEDULE Sr VP Ope atians KEY CONDUCTORS CU/AL I TYPE I LOCATION I TRADE Uc#1001133 UaaB A 1-412 ENGAGE CABLE, 146G.FREE AIR CU TC-ER ARRAY SOLAR B 3-#10, 1410 EGC CU NM-B(ROMEX) INTERIOR SOLAR C 3-#10, I-#10 EGC CU NM-B(ROMEX) INTERIOR SOLAR D CAT5E.ETHERNET CABLE CU CATSE INTERIOR SOLAR 5 6 II E 1-#6GEC.2010 CEC 690.47(D) CU BARE EXTERIOR SOLAR O B o 6 _ I M SEE NOTE 15 I IO 0 42G A/IP AO/2 3 G G GL ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.385 KW LOT#206 LENNAR: ORIGINAL BY: KIM ABCOUWER DATE:16.11.29 MARIPOSA REVIEWED BY:SHAUN MARUNA DATE:16.11.30 AT THE LAKES 9ORONA,80 A9287CITO RIVE,#302 CORONA,CA 92879 REV.# BY DATE DESCRIPTIONZa namaste SOLnR DWG TITLE: PAGE#: SCALE: SITE LOCATION: tsuat INDIVIDUAL d571 Ber.CO S N4 PLOT PLAN 2 NTS 3024D BRISTOL GATE LANE BO303.4C080304 ELECTRICAL MENIFEE,CA 303.447.0300 STRUCTURAL NOTES: Mike Duhul[ SOLAR CONTRACTOR- 5rVP0 peraHOns D ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 49'O.C. UGq 1001133 Ga55 B 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW.AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. ..,,. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKINO' ALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. ���� ��� 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL,VERSION 227.3.PUB 140113-ICC,JANUARY 2014, 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(10 SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND THE EDGE OF THE PV ARRAY 7 SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. ROOFING CONTRACTOR- 0 DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. - 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT 00 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE.DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE T BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE.BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO ''ib erml INSTALLATION. fel eral,stal ,d ns must I ELECTRICAL NOTES: GENERAL- D ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING.NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646.IEC61730. B)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING.SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT e. 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE:OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. LENNAR: ORIGINAL BY: KIM ABCOUWER DATE:16.11.29 MARIPOSA REVIEWED BY: SHAUN MARUNA DATE:16.11-30 AT THE LAKES CO NA.CA OR1vE,x3Dz CORONA,CA 92879 REV.B BY DATE DESCRIPTION •, Hama.... oue DWG TITLE: PAGE N: SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 30240 BRISTOL GATE LANE Boulder,CO 803N PLOT PLAN 3 NTS MENIFEE,CA NOTES 303.447.0300 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE r UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. lA ty v on the SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER S MAIN SERVICE PANEL (VERIFIED BY BUILDER) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE — AC SPECS AC OPERATING VOLTAGE: 240 V Mike Dufault sr VP Operations AC OPERATING CURRENT: 8.1 A °ck=OO13BB aassB NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION LENNAR: ORIGINAL BY: KIM ABCOUWER DATE:16.11.29 MARIPOSA" "' REVIEWED BY.'SHAUN MARUNA DATE:16.11.3O AT THE LAKES 9ORONA.80 A 92 DRIVE,#302 CORONA.CA 92W9 REV.# BY DATE DESCRIPTION .� d namaste SOLnR DWG TITLE: 7PAGESCALE: SITE LOCATION: treet INDIVIDUAL 4371 Ber.GO 304PLOT PLAN SCALE: MENIF BRISTOL GATE LANE Boulder. 7.0300 0 PLACARDS MENIFEE.CA 303.467.0300