Loading...
PMT17-01216 City of Menifee Permit No.: PMT17-01216 29714 HAUN RD. �CCELA7. MENIFEE,CA 92586 Type: Residential Electrical MENIFEE Date Issued: 0 4/2 712 01 7 PERMIT Site Address: 30228 BRISTOL GATE LN, MENIFEE,CA Parcel Number: 364-370-072 92584 Construction Cost: $6,328.72 Existing Use: Proposed Use: Description of SOLAR TR 30422-3 MARIPOSA Work: 9 MODULES,2.39KW LOT 205 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA,CA 92879 ATTN GOREEN MUELLER Applicant Phone:9493498269 JEREMIAH ACAYTURRI License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO,CA 92656 Fee Description City Amount(S) Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_SIdg_Permit Template.rpt Page 1 of 1 BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION Y. r Meni]ee DATE PERMIT/PLAN CHECK NUMBER 1 J© -'T'l.V TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY [:]MOBILE HOME POOL/SPA ❑SIGN SUBTYPE: ❑✓ ADDITION ❑ALTERATION ❑DEMOLITION ❑ELECTRICAL ❑MECHANICAL ❑NEW [—]PLUMBING ❑RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK SolarPermit-Plan 1769-2.39 kW/9CS Master Solar Permit No.:PMT16-00910 PROJECT ADDRESS 30228 Bristol Gate Ln, Menifee, CA 92584 ASSESSOR'S PARCEL NUMBER SO-370 -072 LOT 205 TRACT 30422-3 PROPERTY OWNER'S NAME Lerner Homes of California, Inc. ADDRESS 980 Montecito Dr.,suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL leremiah.acayturd@lennaccom APPLICANT NAME Lennar Homes of Califomia, Inc. ADDRESS 980 Montecito Dr.,suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL leremiah.arayturd@lennaccom CONTRACTOR'S NAME Lennar Homes of Califomia,Inc. OWNER BUILDER? ✓❑YES❑NO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Carona,CA 92879 PHONE (951)8173680 EMAIL leremiah.acayturri@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ $6.328.72 SO FT L SQ FT APPLICANT'S SIGNATURE DATE 04l06/2017 . CITY STAFF USE NLY P DEPARTMENT DISTRIBUTION W �r(1 CITY OF MENIFEE BUSINESS I.ICEN5E NUMBER BUILDING PLANNING ENGINEERING fIRE GREEN I SMIP VUoo INVOICE I PAIDAMOUNT AMOUNT + OCASH CCHECKH OCREDn CARD VISA/MC PLAN CHECK FEES PAIDAMOUNT 0CASH 0CHECK# OCREDITCARD VISA/MC OWNER BUILDER VERIFIED OYES O NO DL NUMBER NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION J BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MFR. MODEA(265W) Mike�uhUlt ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 2.385 KW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 9PCS. HYUNDAI HIS-S 57VPOper33 Cl Ucq 1001333 Class B BUYER: --- — �. INVERTER- 9 PLS. ENPHASE M215- ,.. . . 1. . . ROOF TYPE I CONCRETE TILE DATE:_ 'y SUB-ARRAY INFORMATION I ,r OF MEN ARRAY#I ARR AY#2 ARRAY#3 MOD OTY 9 NA NA BUYER: ��1„t DIN A� TILT 23° NA° NA° DATE: AZIMUTH 260° NA° NA° }. ' O City of Menifee _ L Building Dept }{E� APR 2 7 2017 nr.,tial of t Ese pla Received roval of,an I violat ,sulationsant ordim abme until co npletic - - --� I ' I i I SOLADECK WIRE 16'-5'ARRAY TRANSITION BOX----. 17'-3'FLASHING Is, (UNDER ARRAY) I PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER 8 } ... MAIN SERVICE PANEL VERIFIED BY BUILDER) � � - --- - -- -� •I1111111111111, r P- NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF z® PLAN 1769 ELEVATION A ORIENTATION 2 LO #205 LENNAR: ORIGINAL BY: KIM ABCOUWER DATE:Ifi.11.29 MARIPOSA I[ REVIEWED BY:SHAUN MARUNA DATE:16,11.30 AT THE LAKES 980 NA,CA DRIVE,#302 CORONA,CA 92879 REV.# BY DATE DESCRIPTION namasbe some DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 30228 BRISTOL GATE LANE B.Ider,CO 80304 PLOT PLAN 1 1116'=I'-0' MENIFEE,CA 303.447.0300 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE,CA INV.MAKE INVERTER SPEC ENPHASE TEMP;AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INV.MODEL INVERTER SPEC M215-60-2LL-SZ2-IG TEMP,AMBIENT.LOW.(THW) ...ASHRAE EXTR.MIN °C -2 INV.MAX POWER-DVAQ.MAX),-. INVERTER SPEC WATTS(Ac), 225 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V,(Voc MAX) INVERTER SPEC VOLTS(at) 48 TEMP.DELTA LOW(TDELTA) THIN-TTEST °C. -27 INV.OUTPUT V.(VAc NON) INVERTER SPEC VOLTS(AC) 240t— MIN.MOD. MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD.PART NUMBER MODULE SPEC HIS-S265RG INV.OUTPUT CURRENT,IAc INVERTER SPEC AMPS(AC) 0.9 MOD.POWERSTC(P) MODULE SPEC WATTS(oc) 265 INV.PHASE QUANTITY INVERTER SPEC PHASE IMOD.POWERPTC MODULE SPEC WATTS(DC) 238 COMPLIANCE INVERTER SPEC UL1741/IMOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(Dc) 31.30 INV.GROUNDING INVERTER SPECMOD.OPEN CCT.VOLTAGE(VI MODULE SPEC VOLTS(oc) 38.10 INV.OTY.MAX/BRANCH CCT. INV.QTYecOTY 9 MOD.COEFF.VOLT/TEMP(COEF) MODULE SPEC V/°C -0.114 BRANCH CCT.OUTPUT,IHAXBC (IAc°INV.QTYBC) AMPS(AC) B.10 MOD.MAX VOLTAGE(VMAXMOO) (VOC♦(TO°COEF)) VOLTS(oc) 41.18 INV.QUANTITY,TOTAL INV.QTYT OTY 9 MOD.OPERATING CURRENT(IMP) MODULE SPEC AMPS(oc) 8.50 TOTAL SYSTEM OUTPUT, IMAXTS (IAC•INV.QTYT) AMPS(AD) B.10 MOD.SHORT CCT.CURRENT QBC) MODULE SPEC AMPS(DC) 9.00 MOD. MAXIMUM CURRENT(IMAX) (ISc° 1.25) AMPS(oc) 11.25 AMPACITY REO'D,PER NEC (IMAX- 1.25) AMPS(Oc) 14.06 SERIES FUSE RATING,MAX MODULE SPEC AMPS(oc) 15 ° ELECTRICAL EQUIPMENT SCHEDULE Al :othe( KEY OTY -MANUFACTURER MODEL NOTES TRADE 1 9 HYUNDAI MIS-S265RG(265W) PV MODULE SOLAR ))al ay prove! 2 9 ENPHASE M215-60-2LL-S22-IG PV INVERTER SOLAR 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 'S, T IS Seto 4 1 CUTLER-HAMMER DG221URS PV AC DISCONNECT,NEMA 3R.24OV,30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR, 120V SOLAR 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR 8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS;I x ISA-IP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBD PV BREAKER.I x 2OA-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 1 TO TBD SERVICE NEL.MIN. 125A BUS BLDR.ELEC. II I TBD TBD UTILITY MEPATER,IPH.120/24OV,200A BLDR.ELEC. 12 I TBD TBD I GROUNDING ELECTRODE UFER BLDR.ELEC. 13 1 1 TBD TBD I GROUNDING ELECTRODE,690.47(D) SOLAR CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS 1)CONDITION OF USE(COU): I (AMPACITY•TEMP.DERATE-FILL DERATE) VS.REO'D(IMAX) ITEM UNIT PANEL 2)TERMINALS(TERM I AMPACITY AT TERMINALS. VS.REQ'D,(IMAX° 1.25) PANEL HER. CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REO'D OCD BUS RATING AMPS 200 TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 A #12 CU THWN-2 COU 30 0.76 1.0 22.80 8.10 ALLOWED PV PER NEC AMPS 40 TERM 25 25 10.13 20 PV OCPD DEVICE USED AMPS 20 B #10 CU NM-B COU 40 0.91 1.0 36.40 8.10 TERM 35 35 10.13 20 C #10 CU NM-B COU 40 0.91 1.0 36.40 8.10 ,°,.'�\� TERM 35 35 10.13 20 Mike Default CONDUCTOR SCHEDULE Sr vP ope atl0ns KEY CONDUCTORS I CU/AL TYPE I LOCATION I TRADE Uc#1001333 Uass B A 1-#I2 ENGAGE CABLE, 146G.FREE AIR CU LC-ER SOLAR B 34H0, 1-#10 EGC CU NM-B(ROMEX) INTERIOR SOLAR C 3410, 14I0 EGG I CU I NM-B(ROMEX) I INTERIOR SOLAR D CATSE,ETHERNET CABLE I CU I CAT5E I INTERIOR SOLAR 5 6 II E I-#6GEC,2010 CEC 690.470) 1 CU I BARE I EXTERIOR SOLAR OjISo M — SEE NOTE 15 10 Q ISA/IP O O O O 200./RP jccipl ` 4141191 A LIN 1 I I ROOF EXTERIOR-GARAGE I ELECTRICAL DIAGRAM 2.385 xW LOT#205 ORIGINAL BY: KIM ABCOUWER I DATE:16.11.29 MARIPOSA LENNAR: REVIEWED BY:SHAUN MARUNA I DATE:16.11.30 980 MONTECITO DRIVE.#302 AT THE LAKES CORONA.CA 92879 REV.# BY DATE DESCRIPTION •V namasG6 SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Bm dmy Street INDIVIDUAL 3022E BRISTOL GATE LANE BaulL r,CO 80304 PLOT PLAN 2 NTS MENIFEE,CA 303.447.0300 ELECTRICAL STRUCTURAL NOTES: Mike Dutaul[ SOLAR CONTRACTOR- $�VP Oper4N0R5 p ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. U[#1001133 CIa558 ' ..-?)ALL PV ROOF,ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST.SHE RDOE-FRAM�ING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. .--,.... _ 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WICL'BE SEAfU_;FI APPROVED SEALANT. 4)SOLAOECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS, IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3-ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL,VERSION 227.3.PUB 14OU3-ICC.JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH Q')SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(Z')BEYOND THE EDGE 'I] ART OF THE PV ARRAY/SUB-ARRAY. 6)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40% ROOFING CONTRACTOR- 1)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 31. 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION.IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT W)OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. ' 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE.BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. (Ito bea of the fedel :ro red plan! ELECTRICAL NOTES: GENERAL- I)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. IU MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. IL)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT}. 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE:OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. MARIPOSA LENNAR: ORIGINAL BY: KIM ABCOUWER DATE:16,11.29 980 MONTECITO DRIVE,•#302 REVIEWED BY: SHAUN MARUNA DATE:16.11.30 AT THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION •� �namaste DWG TITLE: PAGE#: I SCALE: SITE LOCATION: mel INDIVIDUAL 4S11&a.CO 04 PLOT PLAN 3 NTS 3022E BRISTOL GATE LANE Ba303.4 7. 80304 NOTES MENIFEE,CA 303.44].0300 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE LENT UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. ( a (ate or city st be kept on the SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER& MAIN SERVICE PANEL (VERIFIED BY BUILDER) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V Mike Dufault Sr VP Operations AC OPERATING CURRENT: 8.1 A Lc#1003133 Classe NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION LENNAIR ORIGINAL BY: KIM ABCOUWER DATE:16.11.29 MARIPOSA - REVIEWED BY:SHAUN MARUNA- DATE:16.11.30 980 MONTECITO DRIVE,#302 AT THE LAKES CORONA.CA 92879 REV.# BY DATE DESCRIPTION to namasCe It-- .o.,. DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Slreal INDIVIDUAL 30228 BRISTOL GATE LANE Boulder,CO BM04 PLOT PLAN 4 NTS MENIFEE,CA 303.447.0300 PLACARDS