Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
PMT17-01214
City of Menifee Permit No.: PMT17-01214 29714 HAUN RD. �CCEL/? MENIFEE,CA 92586 Type: Residential Electrical MENIFEE Date Issued: 0 4/2 712 0 1 7 PERMIT Site Address: 30249 BRISTOL GATE LN,MENIFEE,CA Parcel Number: 364-360-028 92584 Construction Cost: $6,328.72 Existing Use: Proposed Use: Description of SOLAR TR 30422-3 MARIPOSA Work: 9 MODULES,2.39KW LOT 58 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA,CA 92879 ATTN GOREEN MUELLER Applicant Phone:9493498269 JEREMIAH ACAYTURRI License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO,CA 92656 Fee Description Otv Amount($1 Solar,Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing building operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Template.rpt Page 1 of 1 BUILDING & SAFETYPERMIT/PLAN CHECK APPLICATION .."Menifee DATE PERMIT/PLAN CHECK NUMBER 1 1� c/ a� TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL MULTI-FAMILY ❑MOBILEHOME POOL/SPA []SIGN SUBTYPE: ❑✓ ADDITION ❑ALTERATION []DEMOLITION []ELECTRICAL ❑MECHANICAL ❑NEW ❑PLUMBING ❑RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit-Plan 1924-2.39 kW/9CS Master Solar Permit No.: PMT16-00910 PROJECTADDRESS 30249 Bristol Gate Ln, Menifee,CA92584 ASSESSOR'S PARCEL NUMBER y— Q �OZQ LOT 58 TRACT 30422-3 PROPERTY OWNER'S NAME Lennar Homes of California,Inc. C.� ADDRESS 980 Montecito Dr.,suite 302,Carona,CA 92879 PHONE (951)817-3680 EMAIL leremiah.acayturd@lennar.com APPLICANT NAME Lennar Homes of California,Inc. ADDRESS 980 Montecito Dr.,suite 302,Corona, CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? ❑✓ YES❑NO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL leremiah.acayturri@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ $6,328.72 S L SQ FT APPLICANT'S SIGNATURE DATE 04/06/2017 CITYSTAFF USE ONLY DEPARTMENT DISTRIBUTION CAI CIN OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN SMIP UUVV INVOICE PAIDAMOUNT AMOUNT O CASH O CHECK# O CREDIT CARD VISA/MC PLAN CHECK FEES PAIDAMOUNT 0CASH 0CHECK# OCREDITCARD VISA/MC OWNER BUILDER VERIFIED OYES O NO DL NUMBER NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Department 29714 Houn Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION J BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MFR. MODEL Milk DUYdult ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 2.385 KW SrVP LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 9PCS. HYUNDAI HIS-S265RG(265W) U0100133 Cs UN SOO1133 ClassB BUYER: _ INVERTER, 9PCS. ENPHASE M215-60-2LL-522-IG ROOF TYPE I CONCRETE TILE DATE: SUB-ARRAY INFORMATION ARRAY#I ARRAY#2 ARRAY#3 Cl i TP vr' EN MOD OTY 9 NA NA BUYER: TILT 23° 1 NA' I NM r ) flf D AZIMUTH 265° NA' NA' DATE: I City of Menifee .;1N AP R01 Building Dept APR 2 7 2i ;i "",IJEWE Q e^ ,r �,r�' 3 ` ` rrn•ovalofthese plans 3' 1T-3•FLASHING ^"`Uvalofa / ny vio ation( Ilat(ons and ord antes ce until comple 'on. I i I i I I I SOLADECK WIRE TRANSITION 8O% (UNDER ARRAY) I { 4 PV AC DISCONNECT E%TERIOR-GARAGE — — — UTILITY METER 8 1 MAIN SERVICE PANEL L J I (VERIFIED BY BUILDER) ----- —Z- --� ✓ NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF ®z PLAN 1924 ELEVATION C-R ORIENTATION 4 LO #58 ORIGINAL BY: KIM ABCOUWER DATE:16.1129. MARIPOSA LENNAR: REVIEWED BY:SHAUN MARUNA DATE:16.11.30 AT THE LAKES 980 MONTECITO DRIVE,#302 CORONA,CA 92879 REV.# BY DATE DESCRIPTION .� namasc6 .o,.. DWG TITLE: PAGE#: SCALE: SITE LOCATION: Street INDIVIDUAL 4571lder,CBroadway 30249 BRISTOL GATE LANE Bo 304 PLOT PLAN 1 1/16•=V-0• 301. 170300 SYSTEM LAYOUT MENIFEE,CA MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE /CALC UNIT DETAIL LOCATION MENIFEE,CA INV. MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 . INV. MODEL INVERTER SPEC M215-60-2LL-S22-IG TEMP,AMBIENT LOW(TMIN) ASHRAE EXTR..MIN 9C -2.. _, INV.MAX POWER,(WAC MAX) INVERTER SPEC_ WATTS(AC) 225 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V,(Voc MAX) INVERTER SPEC VOLTS D[ 48 TEMP,DELTA LOW(TDELTA) TMIN-TTEST °C -27 INV. OUTPUT V.(VAC NOM) INVERTER SPEC VOLTS(AC) 240 MOD.MANUFACTURER MODULE SPEC HYUNDAI INV. OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD.PART NUMBER MODULE SPEC HIS-S265RG INV. OUTPUT CURRENT,IAC INVERTER SPEC AMPS(AC) 0.9 MOD.POWER STC(P) MODULE SPEC WATTS(00 265 INV.PHASE QUANTITY INVERTER SPEC PHASE I L MOD.POWER PTC MODULE SPEC WATTS(oc) 238 COMPLIANCE INVERTER SPEC UL1741/IEEE1547 MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(oc) 31.30 INV.GROUNDING INVERTER SPEC ISOLATED YET MOD.OPEN CCT.VOLTAGE(V00 MODULE SPEC VOLTS(m) 38.10 INV.OTY,MAX/BRANCH CCT. INV.0 YBC1 OTY 19 MOD.COEFF.VOLT/TEMP(COEF) MODULE SPEC V/°C -0.114 BRANCH CCT. OUTPUT,IMAXBC I (IAC•INV.QTYBC) I AMPS(AC) 18.10 MOD.MAX VOLTAGE(VMAXMOD) (Voc+(TD-COEF)) VOLTS 00 41.18 INV.QUANTITY,TOTAL I NV.OTYT I OTY 19 MOD.OPERATING CURRENT(IMP) MODULE SPEC AMPS(Dc) 8.50 TOTAL SYSTEM OUTPUT.IMAXTS I (IAC-INV.QTYT) I AMPS(AC) 18.10 MOD.SHORT CCT. CURRENT(ISC) MODULE SPEC AMPS(DU 9.00 MOD. MAXIMUM CURRENT(]MAX) (ISC•1.25) AMPS(DG) 11.25 MIN.AMPACITY REO'D,PER NEC (IMAX° 1.25) AMPS(00 14.06 SERIES FUSE RATING,MAX MODULE SPEC AMPS(DC) 15 ELECTRICAL EQUIPMENT SCHEDULE KEY OTY MANUFACTURER MODEL NOTES TRADE 1 9 HYUNDAI HIS-S265RG(26SW) PV MODULE SOLAR 2 9 ENPHASE M215-60-2LLS22-IG PV INVERTER SOLAR no be con 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 4 I CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R.24OV.30A SOLAR Tyr rovisior 5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR 1is et of a 6 1 TBD TBD I20V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR P 7 I TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR 8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS: I x 15A-IP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBD PV BREAKER.I x 2OA-2P.LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 1 I 1 TBD TBD SERVICE PAN MIN. 125A BUS BLDR.ELEC. II I TBD TBD UTILITY METER,EL,IPH,120/240V.200A BLDR.ELEC. 12 I TBD TBD GROUNDING ELECTRODE UFER BLDR.ELEC. 13 1 1 TBD T80 I GROUNDING ELECTRODE,690.47(D) I SOLAR CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS 1)CONDITION OF USE(COU): (AMPACITY-TEMP. DERATE'FILL DERATE) vs.REO'D(IMAX) ITEM UNIT PANEL 2)TERMINALS(TERM): AMPACITY AT TERMINALS. vs.REQ'D,(IMAX• 1.25) PANEL HER. CUTLER-HAMMER KEY 512E LU/AL INSULATION CALC. AMPACIT TEMP. FILL RESULT REQ'D OCD BUS RATING AMPS 200 TYPE DERATESY W/0 DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 A #12 CU THWN-2 COU 30 0.76 1.0 22.80 8.10 ALLOWED PV PER NEC AMPS 40 TERM 25 25 10.13 20 PV OCPD DEVICE USED AMPS 20 B #10 CU NM-S COU 40 0.91 1.0 36.40 8.10 TERM 35 35 10J3 20 ^ C #10 C NM-B I COU 40 0.91 1.0 36.40 8.10 .��\ / TERM 35 35 10.13 20 Mike Dufault CONDUCTOR SCHEDULE Sr VP Ope ations KEY CONDUCTORS CU/AL TYPE LOCATION TRADE Uc#1001133 Gau B A 1412 ENGAGE CABLE, 146G.FREE AIR 1 C TC-ER ARRAY SOLAR B 3-#10, 1-#10 EGC LU NM-8(ROMEX) INTERIOR SOLAR C 3-#10, I-#10 EGC I CU I NM-B(ROMEX) I INTERIOR SOLAR D CAT5E,ETHERNET CABLE CU CAT5E INTERIOR SOLAR 5 © II E 1-06GEC,2010 CEC 690.47(D) CU BARE EXTERIOR SOLAR O o ® M SEE NOTE 15 1I 10 O ISAIIP O O 10M 3 AlG G G I I I ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.385 KW LOT#58 LENNAR: ORIGINAL BY: KIM ABCOUWER DATE:16.11.29 MARIPOSA 980 MONTECITO DRIVE,-#302 REVIEWEDBY:SHAUN MARUNA DATE:16.11.3➢. � AT THE LAKES CORONA:CA 92879 REV.# BY DATE I DESCRIPTION Qunamaste SOl/R DWG TITLE: PAGE#: SCALE: SITE LOCATION: 45/1 BrOadwaySWel INDIVIDUAL 30249 BRISTOL GATE LANE Boulder,CO 80304 PLOT PLAN 2 NTS ELECTRICAL MENIFEE,CA 303.447.03M t STRUCTURAL NOTES: Mike 0ufaul SOLAR CONTRACTOR- Sr VP Opmtt00s 1)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. Utl)1001133 Class B 2)ALL PV ROOF..ATTACHMENTS WILLSESTAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS.TO,MAXIMUM EXTENT.POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS.IT WILL BE FLASHED AND SEALED- 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE, 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL,VERSION 227.3,PUB 140113-ICC,JANUARY 2014, 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(I-)SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. D PAR 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN AD'. ai ROOFING CONTRACTOR- 0 DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL HE A MINIMUM OF 3% 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL7 TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(I')OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE, 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE.BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. 'd obeap, ;b fed eral, Jed plansmi ELECTRICAL NOTES: GENERAL- D ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEL61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 12UV BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT e. 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED*PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. p LENNAR: ORIGINAL BY: KIM ABCOUWER DATE:16.11.29 MARIPOSA 980 MONTEL DRIVE.#302 REVIEWED BY. SHAUN MARUNA DATE:16.11.30 CORONA.CA AT THE LAKES 9O 92879 REV-# BY DATE IDESCRIPTION •, a nama=6 DWG TITLE: PAGE,#: SCALE: SITE LOCATION: 4571 Broadway Sheet INDIVIDUAL 30249 BRISTOL GATE LANE Baulder,C0803D4 PLOT PLAN 3 NTS NOTES MENIFEE,CA 303.447.030D CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. RENT `or,or an 'e or city )e kept on th SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER B MAIN SERVICE PANEL (VERIFIED BY BUILDER) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE — AC SPECS AC OPERATING VOLTAGE: 240 V Mike Dufault Sr VP Operations AC OPERATING CURRENT: 8.1 A lICW 1001133 ClassB NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY: KIM ABCOUWER DATE:16.11.29 MARIPOSA LENNAR: REVIEWED BY:SHAUN MARUNA DATE:16.11.30 AT THE LAKES CO NA.CA I92TO DRIVE,#302 CORONA,CA 92879 REV.# BY DATE DESCRIPTION to namaste DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 4571 Bm dv yStreet INDIVIDUAL 30249 BRISTOL GATE LANE Boulder,CO SD304 PLOT PLAN 4 NTS MENIFEE.CA 301. 7.0300 PLACARDS