Loading...
PMT17-01213 City of Menifee Permit No.: PMT17-01213 29714 HAUN RD. <ACCELA? MENIFEE,CA 92586 Type: Residential Electrical MENIFEE Date Issued: 04/27/2017 PERMIT Site Address: 30261 BRISTOL GATE LN,MENIFEE,CA Parcel Number: 364-360-027 92584 Construction Cost: $6,328.72 Existing Use: Proposed Use: Description of SOLAR TR 30422-3 MARIPOSA Work: 9 MODULES,2.39KW LOT 57 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA,CA 92879 ATTN GOREEN MUELLER Applicant Phone:9493498269 JEREMIAH ACAYTURRI License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO,CA 92656 Fee Description Opt f Amount(El Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing building operations being cabled on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Pennit_Template.rpt Page 1 of 1 BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION Menifee DATE PERMIT/PLAN CHECK NUMBER f TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILEHOME ❑POOL/SPA ❑SIGN SUBTYPE: ❑✓ ADDITION []ALTERATION []DEMOLITION ❑ELECTRICAL []MECHANICAL ❑NEW ❑PLUMBING ❑RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit-Plan 2129-2.39 kW l 9CS Master Solar Permit No.: PMT16-00910 PROJECTADDRESS 30261 Bristol Gate Ln,Menifee,CA92584 ASSESSOR'S PARCEL NUMBER 30_ 3G1-027 LOT 57 TRACT 30422-3 PROPERTY OWNER'S NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com APPLICANT NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S NAME Lerner Homes of California, Inc. OWNER BUILDER? ❑✓ YES ONO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ $6,328.72 L SQ FT APPLICANT'S SIGNATURE DATE 04/06/2017 CITY STAFF USE ONLY DEPARTMENT DISTRIBUTION I ..1� 1� CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN SMIP fl INVOICE PAID AMOUNT AMOUNT O CASH O CHECK# O CREDIT CARD VISA/MC PLAN CHECK FEES PAIDAMOUNT 0CASH OCHECK# OCREDIT CARD VISA/MC OWNER BUILDER VERIFIED O YES O NO DL NUMBER NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION J\ BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY 1 MFR. MODEL Mike Duhult ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 2.385 KW LOCATIONS INDICATED BY THE ILLUSTRATION. ns MODULE 9 PCS. HYUNDAI HIS-S265RG (265W) STV1001133 Cl LIc#1(101133 ClassB BUYER:_— INVERTER I 9PCS.1 ENPH4SE I M215-60-2LL-522-IG ROOF TYPE I CONCRETE TILE DATE:— - _ - - - — - _____- - —- SUB-ARRAY INFORMATION ARRAY#1 ARRAY#2 ARRAY#3 MOD OTY 9 NA NA BUYER: TILT 23° NA' NV AZIMUTH 175° NA' NA' DATE: City of Menifee LITY F P Building Dept C.I INS APR 2 7 2017 PLAN APF Received REVIE EI `4nproval fthesl i zPr%alol any vi a g regulations and on m :obsite unti comp) I I I I I � I I I I I I I I I SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) I I PV AC DISCONNECT + EXTERIOR-GARAGE UTILITY METER O MAIN SERVICE PANEL (VERIFIED BY BUILDER) NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF ®z PLAN 2129 ELEVATION A ORIENTATION 4 LO #57 LENNARi ORIGINAL BY: KIM ASCOUWER DATE:16.11.29 MARIPOSA REVIEWED BY:SHAUN MARUNA I DATE:16.11.30 AT THE LAKES 980 MONTECI DRIVE,#302 92 CORONA,CA 92879 REV.# BY DATE DESCRIPTION •� namasbe SOt�R DWG TITLE: PAGE#: SCALE: SITE LOCATION: ireet INDIVIDUAL 4571 Ber,CO8 304 30261 BRISTOL GATE LANE Boulder,C080304 PLOT PLAN I I/16'=I'-0' MENIFEE,CA 303.44].0300 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE.CA INV. MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH(TMAX) ASHRAE2% °C 37 INV.MODEL INVERTER SPEC M215-60-2LL-S22-IG TEMP,AMBIENT.LOWdTMIN), ASHRAE EXTR.MIN. °C -2 INV.MAX POWER..(WAC MAX)i INVERTER SPEC WATTS(AC) 225 TEMP,MODULE TEST(TTEST MODULE SPEC °C 25 INV. INPUT V. (VDC MAX) INVERTER SPEC VOLTS(DC) 48 TEMP,DELTA LOW(TOELTA) THIN-TTEST °C -27 INV. OUTPUT V.(VAC NOM) INVERTER SPEC VOLTS(AC) 240 MOD.MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD.PART NUMBER MODULE SPEC HIS-S265RG INV.OUTPUT CURRENT,IAC INVERTER SPEC AMPS(AC) 0.9 MOD.POWER STC(P) MODULE SPEC WATTS(DC) 265 INV.PHASE QUANTITY INVERTER SPEC PHASE I MOD.POWER PTC MODULE SPEC WATTS(CC) 238 COMPLIANCE INVERTER SPEC UL1741/IEEE1547 MOD. OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(oc) 31.30 INV.GROUNDING INVERTER SPEC ISOLATED MOD. OPEN CCT.VOLTAGE(VOC) MODULE SPEC VOLTS(D) 38.10 INV.CITY,MAX/BRANCH CCT. MV ATYBC OTY 9 1 WFE MOD.COEFF. VOLT/TEMP(COEF) MODULE SPEC V/°C -0.114 BRANCH CCT.OUTPUT, IMAXRC I (IAC-INV.QTYBC) AMPS(AC) 8.10 MOD.MAX VOLTAGE(VMAXMOD) (Voa+(TD-COEF)) VOLTS(m) 41.18 INV.QUANTITY,TOTAL I INV.OTYT OTY 9 FET MOD. OPERATING CURRENT(IMP) MODULE SPEC AMPS(DC) B.SO TOTAL SYSTEM OUTPUT,IMAXTS (IAC'INV.OTYT) AMPS(Ac) 8.10 MOD. SHORT CCT. CURRENT(ISC) MODULE SPEC AMPS(CC) 9.00 MOD. MAXIMUM CURRENT QMAX) (ISC. 1.25) AMPS(ue) 11.25 OVAL '� 1 MIN.AMPACITY REO'D,PER NEC (IMAX• 1.25) AMPS(CC) 14.06 AL SERIES FUSE RATING,MAX MODULE SPEC AMPS(DC) 15 ELECTRICAL EQUIPMENT SCHEDULE KEY OTY MANUFACTURER MODEL NOTES TRADE 1 9 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR 2 9 ENPHASE M215-60-2LL-S22-IG PVINVERTER SOLAR 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221LRB PV AC DISCONNECT,NEMA 3R,24OV,30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR i0i shall n 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR be col 7 1 TBD TBD CATS PORT FOR.SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR ion of any rOV1s10 8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS:I X I5A-IP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBD PV BREAKER, I x 2OA-2P,LOCATE AT OPPOSITE ENO OF BUS FROM MAIN BREAKER SOLAR Ines. This et of a ID 1 TBD TBD SERVICE PANEL,MIN. 125A BUS BLDR.ELEC. II I TBD TBD UTILITY METER,IPH,120/24OV,200A BLDR.ELEC. n. 12 I TBD TBD I GROUNDING ELECTRODE UFER BLDR.ELEC. 13 1 I 1 TBD I TBD I GROUNDING ELECTRODE,690.47(D) SOLAR CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS 1)CONDITION OF USE(COU): (AMPACITY-TEMP. DERATE. FILL DERATE) Vs.REWD(IMAX) ITEM UNIT PANEL 2)TERMINALS(TERM): AMPACITY AT TERMINALS. VS. REQ'D,(IMAX. 1.25) PANEL HER. CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REO'D OCD BUS RATING AMPS 200 TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 A #12 CU THWN-2 COU 30 0.76 1.0 =22.808.10 ALLOWED PV PER NEC AMPS 40 TERM 25 20 PV OCPD DEVICE USED AMPS 20 #10 CU NM-B COU 40 0.91 LO TERM 35 20 C "0 CU NM-B COU 40 0.91 1.0 TERM 35 Mike Dufaul[ CONDUCTOR SCHEDULE sr vM ope ations KEY CONDUCTORS CU/AL TYPE LOCATION TRADE ❑C#1001133 ❑as58 A I-#12 ENGAGE CABLE.I-#6G,FREE AIR g TC-ER ARRAY SOLAR B 3-lt10, E#10 EGC NM-B(ROMEX) INTERIOR SOLAR C 3-#10, 1-#10 EGC NM-a(ROMEX) INTERIOR SOLAR D CAT5E,ETHERNET CABLE CAT5E INTERIOR SOLAR 5 6 II E -#6GEC.2010 GEC 690.47(D) CU BARE EXTERIOR SOLAR O p IS M SEE NOTE 15 10 Q 1 0 O' ® "Al P 3 ]N G GT=0 G Ja B ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.385 RW LOT#57 LENNAR: ORIGINAL BY: KIM ABCOUWER DATE:16.11.29 MARIPOSA. .... 980 MONTECITO DRIVE,#302 REVIEWED BY:SHAUN MARUNA I DATE:16.11.30 AT THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION Z 2namaste SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 30261 BRISTOL GATE LANE Boulder,CO B0304 PLOT PLAN 2 NES MENIFEE,CA ELECTRICAL 303.447.0300 �.��� STRUCTURAL NOTES: Mike 0ufaul[ SOLAR CONTRACTOR- Sr VP Openitlons - 1)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48,O.C. UCM 1001133 OUS B .- 2,)-ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROG.:ERAMI G.MEMBERS,TO MAXIMUM.EXTENT POSSIBLE. �3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL-BEALEO wTTI? f APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS.IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3-ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL,VERSION 227.3.PUB 140113-ICC.JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(19 SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(Z.)BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. ROOFING CONTRACTOR- 1)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. ��� ��� 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL-TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION, IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(1')OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE. PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE.BIRDSTOP TO BE SPECIFIED BY ROOFER PR10R TO INSTALLATION. - 5 m 4aple'tobe ELECTRICAL NOTES: :f the J decal,si GENERAL- wed ans mus U ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING.NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE U1_1703,IEC61646,IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING.OR MANUFACTURER'S RECOMMENDATIONS. IL)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING /PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT A% 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10', BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. LENNAR: ORIGINAL BY: KIM ASCOUWER DATE:16.11.29 MARIPOSA REVIEWED BY: SHAUN MARUNA DATE:16.11.30 AT THE LAKES CO NA.CA I92 DRIVE:#302 CORONA.CA 92079 REV.# BY DATE I DESCRIPTION namaste .Al.e DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Slmel INDIVIDUAL 30261 BRISTOL GATE LANE Boulde9 CO 80304 PLOT PLAN 3 NTS MENIFEE,CA 303.447.0300 NOTES CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. 'NT ❑ . .ATEATE or city kept on the SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER B MAIN SERVICE PANEL (VERIFIED BY BUILDER) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V Sr1VPOperdlbons AC OPERATING CURRENT: 8.1 A UO#1001133 ClassB NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ., ORIGINAL BY: KIM ABCOUWER DATE:16.11.29 MARIPOSA �ENNAR:, 480 MONTECITO DRIVE,#302 REVIEWED BY:SHAUN MARUNA I DATE:16.11.30 AT THE LAKES CORONA,CA 92879 REV.# BY DATE I DESCRIPTION 0 namasbe I It- soue DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 4Bo Broadway 304 PLOT PLAN 4 NTS 30261 BRISTOL GATE LANE BO3D3. C030304 PLACARDS MENIFEE,CA 303.447.0300