Loading...
PMT17-01212 City of Menifee Permit No.: PMT17-01212 29714 HAUN RD. <A-CCELA— MENIFEE, CA92586 Type: Residential Electrical MENIFEE Date Issued: 04/27/2017 PERMIT Site Address: 30273 BRISTOL GATE LN,MENIFEE, CA Parcel Number: 364-360-026 92584 Construction Cost: $6,328.72 Existing Use: Proposed Use: Description of SOLAR TR 30422-3 MARIPOSA Work: 9 MODULES,2.39KW LOT 56 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA,CA 92879 ATTN GOREEN MUELLER Applicant Phone:9493498269 JEREMIAH ACAYTURRI License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALSO VIEJO,CA 92656 Fee Description city Amount($l Solar,Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing building operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Peonit_Template.rpt Page 1 of 1 CUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION I° Menifee DATE PERMIT/PLAN CHECK NUMBER t � TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILE HOME ❑POOL/SPA []SIGN SUBTYPE: ❑✓ ADDITION []ALTERATION ❑DEMOLITION ❑ELECTRICAL ❑MECHANICAL ❑NEW ❑PLUMBING ❑RE-ROOF-NUMBEROFSQUARES DESCRIPTION OF WORK Solar Permit-Plan 1924-2.39 kW/9CS Master Solar Permit No.:PMT16-00910 PROJECTADDRESS 30273 Bristol Gate Ln,Menifee,CA 92584 ASSESSOR'S PARCEL NUMBER LOT 56 TRACT 30422-3 PROPERTY OWNER'S NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,suite 302, Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com APPLICANT NAME Lennar Homes of California,Inc. ADDRESS 980 Montecito Dr.,suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturd@lennar.com CONTRACTOR'S NAME Lennar Homes of Califomia,Inc. OWNER BUILDER? ❑✓ YES❑NO BUSINESS NAME Lennar Homes of Califomia, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturd@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ $6,328.72 L SQ Ff APPLICANT'S SIGNATURE ATE 04/06/2017 DEPARTMENT DISTRIBUTION � CITYOFMENIFEEBUSINESSLICENSENUMBEK BUILDING PLANNING ENGINEERING FIRE GREEN SMIP INVOICE PAID AMOUNT AMOUNT � 0CASH 0 CHECK# 0CREDIT CARD VISA/MC PLAN CHECK FEES PAID AMOUNT 0CASH 0CHECK# OCREDIr CARD VISA/MC OWNER BUILDER VERIFIED OYES C NO DL NUMBER NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us inspection Request Line 951-246-6213 SYSTEM INFORMATION J BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY HER. MODEL Mike DUYdult ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 2.385 KW LOCATIONS INDICATED BY THE ILLUSTRATION. SrVPOperotions MODULE 9PCS. HYUNDAI HIS-S265RG(265W) Uc#1001133 ClessB BUYER: INVERTER 1 1 9 PCS.1 ENPHASE I 4215-60-21-1-.-S22-I13 ROOF TYPE I CONCRETE TILE DATE: SUB-ARRAY INFORMATION iATY OF MI NIF ARRAY#1 ARRAY#2 ARRAY#3 MOD OTV 9 NA NA BUYER:_ fyt tli KING ND TILT 23° NM NA. AZIMUTH 257- NA' NA' DATE: VA City of Menifee Building Dept APR 2 7 2017 REVIEWED 'approval of these pi,ins Received 16'-S'ARRAY 'pproval Of,any viola 'an of; 17'-3'FLASHING 3' egulations and ordinj noes. ;oysite completim. i t i i i I - I i 1 SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE T _ _ UTILITY METER 8 MAIN SERVICE PANEL —— - (VERIFIED BY BUILDER) � (———_ J L NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF ®� PLAN 1924 ELEVATION B ORIENTATION 4 LO #56 LENNAR: ORIGINAL BY: KIM ABCOUWER BATE:I AIL 9 MARIPOSA OSA' REVIEWED BY:SHAUN MARUNA DATE:16.11.30 AT THE LAKES CO NA,CA I92 DRIVE,#302 CORONA.LA 92879 REV.# BY GATE DESCRIPTION •, �namast6 DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 451tld e,CO8304 30273 BRISTOL GATE LANE Boulder,C W0300 PLOT PLAN I I/16'=I'-0' MENIFEE,CA 303.ddT.0300 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL .ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE,CA INV. MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH(TMAX) ASHRAE-2% °C 37 INV. MODEL INVERTER SPEC M215-60-2LL-S22-IG TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN .°C. .,-, --—2 . INV. MAX POWER.(WAC MAX) INVERTER SPEC. .WATTS(AU 225.,,,. -, TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV.INPUT V,(VoC MAX) INVERTER SPEC V-777-7 48 TEMP,DELTA LOW(TEELTA) THIN-TTEST °C -27 INV. OUTPUT V.(VAc MOM) INVERTER SPEC VOLTS(AG) 240 MOD. MANUFACTURER MODULE SPEC HYUNDAI INV. OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD. PART NUMBER MODULE SPEC HIS-S265RG INV.OUTPUT CURRENT,IAC INVERTER SPEC AMPS(AC) 0.9 MOD. POWER STC(P) MODULE SPEC WATTS(oc) 265 INV.PHASE QUANTITY INVERTER SPEC PHASE I MOD. POWER PTC MODULE SPEC WATTS(DC) 238 COMPLIANCE INVERTER SPEC UL174111EEE1547 FET MOD. OPERATING VOLTAGE NMP) MODULE SPEC VOLTS(oc) 31.30 INV.GROUNDING INVERTER SPEC ISOLATED MOD. OPEN CCT. VOLTAGE(VOG) MODULE SPEC VOLTS(DC) 38.10 INV.OTY,MAX/BRANCH CCT. INV.QTYec GTY 9 MOD. COEFF.VOLT/TEMP(COEF) MODULE SPEC V/°C -0.114 BRANCH CCT. OUTPUT, IMAXBG (IAC•INV.QTYac) AMPS(AC) 8.10 MOD. MAX VOLTAGE(VMAXMOD) (VOC r(To°CoU)) VOLTS(DC) 41.18 INV.QUANTITY,TOTAL INV,QTYT QTY 9 MOD. OPERATING CURRENT(IMP) MODULE SPEC AMPS(DC) 8.50 TOTAL SYSTEM OUTPUT,IMAXTS (IAc•INV.QTYT) AMPS(AC) 8.10 MOD. SHORT CCT. CURRENT(ISO MODULE SPEC AMPS(Do) 9.00 MOD. MAXIMUM CURRENT(IMAX) (ISC' 1.25) AMPS(oc) 11.25 MIN.AMPACITY REQ'D,PER NEC (IMAX• 125) AMPS(oC) 14.06 SERIES FUSE RATING,MAX MODULE SPEC AMPS(DC) 15 ELECTRICAL EQUIPMENT SCHEDULE KEY OTY MANUFACTURER MODEL NOTES TRADE 1 9 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR t 52 co 2 9 ENPHASE M215-60-2LL-S22-IG PVINVERTER SOLAR 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR rDYl51C 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,24OV.30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR, 120V SOLAR set0fa 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR 8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS:I X 15A-IP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBO PV BREAKER,I X 20A-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 I TBD TBD SERVICE PANEL,MIN. 125A BUS BLDR.ELEC. II I TBD TBD UTILITY METER.MIN. 120/24OV.200A BLDR.ELEC. 12 TBO TBD GROUNDING ELECTRODE UFER BLDR.ELEC. 13 1 1 1 TBD I TBO I GROUNDING ELECTRODE.690.47(D) I SOLAR CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS U CONDITION OF USE(COW: (AMPACITV•TEMP. DERATE`FILL DERATE) vs.REO'D(IMAX) ITEM UNIT PANEL 2)TERMINALS(TERM): AMPACITY AT TERMINALS. vs.REO'D,(IMAx• 1.25) PANEL MFR. CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALC' AMPACITY W/O TEMP. FILL RESULT JREQ'DMUSEDCA) BUS RATING AMPS 200 TYPE DERATES DERATE DERATE. (A) MAIN DISCONNECT AMPS 200 A #12 CU THWN-2 COU 30 0.76 1.0 22.00 ALLOWED PV PER NEC AMPS 40 25 PV OCPD DEVICE USED AMPS 20 #10 CU NM-B COU400.91 1.0 36.40 TERM 35 35 C #10 CU NM-B COU 40 0.91 1.0 36.40 TERM 35 35 Mike Dufauft CONDUCTOR SCHEDULE sr VP ope attons KEY CONDUCTORS CU/AL TYPE LOCATION TRADE UD#3003133 Clau B A 1412 ENGAGE CABLE. 14613.FREE AIR CU TC-ER ARRAY SOLAR B 3410, 1410 EGC CU NM-B(ROMEX) INTERIOR SOLAR C 3-#10, 1-#10 EGC CU NM-B(ROMEX) INTERIOR SOLAR D CAT5E.ETHERNET CABLE CU CATSE INTERIOR SOLAR 5 © II E 146GEC,2010 CEC 690.47(D) CU I BARE EXTERIOR SOLAR O e p M - SEE NOTE 15 I 10 0 RA/iP' O O O O G P S N G _J 13 = E A R C = 12 ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.385 KW LOT#56 LENNAR: ORIGINAL BY: KIM ABCOUWER DATE:16.11.29 MARIPOSA REVIEWED By.SHAUN MARUNA DATE:16.11}q AT THE LAKES CORONA, CA 9O'DRIVE,#3az CORONA,CA 92879 REV.# BY DATE DESCRIPTION Qu namasG6a saua DWG TITLE: PAGE#: SCALE:. SITE LOCATION: 4571 Broaderay Street INDIVIDUAL 30273 BRISTOL GATE LANE Boulder,CO 803N PLOT PLAN 2 NTS 303.447.0300 ELECTRICAL MENIFEE,CA �- STRUCTURAL NOTES: Mike Dufaulf SOLAR CONTRACTOR- 5r VP OperafiDns I)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. UGq 3001133 Gd55 B 2)ALL PV ROOF.ATTACHMENTS WIL.BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS.TO MAXI Utl EXTENT.ROSSIBLE. 3)ROOF PENETRATIONS ASSaCIAFED WITH SOLAR RACNING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED, 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL,VERSION 227.3,PUB 140113-ICC,JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH 09 SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(Z-)BEYOND THE EDGE OF THE PV ARRAY 7 SUB-ARRAY. 4DPA 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. ROOFING CONTRACTOR- 1)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3', 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(I')OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE.BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. TObea Ile fedu iv d plans ELECTRICAL NOTES: GENERAL- 1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. L)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703, IEC61646.IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT ii'. 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY: KIM ABCOUWER DATE:16.11. LENNAR: 29 MARIPOSA REVIEWED BY: SHUN MARUA I DATE:16.11-30 AT THE LAKES 980ONA,CA I92 DRIVE,#302 CORONA,CA 92879 REV.# BV DATE I DESCRIPTION •� is namasbe OLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4511 Broadway Street INDIVIDUAL 30273 BRISTOL GATE LANE Boulder,CO 80304 PLOT PLAN 3 NTS MENIFEE,CA NOTES 303.447.0300 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. RENT 1 FFM tor,or n or city bP kept o the SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER 8 MAIN SERVICE PANEL (VERIFIED BY BUILDER) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP I-877-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V Sri pppe elNDns AC OPERATING CURRENT: U A °�3001'33 CI255B NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION LENNAR: ORIGINAL BY: KIM ABCOINJER DATE:16.11.29 MARIPOSA -REVIEWED BY:SHAUN MARINA DATE:16.11.30 AT THE LAKES CO NA.CA I92 DRIVE,#302 CORONA.CA 928]q REV.# BY DATE DESCRIPTION to namaste DWG TITLE: PAGE#: SCALE: SITE LOCATION: - 4571 Bmadway Street INDIVIDUAL 30273 BRISTOL GATE LANE Boulder,W 803M PLOT PLAN 4 NTS MENIFEE.CA PLACARDS 303.447.0300