Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
PMT17-01197
City of Menifee Permit No.: PMT17-01197 29714 HAUN RD. Type: Residential Electrical S-CCEL/�? MENIFEE,CA 92586 MENIFEE Date Issued: 0 5/2 312 01 7 PERMIT Site Address: 30083 SUTTON CT, MENIFEE,CA 92584 Parcel Number: 364-370-043 Construction Cost: $8,331.50 Existing Use: Proposed Use: Description of SOLAR TR 30422-3 CAMELLIA Work: 12 MODULES,3.18KW LOT 144 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA,CA 92879 ATTN GOREEN MUELLER Applicant Phone:9493498269 JEREMIAH ACAYTURRI License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO, CA 92656 Fee Description City Amount tSl Solar,Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 2.00 General Plan Maintenance Fee-Electrical 1 12.60 $294.60 The Issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carded on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Pernit_Template.rpt Page 1 of 1 CFETY •ERM IT/PLAN CH ECK APPLICATION Menifee DATE PERMIT/PLAN CHECK NUMBER l OI !a TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL [-]MULTI-FAMILY ❑MOBILEHOME ❑POOL/SPA ❑SIGN SUBTYPE: ❑✓ ADDITION ❑ALTERATION ❑DEMOLITION ❑ELECTRICAL []MECHANICAL [-]NEW []PLUMBING [:IRE-ROOF-NUMBEROFSQUARES DESCRIPTION OF WORK Solar Permit-Plan 2785-3.18 kW/12 PCS Master Solar Permit No.:PMT14-02629 PROJECT ADDRESS 30083 Sutton Ct,Menifee, CA 92584 ASSESSOR'S PARCEL NUMBER 36C/-370-Dy3 LOT 144 TRACT 30422-3 PROPERTY OWNER'S NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturd@lennar.com APPLICANT NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,suite 302, Corona,CA 92879 PHONE (951)8173680 EMAIL jeremiah.acayturrl@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? ❑✓YES❑NO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturi@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ $8,331.50 S L SQ FT APPLICANT'S SIGNATURE DATE 04/06/2017 DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREENlog SMIP INVOICE •I1, PAIDAMOUNT AMOUNT % �WVV 0CASH 0CHECK# OCREDITCARD VISA/MC PLAN CHECK FEES PAID AMOUNT O CASH O CHECK# O CREDIT CARD VISA/MC OWNER BUILDER VERIFIED OYES O NO DL NUMBER NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM 1 OTY MFR. 1 MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 3.180 KW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 1 12 PCS. HYUNDAI I HIS-S265RG(265W) BUYER: INVERTER- 12PCS. ENPHASE I MZIB-60-2LL-S"2113 -.,-. . ._,. ... ROOF TYPE - TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: SUB-ARRAY INFORMATION ARRAY#I ARRAY#2 1 ARRAY#3 MOD OTY 12 NA NA BUYER: TILT 23° 1 NW NA' DATE: AZIMUTH 1 232° 1 NM I NA' CITY OF MENIF E BUILDING AND 3AFE City of Menifee PLAN APPROV Building Dept APR Z 0 2011 RIMEWEDBY Approvalpans all notReceived apploval of,any violatiol of any regulations and ordinanc s.This I 29'-8'ARRAY jobsite until complction. 30'-6'FLASHING 8'-1' r--- —_ -- e SOLADECK i TRANSITION WIRE N BOX (UNDER ARRAY) j i PV AC DISCONNECT EXTERIOR-GARAGE amoso UTILITY METER e i MAIN SERVICE PANEL (VERIFIED BY BUILDER) �-------- -------- � A r p- NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN 2785 ELEVATION A ®� ORIENTATION 3 LOT#144 LENNAR: ORIGINAL BY: JIM PARKS DATE:16.12.07 CAMELLIA AT REVIEWED BY:KIM ABCOUWER I DATE:16.12.08 980 MONTECITO DRIVE,#302 THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION • a ma sGe DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Bmatlway Street INDIVIDUAL 300B3 Bl7rTON COURT Boulder,C080304 PLOT PLAN 1 1/16-=1'-0- MENIFEE,CA 303.447.0300 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE.CA INV. MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INV. MODEL INVERTER SPEC M215-60-2LL-S22-IG TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN, .PC, -.. __ -2. INV. MAX POWER.(WAD MAX) INVERTER SPEC,.WATT5(Ad 225 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V.(VDC MAX) INVERTER SPEC VOLTS OCT 48 TEMP,DELTA LOW(TDELTA) THIN-TTEST °C -27 INV. OUTPUT V,(Vac NOM) INVERTER SPEC VOLTS(Ad 240 MOD, MANUFACTURER MODULE SPEC HYUNDAI INV. OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD. PART NUMBER MODULE SPEC HIS-S265RG INV. OUTPUT CURRENT,IAC INVERTER SPEC AMPS(AO) 0.9 MOD.POWER STC(P) MODULE SPEC WATTS(Dc) 265 INV. PHASE QUANTITY INVERTER SPEC PHASE I MOD. POWER PTC MODULE SPEC WATTS(DC) 238 COMPLIANCE INVERTER SPEC UL174I/IEEEI547 MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(DU 1 31.30 INV. GROUNDING INVERTER SPEC ISOLATED MOD. OPEN CCT.VOLTAGE(VDc) MODULE SPEC VOLTS(a) 38.10 INV. OTY.MAX /BRANCH CCT. INV.QTYGc QTY 1 12 MOD.COEFF.VOL7/TEMP(COEF) MODULE SPEC V/°C -OA14 BRANCH CCT.OUTPUT, IMAXBC I(IAC-INV.OTYBO) AMPS(AG) I 10.80 MOD. MAX VOLTAGE(VMAXMOO) (VDc+(TD•COEF)) VOLTS(DO 41.18 INV, QUANTITY,TOTAL I INV.GTYT OTY I 12 MOD.OPERATING CURRENT(IMP) MODULE SPEC AMPS(130 8.50 TOTAL SYSTEM OUTPUT,IMAXT3 I(IAC•INV.QTYT) AMPS(AC) 10.80 MOD. SHORT CCT. CURRENT(Isc) MODULE SPEC AMPS(DC) 9.00 MOD.MAXIMUM CURRENT(TMAX) (ISC° 1.25) AMPS(DO 11.25 I'D .�Z MIN.AMPACITY REG'D,PER NEC ([MAX• L25) AMPS(130 14.06 SERIES FUSE RATING,MAX MODULE SPEC AMPS(DC) 15 ELECTRICAL EQUIPMENT SCHEDULE KEY OTY MANUFACTURER MODEL I NOTES TRADE 1 12 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR 2 12 ENPHASE M215-60-2LL-S22-IG PVINVERTER SOLAR 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,240V,30A SOLAR .sired(0 b8 5 1 ENPHASE ENVOY PV DATA MONITOR.120V SOLAR „lu0 Of d1C I 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBO TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR d aPP Dved Ph 8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS:I x 15A-1P(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBD PV BREAKER,I x 20A-ZP,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 1 TO TBD SERVICE N MIN. 125A BUS BLDR.ELEC. II 1 TBD TBD UTILITY MEPATER.EL,IPH,120/24OV,200A BLDR.ELEC. 12 1 1 1 TBD I TBD I GROUNDING ELECTRODE UFER BLDR.ELEC. CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS 1)CONDITION OF USE(COU): I (AMPACITY•TEMP.BERATE•FILL DERATE)W. REO'D(IMAX) ITEM UNIT PANEL 2)TERMINALS(TERM): I AMPACITY AT TERMINALS.Vs. REQ'D,([MAX• 1.25) PANEL MFR. CUTLER-HAMMER KEY SIZE CU/Al INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REQ'0 OCD BUS RATING AMPS 200 TYPE DERATES DEBATE DEBATE (A) (A) USED(A) MAIN DISCONNECT AMPS 1200 A #12 CU THWN-2 COU 30 0.76 1-0 22AO 10.80 ALLOWED PV PER NEC AMPS 1 40 TERM 25 1 25 13.50 20 PV OCPD DEVICE USED AMPS 120 B #10 CU NM-B COU 40 0.91 1.0 1 36.40 10.80 TERM 35 35 13.50 20 C #10 CU NM-B COU 40 0.91 L0 36.40 10.80 TERM 35 1 35 13.50 20 CONDUCTOR SCHEDULE KEY I CONDUCTORS 1 CU/AL TYPE LOCATION TRADE A 1-#12 ENGAGE CABLE, 1-#6G,FREE AIR CU TC-ER ARRAY I SOLAR B 3-#10.I-#IO EGC CU NM-B(ROMEX) INTERIOR SOLAR C 3-#10.I-#10 EGC I CU I NM-B(ROMEX) I INTERIOR SOLAR p I CAT5E,ETHERNET CABLE I CU I CATSE I INTERIOR I SOLAR 5 6 7 � o M — SEE NOTE IS 10 © O ISNIP 9 0 Q O :oO 3rT IN G G- I A 8 1 C = I2 1 ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 3.180 KW LOT#144 : ORIGINAL BY: JIM PARKS '980 MONTECITO DRIVE,#302 DATE:Ifi.12.07 CAMELLIA AT LENNAR REVIEWED BY:KIM ABCOUWER DATE:J612,08 ' " THE LAKES CORONA.CA 92879 REV.# BY DATE DESCRIPTION namaste SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 30083 SUTTON COURT B..Ider,CO BD304 PLOT PLAN 2 NTS MENIFEE,CA 303.447.0300 ELECTRICAL STRUCTURAL NOTES: SOLAR CONTRACTOR- U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. .. 2)ALL.P.V.ROOF..ATTAGHMEN)S WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO.MAXIMUM FXTENT,POSSIBLE__ .. - 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLAOECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED, 5)PV ARRAY WILL BE A MINIMUM OF 3-ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL.VERSION 227.3.PUB 140113-ICC,JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(I-)SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. ROOFING CONTRACTOR- U DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3% 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION.IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT 01 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO).N BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. —4 !� •:mtit -al,st ite"city oust I c kept On ELECTRICAL NOTES: GENERAL- 1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR.EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90°C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703, IEC61646, IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. II)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS. WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122, 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT t. 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE:OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. CAMELT LENNAR: ORIGINAL BY: JIM PARKS DATE:16-12.07 LJ A,A 980 MONTECITD DRIVE,#302 REVIEWED BY:,Kl"AB000WER I DATE:16.12.08 THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION u namaste .et.. DWG TITLE: P7# SCALE: SITE LOCATION: 457d BroadwaySlreet INDIVIDUAL 30083 SUTTON COURT Boulder,GO 80304PLOT PLAN TS MENIFEE,CA 303.447.0300 NOTES CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. E� SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER B MAIN SERVICE PANEL (VERIFIED BY BUILDER) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: 10.8 A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION LENNAR: ORIGINAL BY: JIM PARKS DRIVE,#302 DATE:16.12.07 980 MONTECITO CAMELLIA AT - - REVIEWED BY:KIM ABCOUWER I DATE:16.12.08 THE LAKES CORONA.CA 92879 REV.# BY DATE DESCRIPTION •� namaste SOtnp DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Bmadmy S6eel INDIVIDUAL 30083 SUTTON COURT Boulder,CO 110304 PLOT PLAN 4 NTS MENIFEE,CA 303.447.0300 PLACARDS