PMT17-01194 City of Menifee Permit No.: PMT17-01194
29714 HAUN RD.
'ACCELA MENIFEE,CA 92586 Type: Residential Electrical
MENIFEE Date Issued: 0 5/2 312 01 7
PERMIT
Site Address: 30119 SUTTON CT, MENIFEE,CA 92584 Parcel Number: 364-370-040
Construction Cost: $6,943.00
Existing Use: Proposed Use:
Description of SOLAR TR 30422-3 CAMELLIA
Work: 10 MODULES,2.65KW
LOT 141
Owner Contractor
LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC
980 MONTECITO DR#302 25 ENTERPRISE
CORONA,CA92879 ATTN GOREEN MUELLER
Applicant Phone:9493498269
JEREMIAH ACAYTURRI License Number:728102
LENNAR HOMES OF CALIFORNIA INC
25 ENTERPRISE
ATTN GOREEN MUELLER
ALISO VIEJO,CA 92656
Fee Description City Amount(S)
Solar,Residential or Small Commercial 1 252.00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 1.00
General Plan Maintenance Fee-Electrical 1 12.60
$293.60
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bldg_Pennit_Template.rpt Page 1 of 1
• IT/PLANAPPLICATION
'Menifee
DATE PERMIT/PLAN CHECK NUMBER I"1 0114It
TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILEHOME POOL/SPA ❑SIGN
SUBTYPE: ❑✓ ADDITION ❑ALTERATION []DEMOLITION ❑ELECTRICAL [-]MECHANICAL
❑NEW []PLUMBING ❑RE-ROOF-NUMBER OF SQUARES
DESCRIPTION OF WORK Solar Permit-Plan 2077-2.65 kW/10 PCS
Master Solar Permit No.:PMT14-02629
PROJECTADDRESS 30119 Sutton Ct,Menifee,
CA 92584
ASSESSOR'S PARCEL NUMBER %t/ -3/0- Oqt / LOT 141 TRACT 30422-3
PROPERTY OWNER'S NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr.,suite 302,Corona,CA 92879
PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com
APPLICANT'NAME Lennar Homes of California,Inc.
ADDRESS L 980 Montecito.Dr.,suite 302,Corona, CA 92879
PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com
CONTRACTOR'S NAME Lennar Homes of California,Inc. OWNER BUILDER? ❑✓ YESQNO
BUSINESS NAME Lennar Homes of California, Inc.
ADDRESS- 980 Montecito Dr.,Suite 302,Corona, CA 92879
PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com
CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B
VALUATION$ $6,943.00 SO FT L SQ FT
APPLICANT'S SIGNATURE DATE 04/06/2017
- r
CITY STAFF USE O1VLY
DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER
BUILDING PLANNING ENGINEERING FIRE GREEN SMIP {J"
INVOICE A�� �
• PAIDAMOUNT
AMOUNT (/1 O CASH O CHECK# O CREDITCARD VISA/MC
PLAN CHECK FEES PAIDAMOUNT OCASH OCHECK# OCREDITCARD VISA/MC
OWNER BUILDER VERIFIED O YES O NO DL NUMBER NOTARIZED LETTER 0 YES O NO
City of Menifee Building&Safety Department 29714 Houn Rd. Menifee, CA 92586 951-672-6777
www.cityofinenifee.us Inspection Request Line 951-246-6213
SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED
ITEM 1 OTY MFR. 1 MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE
SYSTEM SIZE 2.650 KW LOCATIONS INDICATED BY THE ILLUSTRATION.
MODULE 1 IO PCS. HYUNDAI I HIS-S265RG(265W) BUYER: —
1 INVERTER .. IO PCS. ENPHASE I M215-60-2LL_S22-IG.
ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE:
SUB-ARRAY INFORMATION
ARRAY#1 ARRAY#2 ARRAY#3
MOD OTY 10 NA
23° NA° NA NA. BUYER: f'ITV OF LIEN E
TILT
AZIMUTH 23c NM NA" DATE:___ �I/;z�$�pI6 AN SAFI
PLAN APPROV
City of Menifee
Building Deft REVIEWEDBY
tO
APR 2 0 2011
Approval of diet a plans hall nol
approval of,any violatio I of any
Re e i v e regulations and ordina .This
�J V jobsite until completion,
I6'-5'ARRAY
20'-4' I7'-3'FLASHING
— — ———— ——————————————
f
I
i
I
i
j SO WIRE
TRANSITIANSITI ON BOX
I � (UNDER ARRAY)
emmoo
\�I
PV AC DISCONNECT
EXTERIOR-GARAGE
UTILITY METER 8
MAIN SERVICE PANEL
-f (VERIFIED BY BUILDER)
NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF
PLAN TATI ELEVATION A REVERSE N
ORIENTATION 3 LOT# 141 �V
LENNAR: ORIGINAL BY: JIM PARKS DATE:16.12.07
CAMELLIA AT REVIEWED BY:KIM ABCOUWER DATE:16.12.08
980 MONTECITO DRIVE,#302
THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION •,
namastd
some
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street
INDIVIDUAL 30119 SUTTON COURT Boulder,CO M304
PLOT PLAN 1/16'=1'-0' MENIFEE,CA 303A47.0300
SYSTEM LAYOUT
MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS
ITEM NOTE/CALC UNIT DETAIL ITEM .NOTE/CALC UNIT DETAIL
LOCATION MENIFEE,CA INV. MAKE INVERTER SPEC ENPHASE
TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INV.MODEL INVERTER SPEC M215-60-2LL-S22-1G
TEMP,AMBIENT LOW(THIN) ASHRAE EXTR qIN.. °C -2 INV.MAX POWER.(WAC MAX) INVERTER SPEC W TTS(Ac) 225
TEMP,MODULE TEST(TTEsT) MODULE SPEC °C 25 INV. INPUT V.(Voc MAX) INVERTER SPEC' PO TS(O[) 48
TEMP,DELTA LOW(TOELTA) THIN-TTEST °C -27 INV. OUTPUT V.(VAc NOM) INVERTER SPEC VOLTS(AC) 240
MOD.MANUFACTURER MODULE SPEC HYUNDAI INV. OUTPUT FREQUENCY INVERTER SPEC HERTZ 60
MOD.PART NUMBER MODULE SPEC HIS-S265RG INV. OUTPUT CURRENT.IA[ INVERTER SPEC AMPS(AC) 0.9
MOD.POWER STC(P) MODULE SPEC WATTS(DC) 265 INV.PHASE QUANTITY INVERTER SPEC PHASE 1
MOD.POWER PTC MODULE SPEC WATTS(oc) 238 COMPLIANCE INVERTER SPEC UL1741/IEEE1547
MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(oc) 31.30 INV.GROUNDING INVERTER SPEC ISOLATED Y DE
MOD.OPEN CCT.VOLTAGE(YOG) MODULE SPEC VOLTS Inc) 38.10 INV.OTY,MAX/BRANCH CCT. INV.OTYec OTY 10
MOD.COEFF.VOLT/TEMP(COEF) MODULE SPEC V/°C -0.114 BRANCH CCT.OUTPUT,IMAXRC (IAc°INV.QTY8c) AMPS(AO) 9.00
MOD.MAX VOLTAGE(VMAXM00) (VOc+(TD•COEF)) VOLTS(aU 41.18 INV.QUANTITY,TOTAL INV.GTYT QTY t0
MOD.OPERATING CURRENT(IMP) MODULE SPEC AMPS(DO 8.50 TOTAL SYSTEM OUTPUT, IMAXIS (IAC•INV.OTYT) AMPS(AC) 9.00
MOD.SHORT CCT.CURRENT(Isc) MODULE SPEC AMPS Inc) 9.00
MOD.MAXIMUM CURRENT([MAX) (Isc• 1.25) AMPS 00 11.25
MIN.AMPACITY REO'D,PER NEC (IMAX• 1.25) AMPS(Oc) 14.06
SERIES FUSE RATING,MAX MODULE SPEC AMPS(CC) 15
ELECTRICAL EQUIPMENT SCHEDULE constiu
KEY QTY MANUFACTURER MODEL NOTES TRADE YIf100�
1 10 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR (�
2 10 ENPHASE 1215-60-21LL-S22-I13 PVINVERTER SOLAR
3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR
4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT.NEMA 3R.240V.30A SOLAR
5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR
6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR
7 1 TBD TBO CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR
8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS;I X I5A-IP(ENVOY) SOLAR
9 NOTE CUTLER-HAMMER TBO PV BREAKER, I x 20A-2P.LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR
10 I TBD TBD SERVICE PANEL,MIN. 125A BUS BLDR.ELEC.
11 I TBD TBD UTILITY METER,]PH. 120/24OV,200A BLDR.ELEC.
12 1 I 1 TBD I TBO I GROUNDING ELECTRODE LIFER BLDR.ELEC.
CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS
1)CONDITION OF USE(COU): I (AMPACITY•TEMP.DERATE• FILL DEBATE)Vs.REQ'D(IMAX) ITEM UNIT PANEL
2)TERMINALS(TERM): I AMPACITY AT TERMINALS.vs.REO'D.(IMAX• 125) PANEL MFR. CUTLER-HAMMER
KEY SIZE CU/AL INSULATION CALC' AMPACITY W/O TEMP. FILL RESULT REO'D OCD BUS RATING AMPS 200
TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200
A #12 CU THWN-2 COU 30 0.76 1.0 22.80 9.00 ALLOWED PV PER NEC AMPS 40
TERM 25 25 11.25 20 PV OCPD DEVICE USED AMPS 20
B #to CU NM-B COU 40 0.91 1.0 36.40 9.00
TERM 35 35 11.25 20
C #10 CU NM-B COU 40 0.91 1.0 36.40 9.00
TERM 35 35 11.25 1 20
CONDUCTOR SCHEDULE
KEY CONDUCTORS CU/AL TYPE LOCATION TRADE
A I-#12 ENGAGE CABLE, 1-#6G.FREE AIR CU TC-ER ARRAY SOLAR
B 3-#10, I-#10 EGG I CU I NM-B(ROMEX) INTERIOR SOLAR
C 3-#10.1410 EGC I CU I NM-B(ROMEX) INTERIOR SOLAR
D I CATSE.ETHERNET CABLE I CU I CAT5E INTERIOR SOLAR
5 6 11
7 • c • O
SEE NOTE 15 10
ISA/1P
9
O 0 3M11F
1N
A B C
ROOF EXTERIOR-GARAGE 1
ELECTRICAL DIAGRAM 2.650 KW
LOT# 141
: ORIGINAL BY: JIM PARKS DATE:16.12.07
LENNAR
CAMELLIA AT . REVIEWED BY:KIM ABCOUWER I DATE:16.12.08
- 980 MONTECITO DRIVE,#302
THE LAKES CORONA, Q CA 92879 REV.# BY DATE DESCRIPTION
bnamaste
SOLAR
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street
INDIVIDUAL 30119 SUTTON COURT Boulder,CO 80304
PLOT PLAN 2 NTS MENIFEE.CA 303.447.0300
ELECTRICAL
STRUCTURAL NOTES:
SOLAR CONTRACTOR-
U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C.
_2)ALI PV,ROGF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOFiFNAMING MEMBERS,10.MAXIM_U_M_EXTE_N_T_POSSIBLE.
" 3)ROOFPENE'TRATIONB ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. - - -
4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED.
5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE.
6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION
MANUAL.VERSION 227.3,PUB 140113-ICC,JANUARY 2014.
7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(I-)SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND THE EDGE
OF THE PV ARRAY/SUB-ARRAY. ZTMI 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. i
ROOFING CONTRACTOR-
U DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'.
2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE 1
APROVED PRIOR TO PV SYSTEM INSTALLATION.
3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(I')OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO
BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS.
4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE.
5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS.
6)SIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE.BIROSTOP TO BE SPECIFIED BY ROOFER PRIOR TO the ape
INSTALLATION.
he f'OdC11
1 plum In
ELECTRICAL NOTES:
GENERAL-
I)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL),
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC.
3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC
WELD.
4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING.NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE
MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED.
5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE.
6)ALL CONDUCTORS WILL HAVE A 90°C RATING TO ENSURE CODE COMPLIANCE.
SOLAR CONTRACTOR-
7)MODULE CERTIFICATIONS WILL INCLUDE U1_1703, IEC61646,IEC61730.
8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS.
9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS.
10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM.
IU MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE
ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER.
12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122.
13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS.
14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT.
15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR.
SIGNAGE-
16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES.
17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS.
18)MARKING /PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT k.
19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY I0'..
BUILDER ELECTRICAL AND SOLAR CONTRACTORS-
20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER.
21).SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26.
ORIGINAL BY: JIM PARKS DATE:16J2.07
LENNAR:
CAMELLIA AT REVIEWED BY:KIM ASCOUWER DATE:16.12.08
980 MONTECITO DRIVE.#302
THE LAKES CORONA,CA 92979 REV.# BY DATE DESCRIPTION
namaMAI
seq
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Bmadmy Sueet
INDIVIDUAL 30119 SUTTON COURT Boulder,CO BD304
PLOT PLAN 3 NTS MENIFEE,CA 303A47.0300
NOTES
CAUTION:
POWER TO THIS BUILDING IS SUPPLIED BY THE
UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS
ARE LOCATED AS SHOWN.
or,or an
to or city
e kept on the
SOLADECK WIRE
TRANSITION BOX
(UNDER ARRAY)
PV AC DISCONNECT
EXTERIOR-GARAGE
UTILITY METER 8.
MAIN SERVICE PANEL
(VERIFIED BY BUILDER)
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
1-877-SLR-POWR
PV POWER SOURCE - AC SPECS
AC OPERATING VOLTAGE: 240 V
AC OPERATING CURRENT: 9.0 A
NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION
LENNAR: ORIGINAL BY: JIM PARKS DATE:16.12.07
REVIEWED BY:KIM ABCOUWER I DATE:16.12.00
CAMELLIA AT
960 MONTECITD DRIVE,#302
CORONA,CA 92879 REV.# BY DATE DESCRIPTION
THE LAKES Gbnama oGe
DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 4571 Smadway Street
INDIVIDUAL 30119 SUTTON COURT Boulder,CO W304
PLOT PLAN A NTS MENIFEE.CA 303.447.0300
PLACARDS