Loading...
PMT17-01192 City of Menifee Permit No.: PMT17-01192 29714 HAUN RD. Type: Residential Electrical <A—CCELA-? MENIFEE, CA 92586 '"'"""t'.A- MENIFEE Date Issued: 05/23/2017 PERMIT Site Address: 30232 SUTTON CT,MENIFEE,CA 92584 Parcel Number: 364-370-055 Construction Cost: $6,943.00 Existing Use: Proposed Use: Description of SOLAR TR 30422-3 CAMELLIA Work: 10 MODULES,2.65KW LOT 156 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA, CA 92879 ATTN GOREEN MUELLER Applicant Phone:9493498269 JEREMIAH ACAYTURRI License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO, CA 92656 Fee Description Of( Amount(Sl Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carded on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_aldg_Permit_Template.rpt Page 1 of 1 BUILDING & SAFETY PERMIT/PLAN CHECK,APPLICATION Menifee DATE PERMIT/PLAN CHECK NUMBER I'1 O A TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL [—]MULTI-FAMILY ❑MOBILEHOME ❑POOL/SPA ❑SIGN SUBTYPE: ❑✓ ADDITION []ALTERATION ❑DEMOLITION []ELECTRICAL [-]MECHANICAL ❑NEW ❑PLUMBING El RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit-Plan 2077-2.65 kW/10 PCS Master Solar Permit No.:PMT14-02629 PROJECTADDRESS 30232 Sutton Ct,Menifee, CA 92584 ASSESSOR'S PARCEL NUMBER 3 y— 970 -L.J,e� LOT 156 TRACT 30422-3 PROPERTY OWNER'S NAME Lennar Homes of California,Inc. ADDRESS 980 Montecito Dr.,suite 302, Corona, CA 92879 PHONE (951)817-3680 EMAIL leremiah.acayturri@lennar.com APPLICANT NAME Lennar Homes of California,Inc. ADDRESS 980 Montecito Dr.,suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturd@lennar.com CONTRACTOR'S NAME Lennar Homes of California,Inc. OWNER BUILDER? ❑✓YES❑NO BUSINESSNAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Carona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ $6,943.00 SQ L SQ FT APPLICANT'S SIGNATURE DATE 04/06/2017 DEPARTMENT DISTRIBUTION 410 CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN SMIP INVOICE /gyp .� PAIDAMOUNT AMOUNT QC 1 OCASH 0 CHECK# OCREDITCARD VISA/MC PLAN CHECK FEES PAIDAMOUNT OCASH 0 CHECK A OCREDITCARD VISA/MC OWNER BUILDER VERIFIED OYES O NO DLNUMBER NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Department 29714 Noun Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 2.650 KW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 1 10 PCS.1 HYUNDAI HIS-S265RG(265W) BUYER: , ,INVERTER. ._I ...10 PCS. ENPHASE I M215-60-21-L_S2 -1 _-.- ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY.- DATE: SUB-ARRAY INFORMATION ARRAY#1 ARRAY#2 1 ARRAY#3 MOD OTY 10 NA NA BUYER: TILT 23° 1 NA' I MA. CITY OF EM AZIMUTH 270° NA' NA' DATE: AN CRY of Menifee PLAN AP R Building Dept REVIEWED APR 2 0 2017 Approval ofth seplar RReceived e c e I v S d approval l of,a viola) LV•] regulations anc ordina jobsite until w npictio r------------------- ----� I I I I I t I I I I I 19-9 ARRAY SOLADECK WIRE TRANSITION BOX I 13'-2' 20'-7'FLASHING (UNDER ARRAY) I i PV A[DISCONNECT � EXTERIOR-GARAGE SEEM& I UTILITY METER MAIN SERVICE PANEL L r_L L___ —J (VERIFIED BY BUILDER) _ _ 9 r NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF Z PLAN 2077 ELEVATION B-R ORIENTATION I LO ORIGINAL BY: KIM ABCOUWER I DAT CAMELLIA AT ENNAR: E:17.01.05 980 MONTECITO DRIVE.#302 REVIEWED BY:SHAUN MARUNA DATE:17.01.06 THE LAKES CORONA.CA 92879 REV.# BY DATE DESCRIPTION namasG" SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 30232 SUTTON COURT emtdeA GO 80304 PLOT PLAN 1 I/16'=1'-0' MENIFEE,CA 303.447.0300 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE /CALC UNIT DETAIL ITEM NOTE/CALC I UNIT DETAIL LOCATION MENIFEE,CA INV. MAKE INVERTER SPEC ENPHASE TEMP.AMBIENT HIGH(THAX) ASHRAE 2%. °C 37 INV. MODEL INVERTER SPEC M215-60-21-L-S22-IG TEMP,AMBIENT,LOW(THIN). ASHRAE EXTR. IN-. PC -2 INV. MAX POWER,(WAC,MAX) INVERTER SPEC WATTS(Act 225 TEMP.MODULE TEST(TTEST) MODULE SPEC oc 25 INV.INPUT V.(VDC MAX) INVERTER SPEC VOLTS(oa) 48 TEMP,DELTA LOW(TOELTA) THIN-TTEST °C -27 INV.OUTPUT V.(VAC NOM) INVERTER SPEC VOLTS(AC) 240 MOD.MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD.PART NUMBER MODULE SPEC HIS-S265RG INV.OUTPUT CURRENT,IAC INVERTER SPEC AMPS(AO 0.9 MOD.POWER STC(P) MODULE SPEC WATTS(DO 265 INV.PHASE QUANTITY INVERTER SPEC PHASE 1 MOD.POWER PTC MODULE SPEC WATTS(DC) 238 COMPLIANCE INVERTER SPEC Ul_1741AEEEjYJW MOD. OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(oc) 1 31.30 INV.GROUNDING INVERTER SPEC ISOLATED MOD. OPEN CCT.VOLTAGE(Vac) MODULE SPEC VOLTS(oc) 38.10 INV.OTY.MAX 7 BRANCH CCT. INV.QTYBC OTY 10 FET ir DEI MOD.COEFF.VOLT/TEMP(COEF) MODULE SPEC V/-C -0.114 BRANCH CCT.OUTPUT.IMAXBC 1 (IAC'INV.QTYBC) AMPS(Ad 9.00 MOD. MAX VOLTAGE(VMAXM00) (Voc*(To`COEF)) VOLTS(oc) 41.18 INV.QUANTITY.TOTAL I INV.QTYT OTY 10 MOD. OPERATING CURRENT(IMP) MODULE SPEC AMPS(Oc) 8.50 TOTAL SYSTEM OUTPUT,IMAXTS I (IAC`INV.OTYT) AMPS(AC) 1 9.00 MOD. SHORT CCT. CURRENT(Isc) MODULE SPEC AMPS(De) 9.00 MOD. MAXIMUM CURRENT(IMAX) (Ise• 1.25) AMPS(nc) 11.25 _._ MIN.AMPACITY REO'D.PER NEC (IMAX` L25) AMPS(oc) 14.06 SERIES FUSE RATING,MAX MODULE SPEC AMPS(oc) 15 ELECTRICAL EQUIPMENT SCHEDULE 11 not be Onsim KEY OTY WIND ACTURER MODEL NOTES TRADE 1 10 I HIS-S265RG(265W) PV MODULE SOLAR 1:nY RTD Is10nf0 2 10 SE M215-60-2LL-S22-IG PVINVERTER SOLAR Ih13 se( faIp10, 3 1 SOLADECK 0786-3R5 PV ROOF JUNCTION BOX.NEMA 3R SOLAR 4 1 -HAMMER DGZ21URB PV AC DISCONNECT.NEMA 3R,24OV,30A SOLAR 5 1 SE ENVOY PV DATA MONITOR,120V SOLAR 6 1 TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR 8 NOTE -HAMMER TBD PV BRANCH CIRCUIT BREAKERS:I X 15A-IP(ENVOY) SOLAR 9 NOTE R-HAMMER TBD PV BREAKER, I x 20A-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 I TBD SERVICE PANEL,MIN. 125A BUS BLDR.ELEC. 11 1 TBD UTILITY METER, IPH, 120/240V,200A BLDR.ELEC. 12 1 TBD GROUNDING ELECTRODE UFER BLDR.ELEC. CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS D CONDITION OF USE(COU): I (AMPACITY`TEMP.DERATE °FILL DEBATE) w.REQ'D(IMAX) ITEM UNIT PANEL 2)TERMINALS(TERM I AMPACITY AT TERMINALS. VS. REQ'D,(IMAX• 1.25) PANEL MFR. CUTLER-HAMMER KEY 512E CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REQ'D OCD BUS RATING AMPS 200 TYPE DERATES DEBATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 A #12 CU THWN-2 I COU 1 30 0,76 1.0 22.80 9.00 ALLOWED PV PER NEC AMPS 40 TERM 25 25 11.25 20 PV OCPD DEVICE USED AMPS 1 20 B #10 CU NM-B 1 COT 40 0.91 1.0 36.40 9.00 TERM 35 35 11.25 20 C #10 CU NM-B I COU 40 0.91 1.0 36.40 9.00 TERM 35 35 11.25 20 CONDUCTOR SCHEDULE KEY CONDUCTORS CU/AL TYPE LOCATION TRADE A I-#12 ENGAGE CABLE,146G,FREE AIR I CLI I TC-ER JARRAY SOLAR B 3-#10, 1-#10 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR C 3-#10. 1410 EGC I Cu I NM-B(ROMEX) I INTERIOR I SOLAR 5 6 II D I CAT5E,ETHERNET CABLE I CU I CATSE I INTERIOR I SOLAR ® O M SEE NOTE 15 10 O ISAMP 9 O O 2OA/2P O N G G G� A B I C — 12 I ROOF I EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.650 KW LOT# 156 LENNAR: ORIGINAL BY: KIM ABCOUWER DATE:17.01.0 "' 5 CAMELLIA AT REVIEWED BY:SHAUN MARUNA DATE:17.01.06 - 980 MONTECITO DRIVE,#302 THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION Q�mmaste AR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Bm d"y Steel INDIVIDUAL 30232 SUTTON COURT Boulder,CO 80304 PLOT PLAN 2 NTS MENIFEE,CA 303b47.0300 ELECTRICAL STRUCTURAL NOTES: SOLAR CONTRACTOR- U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2).ALL PV.ROOF-ATTACHMENTS.WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS..TO,MAYIMUM EX_TFNT POSSIBLE. 3} OFPE RONETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPAOVCD SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3-ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL,VERSION 227.3.PUB 140113-ICC,JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(F)SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. ROOFING CONTRACTOR- U MEN7 Q DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3-. 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(I')OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. S)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE.BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR.TO INSTALLATION. he penDit VI f r(W Itl emust 6l ELECTRICAL NOTES: GENERAL- 1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC7CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT t. 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT ANO WORKMAN-LIKE MANNER. 20 SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY: KIM ABCOUWER I DATE:17.01.05 CAMELLIA AT LENNAR: REVIEWED BY. SHAUN MARUNA I DATE:17.01.06 980 MONTECITO DRIVE,#302 THE LAKES CORONA.CA 92879 REV.# BY DATE DESCRIPTION Z2namast;6 SOLAR DWG TITLE:. PAGE#: I SCALE: SITE LOCATION: 4571 Broeduray Street INDIVIDUAL 30232 SUTTON COURT Boulder,CO SM04 PLOT PLAN 3 NTS MENIFEE,CA 303.447.0300 NOTES CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. I1 ppA E tl j Illy SOLADECK WIRE 'I m;IIIc TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER 8 MAIN SERVICE PANEL (VERIFIED BY BUILDER) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: 9.o A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION LENNAR:, ORIGINAL BY: KIM ABCOUWER DATE:1].01.05 CAMELLIA AT 9B0 MONTECITO DRIVE.#302 REVIEWED BY:SHAUN MARUNA DATE:17.01.06 THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION to namast6 DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Bme0way Street INDIVIDUAL 30232 SUTTON COURT Boulder,CO 803D4 PLOT PLAN 4 NTS MENIFEE,CA 303.447.0300 PLACARDS