PMT17-01191 City of Menifee Permit No.: PMT17-01191 29714 HAUN RD. <kCCIEL/� MENIFEE,CA 92586 Type: Residential Electrical MENIFEE Date Issued: 05/23/2017 PERMIT Site Address: 30220 SUTTON CT,MENIFEE, CA 92584 Parcel Number: 364-370-054 Construction Cost: $8,331.60 Existing Use: Proposed Use: Description of SOLAR TR 30422-3 CAMELLIA Work: 12 MODULES,3.18KW LOT 155 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA,CA 92879 ATTN GOREEN MUELLER Applicant Phone: 9493498269 JEREMIAH ACAYTURRI License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO,CA 92656 Fee Description OOtt( Amount(8) Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 2.00 General Plan Maintenance Fee-Electrical 1 12.60 $294.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Template.rpt Page 1 of 1 C • . . • APPLICATION Menifee DATE PERMIT/PLAN CHECK NUMBER Q Iq I TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILEHOME EIPOOLISPA ❑SIGN SUBTYPE: ❑✓ ADDITION []ALTERATION ❑DEMOLITION ❑ELECTRICAL [—]MECHANICAL []NEW []PLUMBING El RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permtt-Plan 2785-3.18 RW/12 PCS Master Solar Permit No.:PMT14-02629 PROJECTADDRESS 30220 Sutton Ct,Menifee,CA 92584 ASSESSOR'S PARCEL NUMBER —�?7D —(:)S 1 LOT 155 TRACT 30422-3 PROPERTY OWNER'S NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL leremiah.acayturri@lennar.com APPLICANT-NAME "Lennarflomes of California, Inc. ADDRESS 980 Montecito Dr.,suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL leremiah.acayturri@lennar.com CONTRACTOR'S NAME Lennar Homes of California,Inc. OWNER BUILDER? ❑✓ YES❑NO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Carona,CA 92879 PHONE (951)817-3680 EMAIL leremiah.acayturri@lennar.com CONTRACTOR'S STATE'LICNUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ $8,331.:60 L SQ FT APPLICANT'S SIGNATURE DATE 04/06/2017 CITYSTAFF USE ONLY DEPARTMENT DISTRIBUTION CITYOFMENIFEEBU5INESSLICENSENUMBER too BUILDING PLANNING ENGINEERING FIRE GREEN SMIP INVOICE PAIDAMOUNT OCASH OCHECK# OCREDITCARD VISA/MC a- AMOUNT `-1 W PLAN CHECK FEES PAID AMOUNT O CASH O CHECK k O CREDIT CARD VISA/MC OWNER BUILDER VERIFIED OYES O NO DL NUMBER NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY 1 MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 13.180 KW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 12 PCS-1 HYUNDAI HIS-SZ65RG(265W) BUYER: —_ INVERTER I 12PCS.1 ENPHASE I M215-60-2LL-S22-IG ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: - SUB-ARRAY INFORMATION ARRAY#1 ARRAY#Z ARRAY#3 MOD OTY 8 4 NA BUYER: TILT 23° 23° NA* AZIMUTH 90° 270° NA- GATE:_ f TT'Y OF ENI] City of Menifee RUILDIN AN[ Building Dept PLAN APP lovi APR 2 0 2017 REVIEWEDEY G Approval or thes plans a Received approval of,any 'olatim regulations and Or ljr,, jobsi(e until Comp 27'--2' 2 FLASHING 10' FLASHING I I SOLADECK WIRE ) TRANSITION BOX I J (UNDER ARRAY) i . PV AC DISCONNECT - EXTERIOR-GARAGE i �y `Vr UTILITY METER MAIN SERVICE PANEL � (VERIFIED BY BUILDER) 6'-T ARRAY 7'-5'FLASHING 76-3' ' r_ NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF Z PLAN 2785 ELEVATION A-L 01 NAION2 LO #I CAMELLIA-AT- LENNAR; ORIGINAL BY: KIM ABCOUWER I DATE:17.01.05 980 MONTECITO DRIVE,#302 REVIEWED'aY.SHAUN MARUNA I DATE:17.01.06 THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION la namastrl$ DWG TITLE: PAGE#: SCALE: SITE LOCATION: 451rt Broadway Street INDIVIDUAL 30220 SUTTON COURT Boulder,CO 80304 PLOT PLAN 1 1/16'=1'-0' MENIFEE,CA 303."7.0300 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE,CA INV.MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INV.MODEL INVERTER SPEC M215-60-2LL-S22-IG y TEMP,.AMBIENT LOW(THIN) ASHRAE EXTR.MIN 9F . . . _..-2. . .. ,. INV.MAX POWER.(W4c MAX) INVERTER SPEC WATTS(AC) 225 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V,(VDC MAX) INVERTER SPEC VOLTS Inc) 48 TEMP,DELTA LOW(TOELTA) THIN-TTEST °C -27 INV.OUTPUT V, (VAC NOM) INVERTER SPEC VOLTS Ad 240 MOD.MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD.PART NUMBER MODULE SPEC HIS-S265RG INV.OUTPUT CURRENT,AC INVERTER SPEC AMPS(AC) 0.9 MOD.POWER STC(P) MODULE SPEC WATTS(Oc) 265 INV.PHASE QUANTITY INVERTER SPEC PHASE I MOD.POWER PTC MODULE SPEC WATTS(oc) 238 COMPLIANCE INVERTER SPEC UL1741/IEEEI547 MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(oc) 31.30 INV.GROUNDING INVERTER SPEC ISOLATED MOD. OPEN CCT.VOLTAGE(Vac) MODULE SPEC VOLTS(DO 38.10 INV.OTY,MAX/BRANCH CCT. 1 INV.QTnC 1 OTY 12 MOD-COEFF.VOLT/TEMP(COEF) MODULE SPEC V/°C -0.114 BRANCH CCT-OUTPUT, IMAXec I (IAC'INV.GTYBC) I AMPS(AO rYDI MOD.MAX VOLTAGE(VMAXMOD) (Voc♦(TD-COEF)) VOLTS 00 41.18 INV.QUANTITY,TOTAL I INV.QTYT I OTY 12 MOD. OPERATING CURRENT(IMP) MODULE SPEC AMPS(DC) 8.50 TOTAL SYSTEM OUTPUT.MARTS (IAC'INV.QTYT) I AMPS(AQ 10.80 MOD.SHORT CCT.CURRENT(ISO MODULE SPEC AMPS(DC) 9.00 MOD. MAXIMUM CURRENT([MAX) (ISC- 1.25) AMPS(Oc) 11.25 MIN.AMPACITY REO'D,PER NEC (TMAX' 1.25) AMPS(DO 14.06 SERIES FUSE RATING,MAX MODULE SPEC AMPS(oc) 15 ELECTRICAL EQUIPMENT SCHEDULE KEY QTY MANUFACTURER MODEL NOTES TRADE 1 12 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR not bc c003tM 2 12 ENPHASE M215-60-2LL-S22-IG PV INVERTER SOLAR :ny PP ivisions 3 2 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR nIS Sol DfapM 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,24OV,30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR, 120V SOLAR 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR 8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS; I x 15A-IP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBD PV BREAKER.I x 20A-2P.LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 TBD TBD SERVICE PANEL,MIN. 125A BUS BLDR.ELEC. II TBD TBD UTILITY METER,IPH,120/240V,200A BLDR.ELEC. 12 11 1 TBD I TBD I GROUNDING ELECTRODE UFER I BLDR.ELEC. CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS U CONDITION OF USE(COU): I (AMPACITY-TEMP.DERATE • FILL DERATE) vs.REQ'D OMAX) ITEM UNIT PANEL 2)TERMINALS(TERM): I AMPACITY AT TERMINALS. VS.REO'D.(IMAX' 1.25) PANEL HER. CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REO'D OCD BUS RATING AMPS 200 TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 A #12 CU THWN-2 COU 30 0.76 1:0 22.80 10.80 ALLOWED PV PER NEC AMPS 40 TERM 25 25 13.50 20 PV OCPD DEVICE USED AMPS 20 B #10 CU NM-B COU 40 0.91 1-o 36.40 10.80 TERM 35 35 13.50 20 C "0 CU NM-B COU 40 0.91 1 1.0 1 36.40 10.80 TERM 35 1 135 13.50 20 CONDUCTOR SCHEDULE KEY CONDUCTORS CU/AL TYPE LOCATION TRADE A I-#12 ENGAGE CABLE.1-#6G,FREE AIR CU I TC-ER I ARRAY SOLAR B 3-#10, 1-7t10 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR C 3410, 1410 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR D I CAT5E,ETHERNET CABLE I CU I CATSE I INTERIOR I SOLAR 5 6 II Oe o m O O O SEE NOTE 15 10 0 O ® B ISA/IP G O 20A/2P -IN G G Tie ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 3.180 KW LOT#155 : ORIGINAL BY: KIM ABCOUWER DATE: LENNAR I7.01.05 CAMELLIA AT REVIEWED BY:SHAUN MARUNA I DATE:17.01.06 980 MONTECITO DRIVE,#302 THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION 47 namaste SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Brastlwey Streat INDIVIDUAL 30220 SUTTON COURT Boulder,CO B0304 PLOT PLAN 2 NTS MENIFEE,CA 303.447.0300 ELECTRICAL STRUCTURAL NOTES: SOLAR CONTRACTOR- D ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS LL.BESTAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE_. �y. 3)ROOF PENETRATIONS ASSOCIATTED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. - 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL,VERSION 227.3,PUB 1401I3-ICC.JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(1')SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(27 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. ROOFING CONTRACTOR- 1)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. a MEN 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE ��LGIL�, APROVED PRIOR TO FV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT W)OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF SAVE.PEEL-N-STICK BASE TO BE INSTALLED.PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. k 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE.BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. 4 1 _r be a pclmit he(deml,sta 'Pla is must 6 ELECTRICAL NOTES: GENERAL- 1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS, 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE S12ED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 12UV BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT t- 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE:OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. LENNAR: ORIGINAL BY: KIM ABCOUWER DATE:17.01.05 CAMELLIA AT REVIEWED BY: SHAUN MARUNA_ DATE:17.01.06 980 MONTECITO DRIVE,#302 THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION Smmasb6 DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 30220 SUTTON COURT Boulder,CO 80304 PLOT PLAN 3 NTS MENIFEE,CA 303.447.0300 NOTES CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. V PATE ,' a f-7 0iry m DIC SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER 8 N1 MAIN SERVICE PANEL (VERIFIED BY BUILDER) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE ,- AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: 10.8 A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION LENNAR: ORIGINAL BY: KIM ABCOUWER DATE:17.01.05 CAMELLIA AT REVIEWED BY:SHAUN MARUNA DATE:17.01.06 980 MONTECITO DRIVE.#302 THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION d namaste SOLnR DWG TITLE: PAGE*: I SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 30220 SUTTON COURT Boulder,CO BD304 PLOT PLAN 4 NTS MENIFEE,CA 303.447.0300 PLACARDS