PMT17-01190 City of Menifee Permit No.: PMT17-01190
29714 HAUN RD. Type: Residential Electrical
S�CCEL..A7. MENIFEE,CA92586
MENIFEE Date Issued: 0 512 312 01 7
PERMIT
Site Address: 30208 SUTTON CT,MENIFEE,CA 92584 Parcel Number: 364-370-053
Construction Cost: $6,943.00
Existing Use: Proposed Use:
Description of SOLAR TR 30422-3 CAMELLIA
Work: 10 MODULES,2.65KW
LOT 154
Owner Contractor
LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC
980 MONTECITO DR#302 25 ENTERPRISE
CORONA,CA 92879 ATTN GOREEN MUELLER
Applicant Phone:9493498269
JEREMIAH ACAYTURRI License Number:728102
LENNAR HOMES OF CALIFORNIA INC
25 ENTERPRISE
ATTN GOREEN MUELLER
ALSO VIEJO,CA 92656
Fee Description OQt Amount f$1
Solar, Residential or Small Commercial 1 252.00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 1.00
General Plan Maintenance Fee-Electrical 1 12.60
$293.60
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing builiding operations being carded on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bldg_Permit Template.rpt Page 1 of 1
BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION
Menifee
DATE PERMIT/PLAN CHECK NUMBER
TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILE HOME ❑POOL/SPA ❑SIGN
SUBTYPE: ❑✓ ADDITION ❑ALTERATION []DEMOLITION ❑ELECTRICAL ❑MECHANICAL
❑NEW ❑PLUMBING ❑RE-ROOF-NUMBER OF SQUARES
DESCRIPTION OF WORK Solar Permit-Plan 2077-2.65 kW/10 PCS
Master Solar Permit No.:PMT14-02629
PROJECTADDRESS 30208 Sutton Ct,Menifee, CA 92584 2
ASSESSOR'S PARCEL NUMBER 3Gy- � 0 — 057 LOT 154 TRACT 30422-3
PROPERTY OWNER'S NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr.,suite 302,Comna,CA 92879
PHONE (951)817-3680 EMAIL leremlah.acayturri@lennar.com
APPLICANT NAME Lennar Homes of California, Inc.
ADDRESS 980:Montecito.Dr.,suite 302,Corona,CA 92879
PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com
CONTRACTOR'S NAME Lennar Homes of California,Inc. OWNER BUILDER? ❑✓ YES❑NO
BUSINESS NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879
PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com
CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B
VALUATION$ $6,943.00 L SQ FT
APPLICANT'S SIGNATURE DATE 04/06/2017
DEPARTMENT DISTRIBUTION II•p CITY OF MENIFEE BUSINESS LICENSE NUMBER
BUILDING PLANNING ENGINEERING FIRE GREEN l I SMIP
INVOICE A�• PAIDAMOUNT
AMOUNT 1 OCASH OCHECK# 0CREDIT CARD VISA/MC
PLAN CHECK FEES PAID AMOUNT 0CASH 0CHECK# OCREDITCARD VISA/MC
OWNER BUILDER VERIFIED OYES O NO DL NUMBER NOTARIZED LETTER ;- YES G NO
City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777
www.cityofinenifee.us Inspection Request Line 951-246-6213
SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED
ITEM OTY MFR. 1 MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE
SYSTEM SIZE 2.650 KW I I LOCATIONS INDICATED BY THE ILLUSTRATION.
MODULE IO PC&I HYUNDAI I HIS-S265RG(265W) I BUYER:
INVERTER to PCS.1 ENPHASE .1,M215-60-2LL-S22-IG ._ .
ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE:
SUB-ARRAY INFORMATION
ARRAY#1 ARRAY#2 ARRAY#3 CITY OF ENI
MOD OTY 10 NA NA BUYER:
TILT 23° NA° NA' GATE: BUILDING AN)
AZIMUTH 270° NA' NA'
N APf ROV
REVIEWED Y�(
City of Menifee
Building Dept Approval of the c plans
approval of,any violaliL
APR 2 0 2017 rcgulalions and rdinan,
jobsite until com pltio,,
Received
-------- ----------- ----
I
TRANSIT O WIRE 19'-9'FLASHING
I
V
TRANSITION BOX 20'-7'FLASHING 13'-II- I
(UNDER ARRAY)
fro
_ aaaaataO
/tea!
PV AC DISCONNECT
EXTERIOR-GARAGE �aT/
UTILITY METER
MAIN SERVICE PANEL
(VERIFIED BY BUILDER)
NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF
Z
PLAN 2077 ELEVATION C-L
O N ION I LO 1#154
CAMELLIA' AT--- LENNAR: ORIGINAL BY: KIM ABCOUWER I DATE:17.01.05
980 MONTECITO DRIVE,#302 REVIEWED BY:SHAUN MARUNA I DATE:17.01.06
THE LAKES CORONA.CA 92879 REV.# BY DATE DESCRIPTION
GO n Mast6
SOLAR
DWG TITLE: PAGE#: SCALE: SITE LOCATION:. 4571 Broadway Street
INDIVIDUAL 30208 SUTTON COURT Boulder.CO 80304
PLOT PLAN I. 1/16'= 1'-0- MENIFEE.CA 003.447.0300
SYSTEM LAYOUT
MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS
ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL
LOCATION MENIFEE,CA INV. MAKE INVERTER SPEC ENPHASE
TEMP,AMBIENT HIGH(THAX) ASHRAE 2% 'C 37 INV.MODEL INVERTER SPEC I M215-60-2LL-S22-IG
..^^� ..TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN `C _ -2_ ..... ..�_ „ .INV..MAX POWER,(Wnc MAX) INVERTER SPEC WATTS(Ac 225.
TEMP,MODULE TEST(TTEST) MODULE SPEC PC 25 INV. INPUT V,(VDG MAX) INVERTER SPEC VOLTS(DO 48
TEMP,DELTA LOW(TOELTA) THIN-TTEST 'C -27 INV.OUTPUT V,(VAC MOM) INVERTER SPEC VOLTS U0 240
MOD. MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60
MOD.PART NUMBER MODULE SPEC HIS-S265RG INV.OUTPUT CURRENT,IAC INVERTER SPEC AMPS(AC) 0.9
MOD.POWER STC(P) MODULE SPEC WATTS(oc) 265 INV.PHASE QUANTITY INVERTER SPEC PHASE I
MOD. POWER FTC MODULE SPEC WATTS(00 238 COMPLIANCE INVERTER SPEC UL17411IEEEI547 NAVETY
MOD. OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(OC) 31.30 INV.GROUNDING INVERTER SPEC ISOLATED
MOD.OPEN CCT.VOLTAGE(VOC) MODULE SPEC VOLTS(Dc) 38.10 INV.OTY,MAX/BRANCH CCT. INV.OTY8c OTY 10
MOD.COEFF. VOLT/TEMP(COEF) MODULE SPEC V/°C -0.114 BRANCH CCT. OUTPUT,IMAXBC UAC'NV.OTYec) AMPS(ACI 9.00
MOD.MAX VOLTAGE(VMAXMOD) (VOC+(TOCOEF)) VOLTS(x) 41.18 INV.QUANTITY,TOTAL INV.OTYT OTY 10
MOD.OPERATING CURRENT(IMP) MODULE SPEC AMPS(Oc) 8.50 TOTAL SYSTEM OUTPUT,MARTS (IAC-INV.QTYT) AMPS(AC) 9.00
MOD.SHORT CCT. CURRENT(Isc) MODULE SPEC AMPS(OC) 9.00
MOD.MAXIMUM CURRENT OMAx) (Isc• 1.25) AMPS(DC) 11.25
MIN. AMPACITY REO'D,PER NEC ([MAX•1.25) AMPS(DO 14.06
SERIES FUSE RATING,MAX MODULE SPEC AMPS(DC) 15 it n I he col
ELECTRICAL EQUIPMENT SCHEDULE N y provie
KEY OTY MANUFACTURER MODEL NOTES TRADE III 'eat OL
1 10 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR
2 10 ENPHASE M215-60-2LL-S22-IG PV INVERTER SOLAR
3 1 RSTC/SOLADECK 0786-3115 PV ROOF JUNCTION BOX,NEMA 3R SOLAR
4 1 CUTLER-HAMMER D6221URB PV AC DISCONNECT,NEMA 3R.24OV,30A SOLAR
5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR
6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR
7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR
8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS I X 15A-IP(ENVOY) SOLAR
9 NOTE CUTLER-HAMMER TBD PV BREAKER,I X 20A-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR
10 I TBD TBD SERVICE PANEL,MIN. 125A BUS BLDR.ELEC,
11 1 TBD TBD UTILITY METER,IPH.120/Z40V.200A BLDR.ELEC.
12 1 1 TBD I TBD I GROUNDING ELECTRODE UFER BLDR.ELEC.
CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS
1)CONDITION OF USE(COU): I(AMPACITY•TEMP.DERATE•FILL DERATE) es.REQ'D(IMAX) ITEM UNIT PANEL
2)TERMINALS(TERWJ1 I AMPACITY AT TERMINALS. Vs. REG-D.(IMAX• 1.25) PANEL MFR. CUTLER-HAMMER
KEY SIZE CU/AL INSULATION CALC' AMPACITY W/O TEMP. FILL RESULT REO'D 000 BUS RATING AMPS ZOO
TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS ZOO
A #12 CU I THWN-2 COU 30 0.76 1.0 22-80 9.00 ALLOWED PV PER NEC AMPS 40
TERM 25 25 11.25 20 PV OCPD DEVICE USED AMPS 20
B #10 CU NM-B COU 40 0.91 1.0 36.40 9.00
TERM 35 35 11.25 20
L #10 CU NM-B COU 40 0.91 1.0 36.40 9.00
TERM 1 35 35 11.25 20
CONDUCTOR SCHEDULE
KEY CONDUCTORS CU/AL TYPE LOCATION TRADE
A I-#12 ENGAGE CABLE, -#6G.FREE AIR CU TL-ER ARRAY SOLAR
B 1 3-#10.I-#10 EGC I CU NM-B(ROME%) I NTERIOR SOLAR
C 3-#10.I-#10 EGC CU NM-8(ROMEX) INTERIOR SOLAR 5 6 II
D CATSE,ETHERNET CABLE CU CAT5E INTERIOR SOLAR O o 0
n O
SEE NOTE 15 10
O
Isa1P
9
O O 2BOP
3
N
G G G�
A B C
ROOF EXTERIOR-GARAGE
ELECTRICAL DIAGRAM 2.650 KW
LOT#154
LENNAR: ORIGINAL BY: KIM ABCOUWER DATE:17.01.05
CAMELLIA AT REVIEWED BY:SHAM MARUNA DATE:17,01.06
980 MONTECITO-DRIVE,4302
THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION
Qti namastA
SOLAR
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Bmedway Street
INDIVIDUAL 30208 SUTTON COURT Boulder,CO 803N
PLOT PLAN 2 NTS MENIFEE,CA 303.447.0300
ELECTRICAL
STRUCTURAL NOTES:
SOLAR CONTRACTOR-
1)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C.
2)ALL PV ROOF ATTACHMENTS WILL BE-STAGGEREDBY ROW AMONGST THE ROOF FRAMING MEMBERS.TO MAXIMUM EXTENT POSSIBLE. w),_;. :;
3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RAe(I ING WILL BE-SEALED WITH AN APPROVED SEALANT.
4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED.
5)PV ARRAY WILL BE A MINIMUM OF 3-ABOVE THE COMPOSITE SHINGLE ROOF SURFACE.
6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION
MANUAL,VERSION 227.3.PUB 140113-ICC,JANUARY 2014.
7)UNIRAC TOP CLAMPS REQUIRE AONE INCH(1")SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MIST EXTEND A MINIMUM OF TWO INCHES(27 BEYOND THE EDGE
OF THE PV ARRAY/SUR-ARRAY.
8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'.
ROOFING.CONTRACTOR- .PAR MEN
U DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'.
2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION.IT SHALL BE
APROVED PRIOR TO PV SYSTEM INSTALLATION.
3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT 00 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE.DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE T(
BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS.
Q_
4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE.
5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS.
6)BIROSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO i/{I
INSTALLATION. d to be permit
, the C deryl,sty
Ted pla 1,must b
ELECTRICAL NOTES:
GENERAL-
0 ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL).
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC.
3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC
WELD.
4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE
MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH, PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED.
5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE.
6)ALL CONDUCTORS WILL HAVE A 90°C RATING TO ENSURE CODE COMPLIANCE.
SOLAR CONTRACTOR-
7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730.
8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS.
9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS.
10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM.
11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE
ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER.
12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122.
13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS.
14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT.
15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR.
SIGNAGE-
16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES.
17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS.
18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT t.
19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10%
BUILDER ELECTRICAL AND SOLAR CONTRACTORS-
20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER.
21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26.
I� LENNAR: ORIGINAL BY: KIM ABCOUWER DATE:17.01.05
CAMELLIA
IELL�A AT
980 MONTECITO DRIVE,#302 REVIEWED BY: SHAUN MARUNA . DATE:17.01.06
- - -
THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION
u namaste
some
OWG TITLE: PAG711SCALE: SITE LOCATION: 4,571 BroadWayStreatINDIVIDUAL 30208 SUTTON COURT Boulder,CO B0304PLOT PLAN 3NTS MENIFEE.CA 303.447.0300
NOTES
CAUTION:
POWER TO THIS BUILDING IS SUPPLIED BY THE
UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS
ARE LOCATED AS SHOWN.
,A
n
my
un tllc
SOLADECK WIRE
TRANSITION BOX
(UNDER ARRAY)
PV AC DISCONNECT
EXTERIOR-GARAGE
UTILITY METER 8
MAIN SERVICE PANEL
(VERIFIED BY BUILDER)
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
1-877-SLR-POWR
PV POWER SOURCE - AC SPECS
AC OPERATING VOLTAGE: 240 V
AC OPERATING CURRENT: 9.0 A
NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION
LENNAR: ORIGINAL BY: KIM ABCOUWER DATE:17.01.05
CAMELLIA.-AT - 980 MONTECITO DRIVE,#302 REVIEWED BY:SHAUN MARUNA I DATE:17.01.06
THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION
namaste
SOLAR
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Bmacl ay Street
INDIVIDUAL 30208 SUTTON COURT Boulder,CO 80304
PLOT PLAN 4 NTS MENIFEE,CA 303.447.0300
PLACARDS