Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
PMT17-01189
City of Menifee Permit No.: PMT17-01189 29714 HAUN RD. Type: Residential Electrical <ACCEL/-> MENIFEE,CA 92586 !rA.- MENIFEE Date Issued: 05/23/2017 PERMIT Site Address: 30184 SUTTON CT, MENIFEE, CA 92584 Parcel Number: 364-370-052 Construction Cost: $7,650.40 Existing Use: Proposed Use: Description of SOLAR TR 30422-3 CAMELLIA Work: 11 MODULES,2.92KW LOT 153 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA,CA 92879 ATTN GOREEN MUELLER Applicant Phone:9493498269 JEREMIAH ACAYTURRI License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO,CA 92656 Fee Description QtY Amount($) Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing building operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced Is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit Templatexpt Page 1 of 1 PERMIT/PLANBUILDING & SAFETY, A. • • . ,�Menifee DATE PERMIT/PLAN CHECK NUMBER P dill a TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILEHOME ❑POOL/SPA []SIGN SUBTYPE: ❑✓ ADDITION ❑ALTERATION [-]DEMOLITION []ELECTRICAL ❑MECHANICAL ❑NEW ❑PLUMBING El RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit-Plan 2399-2.92 kW/11 PCS Master Solar Permit No.: PMT14-02629 PROJECT ADDRESS 30184 Sutton Ct,Menifee, CA 92584 ASSESSOR'S PARCEL NUMBER 36y-370-QSZ LOT 153 TRACT 30422-3 PROPERTY OWNER'S NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,suite 302,Corona, CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@Iennar.com APPLICANT NAME Lennar Homes of California,Inc. ADDRESS 980 Montecito Dr.,suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S NAME Lennar Homes of California,Inc. OWNER BUILDER? ❑✓YES❑NO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ $7,650.40 SO,FT L SO FT APPLICANT'S SIGNATURE DATE 04/06/2017 7NTTRIBUTION (� CITY OF MENIFEE BUSINESS LICENSE NUMBER ING ENGINEERING FIRE GREEN SMIP/, 0PAIDAMOUNT ► 0CASH 0CHECK# OCREDRCARD VISA/MC CK FEES PAIDAMOUNT OCASH 0CHECK# 0CREDIT CARD VISA/MC R VERIFIED OYES O NO DLNUMBER NOTARIZED LETTER O YES C NO City of Menifee Building&Safety Deportment 29714 Houn Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED IT OTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 2.915 KW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 1 II PCS.I HYUNDAI HIS-S265RG(265W) BUYER: INVERTER. I . II PCS. .ENPHASE I MZ15-60-2LL-S22-IG ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: SUB-ARRAY INFORMATION ARRAY#1 ARRAY#2 1 ARRAY#3 MOD OTY II 1 NA NA BUYER: TILT 23° 1 NW I NA° DATE: AZIMUTH 1 90° 1 NM I FM BUiLr ING City of Menifee PLAN PpA Building Dept REVIEWED B1 APR 2 0 2011 APPIrOvalarthowl mpmal lobo ndYrd Received rogu)efions nd Ord iobsha until eumple 19'-9'ARRAY 6'-9' 20'-7'FLASHING t i SOLADEC I V I I — I I I ^ WIRE 1 L TRANSITION BOX (UNDER ARRAY) I � I I PV AC DISCONNECT a — EXTERIOR.-GARAGE ——_ UTILITY METERS MAIN SERVICE PANEL (VERIFIED BY BUILDER) y-—— — — J r NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF z PLAN 2399 ELEVATION C-L ORIENTATION 2 L # 3 LENNAR: ORIGINAL BY: KIM ABCOUWER GATE:17.01.05 CAM ELLIN"AT "" 980 MONTECITO DRIVE,#302 REVIEWED BY:SHAUN MARUNA DATE:17.01.06 THE LAKES CORONA,CA 92579 REV.* BY DATE DESCRIPTION ID namaste SOL R DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 4M B.d.yStreet INDIVIDUAL 30104.SUTTON COURT B.Wk ,C 8030C PLOT PLAN 1 1/16'=1'-0' MENIFEE,CA 3D3b07.0300 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC I UNIT DETAIL LOCATION MENIFEE,CA INV. MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INV. MODEL INVERTER SPEC M215-60-2LL-S22-IG ..TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C_. . .._- -2. i ,INV. MAX POWER,.(WAC MAX) INVERTER SPEC WATTS(AC) .225 _ TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 'INV. INPUT V,NOC MAX) INVERTER SPEC VOLTS(DO 48 - TEMP,DELTA LOW(TDELTA) THIN-TTEST °C -27 INV. OUTPUT V,(VAC MOM) INVERTER SPEC VOLTS(Ac) 240 MOD.MANUFACTURER MODULE SPEC HYUNDAI INV. OUTPUT FREQUENCY INVERTER.SPEC HERTZ 60 MOD.PART NUMBER MODULE SPEC HIS-S265RG INV. OUTPUT CURRENT,IAC INVERTER SPEC AMPS(AC) 0.9 MOD.POWER STC(P) MODULE SPEC WATTS(Da) 265 INV. PHASE QUANTITY INVERTER SPEC PHASE I MOD.POWER PTC MODULE SPEC WATTS(DC) 238 COMPLIANCE INVERTER SPEC UL1741/IEEE1547 MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(De) 31.30 INV. GROUNDING INVERTER SPEC ISOLATED MOD.OPEN CCT.VOLTAGE(Voc) MODULE SPEC VOLTS(oc) 38.10 INV. OTY.MAX/BRANCH CCT. INV.QTYsc OTY 11 MOD.COEFF.VOLT/TEMP(COEF) MODULE SPEC V/"C -0.114 BRANCH CCT.OUTPUT.IMAXHD (IAC°INV.QTYBC) i AMPS(AC) 9.90 MOD.MAX VOLTAGE(VMAXM00) (VOC♦ (TD°COEF)) VOLTS(DC) 41.18 INV. QUANTITY,TOTAL INV.QTYT OTY R MOD.OPERATING CURRENT(IMP) MODULE SPEC AMPS(uc) 8.50 TOTAL SYSTEM OUTPUT,IMAXTS (IAC-INV.OTYT) I AMPS(Ac) 1 9.90 J12 AFE7 MOD.SHORT CCT. CURRENT(Isc) MODULE SPEC AMPS(DD) 9.00 VAJ MOD.MAXIMUM CURRENT(TMAX) OSC° 1.25) AMPS(DO 11.25 MIN.AMPACITY REO'D,PER NEC (IMAX•1.25) AMPS(00 14.06 SERIES FUSE RATING,MAX MODULE SPEC AMPS(uc) 15 ELECTRICAL EQUIPMENT SCHEDULE KEY QTY MANUFACTURER MODEL I NOTES TRADE I It HYUNDAI HIS-S265RG (265W) PV MODULE SOLAR 2 II ENPHASE M215-60-2LL-S22-IG PV INVERTER SOLAR s Sha1 n01 ho 3 1 RSTC/SOLAOECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 4 1 CUTLER-HAMMER OG221URB PV AC DISCONNECT,NEMA 3R,24OV.30A SOLAR ...n of any pro' 5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR Kcs.I his s6(1 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR 8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS;I x 15A-IP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBD PV BREAKER', I X 20A-2P.LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 TBO TBD SERVICE PANEL.MIN. 125A BUS SLOR.ELEC. II TBD TBD UTILITY METER, IPH, 120/240V,200A BLDR.ELEC. 12 TBD TBD GROUNDING ELELTRODE UFER BLDR.ELEC. CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS U CONDITION OF USE(COU): I (AMPACITY°TEMP.DERATE °FILL DERATE) vs.REQ'D.(IMAX) ITEM UNIT PANEL 2)TERMINALS(TERM): AMPACITY AT TERMINALS. VS.REQ'D,(IMAX' 1.25) PANEL MFR. CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALC' AMPACITY WO TEMP. FILL RESULT REO'D OCD BUS RATING AMPS 200 TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 A 412 CU THWN-2 COU 30 0.76 1 LO 22.80 9.90 ALLOWED PV PER NEC AMPS 40 TERM 25 1 25 12.30 1 20 PV OCPD DEVICE USED AMPS 20 B #10 CU NM-B COU 40 0.91 1.0 36.40 9.90 TERM 35 35 12.38 20 C #10 CU NM-B COU 40 0.91 L0 36.40 9.90 TERM 35 35 12.38 20 CONDUCTOR SCHEDULE KEY CONDUCTORS 1 CU/AL TYPE 1 LOCATION TRADE A I-#12 ENGAGE CABLE, I46G,FREE AIR I CU I TC-ER I ARRAY SOLAR B 3-#10,I-#10 EGG I CU I NM-B(ROMEX) I INTERIOR I SOLAR C 1 3-#10,1410 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR SQ © II D I CAT5E.ETHERNET CABLE I CU I CATSE INTERIOR I SOLAR O n o M — SEE NOTE 15 10 O ISAIIP O O 20O N G GT l I A 9 ( = 12 ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.915 KW LOT# 153 LENNAR: ORIGINAL BY: KIM ABCOUWER DATE: 90 MONTECITO DRIVE:#302 I7.01.05 CAMELLIA AT REVIEWED BY:SHAUN MARUNA DATE:17.01.06 0 ' THE LAKES CORONA.CA 92879 REV.# BY DATE DESCRIPTION 4;l4 namaste SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION. 457(Bmadvrey Street INDIVIDUAL 30184 SUTTON COURT Boulder,CO 80304 PLOT PLAN 2 NTS MENIFEE,CA 303.447.0300 ELECTRICAL STRUCTURAL NOTES: SOLAR CONTRACTOR- U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. _ 2)ALL PV ROOF ATTACHMENTS WILL.BESTAGGERED.BY ROW.AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM__EXTENT.POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOCAR RACRNGING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL,VERSION 227.3,PUB 140113-ICC.JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(I')SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(27 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. ROOFING CONTRACTOR- U DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL-TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION.IT SHALL BE I IEPAR MEN APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT 01 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE.DOWN TO THE ROOF EAVE.PEEL-N-ST(CK BASE IO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVES 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. /t 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE.BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO lJl� INSTALLATION. L rucd t0 b a permit a>of the ederal,st proved pi m must I ELECTRICAL NOTES: GENERAL- U ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/GEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR.EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703.IEC61646.IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. IU MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS. WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT i'. 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. LENNAR: ORIGINAL BY: KIM ABCOUWER I DATE:17.01.05 CAMELLIA AT 980 MONTECITO DRIVE.#302 REVIEWED BY: SHAUN MARUNA DATE:17.01.06 THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION namasbe $01�t DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Smadway Si cl INDIVIDUAL 30184 SUTTON COURT Boulder,CO 80304 PLOT PLAN 3 KITS MENIFEE.CA 303.447.0300 NOTES CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. remr aD city 1 on the SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER& MAIN SERVICE PANEL (VERIFIED BY BUILDER) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP I-877-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: 9.9 A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION LENNAR: ORIGINAL BY: XIM ABCGUWER I DATE:17.01.05 CAMELLIA AT 980 MONTELITO DRIVE.#302 REVIEWED BY:SHAUN MARUNA I DATE:17.01.06 THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION namasbe DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Slnel INDIVIDUAL 30184 SUTTON COURT Boulder GO 60304 PLOT PLAN 4 NTS MENIFEE,CA 303.447.0300 PLACARDS