Loading...
PMT17-01188 City of Menifee Permit No.: PMT17-01188 29714 HAUN RD. <-CC A? MENIFEE,CA 92586 Type: Residential Electrical MENIFEE Date Issued: 0 5/2 312 01 7 PERMIT Site Address: 30172 SUTTON CT, MENIFEE,CA 92584 Parcel Number: 364-370-051 Construction Cost: $6,943.00 Existing Use: Proposed Use: Description of SOLAR TR 30422-3 CAMELLIA Work: 10 MODULES,2.65KW LOT 152 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA,CA 92879 ATTN GOREEN MUELLER Applicant Phone:9493498269 JEREMIAH ACAYTURRI License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO, CA 92656 Fee Description Div Amount(Sl Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work Is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Template.rpt Page 1 of 1 BUILDING & SAFETY PERMIT/PLAN CHECKAPPLICATION Menifee n6 DATE PERMIT/PLAN CHECK NUMBER O'Ia D TYPE: []COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY [-]MOBILE HOME ❑POOL/SPA []SIGN SUBTYPE: [E]ADDITION ❑ALTERATION ❑DEMOLITION ❑ELECTRICAL ❑MECHANICAL ❑NEW []PLUMBING FIRE-ROOF-NUMBEROFSC.UARES DESCRIPTION OF WORK Solar Permit-Plan 2077-2.65 kW/10CS Master Solar Permit No.:PMT14-02629 PROJECTADDRESS 30172 Sutton Ct, Menifee,^CA 92584 ASSESSOR'S PARCEL NUMBER Wye 3 /7Q—QS-t LOT 152 TRACT 30422-3 PROPERTY OWNER'S NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL leremiah.acaytuni@lennar.com APPLICANT NAME Lennar Homes of California,Inc. ADDRESS 980 Montecito Dr.,suite 302,Carona,CA 92879 PHONE (951)817-3680 EMAIL leremiah.acayturri@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNERBUILDER7 ❑✓ YES❑NO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL leremiah.acayturri@lenner.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ $6.943.00 SO FT L SO.FT APPLICANT'S SIGNATURE DATE 04/06/2017 DEPARTMENT DISTRIBUTION '.N �to CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN too SMIP INVOICE PAID AMOUNT AMOUNT C CASH 0CHECK# OCREDITCARD VISA/MC PLAN CHECK FEES PAID AMOUNT 0CASH 0CHECK# OCREDITCARD VISA/MC OWNER BUILDER VERIFIED OYES O NO DL NUMBER NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Department 29714 Houn Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTV MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 2.650 KW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE IO PCS. HYUNDAI I HIS-S265RG(265W) BUYER: INVERTER 1 IO PCS..I ENPHASE .MM5,60-2LL-S22-IG ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: SUB-ARRAY INFORMATION ARRAY#1 ARRAY#2 ARRAY#3 CITY OF ENT MOD OTY IO NA NA BUYER: faT TiT DIN ANI TILT 23° NA. NA' AZIMUTH 253° NA* NA' DATE: PLAN Ai ,4 QV City of Menifee *VIEWED11Y6 Building Dept NI'Pf"Val Oftbc,C plans APR 2 0 2017 4PPcl`val Of,any violatic mgulutions and I rdinan( Receive jobsite until com Iction. - 1 t 19'-'-7' ARRAY , SOLAOECK WIRE 20FLASHING 13'-3' V TRANSITION BOX (UNDER ARRAY) I 00 PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER 6 O MAIN SERVICE PANEL (VERIFIED BY BUILDER) L———— ---� - -- - - NOTE:DIMENSIONS ARE SHOWN IN FLAME OF ROOF 2® PLAN 2077 ELEVATION B-L ORIENTATION I LO I# IbO CAMELLIA AT LENfIAR: ORIGINAL BY: KIM ABCOUWER DATE:I7.01.05 980 MONTECITO DRIVE,#302 REVIEWED BY:SHAUN MARUNA I'DATE:17.01.06 THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION narnasGA DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Saeel INDIVIDUAL 30148 SUTTON COURT BauldeA GO 0304 PLOT PLAN I/16-=I'-0* MENIFEE,CA 303.4474300 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE /CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE,CA INV. MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH(TMAx) ASHRAE 2% °C 37 INV. MODEL INVERTER SPEC M215-60-2LL-S22-IG .TEMP,.AMBIENT.LOW.(THW). ASHRAE EXTR.MIN °C -2 INV. MAX_FOWER..(WA4MAX) INVERTER SPEC WATTS(AC) 225 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V.(PoD MAX) INVERTER SPEC VOLTS(DC) 48 TEMP.DELTA LOW(TOFITA) THIN-TTEST °C -27 INV. OUTPUT V,(VAC NOM) INVERTER SPEC VOLTS(A0 240 MOD. MANUFACTURER MODULE SPEC HYUNDAI INV. OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD. PART NUMBER MODULE SPEC HIS-S265R6 INV. OUTPUT CURRENT.Inc INVERTER SPEC AMPS(AC) 0.9 MOD.POWER STC(P) MODULE SPEC WATTS(oc) 265 INV. PHASE QUANTITY INVERTER SPEC PHASE I I- MOD.POWER PTC MODULE SPEC WATTS(DO 238 COMPLIANCE INVERTER SPEC UL1741/IEEE1547 MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(Dc) 31.30 INV. GROUNDING INVERTER SPEC ISOLATED TY I MOD-OPEN CCT.VOLTAGE(Voc) MODULE SPEC VOLTS(Dc) 38.10 INV. QTY.MAX/BRANCH CCT. INV.QTYBC OTY 10 MOD.COEFF.VOLT/TEMP(COEF) MODULE SPEC V/°C -0.114 BRANCH CCT.OUTPUT.IMAXBC I (IAC'lNV.GTYBC) I AMPS(AC) 9.00 MOD.MAX VOLTAGE(VMAXMOD) (VOC+(TVCOEF)) VOLTS(Dc) 41.18 INV. QUANTITY,TOTAL I INV.OTYi I OTY 10 MOD.OPERATING CURRENT(IMP) MODULE SPEC AMPS(DO 8.50 TOTAL SYSTEM OUTPUT,IMAXTS (IAc•INV.GTYT) I AMPS(AC) 9.00 MOD-SHORT CCT.CURRENT(Isd MODULE SPEC AMPS DX) 9.00 MOO.MAXIMUM CURRENT(IMAX) (Isc° 1.25) AMPS(DC) 11.25 MIN. AMPACITY REO'D,PER NEC (IMAX• 1.25) AMPS(DO 14.06 SERIES FUSE RATING,MAX MODULE SPEC AMPS(DC) 15 ELECTRICAL EQUIPMENT SCHEDULE 11 no be cans KEY OTY MANUFACTURER MODEL NOTES TRADE Iany PTDVIBII 1 10 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR ['his mto(•( 2 10 ENPHASE M215-60-2LL-S22-IG PV INVERTER SOLAR 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 4 I CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,24OV,30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR 8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS;I x I5A-IP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBD PV BREAKER,I x 20A-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 1I I TBD TBD SERVICE PANEL,MIN. 125A BUS BLDR.ELEC. II I TBD TBD UTILITY METER,IPH,1201240V,200A BLDR.ELEC. 12 11 1 TBD I TBD GROUNDING ELECTRODE UFER BLDR.ELEC- CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS U CONDITION OF USE(COU): (AMPACITY°TEMP.DERATE°FILL DERATE) vs.REQ'D(IMAX) ITEM UNIT PANEL 2)TERMINALS(TERM): AMPACITY AT TERMINALS. Vs-REQ'D,(IMAX• 1.25) PANEL MFR. CUTLER-HAMMER KEY SIZE CU7AL INSULATION CALC. AMPACITY W/O TEMP. FILL W3511.25 Q'D OCD BUS RATING. AMPS 200 TYPE DERATES DERATE DERATE USED(A) MAIN DISCONNECT AMPS 200 A #12 CU THWN-2 COU 30 0.76 1.0 0 ALLOWED PV PER NEC AMPS 4D TERM 25 5 20 PV OCPD DEVICE USED AMPS 20 B #to Cu NM-B COU 40 0.91 1.0 0 TERM 35 5 20 C #10 CU NM-B COU 40 0.91 I.0 0 TERM 35 5 20 CONDUCTOR SCHEDULE KEY CONDUCTORS CU/AL TYPE LOCATION TRADE A I-#12 ENGAGE CABLE.I-96G.FREE AIR I CU I TC-ER JARRAY SOLAR B 1 3-#10.1-810 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR C 1 3ANO.1410 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR O © II D I CAT5E.ETHERNET CABLE I CU I CAT5E I INTERIOR I SOLAR 7 • oO — SEE NOTE 15 10 5A ISA/IP O O OO 20A/2P 3 L�N G G G� A B C = 12 ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 2.650 KW LOT#150 LENNAR: ORIGINAL BY: KIM ABCOUWER DATE:17.01.05 980 MONTECITO DRIVE.#302 CAMELLIA. AT REVIEWED BY;SHAUN MARUNA DATE:17.01.06 THE LAKES CORONA.CA 92879 REV.# BY DATE DESCRIPTION Sa IAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 30148 SUTTON COURT Boulder,CO 80304 PLOT PLAN 2 NTS MENIFEE,CA 303.447.0300 ELECTRICAL STRUCTURAL NOTES: SOLAR CONTRACTOR- U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. .. _ 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED,BY.ROW.AMONGST..SHE•ROOF FRAMING MEMBERS.TO MAXIMUM EXTENT POSSIBLE. -( 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACIZNG WILL BE BEA D WITH A}J APPROVED SEALMIT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3-ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL,VERSION 227.3,PUB 140113-ICC,JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(P)SPACE BETWEEN PV MODULES:SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND THE EDGE OF THE PV ARRAY/SUR-ARRAY. FART VIFNT 0)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. ROOFING CONTRACTOR- 1)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. UQ 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT W)OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. 5)TILE INSTALLED BELOW THE ARRAY TO.BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE.SIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO t0 be a (p INSTALLATION. "the federal,state. eed plans nust be 1< ELECTRICAL NOTES: GENERAL- U ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646.IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING.OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING /PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT t. 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE.-OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 11026. LENNAR: ORIGINAL BY: KIM ABCOUWER DATE:I7 AI.OS CAMELLIA AT 980 MONTECITO DRIVE,#302• REVIEWED BY: SHAUN MARUNA DATE:17.01.06 - 'THE LAKES CORONA,CA 92679 REV.# BY DATE DESCRIPTION to n• amasGe' .er.. DWG TITLE: PAGE#: I SCALE: SITE LOCATION:; 4571 Broadway SVeet INDIVIDUAL 30149 SUTTON COURT Boulder,CO a03O4 PLOT PLAN 3 NTS MENIFEE,CA 303.447.0300 NOTES CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. a icy on the SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER 8 MAIN SERVICE PANEL (VERIFIED BY BUILDER) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP I-877-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: 9.0 A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION LENNAR: ORIGINAL BY: KIM ABCOUWER DATE:17.01.05 CAMELLIA AT REVIEWED BY:SHAUN MARURA" DATE:O.01.06 980 MONTECITO DRIVE,#302 THE LAKES CORONA,CA 92879 REV.# BY DATE I DESCRIPTION o namaste SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 401 Broadway Street INDIVIDUAL 30148 SUTTON COURT Baulder,CO 80304 PLOT PLAN 4 NTS MENIFEE,CA 303.447.0300 PLACARDS