Loading...
PMT17-00990 City of Menifee Permit No.: PMT17-00990 29714 HAUN RD. < -\CCEt-A-. MENIFEE, CA 92586 Type: Residential Plumbing MENIFEE Date Issued: 04/04/2017 PERMIT Site Address: 30331 MOON STAR CIR, MENIFEE, CA Parcel Number: 360-640-033 92584 Construction Cost: $5,000.00 Existing Use: Proposed Use: Description of REPLACE EXISTING WATER HEATER WITH TANKLESS WATER HEATER IN GARAGE, 30 L FT GAS Work: LINE Owner Contractor FRANK PRATHER TOTAL COMFORT INC 30331 MOON STAR CIR 390 E HARRISON STREET MENIFEE, CA 92584 CORONA,CA 92879 Applicant Phone:9517352574 STEVEN SCHNIERER License Number.935238 TOTAL COMFORT INC 390 E HARRISON STREET CORONA, CA 92879 Fee Description Oft t Amount(SI Plumbing Fixtures and Vents,fixtures 1 116.00 Residential Water Heater 1 83.00 Building Permit Issuance 1 27,00 GREEN FEE 1 1.00 General Plan Maintenance Fee-Plumbing 1 9.95 $236.95 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carded on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit Template.rpt Page 1 of 1 CITY OF MENIFEE LICENSED DECLARATION property who builds or improves thereon,and who contracts for the projects I hereby affirm under penalty of perjury that I am under provisions of with a licensed contractor(s)pursuant to the Contractors State License Law). Chapter9(commencing with section 7000)of Division 3 of the Business and to I am exempt from licensure under the Contractors State License Lawfor Professions Code and my license is in full force and effect. the following reason: pn License Class C_10 !C 3b License f o. 3 By my signature below I acknowledge that,except for my personal residence Expires-7 3( l�I Signature in which I must have resided for at least one year prior to completion of improvements covered by this permit.I cannot legally sell a structure that I WORKER'S COMPENSATION DECLARATION have built as an owner-builder if it has not been constructed in its entirety by in I hereby affirm under penalty of perjury one of the following declarations:I licensed contractors.I understand that a copy of the applicable law,Section have and will maintain a certificate of consent of self-insure for workers 7044 of the Business and Professions Code,is available upon request when compensation,issued by the Director of Industrial Relations as provided for this application is submitted or at the following website: by Section 3700 of the Labor Code,for the performance of work for which this permit is issued. www.leeinfo.ca.gov/calaw.html. Policy# Date have and will maintain workers compensation insurance,as required by PROPERTY OWNER OR AUTHORIZED AGENT section 3700 of the Labor Code,for the performance of the work for which o By my signature below I certify to each of the following:I am the property this permit is issued.My workers compensation insurance carrier and policy owner or authorized to act on the property owners behalf.I have read this number aar� OT ree:: ( 4�1 t r � application and the information I have provided is correct.I agree to comply Carrier `5• Cu e z!S.L, with all applicable city and county ordinances and state laws relating to /y building construction.I authorize representatives of this city or county to Policy#l/✓.7�TjOZ 10 5to Expires enter the above identified property for inspection purposes. (This section need not to be completed is the permit is for one-hundred Date dollars($100)or less PROPERTY OWNER OR AUTHORIZED AGENT o I certify that in the performance of the work forwhich this permit is issued, I shall not employ any persons in any manner so as to become subject to the CITY BUSINESS LICENSE# workers compensation laws of California,and agree that if 1 should become HAZARDOUS MATERIAL DECLARATION subject to the workers comp ation provisions of Section 3700 of the Labor Code,lshall forthw'h o I with those provisions. 'D Will the applicant or future building occupant handle hazardous material ora Applicant Date `l 7 mixture containing a hazardous material equal to or greater that the amounts specified on the Hazardous Materials Information Guide? WARNING:FAILURE TO SECURE WORKER'S COMPENSATION COV RAGE IS o Yes o No UNLAWFUL,AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES Will the intended use of the building by the applicant or future building AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS($100,000),IN occupant require a permit for the construction or modification from South IN SECTIONON 3 THE COST LABOR CODE,INTERTION,DAMAGES ATTORNEYS PROVIDED S Coast Air Quality Management District(SCAQMD)?See permitting checklist IN SECTION 3706 OF THE LABOR CODE,INTEREST,ANDAITORNEYS FEES for guidelines CONSTRUCTION LENDING AGENCY o Yes ❑No I hereby affirm that under the penalty of perjury there is a construction Will the proposed building or modified facility be within 1000 feet of the lending agency for the performance of the work which this permit is issued outer boundary of school? (Section 3097 Civil Code) o Yes o No OWNER BUILDER DECLARATIONS I have read the Hazardous Material Information Guide and the SCAQMD 1 hereby affirm under penalty of perjury that I am exempt from the permitting checklist.I understand my requirements under the State of Contractors License Law for the reason(s)indicated below by the California Health&Safety Code,Section 25505 and 2S534 concerning hazardous material reporting. checkmark(s)I have placed next to the applicable items)(Section 7031.5 ciYes o No Business and Professions Code).Any city or county that requires a permit to Date construct,alter,improve,demolish or repair any structure,prior to its PROPERTY OWNER OR AUTHORIZED AGENT issuance,also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors State EPA RENOVATION,REPAIR AND PAINING IRKPI License Law(Chapter 9(commencing with Section 7000)of Division 3 of the The EPA Renovation,Repair and Painting(RRP)Rule requires contractors Business and Professions Code)or that he or she is exempt from licensure receiving compensation for most work that disturbs paint in a pre-1978 and the basis for the alleged exemption.Any violation of Section 7031.5 by residence or childcare facility to be RRP-certified firms and comply with an Applicant for a permit subjects the applicant to a civil penalty of not more required practices.This includes rental property owners and property than($500). managers who do the paint-disturbing work themselves or through their o I,as owner of the property,or my employee with wages as their sole employees.For more information about EPA's Renovation Program visit: compensation,will do( )all of or( )portion of the work,and the structure is www.ena.eov/lead or contact the National Lead Information Center at not intended or offered for sale.(Section 7044,Business and Professions 1-800-424-LEAD(5323). Code,The Contractors State License Law does not apply to an owner of a o An EPA Lead-Safe Certified Renovator will be responsible for this project property who,through employees'or personal effort,builds or Improves the property provided that the improvements are not intended or offered for Certified Firm Name: sale.If,however,the building or improvement is sold within one year of Firm Certification No: completion,the Owner-Builder will have the burden of proving that it was not built or improved for the purpose of sale. ❑No EPA Lead-Safe Certified Firm is required for this project because: o 1,as owner of the property am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractors State License Law does not apply to an owner of a If your project does not comply with EPA RRP rule please fill out the RRP Acknowledgement. ABUILDING & SAFETY PERMIT/PLAN CHECK PPLICATION Menifee DATE 0 4/0 312 0 1 7 PERMIT/PLAN CHECK NUMBER - GC) TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL MULTI-FAMILY ❑MOBILEHOME ❑POOL/SPA ❑SIGN SUBTYPE: ❑ADDITION ❑ALTERATION [-]DEMOLITION ❑ELECTRICAL ❑MECHANICAICity Of Meni ee ❑NEW ❑✓ PLUMBING ❑RE-ROOF-NUMBEROFSQUARES Building & Safet I Dept. DESCRIPTION OF WORK Tankless water heater in garage APR 011 PROJECT ADDRESS 30331 Moon Star Circle z'�, -y.,ry, �q/�jece `-''� ASSESSOR'S PARCEL NUMBER ,'�� - L - �✓5 LOT ✓"5 TRACT c,-p L OWNER NAME Frank Prather ADDRESS 30331 Moon Star Circle Menifee,CA 92584 PHONE (951)242-0480 EMAIL APPLICANT NAME Steven Schnierer ADDRESS 31225 La Baya Drive Suite 112 Westlake Village,CA 91362 PHONE (818)735-7876 EMAIL CONTRACTOR'S NAME OWNER BUILDER? ❑YES ONO BUSINESS NAME Total Comfort Inc. ADDRESS 390 E Harrison Street Corona,CA 92879-1311 PHONE (951)735-2574 EMAIL CONTRACTOR'S STATE LIC NUMBER 935238 LICENSE CLASSIFICATION C36 VALUATION$ $5,000.00 SO FT L SQ FT APPLICANT'S SIGNATURE DATE 04/03/2017 DEPARTMENT DISTRIBUTION /-,I�j CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN V SMIP INVOICE PAID AMOUNT AMOUNT OCASH 0 CHECK# nCREDITCARD VISA/MC PLAN CHECK FEES PAIDAMOUNT OCASH OCHECK# OCREDITCARD VISA/MC OWNER BUILDER VERIFIED OYES O NO DL NUMBER NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Department 29714 HDun Rd. Menifee, CA 92586951-672.6777 www.cityo(meni/ee.us Inspection Request Line 951-246-6213 30331 r%ar,- N�,v;� NPR - ZIoA LA �258`i Jeor o.P��ICo. ofl City of Menitee (� O� 0O0 Building Dept APR D 4 2dit Receive` 1— z Ct I r_ 2� I -f-�.co f-4.V�cr5 DP( F7 ` 6 A R AG F -FRo 1UI- Y 1 t ;, m (n.m 'n -iIn d a°. ani v m •°bo .q dryw x 3 ^' Z N m O — pp •'b• 2 mf4 Z — n nd m m- E_ q O V N d � •� y F F' � N N (((YYY R S n ("� $ s^ o r o Y a 3 � � 1w W c.O CD ZZ CD N Y a. o d ew m ° � m s •W m O 9 'F` ar O t�+ C A A y W S 3 2 O D 9 C n 4 A d N O'F Y + N N 9 W n °C•t b• D m N p . 3 WA qo G � `� p m c ^ y N d � v � 3 •v„'i a w -�i r o :° m v w • _m $ � 9 n o o n m �^ �^ m m m w c 3 � m 2" m -Di N S N Q ` C 1^I. O Z Opp L '-G i •< w w � -J --yCC ^' y. w i � T 5 ' 4 ur m gym°. Z ir .- ..A '^ O m Z w y '�. 3 „ •'°. = s u 3 a ^ » r o m r2 ri w a7 3 rota .�. u < m .m rw y J � m u a — a u � c 3e ° EL • - n" o el = a a^c c of S r o m m -°�' °' c x- 3 d m w �'• p n 3 'o m � F m 3 0 " � aoaaWA " � A A y � N os ao m'2 n a FL m a n ^ e m w D o ^_ 42 m „ y N ` c m o pO p City Of Menifee 0 NaineN Building RPE Series Tankless Water Heaters Premium Condensing APR p y Zp» Specification Sheet Tankless Gas Water Heater {(� •Certified design according to ANSI Z21.10.3/CSA 4 ,e C e 10/ VI standards for both indoor or outdoor installations(initli optional Outdoor Vent Kit) •Compatible with 1/2'gas pipe up to a length of 24 R' (•sec Imtalladon Manual foraddldonal tnromuvon) •Compatible with 2"PVC Vent up to 60 R•'and ISO R•' using 3"PVC Vent Ctb-ed noelhows) n sl •Gas Input Ranges I NPE-150-120,000 to 10,000 BTUh —uP NPE-180-190,000 to 15,000 BTUh , NPE-210-180,000 to 19,900 BTUh im°.mam° - u oa." NPE-240-199,900 to 19,900 BTUh ® sesn-!'r, •-P°"eronmrr I •Hot Water Flow Rate Capacity(,based on 35T temperature rise) NPE-150-6.8 GPM NPE- 0-8.4 M Built-In Control Panel NPE-21210-10.1 10.1 GPM -' mom C wavillift �i NPE-240-11.2 GPM Sleek Design-Compatible with with DiagnosticsrL •Dual Primary and Secondary Stainless Steel Heat 2"PVC Vent and 1/2"Gas Pipe Exchangers for optimum efficiency and durability •Built-In Control Panel-allows adjustment of temperature settings and displays the operating status and error codes v f Indoor and Outdoor • CPQPIOW Technology-"A'models come Included with Venting Options built-in 0.5 gallon Buffer Tank and Recirculation Pump to provide rNoXa 00— maximum comfort t cooWm3 rNpe— oemeor 13 •INTELLIGENT Preheating-recognizes hot water usage patterns vem cap— to intelligently provide hot water when needed(optioml ror-r models) •Temperature Options-available temperature settings for Residential applications range from 98°F up to 140°F with high temperature Commercial mode capable of up to 182"F — B J •Ready-Link Multi-System-up to 16 units can be cascaded \v\T together for increased hot water production NomOnen VntOndoon Non-pima Vent mutchnr)wo •Reduced pressure loss for maximum hot water output mrart vent undoor) •Ease of Maintenance and Service-allows for quick removal and Q simple repairs to waterway components such as the pump,water adjustment Protection aiway valve ® ® petro4 O •Freeze Protection-maintains normal operation during freezing ambient temperatures down to-5°F(standard on all models) eeetjfa°® ae.nrno a •Uniform Energy Factor Ratings for NG and LP units NPE-180A/210A/240A-0.96 UEF (0.97 EF for Canada) NPE-150S-0.96 UEF(0.97 EF for Canada) NPE-1805/2105/2405-0.97 UEF (0.99 EF for Canada) •Compatible with Natural Gas(NG)and Propane(LPG)-' I—requires impllanon ofinduded FieldComersion Kit byaqualifiedgas servimr) job Name.- •Approved for Installations on Mobile/Manufactured Homes Location: •Certified by CSA,NSF 5,AHRI,AB1953 CA Low Lead,SCAQMD Engineer. (Rule 1146.27)ppe I-Complies with 14 ng/)ar20 ppm NOx@3%02) Wholesaler: •15-Year Heat Exchanger and S-Year Parts Warranty[Residential) Contractor: 8-Year Heat Exchanger and 3-Year Parts Warranty(Commercial).... Model No.: (••••see Navien Limitedwamanty) Submitted to: •Optional accessories are available(see below) leltletteceeaalhr NumbFasy Vehe Seta/47 COlyderuatr Nmtr•Ibar Keady-Wk rvntTmniMbnceps N8-]OOU (30009333A-Lead Free) (Gx0ean3n.Sigleunin CommunWvon Gble OutdeorvmtKn Extrnd"IR ke aMWYl flee9n D00097VA) 130a13581A-for Plae Covert rWc01l3N-Upm16Uaft (Gxxx000546) (30a10604A) (G%X%001319) (r W8736) (G%%%o013a3-Up to 14Unxs1 smavieN NPE Series Tankless Water Heaters Premium Condensing Specification Sheet Tankless Gas Water Heater Dimensions Specifications Item NPE-1505 NPE-180A I NPE-1805 NPE-210A I NPE-2105 NPE-240A I NPE-240S +soww iu_k .4,t Heat Natural Gas 181000- 15,000-150,00081U0f 19,900.180,000 BTU/H 19,900-199,900 BTU/H Capacity 120,000 (Input) Propane Gas BTU/H 15,000-150,000 BTU/H 19,900.180,000BN/H 19,9D0-199,900 BTUM r Efficiency UEF(faaoatn 0.96 0.96 0.97 0.96 0.97 a.96 0.97 '^ Radngs EF(Canada)a=,twatP) 0.97 0.97 0.99 0.97 10.99 0.97 1 0.99 sms,°a anin3..,� 35°F(19°gTem Rise 6.8GPM 8.4 GPM(32 Um) 1Ill GPM(38 Um) 112 GPM(42 Um) p (26 Urn) Flow Rate 45°F(25°[)Temp Rise GPM (20 (DHW) (20 UmI 6.5 GPM(25 Um) 7A GPM(30 Um) 8.7GPM(33Vm) <cnn.alPnsu. Q Ainnuke 0z• ° 3.2 GPM 4.3 GPM 4.2 GPM 5.0 GPM SI GPM 5.6 GPM 5.7 GPM 0L ustWsw,n 02• 67F(36°[)Temp Rise (12 Um) (16 Um) (16Um) (19Um) (20 Um) (21 Um) (22 Um) FIR lc�=h Dimensions 173'(W)x27A"(H)x 132'(D) Weight SS lbs 1 75 Its; 6106) 8216s 75 lbs 82lbs 75 lbs (25kg) (34kg) (3kg) (37k9) (34kg) (37 k91 (3491 Installation Type Indoor or Outdoor Wall-Hung Venting Type Forced Draft Direct Vent R Ignition Electronic Ignition Ek WaterPressure 15-15OP51 8 n Natural Gas Supply Pressure 35 in WC-10.5 in WC (from source) Propane Gas Supply Pressure 8In WC-131n WC (from source) Natural Gas Manifold Pressure -0g41nWC- .g.041n WC--O.B41n WC -0.05In WC--0.36 in WC -O.OS In WC--0.SB in WC (min-max) 'g 38mWC Propane Gas Manifold Pressure -0.041n WC- -0.05In WC--0.S0ln WC -0.10 in WC--0.66 in WC -0.101n WC--0.781nwc (min-max) -0.421nWC Minimum Flow Rate 0 GPM(0 Um)for"A"models/OS GPM(1.9 Um)for'S"models Cold Water inlet 3/4 in NFT ��--� Connection Hot Water Outlet 314 in NPT Sizes Gas Inlet 3/4In NPT • powerMain Supply 120V AC,60Hz Maximum Power.g®p Supply Mi P 200W(maz 2A),350W(max411)with external pump connected Consumption Casing Cold Rolled Carbon Steel Materials Heat Exchangers Primary Heat Exchanger.Stainless Steel 3r m xr � an.v SecondaryHeat Exchanger:Stainless Steel "sl'^nitl 2"or3'PVC,CPVC,Polypropylene �„n,ye„yn Exhaust 2"or3"Special Gas VentType BH(Claw 11,A/B/C) Q umw4te.nim Intake 0314• eeco-alnuomNer 0314• Venting 2'or3'PVC,CPVC,Polypmpylene Q Q Cddxateralet 0314• 2"or3"Spedal Gas Vent Type BH(Class II,A/B/q Q caonia 0314• Vent Clearances 0't0 combustibles Q Condema"Cud. 01n• Safety Flame Rod,APS,Ignition Operation Detector,WaterTemperature High Limit Switch,Exhaust Temperature High Limit Sensor, •u'�" Devices Power Surge Fuse Gas fired,mnkless,condensing,wall-mounted water heaters)shall be direct vent NPE Series models as manufactured by Navien,Inc.and are certified by CSA Group to the latest edition afANSI standard 221.1a3/CSA 43.Waterheater(s)shall have a 15 year limited Heat Exchanger warranty and 5-year limited Parts womanly(8-year Neat Exchanger and 3 yearParts for Commercial use)per Navien Limited Warranty.Unit(s)shall be designed to burn naturalgos and can be for use with propane when a Field Conversion Kit is installed.Water heater(s)shall have a nominalflow rate capadty of GPM/GPH at-°Frise with rated input of BTU/hr.Water heaters)shall be vented with 2'PVC/CPVC vent pipe at a distance not to exceed 60'(orequivalent)with each elbow equal to 8'ofpipe length or3"PVC/CPVCvent pipe at a distance af150'(ar equivalent)with each elbow equal to 5'of pipe length.Waterheater(s)is rated for150 PSI working water pressure and 300 PSI test pressure.Gas supply pressure shall be 3.5"to 10.5"WCfornaturaigas and 8.0"to 13.0"WCforpropane.Unit(s)shall have a steel case,dual stainless steel heat exchangers ern premixed burner, negative pressuregas valve,dual venturi,3/4"lnlelgas connection,3/4"brass inlet/outlet water connections,water holding capacity of 0.69allons far the NPE-150S,1.0 gallon for the NPE-180A model(0.79allom forNPE-180S model),IZgailons for the NPE-21OA/NPE-240A models(0.7 and 0.9 gallonsforNPE-210S and NPE-240S models respectively),and condensate collector.The NPE-150Smodel weighs 55lby the NPE-180A model weighs 75 lbs(NPE-180S weighs 67lbs),and the NPE-21OA/NPE-240A models weigh 82 lbs(NPE-210S and NPE-240S weigh 75 lbs).Units)shall Include featurmsuch as an adjusomentforinstallations at high elevation,temperature lockout;and temperature optionsfrom 98-120°Fin 1'FIntervals and 125-140-F in 57intemals.The units)shall include additional temperature options of 150-180-FIn 10°F Intervals, and 182'Ffor high temperature commercial applications.All NPE A"models shall include an internal circulation pump and 0.5ga/lon buffer tank The water heater(s)shall be controlled by an internal circuit board that monitors the inlet and outlet temperatures with Installed thermistors sensing and controlling flow rate to set point temperature with air-fuel ratio controls in order to maintain thermal combustion efficiency.Unt(s)shall Include safety featuressuch asffame sensorsystem,high gmitsensors overheat prevention device,freeze protection mode,and fan mororrotation detector.Multi-system(cascade)applications that require 2 to 16 units shall be installed by connecting the units using cable-only connections(Ready-Link).The water heater(s)exceeds the energy efficiency requirements ofASHRAE 90.1-2013 and is listed bySCAQMD rule 1146.2 Mpe I)forLow NOx that complies with 14 ng/j or 20 ppm NOx requirements @ 3%02. eNavfea reserves the right to changespecijimtions at any time without prior notice Navien,Inc. 20 Goodyear,Irvine,CA 92618 Ph:(949)420-0420 Fax:(949)420-0430 Www.Navien.com Rev.6/15