Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
PMT17-00662
City of Menifee Permit No.: PMT17-00662 29714 HAUN RD. Type: Residential Plumbing �ACCELA—> MENIFEE,CA 92586 MENIFEE Date Issued: 03/02/2017 PERMIT Site Address: 28670 AVENIDA MARBELLA, MENIFEE, Parcel Number: 364-093-003 CA 92584 Construction Cost: $5,000.00 Existing Use: Proposed Use: Description of REPLACE EXISTING WATER HEATER WITH TANKLESS WATER HEATER IN GARAGE Work: Owner Contractor CHAD SNYDER A R S AMERICAN RESIDENTIAL SERVICES OF 28670 AVENIDA MARBELLA CALIFORNIA INC MENIFEE, CA 92584 965 RIDGE LAKE BLVD SUITE 201 Applicant Phone:9012719700 ANDREW ALLEN License Number:765155 A R S INC DBA RESCUE ROOTER 965 RIDGE LAKE BLVD SUITE 201 MEMPHIS, CA 38120 Fee Description Qty Amount ISI Residential Water Heater 1 83.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 General Plan Maintenance Fee-Plumbing 1 4.15 $115.15 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Blog_Pennit Template.rpt Page 1 of 1 CITY OF MENIFEE LICENSED DECLARATION property who builds or improves thereon,and who contracts for the projects hereby,affirm under penalty of perjury that I am under provisions of with a licensed contractor(s)pursuant to the Contractors State License Law). Chapter9(commencing with section 7000)of Division 3 of the Business and D I am exempt from Iicensure under the Contractors State License Law for Professions Code and my license is in full force and effect. the following reason: License 0 of J License No By my signature below l acknowledge that,except for my personal residence Expires NI Signature in which l must have resided for at least one year prior to completion of improvements covered by this permit.I cannot legally sell a structure that I WORKER'S COMPENSATION DECIARATION have built as an owner-builder if it has not been constructed in its entirety by ❑I hereby affirm under penalty of perjury one of the following declarations:I licensed contractors.I understand that a copy of the applicable law,Section have and will maintain a certificate of consent of self-insure for workers 7044 of the Business and Professions Code,is available upon request when compensation,issued by the Director of Industrial Relations as provided for this application is submitted or at the following website: by Section 3700 of the Labor Code,for the performance of work for which ,y,leeinfa.ca.eov/calaw.html. this permit Is issued. Policy If Date rave and will maintain workers compensation insurance,as required by PROPERTY OWNER OR AUTHORIZED AGENT ection 3700 of the Labor Code,for the performance of the work for which ❑ mysignature below I certify to each of the following:)am the property this permit is issued.My workers compensation insurance carrier and policy caner or authorized to act on the property owners hehalL I have read this number are 1 application and the information I have provided is correct.I agree to comply II'1 �VC with all applicable city and coun nances and state laws relating to Carrier `� bWcstrutooth representatives of this city or county to Policy if (5b Expires tifi erty for inspection purposes. / (This section need not to be completed is the permit is f raIne-hundred Date f y dollars($100)or less PROPERTY OWNER OR AUTHORIZED AGENT �ertify that in the performance of the work for which this permit is issued, -ishallnotemolov any perso many manner sW to become subject to the CITY BUSINESS LICENSE# workers compensation sofC f nia,a ree that if l should become HAZARDOUS MATERIAL DECLARATION subject to the wor s con ion 'tuns of Section 3700 ofth Labor Cade,Ishall fo ith 6i -wit o rov'toos. Willthe applicant or future building occupant handleharardois material ora Date mixture containing a hazardous material equal to or greater that the Applicant amounts pe fled on the Hazardous Materials Information Guide? WARNING:FAILURE TO! WORKER'S COMPENSAT10 COVERAGE IS Dyes s No UNLAWFUL,AND SHALL SUBIECTAN EMPLOYER TO CRIMINAL PENALTIES Will the intended use of the building by the applicant orfuture building AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS($100,00D),IN occupant require a permit for the construction or modification from South ADDITION TO THE COST OF COMPENSATION,DAMAGES AS PROVIDED FOR Coast Air Quality Management District(SCAQMD)?See permitting checklist IN SECTION 3706 OF THE LABOR CODE,INTEREST,AND ATTORNEYS FEES forguidelines CONSTRUCTION LENDING AGENCY ❑Yes -aft, hereby affirm that under the penalty of perjury there is a construction - Will the proposed building or modified facility be within 1000 feet of the lending agency for the performance of the work which this permit is issued outer boundary of a school? (Section 3097 Civil Code) D Yes'/�No OWNER BUILDER DECLARATIONS I have read the Hazardou aterial Information Guideand the SCAQMD I hereby affirm under penalty of perjury thatlam exempt from the Permitting checklst. der aamy require under the State of Contractors License Law for the reason(s)indicated below by the California He it Safe de,Section and 25534 concerning hazardous eria rting. checkmark(s)I have placed next to the applicable Item(s)(Section 7031.5 �es o Business and Professions Code).Any city or county that requires a permit to Date construct,alter,improve,demolish or repair any structure,prior to its ROPERTY OWNER OR AUTHORIZED AGENT issuance,also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors State EPA RENOVATION,REPAIR AND PAINTING(RRPI License Law(Chapter 9(commencing with Section 7000)of Division 3 of the The EPA Renovation,Repair and Painting(RRP)Rule requires contactors Business and Professions Code)or that he or she is exempt from Iicensure receiving compensation for most work that disturbs paint in a pre-1978 and the basis for the alleged exemption.Any violation of Section 7031.5 by residence or childcare facility to be RRP-certified firms and comply with an Applicant for a permit subjects the applicant to a civil penalty of not more required practices.This includes rental property owners and property than($500). managers who do the paint-disturbing work themselves or through their D I,as owner of the property,or my employee with wages as their sole employees.For more information about EPA's Renovation Program visit: compensation,will do( )all of or( )portion of the work,and the structure is www.eua.eov/lead or contact the National Lead Information Center at not intended or offered for sale.(Section 7044,Business and Professions 1.800-424-LEAD(5323). Code;The Contractor's State License Law does not apply to an owner of a ❑An EPA Lead-Safe Certified Renovator will be responsible for this project property who,through employees'or personal effort,builds or improves the property provided that the improvements are not intended or offered for Certified Firm Name: sale.If,however,the building or improvement Is sold within one year of Firm Certification No.: completion,the Owner-Builder will have the burden of proving that It was not built or improved for the purpose of sale. ❑No EPA Lead-Safe Certified Firm is required for this project because: D 1,as owner of the property am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractors State License Law does not apply to an owner of a If your project does not comply with EPA RRP rule please fill out the RRP Acknowledgement. BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION - Menifee DATE 3"A'1 7 PERMIT/PLAN CHECK NUMBER TYPE: ❑COMMERCIAL ORESIDENTIAL [-]MULTI-FAMILY ❑MOBILEHOME ❑POOL/SPA [-]SIGN SUBTYPE: ❑ADDITION []ALTERATION []DEMOLITION [-]ELECTRICAL ❑MECHANICAL ❑NEW QPLUMBING ❑RE-ROOF-NUMBER OF SQUARES-City of M Itee DESCRIPTION OF WORK ( w r /1" tv(/-1 /74f Cff ty Dept. It, Ara rnoc rY��17 2017 d PROJECT ADDRESS &-70 lJh/ f NAl,-j llol ASSESSOR'S PARCEL NUMBER � '��-��� LOT TRACT ecee• .eel! OWNER NAME C�i1740/ �yt ADDRESS SaMOQ 7S'I PHONE g S7 95-& /0 3y EMAIL APPLICANT NAME nk&-) ///�-" /- ADDRESS /� 152-c) " G'vjgcH ."_ (e� PHONE 9S1 3q( 73 7 1( EMAIL CONTRACTOR'S NAME /gJ e5ctii,A-,Ae-' fi-9S OWNERBUILDER? ❑YEST!tNO BUSINESS NAME //JJ ADDRESS p,.5a0 11) 1-011 �2n Sd- /p-t".' e s74 eA- 11 '7 ? /PHONE ,3q/ 93 71 EMAIL CONTRACTOR'S STATE LIC NUMBER /l7sl� LICENSE CLASSIFICATION G3Cv VALUATION$ Ong / L SO FT APPLICANT'S SIGNATUREi� DATE 3/2 //7 DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN SMIP INVOICE PAID AMOUNT AMOUNT OCASH OCHECKH OCREDIT CARD VISA/MC PLAN CHECK FEES PAIDAMOUNT OCASH OCHECK# OCREDITCARD VISA/MC OWNER BUILDER VERIFIED OYES O NO DLNUMBER NOTARIZED LETTER O YES City of Menifee Building&Safety Department 29714 Noun Rd, Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 '^ O a O d g'• F m n %* D m MO n > my 2 m s � yAm cN mF mO (/7 ; T °. `" MF m e'*i w T X mo �. 3 w m �' 'D-I a' m Z a n'^ ,u� n ry i N v iu n 2 N 0 0) r D m2m rD r m m> a � � c � x `�. m 01 ^. m v � •c� d w o D •• Z A: � g � ymn � vo�i 000 ' o w w E '_" m .p1.• m 3 (Z m �-+ .31 3 -r'1 41 a m m o .� m m 1l c o m o -} mfry' m �" N ^' (1 =� 'm z -I 0 3 3 o m ' -f � O .< = c m m nD '� Z a m O n a < m F 3 d Z sk &' 3 m 3 ' -ni. m it 3 co a o g n .'N2 $ n im zi °° �n m c o Z < m p .^. EF s, .. 3M. m 3 Er n ' £ 3 M ^m mm m m D N o H d m ^ w o N@ < N N IJ m m N 6 V F v. = m s o m m o m O N ^ ' 2 fml O ; m W d E o n m o 3 N m n m , m ? � 'd m 5 m m o m x o m o o o a •2 m ao a s a 3 3 m d a r ti v i a T 'n N = n m n c n -00 m N Z 3 � a o. o n � � A Z � N � N � ❑ N N 3 0 m a A `mci. � 3 C1 N w C. d n �. •n m a 01 n = m F R S T u m N N o' o o f .�. 'o -• a w v < o m 3 m O o a 3 3 m m 'u d N i m m i m F 0 2. m S Q °, N a A (°8 D p m N m Q p o ' 3 a m n m = as iE m o o =T 0 D C 3 '^ n A n z p n 'y •1 a 3 3 ^ On N ] 3 N A W NF~+ O b M v of to A M T ] m a ,�, x iu ] ,°', m m m c °�' 2 3 m m ma' ]• •may ry T v of < � `� O a O D O y ..• � ] ] c v v » o m � A 'o S q. n O K, � •G O D D ] Ip N N N N .� ] •y. p ] o `n' g m n S @ El El •�' of ] S w n a 3 ct ^ d n i h n N d O 0 . ...,a •91. m ] 3 d o0 0 01 c 13 H m a _ c br w 3 0 p]y a m Op N pp • J C � � n lO n p H W v 1� m 0 FF Tan F n m a I .r m m N S — .ce oT N 0 I �Nav�eN NPE Series Tankless Water Heaters Premium Condensing Specification Sheet Tankless Gas Water Heater •Certified design according to ANSI Z21.10.3/CSA 4.3.2013 ,�, •n, standards for both indoor or outdoor Installations(with - optional Outdoor Vent Kit) •Compatible with 1/2"gas pipe up to a length of24 fP (*see lasellaean Manual for additional informadon) •Compatible with 2"PVC vent up to 60 ft**and ISO ft** �Ou using 3"PVC vent("with no elbows) •Gas Input Ranges NPE-150-120,000 to 18,000 BTUh oiagnercrs - UP NPE-180-150,000 to 15,000 BTUh �„re,m,,;,,, O S Dawn NPE-210-180,000 to 19,900 BTUh . NPE-240-199,900 to 19,900 BTUh ® Relet I y ,ORrorr •Hot Water Flow Rate Capacity(•hose Ion 3STtempamturerUe) NPE-150-6.8 GPM NPE-180-8.4 GPM NPE-210-10.1 GPM Built-In CantlolPanel r �'-'�Y NPE-240-11.2 GPM with Diagnostics Sleek Design-Compatible Catch •Dual Primary and Secondary Stainless Steel Heat 2"PVC Vent and 1/2w Gas Pipe Exchangers for optimum eMciency and durability •Built-in Central Panel-allows adjustment of temperature settings and displays the operating status and error codes f Indoor and Outdoor • ({popg(f@ufflOW Technology-"A"models come included with ruesuGP s Venting Options built-in 0.5 gallon Buffer Tank and Recirculation Pump to provide 7,�npn g— maximum Comfort _ ace cede., •INTELLIGENT Preheating-recognizes hot water usage patterns vemr,P— to intelligently provide hot water when needed(national m far's- odels) - •Temperature Options -available temperature settings for Residential applications range from 98"F up to 140•Fwith high temperature Commercial mode Capable of up to 182-F a •Ready-Link Multi-System-up to 16 units Can be cascaded together for increased hot water production Non-mrectVentOuhnal Non-DiaxWent(Outdopd •Reduced pressure loss for maximum hat water output Otrettvene0naaad •Ease of Maintenance and Service-allows for quick removal and simple repairs to waterway components such as the pump,water adjustment valve,and 2-way valve oss'oe •Freeze Protection-maintalm normal operation during freezing ® 01 ambient temperatures down to-5*F(standard on all models] ® oeene•td rU •Uniform Energy Factor Ratings for NG and LP units NPE-18OA/210A/24OA-0.96 UEF(0.97 EF for Canada) ' NPE-150S-0.96 UEF(0.97 EF for Canada) NPE-IBOS/270S/240S-0.97 UEF (0.99 EF for Canada) •Compatible with Natural Gas(NG)and Propane(LPG)... I•'•requlrezimtalladenoflncluded held Coneenlon pltbyaauallnedessseMserl job Name: •Approved for Installations on Mobile/Manufactured Homes Location: •Certified by CSA.NSF 5,AHRI,AB1953 CA Low Lead,SCAQMD Engineer: (Rule 1146.2 7),pe 1-Complies with 14r(q/)or20ppm NOx@3%02) INholesaler. •15-Year Heat Exchanger and 5-Year Parts Warranty(Residential) Contractor. 8-Year Heat Exchanger and 3-Year Parts Warranty(Commercial)**** Model No.: (••••see Nauien Limited Warranty) Submitted to: •Optional accessories are available(see below) o � L @ Remora CanemOer Plumb FasyValve5et a/47 Conderaate Neutrallmr Ready Dnk 3'VentTemiination Caps NR.MU (300ng3BA-Leadymel (OIXx0a137y-Single Unitl Communication Cable OutdoarVmt pit I External Pump Wire and WJl Fhnges p3X0001324-Upto6Urdu) O001p6ndAJ i (GgIX00l31R1 n0100057A) nNl25RIA-forP1pe Cneb) WaIX001335-UP to I6lMiu) (CilIXXOW54a I (GMa3R73B) emNavieN NPE Series Tankless Water Heaters Premium Condensing Specification Sheet Tankless Gas Water Heater Dimensions Specifications Item NPE-1505 NPE-180A NPE-1805 NPE-210A I NPE-210S NPE-240A NPE-240S u.ca,u wass.,a Heat Natural Gas 18,010- 15,000.15%OOOBTU/H 19,9M-180,0008IU/H 19,900.199,9008TU/H 3 Capacity 12000D (Input) Propane Gas BTU/H 15000-150,000BTU/H 19,900.180,ODOBTUM 19,900-199,9008N/H Efficiency UEFlmrue4lal 0.96 (196 097 0.96 0.97 096 0.97 Ratings EF(Canada)uwuGe.v) 097 097 099 0.97 0.99 0.97 0.99 rsms>.a oam.n 35°F(19'QTemp Rise 68 GPM &4 GPM(32 Lim) 10.1 GPM(38 Um) 111GPM(42Um) (26 Um) Flow Rare 45°F(25°QTemp Oise 53 GPM 65 GPM(25 Um) 7.8GPIADOUm) 8.7 GPM(33 Um) ronnens°nsue (DHW) (20 Um) Q Nrimahe aa' 67°Fp6°gTemp Rlse 32 GPM 43 GPM 4.2GPM S.OGPM 52GPM 5.6GPM 5.7 GPM �Ouwucaswm 0r (12Um) (16Urr0 (16Um) (19 Um) (20 Um) (21 Um) (22 Um) Dimensions 173'(W)x27.4'(H)x I3X(D) Weight 55lbs 75Ibs 67lbs 82lbs 75Ibs 82lbs 75Ibs (25kg) (34k9) (30kg) (37 kg) (34kg) (37kg) (34kg) Installation Type Indoor or Outdoor Wall-Hung Venting Type Forced Draft Direct Vent Ignition Electronic Ignition 2 h Water Pressure 15-150P51 9 ° Natural Gas Supply Pressure (horn source) 35 in WC-105 in WC Propane GzsSupply Pressure Bin WC-131nWC (homsource) ❑ Natural Gas Manifold Pressure -0.04inWC-(min-man) -038inWC -0D4inWC--0.B4ln WC -0gSinWC-.036in WC -0.05inWC--058in WC Propane Gas Manifold Pressure. -0.04inWC- (min-max) -0A2in WC -0.05 in WC--0501n WC -0.10 in WC•-0b6inWC -0.10InWC--0.78 in WC -- x --Minimum FloxRate -O GPM(0 Urn)for'Nmodelsd05 GPM(19Um)fer'S•models C01dWaterinlet 3/4 in NPT Connection Sizes Hot Water Outlet 3/4 in NPT Gazlnlet 3M in NPr Main Supply 120VAC,60Hz - -- - - - Power - - - - - -50PPly ----Maximum Parer-- 20OW(max 2Ay35OW(max4A)with externalPump,connected Comumption h -,mow ,Casing Cold Rolled Carbon Steel u sv v Maredals Heat Exchane grs Primary Hut Exchanger.Stainless5teel amw arx.y Secondary Heat Exchanger..Stainless Steel 2'or3'PVC,CPVC,Polypropylene c°°nesuonsu. Exhaust 2"or3'SpecialGazVentType BH(Class ILA/B/Q Q norware,aNes 014• Venting 2'or3'PVC,CPVC,Polypropylene Qi Rearwlnelrlxl 0314• Intake 2'or3'SpedalGazVentType BH(Clmll A/B/Q ©G.,Warerinkr 0314' ©Gm lNet Ova• 1 VentClearan I 0'to combustibles 0 comereaxouua 0112'- Safety Flameflod,APS,Ignition Operation DetectogWaterTemperature High UmitSwitch,ExhaustTempeature High Limit Sensor, Devices Power Surge Fuse Gas/fred,[ankles,condensing,wall-mounted water heater(s)shall be direct vent NPESerlw models as manufactured by Navien,Inc and are certlffed by CSA Group to the latesteditlan ofANSI standard Z21.10.3/CSA 4.3.Waterheater(s)shall have a 15 yearlimited Heat Exchanger warranty and S yearllmited Parts warmnty(8yearlieat Exchanger and3 yearPartsfor Commercial use)per Nowlin;Limited Warranty.Unit(s)shall be designed ro bum natumigas and can be foruse with propane when a Ffeld Conversion Kitis installed Waterheater(s)shall have a nominal)low rate mpacityof GPM/GPH at_°Frise with mtedinputof BTU/hc Water heater(s)shall be vented with 2'PVC/CPVCvenop1pe ata distance not to exceed 60'(orequivalent)with each elbow equal to 8'ofpipe length or3"PVC/CPVCventpipe at a distance of1SO'(arequivalent)with each elbow equal to 5'ofpipe length.Waterheater(s)Is rated for150 PSI working waterpressure and 300 PSI lestpressure.Gassupply pressure shall be3.5'ro 10S"WCfarnatumlgas and 8.0'ro 13.0'WCforpmpane Unil(s)shall have a steel cone dual stainlesssteel heat exchanger;eco premixed burner, negative pressuregas valve,dual venturi,3/4"Inletgas connection,3/4"brass fnleUoutlet water connections,waterholdinq capacity of0.6gallonsfor the NPE-150S 1.0 gallon far the NPE-180A model(0.7ga11ansfarNPE-180S model),12gallonsfor the NPE-210A/NPE-240A models(0.7 and 0.9gallonsforNPE-2105and NPE-24OSmodels respectively),and a condensate collector.The NPE-1SOS model weighs 55 ibs,the NPE-180A model weighs 75Ibs(NPE-180S weighs 67lbs),and the NPE-210A/NPE-240A models weigh 8Z lbs(NPE-210S and NPE-2405 weigh 75Ibs).Uni(s)shall include feamressuch as an adjusnnentfor iwtallatfons athigh elevation,temperature lockau4 and temperature options from 98-120°Fin 1°Fintervals and 1ZS-140°Fin 5°Fintervals The unft(s)shall include additional temperature options of1SO-180°Fin 30°Fintervals, and162°Fforhi h temperature commercial applications.Ali NPE A"modelsshall include an lntemal circulation pump and0.5gallan buffertank.The water heater(s)shall be controlled by an fntemal circuitboard that monitors the inlet and audet tempemtures with installed thermistors,sensing and controlling/low rate to set paint temperature with air fuel mdo controls in order to maintain thermal combustion effciency.Unit(s)shall Include safety featuressuch m flamesensorsystem,high limitsewom,overheat prevention device,freeze protection made,andfan motor rotatian detector.Muld-system(cascade)applications that require2 to 16 unitsshall be installed by connecting the units using cable-only connections(Ready-Unk).The waterheater(s)exceeds the energy efficiency requirements ofASHRAE 90.1-2013 and fslisted by SCAQMD rule 1146.2 (Type 1)forLow NOx that complies with 14 ng/j or20 ppm NOx requirements(d 396 02. 'Navien reserves the right to changespeciftcations atany time without prlornotice Navien,Inc. 20 Goodyear,Irvine,CA 92618 Ph:(949)420-0420 In;(949)420-0430 www.Navien.com Rev.6/i6