PMT17-00257 City of Menifee Permit No.: PMT17-00257
29714 HAUN RD.
�I-\CCEL/-> MENIFEE,CA 92586 Type: Residential Electrical
MENIFEE Date Issued:
D2/13/2017
PERMIT
Site Address: 30189 BRISTOL GATE LN, MENIFEE, CA Parcel Number: 364-370-003
92584 Construction Cost: $6,823.72
Existing Use: Proposed Use:
Description of SOLAR TR 30422-3 MARIPOSA MPC#PMT16-00910
Work: 9 MODULES,2.36KW
LOT 62
Owner Contractor
LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC
980 MONTECITO DR#302 25 ENTERPRISE
CORONA, CA 92879 ATTN GOREEN MUELLER
Applicant Phone:9493498269
JEREMIAH ACAYTURRI License Number. 728102
LENNAR HOMES OF CALIFORNIA INC
25 ENTERPRISE
ATTN GOREEN MUELLER
ALISO VIEJO, CA 92656
Fee Description Qtv Amount W
Solar, Residential or Small Commercial 1 252.00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 1.00
General Plan Maintenance Fee-Electrical 1 12.60
$293.60
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing builiding operations being carded on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bldg_Permit_Template.rpt Page 1 of 1
BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION
.. Menifee
DATE 01/27/2017 PERMIT/PLAN CHECK NUMBER V ��
TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILE HOME ❑POOL/SPA SIGN
SUBTYPE: ❑✓ ADDITION ❑ALTERATION [—]DEMOLITION ❑ELECTRICAL ❑MECHANICAL
[-]NEW ❑PLUMBING [IRE-ROOF-NUMBEROFSQUARES
DESCRIPTION OF WORK Solar Permit-Plan 1924-2.39kW/9 PCS
M a er ' PMT 6 oogin
PROJECT ADDRESS 30189 Bristol Gate Ln,Menifee,CA 92584
ASSESSOR'S PARCEL NUMBER 364-370.003 LOT 62 TRACT 30422-3
PROPERTY OWNER'S NAME Lerner Homes of California,Inc.
ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879
PHONE (951)817-3680 EMAIL jeremiah.acaylurri@lennar.com E
APPLICANT NAME Lerner Homes of California,Inc.
ADDRESS 980 Monlecito Dr.,suite 302,Corona,CA 92879
PHONE (951)817-3680 EMAIL jeremiah.acayluni@lennar.com
CONTRACTOR'S NAME Lennar Homes of California,Inc. OWNER BUILDER? ❑✓YES❑NO
BUSINESS NAME Lennar Homes of California,Inc.
ADDRESS 980 Montedto Dr.,suite 302,Corona,CA 92879
PHONE (951)817-3680 EMAIL jeremiah.acaylurri@lennar.com
CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B
VALUATION$ $6,328.72 - L SQ FT
APPLICANT'S SIGNATURE DATE 01/27/2017
DEPARTMENT DISTRIBUTION VV (/V CITY OF MENIFEE BUSINESS LICENSE NUMBER
BUILDING PLANNING ENGINEERING FIRE GREEN SMIP
AMOUNT
INVOICE -;5 PAID AMOUNT
✓•� G[ASH G CHECK R ()CREDIT CARD VISA/MC
PLAN CHECK FEES PAIDAMOUNT GCASH 0 CHECK R OCREDITCARO VISA/MC
OWNER BUILDER VERIFIED DYES G NO DLNUMBER NOTARIZED LETTER G YES G NO
City of Menifee Building&Safety Department 29714 Noun Rd.Menifee,CA 92586951-672-6777
www.cityefinenifee.us Inspection Request Line 951-246-6213
9
E
i
SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED
ITE11 1 OTY 1 MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE
SYSTEM SIZE 1 2.39 KW I LOCATIONS INDICATED BY THE ILLUSTRATION.
MODULE 1 9 PCS.1 HYUNDAI I HIS-S265RG(265W) BUYER:_ _----
INVERTER 1 9 FICS.1 ENPHASE I M215-60-21LL-522-I13
ROOF TYPE I CONCRETE TILE DATE:
i
SUB-AWAY INFORMATION
MOD OTY ARRAY#I 1 ARRAA#2 ARRAY 03 CITY F ME
TILT 23° NA'
AZIMUTH 270° NA NA°NA° _�j7 UIL ING P
° DATE:
City of Meng{Pe PLAN APPRI
Building Dept I
JAN 2 7 22I7 REVI WE
Receive
'Approv I of these 1
approval of,any viol
— — — regulati s and ordi
f jobsite u itil comple
i
i
e i
o �
i
I
V
+
1 ' ARRAY I 3'-0' I]'d'FLASHIhIG
•
' SOLADECK WIRE
TRANSITION BOX
0.QJOER ARRAY)
w
1 r
� 1
PV AC DISCONNECT
EXTERIOR-GARAGE
UTILITY METER&
J SERVICE
+ I MAIINSERVICE PANEL
L-- --
-—— —� (VERIFIED BY BUILERI
NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF
®Z
PLAN 1924 ELEVATION A REVERSE
ORIENTATION 4 LO #
ORIGINAL BY: JIM PARKS DATE:16.03.16
MARIPOSA LENNAR:
80 MONTECITO DRIVE.#302 REVIEWED BY:ARTHUR HICKS I DATE:16.03.17
AT THE LAKES 9
CORONA.CA 92879 REV.# BY GATE DESCRIPTION 1
®4 namasbc
SAtAt
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 810aftay Slr
INDIVIDUAL 30189 BRISTOL GATE LANE B Ider.CO M304
PLOT PLAN 1 VI6'=I'-D' MENIFEE.CA 303.44TMW
SYSTEM LAYOUT
MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS
ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC LIMIT DETAIL
LOCATION MENIFEE.CA INV.MAKE INVERTER SPEC ENPHASE
TEMP.AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INV.MODEL INVERTER SPEC M215-60-2LLSZZ-IG
TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 INV.MAX POWER,(WAC MAX) INVERTER SPEC WATTS(AC) 225
TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV.INPUT V.(VW MAX) INVERTER SPEC VOLTS(DG) 48
TEMP,DELTA LOW(TI TA) TMw-TESST °C -27 INV.OUTPUT V.(VAC NON) INVERTER SPEC VOLTS(AC) 240
MOD.MANUFACTURER MODULE SPEC HYUVDAI INV.OUTPUT FREOUENCY INVERTER SPEC HERTZ 60
MOD.PART NUMBER MODULE SPEC HIS-SZ65RG INV.OUTPUT CURRENT.IAC INVERTER SPEC AMPS(AC) 0.9
MOD.POWER STC(P) MOOILE SPEC WATTS(00 265 INV.PHASE OUANTITY INVERTER SPEC PHASE I [L'T�/
1400.POWER PTC MODULE SPEC WATTS 00 230 COMPLIANCE INVERTER SPEC 0.U41/IEEEI f L 1 '
MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS CDC) 31.30 INV.GROUNDING INVERTER SPEC ISOLATED
MOD.OPEN CCT.VOLTAGE(V00 MODULE SPEC VOLTS CDC) 3B.10 INV.OTY,MAX/BRANCH CCT. INV-Qvc OTY 9
MOD.COEFF.VOLT/TEMP(COEE) MODULE SPEC V/°C -0.114 BRANCH CCT.OUTPUT.IMAXOC (IAC'INV.OT"0 AMPS(AC) 8.10
MOD.MAX VOLTAGE(V...mco) (Wx a(TD°CDEF)) VOLTS(DC) 41.18 INV.QUANTITY.TOTAL INV.CITYi OTY 9
MOD,OPERATING CURRENT(IMF) MODULE SPEC AMPS(DC) 8.50 TOTAL SYSTEM OUTPUT,IMAXTB I(IAC•INV.OTYT) I AMPS(Ad 6.10
MOD.SHORT CCT.CURRENT(ISO) MODULE SPEC AMPS 00 9.00
MOD.MAXIMUM CURRENT(IMAX) (ISO° 1.25) AMPS(DC) 11.25 )
MIN.AMPACITY REO'D,PER NEC (IN"• 1.25) AMPS(oc) 14.06
SERIES FUSE RATING,MAX MODULE SPEC AMPS(DC) 15
ELECTRICAL EQUIPMENT SCHEDULE °
KEY CITY MANUFACTURER MODEL NOTES TRADE I,�.�,.I
1 9 HYUVDAI HIS-SZ65RG(26SW) PV MODULE SOLAR $shall otbeCM
2 9 ENPHASE M215-60-2LL-522-IG PVINVERTER SOLAR
3 1 RSTC I SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR in of an I provW0
4 1 CUTLER-HAMMER OG221URB PV AC DISCONNECT,NEMA 3R.240V,30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR 1[e5. Tt IS set Of80
5 1 TBD TBD IZOV DEDICATED RECEPTACUE FOR ENVOY PV DATA MONITOR SOLAR )
7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR
8 NOTE CUTLER-HAMMER TOO PV BRANCH CIRCUIT BREAKERS;1 X 15A-IP(ENVOY) SOLAR
9 NOTE CUTLER-HAMMER TBD PV BREAKER.I X ZDA-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 1
10 1 TBD TBD SERVICE PANEL,MIN. 125A BUS BLOR.ELEC.
II 1 TBD TRD UTILITY METER,IPH.120/Z40V.200A BLOR.ELEC.
12 TBD TBD GROUNDING ELECTRODE UER BLDR.ELEC.
CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS
1)CONDITION OF USE(CDUO: (AMPACITY•TEMP.DERATE°FILL DEBATE)VS.REO'D(114X) ITEM UNIT PANEL
2.)TERMINALS(TERM): AMPACITY AT TERMINALS. VS.REO'D,LIMAX°1.25) PANEL MI CUTLER-HAMMER
KEY SIZE CU/AL INSULATION CALC' A AC1TY W/0 TEMP. I FILL I RESULT REO'D OCO BUS RATING AMPS 200
TYPE DERATES DERATE DERATE IA) (A) USED(A) MAIN DISCONNECT AMPS 200
A =11 ,1COU 30 0.]b L0 22.80 8.10 ALLOWED PV PER NEC AMPS 40
TERM 25 25 10.13 20 PV OCPD DEVICE USED AMPS 20
B COU 40 09, 1.0 36.40 8.10TERN 35 35 10.13 20
C COU AV 0.91 1.0 1 36.40 1 0.10
TERM 35 1 35 1 10.13 20
CONDUCTOR SCHEDULE
KEY CONDUCTORS CWAL TYPE LOCATION TRADE
A -N12 ENGAGE CABLE,1-FbG.FREE 41R CU TC-ER ARRAY SOLAR -
B 3-N10.1-010 EGG I CU I NM-B(ROMEX) INTERIOR I SOLAR
C 3-k10.1410 EGL I CU I NM-B(ROMEX) I INTERIOR I SOLAR
0 CAT5E,ETHERNET CABLE I CU I CATSE I INTERIOR I SOLAR
5 fill
11
7 • o O5EENOTE 15I 10
O � 0
AYP I
0 0 O 0
IN
� I
I I I
ROOF 'EXTERIOR-GARAGE
ELECTRICAL DIAGRAM 2.39 KW
LOTS 62
MARIPOSA LENNAR: ORIGINA BY: JIM PARKS GATE:16.03.16
980 MONTECITO DRIVE.•302 REVIEWED BY:MTHUR HICKS DATE:16.03.17 ��
Ir
AT THE LAKES CORONA,CA 92579 REV.# BY DATE DESCRIPTION
�N namasb6
R,aF
DWG TITLE: PAGE R: SCALE: SITE LOCATION: 45718roRCwa,Street
INDIVIDUAL 30189 BRISTOL GATE LANE PLOT PLAN 2 NTS ----_.L0803M ELECTRICAL MENIFEE,CA 300.AA7.0000
i
STRUCTURAL NOTES:
SOLAR CONTRACTOR-
n ALL PV ROOF ATTACHMENTS WILL BE SPACEO ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C.
2)ALL FV ROOF ATTACHMENTS WILL BE STAGGERED BY NOW AMONGST THE ROOF FRAMING MEMBERS.TO MAXIMUM EXTENT POSSIBLE.
3)ROOF PENETRATION&ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT.
4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS.IT WILL BE FLASHED AND SEALED,
5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE.
6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION
MANUAL.VERSION 227.3.PUB 140113-ICC.JANUARY 2014. /�p�(1
])UNIRAC TOP CLAMPS REQUIRE A ONE INCH(P)SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A 14INIMUM OF TWO INCHES(27 BEYOND THE EDGE AR (V.I
OF THE PV ARRAY/SUB-ARRAY.
8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40%
ROOFING CONTRACTOR BE INSTALLED PER MANUF4CTURER'S SPECIFICATIONS.
-
D DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'.
2)26 GAUGE INTERLOCKING FLASHING'SIOEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION.IT SHALL BE
"ROVED PRIOR TO PV SYSTEM INSTALLATION.
3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(I')OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO
4)AREAS LNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE.
5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS.
6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE.BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO '
INSTALLATION.
to be a D1.
e federal
ed plans iv.
ELECTRICAL NOTES:
GENERAL-
O ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL).
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC.
3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC
WELD.
4)NONCURRENT CARRYING METAL PARTS SMALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE
MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINTIFINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED.
5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE.
6)ALL CONDUCTORS WILL HAVE A 90°C RATING TO ENSURE CODE COMPLIANCE.
SOLAR CONTRACTOR-
7)MODULE CERTIFICATIONS WILL INCLUDE U.170 .IEC61646,IEC61730.
W CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS.
9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS.
10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM.
IO MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE
ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER.
12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122.
13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS.
IW A PV AGGREGATION PMEL(SUB PANEL)WILL NOT BE INCLLM FOR SYSTEMS WITH ONE BRANCH CIRCUIT,
15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR,
SIGNAGE-
16)PV SYSTEMS SMALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES.
U)ALL SAFETY MARKING/PLACARDS SMALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS
IW MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT t'.
19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'.
BUILDER ELECTRICAL AND SOLAR CONTRACTORS-
20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER.
20 SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26.
LENNAR: ORIGINAL 0Y: JIM PARKS DATE:16.03.16
MARIPOSA REVIEWED BY: ARTNU HULKS DATE:16.03.17
AT THE LAKES 9ORONA, ECITODRIVE.B302
CORONA,C492BM flEV.t BY DATE DESCRIPTION i
9-ru namaste
DMA[
DWG TITLE: PAGE p: SCALE: SITE LOCATION:
INDIVIDUAL d371 mu.Bru CO B Si met
PLOT PLAN 3 NTS MENU BRISTOL GATE LANE BwNer,CO 80304
NOTES MENIFEE,CA OW.M],0300
CAUTION:
POWER TO THIS BUILDING IS SUPPLIED BY THE
UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS
ARE LOCATED AS SHOWN.
n�
o in the
SOLADECK WIRE
TRANSITION BOX
(UNDER ARRAY)
PV AC DISCONNECT
EXTERII R-GARAGE
UTILITY METER 8
\MAIN SERVICE PANEL
(VERIFIED BY BUILDER)
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
1-877-SLR-POWR
PV POWER SOURCE - AC SPECS
AC OPERATING VOLTAGE: 240 V
AC OPERATING CURRENT: 8.1 A
NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION
LENNAR: ORIGWAL BY: JIM PARKS DATE:16.03.16
MARIPOSA 980 MONTECITO DRIVE.#3O2 REVIEWED BY:ARTHUR HICKS DATE:16.O3.17
AT THE LAKES CORONA,CA 92879 REV.k BY DATE DESCRIPTION
�b namasGe
cove
DWG TITLE: PAGE 8: SCALE: SITE LOCATION:
INDIVIDUAL 9BT1Oer.CO8dway 3M
PLOT PLAN A NTS MENI ORIGTOL GATE LANE Boulder.CO80]O0
PLACARDS MENIFEE.CA ]O].AOT.WOD