PMT16-04355 City of Menifee Permit No.: PMT16-04355
29714 HAUN RD. Type: Residential Addition
<A-CCELA�' MENIFEE, CA92586
MENIFEE Date Issued: 1212212016
P E R M I T
Site Address: 28387 CIDER ST, MENIFEE, CA 92585 Parcel Number: 329-381-008
Construction Cost: $2,800.00
Existing Use; 1 &2 Family Residence Proposed Use:
Description of INSTALL 46'x 15.6 CITY STO PATIO COVER WITH 3 FANS
Work:
Owner Contractor
MIGUEL AGUILAR
28387 CIDER STREET
MENIFEE, CA 92585
Applicant License Number:
MIGUEL AGUILAR
28387 CIDER STREET
MENIFEE, CA 92585
Phone:9513233128
Fee Description MY, Amount($I
Receptacle,Switch,Outlet&Fixture 3 126.00
Building Permit Issuance 1 27.00
Deck/Patio,standard 1 83.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 1.00
General Plan Maintenance Fee-Building 1 4.15
General Plan Maintenance Fee-Electrical 1 6.30
$248.45
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other
ordinance of City of MenifLe.Except as othervrise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA.Bidg_Pemit-Template.rpt Page 1 of 1
CITY OF MENIFEE
LICENSED DECLARATION property who builds or improves thereon,and who contracts for the projects
I hereby affirm under penalty of perjury that I am under provisions of with a licensed contractor(s)pursuant to the Contractors State License Law).
Chapter9(commencing with section 7000)of Division 3 of the Business and o I am exempt from Hcensure under the Contractor's State License Law for
Professions Code and my license is in full force and effect. the following reason:
License Class License No. By my signature below I acknowledge that,except for my personal residence
Expires Signature in which I must have resid ed for at least one year prior to com pletion of
WORKER'S COMPENSATION DECLARATION improvements covered by this permit.I cannot legally sell a structure that I
have built as an owner-builder If It has not been constructed In its entirety by
o I hereby affirm under penalty of perjury one of the following declarations:I licensed contractors.I understand that a copy of the applicable law,Section
have and will maintain a certificate of consent of seffminsure forworkees 7D44 of the Business and Professions Code,Is available upon request when
compens�ation,issued by the Director of Industrial Relations as provided for this application is submitted or at the following website:
by Section 3700 of the�Labor Code,for the performance of work for which
this permit is issued. wwvl.leeinfo.ca.gov/calaw.litmi.
Policy# Date
ci I have and will maintain worker's compensation Insurance,as required by PROPERTY OWNER OR AUTHORIZED AGENT
section 3700 of the La bor Code,for the performance of the work for which ci By my signature below I certify to each of the following:I am the property
this permit is issued.My worker's compensation insurance carrier and policy owner or authorized to act on the property owner's behalf.I have read this
number are: application and the information I have provided is correct.I agree to comply
Carrier with all applicable city and county ordinances and state laws relating to
building construction.I authorize representatives of this city or county to
Policy# Expires en
,Ue above identified property for inspection purpose,s.
(This section need not to be completed is the permit is for one-hundred
dollars($100)or less -Date -?_6 -14C
PROPtRTY OWNER OR AUTHORIZED AGENT
ci I certify that In the performance of the work for which this permit is issued,
I shall not employ any persons in any manner so as to become subject to the CITY BUSINESS LICENSE#
worker's compensation laws of California,and agree that if I should become HAZARDOUS MATERIAL DECLARATION
subject to the worker's compensation provisions of Section 3700 of the Labor
Code,I shall forthwith comply With those provisions. Will the applicant or future building occupant handle hazardous material or a
Applicant Date mixture containing a hazardous material equal to or greater that the
amounts specified on the Hazardous Materials Information Guide?
WARNING:FAILURE TO SECURE WORKER'S COMPENSATION COVERAGE IS ci Yes o No
UNLAWFUL,AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES Will the Intended use of the building by the applicant or future building
AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS($100,000),IN
ADDITION TO THE COST OF COMPENSATION,DAMAGES AS PROVIDED FO occupant require a permit for the construction or modification from South
Coast Air Quality Management District(SCAQMD)7 See permitting checklist
IN SECTION 3706 OF THE LABOR CODE,INTEREST,AND ATTORNEYS FEES forguldellnes
CONSTRUCTION LENDING AGENCY o Yes o No
I hereby affirm that under the penalty of perjury there is a construction Will the proposed building or modified facility be within 3.000 feet of the
lending agency for the performance of the work which this permit is issued outer boundary of a school?
(Section 3097 Civil Code) a Yes o No
OWNER BUILDER DECLARATIONS I have read the Hazardous Material Information Guide and the SCAQMD
permitting checklist.I unders;tand my requirements under the State of
I hereby affirm under penalty of perjury that I am exempt from the California Health&Safety Code,Section 25505 and 25534 concerning
Contractor's License Law for the reason(s)indicated below by the hazardous material reporting.
checkmark(s)I have placed next to the applicable Item(s)(Section 7031.5
Business and Professions Codej.Any city or county that requires a permit to ciYes ci No
construct,alter,improve,demolish or repair any structure,prior to its Date
issuance,also requires the applicant for the permit to file a signed statement PROPERTY OWNER OR AUTHORIZED AGENT
that he or she is licensed pursuant to the provisions of the Contractoes State EPA RENOVATION6 REPAIR AND PAINTING MRP)
License Law(Chapter 9(commencing with Section 7000)of Division 3 of the The EPA Renovation,Repair and Painting RRP)Rule requires contractors
Business and Professions Code)or that he or she Is exempt from Rcensure receiving compensation for most work that disturbs paint in a pre-1979
and the basis for the alleged exemption.Any violation of Section 7031.5 by residence or childcare facility to be RRP-certified firms and comply with
an Applicant for a permit subjects the applicant to a civil penalty of not more
than($500). required practices.This includes rental property owners and property
managers who do the paint-disturbing work themselves or through their
ci 1,as owner of the property,or my employee with wages as their sole employees.For more information about EPA's Renovation Program visit:
compensation,will do( )all of or( )portion of the work,and the structure Is www.epa.goyllead or contact the National Lead Information Center at
not Intended or offered for sale.(Section 7044,Business and Professions 1-800-424-LEAD(5323).
Code;The Contractor's State License Law does not apply to an owner of a o An EPA Lead-Safe Certified Renovator will be responsible for this project
property who,through employees'or personal effort,builds or improves the
property provided that the improvements are not intended or offered for Certified Firm Name:
sale.If,however,the building or improvement Is sold within one year of Firm Certification No.:
completion,the Owner-Builder will have the burden of proving that it was
not built or improved for the purpose of sale. 0 No EPA Lea.d-Safie Certified Firm is required for this project because:
a 1,as owner of the property am exclusively contracting with licensed
contractors to construct the project(Section 7044,Business and Professions
Code:The Contractor's State License Law does not apply to an owner of a If your project does not comply with EPA RRP rule please fill out the RRP
Acknowledgement.
BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION
,�IwMenifee
A01b".6--
DATE /Z-Zt-/Z PERMIT/PLAN CHECK NUMBER Qt!�Kax
TYPE: 0 COMMERCIAL )d RESIDENTIAL 0 MULTI-FAMILY 0 MOBILE HOME 0 PCIOL/SPA "'SIGN
SUBTYPE: 0 ADDITION 0 ALTERATION 0 DEMOLITION 0 ELECTRICAL 0 MeMkIgA Safety Depi
)51NEW OPLUMBING 0 RE-ROOF-NUMBER OF SQUARES DEC 2 2 2016
DESCRIPTION OF WORK __&tLPImb fcr fW-o 419 4�' 45
Received
_!F�A 2 ikollpec- CP,
PROJECTADDRESS
ASSESSOWS PARCEL NUMBER 'b,'A- :35X- C04& LOT TRACT
OW NER NAME aT-6�0(2(_ N�kjlS-f'Q—
ADDRESS d%T CA I t
PHONE q 51 - EMAIL 'I)CIQ 1015 Q�,VMNA I I- -cc"
APPLICANTNAME ��ULPL, t4\tjmt,^(L
ADDRESS -?_R31A-j C,�'Def_ C,:�)T tkC-Aj k VJ7C-46 C,,Q, 0,
PHONE cldsk- 32.!)- EMAIL L05_e2
CONTRACTOR'S NAME OWNER BUILDER. YES ONO
BUSINESS NAME
ADDRESS
PHONE EMAIL
CONTRACTOR'S STATE LIC NUMBER LICENSE CLASSIFICATION
VALUATION SO FT L SO FT
DATE JZ
OTYSTAFFUSEONLY
DEPARTMENT DISTRIBUTION SMIP CITY OF MENIFEE BUSINESS LICENSE NUMBER
BUILDING PLANNING ENGINEERING FIRE GREEN
INVOICE PAID AMOUNT
AMOUNT � QY3-451 I CPA&LIS 0 CASH 0 CHECK# OCREDITCARD VISA/MC
PLAN CHECK FEES I PAID AMOUNT 0 CASH 0 CHECK# OCREDITCARD VISA/MC_
OWNER BUILDER VERIFIED OYES 0 NO DLNUMBER NOTARIZED LETTER 0 YES 0 NO
City of Menifee Building&Safety Department 29714 Houn Rd. Menifee, CA 92586 951-672-6777
www.cityofmenifee.us Inspection Request Line 951-246-6213
LEDGER & TRACK
INSPECIt0N-WGUfRFU
0
Ire
00
;," , 3; f4
City 0 nifee
Building &[SE fety Dept.
1!61 , ITY OF MENIFEE
DEC 2 ! 2016
b Q
C\ MAIIIIIIIIIIIIIIII .X: j UILDING AND SAFETY E EPA"ENT
f LAN APPROVAL 61-Rec 9 ved
qj 14,
Z�
fVIEWEDBY Wt?llk
DAT ::
*Approval.of these plans sh'all not b�c;nstruecl to be a permit for�or an
approval of,any violation of any proislons of the fuleral,state or city I
oi� proved plaft must be kept on le
regulations and ordinances. This set aP
��,JDWteuntd compfEtion.—
(------------
0
f
�SCILIDEILOCM1,1GItEQUIFtEDFOR �2 OR2X40�D.C.MIN.SPACING
ALL WUDPATIOC�RSW/MIN(W LATZICEOR Ve'NOMINALPIL�D M17llERSPACING� FSLOP15 WPMFCCMMIN.
16,1TOEMAILSTC)HEACI SEIETABLE'A' EX)GENAILPLYWOODW/W
OREQUALFFRAMI �EIUJLT-UPORIXILL�FiNG 6-1 O.C.MAN.G.
72M'==E�ERII
SIM�141-1210REQUAU
,—HEADER SPAN&:si�- SIMPSON(MEOUAL) 24"� HUWCANECtJPSe48-0.C.
MAX SEETAEILS MAX UZEIGM: SEE TABLE -0- &
0 �-�EACHSJDE O�IANC
WMA.�RU SOLIlS
I'll 1�cl. --------- - ORIMNAILS
CLEAFtAhlc� SEEFIRAMING
6'-&'MIN. VETAIU5I(PG.2) �RA�Elt SPAN SIZE SEE TA51-E"A"
sl�w MAX E)usnNGWOOD
-------------------------------------- STUD WALL
TYPICAL COLUMNIRAS9 USE
& eiv(ad
so.Pas 3-12"CO�
4X4 P� SIMPSON Ce
OREQUALW/S=/ _k...... SLAB(3MICRE
MIN SC�INAR
0 MFG SPECS.
4X4PoSI`
NC�ANDWODD:
�TINGSI�
simTAELE:-�
FRONTVIEW ------------------------------------- SID
TABLETTAII TABLE IT B IT TA13LE TTCTT TABLE TT D IT
RAFTER SPANS HEADER SIZE & SPANS FOOTING SIZE LEDGER
(DOUGLAS FIR#2OR BETTER) (DOUGLAS FIR#2 OR BETTER) BOLTING_
SIZE SPACING SPAN RAFTER HEADER BASED ON 1000 ALL LAG BOLTS
SPAN — P.S.F. SOIL BEARING SHALL HAVE 1/4"
SPAN SIZE PRESSURE. PRE-DRILLED
HOLES-csEE moTE 2)
2x4 1211 O.C. 91-101, 8'-0" MAX 4 X 6 181, SQ.x 12" DEEP
16" O.C. 81- 111, UPTO 10'-0" MAX 4 X 8 18"SQ.X 12" DEEP 3/8" DIA. X 5"
24" O.C. 7'-8" 12Y-0" 12'-0" MAX 4 x 10 18"SQ.X 12" DEEP_ LONGAT16" O.C.
32" O.C. '6'-3" AX 4x 12 18" SQ.X 12" DEEP STAGGERED
2X6 F:2" O.C. A* 15'-4" 12�-V' 81-011 MAX 4 x 8 24" SQ.X 12'1 DEEP (2) 3/8" DIA X 51'
16"O.C. 131-91, TO 101-01' MAX 4 x 10 24"SO.X 12" DEEP LONG AT 16"
94 L-'G-.C. 1 1--3 V -0" MAX 4x 12
*91-7" 141-011 MAX 4x 14 24"SQ.X 121' DEEP
32" O.C. 2 -01, 121 24"SQ.X 12" DEEP 11O.C.
2x8 12" O.C. 20--0"
16" O.C. 18'-2" NOTES:
1. TWO 2X MEMBERS MAY BE SUBSTITUTED FOR ONE 4X HORIZONTAL
24" O.C. 14'- 10" FRAMING MEMBER.
32" O.C. 12'-8" 2. LAG BOLTS MUST FULLY ENGAGE A WOOD STUD OR RIM JOIST AND BE
2x10 1211 O.C. 20--0" PROVIDED WITH APPROPRIATE WASHERS. LAG BOLTS SHALL BE LOCATED A
16" O.C. 20'-0" MINIMUMOF 1-1/2"FROM THE TOP OR BOTTOM OF THE LEDGER.
24"'O.C. 181- 111, 3. NOT DESIGNED TO BE ENCLOSED-ADDITIONAL ENGINEERING ANALYSIS WILL
32" O.C. 16'-2" BE REQUIRED IF ENCLOSED.
4x4 2411 O.C. lot-oll 4. SEE PAGE 2 OF 2 FOR CONSTRUCTION DETAILS.
32" O.C. 9T-3"
48" O.C. 7'-8" DISCLAIMER:
4x6 2411 O.C. 15'- 1 1 ALTERNATE PATIO DESIGNS MAY BE POSSIBLE WHEN"WaM6 E
ENGINEERED ANALYSIS. USE OF THIS CONVENTIONAL RD DESIG"I
32"0 C 13'-9" AT THE USER'S RISK AND CARRIES NO IMPLIED OR IN4wQikGF
ANDSAF :7Y
48" O.C. *1 V-3" AGAINST FAILURE OR DEFECTS. PLAN AP I PROVAL
4xE3 2411 O.C. 20'�0"
32" O.C. i WV-STERN RIVERSIDE COUNTY COOF UNIFORMITY PROGRAM
148" O.C. 14 -�l cny OR
III ' 0�0" —N
THIS SPACING AND SPAN BUILDING D AR
N�
IS FOR LATTICE PATIO E71 E!i_
PATIO COVE DARD
9- 'TRACK RFP
COVERINGSOV&
Lt- 3E Ons shiiii not h; con$trw
r%-riON REQUIRED -awl Will Of
(951)672-6777 29714 HAUN ROAq.MENfow."gMdeny pro, sions of
iNSPE%j I — reenatInn�,qd,,,j. —
FAX(951)679-38431724/2014 1 IFEE.DEr"'"'
VAt39qIbfa fappro%
KNEE BRACE DETAIL,AT END PO LEDGER ATTACHMENT
REQUIRED WHEN RAFTER SPAN EXCEEDS 12 M DETAIL
24' EMSTING
ROOF
—ENML
N
0 0 PLMOODAT6
'LM�ATM�� I
O.C.ATIE�� LAG
BOLTS
fROOF
S/'3.'N
LAG
'CLT�
M57ING
BR&CEDCONNE—ONS STU
U DS
RAFTER
APPROVED JOIS r
A A
U4 TAA HANGER ZXLEDGER
WIN., SECTION A-A
NORM
1.USEACONTINUOUS 2XI EDGER-SAMEDEPTH
AS RAFTER OR LARGER
OFn0N I OPTION 2.SEE TABLE*D-FOR BOLTING REQUIREMENTS
INVERTED HEADER DESIGN OPTION (LATEICE ONLY)
TWO 1/2"DIA.THRU-BOLTS
0 CW/WASHERS). PER -
CONNECTION AS SHOWN
0 FOR HEADERS OR RAFrERS-
0 TWO 2X MEMBERS MAY BE
SUBSTITUTED FOR ONE 4X
MEMBER. SEE TABLES"A"
"B"FOR SPAN LIMITS
NOTE: KNEE BRACING REQUIRED
WHEN RAFTER SPAN
EXCEEDS 12 FEET
2X FASCIA(OVERHANG) ATTACHMENT-LATTICE ONLY
OFrrlON I OP`rJONl 2
�4 RAFTERS OR PRE-FAB.ROOFTRUSSES
2X4 LEDGER W/20d NAILS OR Ile DIA.X 4" 2X6OR LARGER RAFTERS
LONG LAG BOLTS 032"D.C.
2X4 STRUT WA3)Bd TOENAILS SIMPSONA-35OR
R PR
4
,F *RO
DG R W
LONG
0 OFTR
/2W
LAG 80
U
N
S
A
4 STR T SES
LS
0
R
2
0"
4
C
O'A_X 4"
L
6 R RGE
SM
2X 0 LA
I P
RRA
0
IFTERS
(03 Bd NA NA_35 R
3
W/ TOE 1 5 S 0
: To LEDGER EOUAL ANCHOR
U
F FROM STRUTTO LEDGER EOUALANCHOR
IR
(2)1 6d NAILS IVI 2X FASCIA
A-35OREOUALANCHOR JAI APPROVED
2X FASCIA JOIST HANGER
APPROVEDJOIST HANGER
2X20R2X4
PATIO RAFTERS
PATIORAF1 IRS
SEETABLE"A- SEETABLEN'
T, , rF
AF _1,Sp 4
MAX PATIO RAFTER SPAN PA'noRAFrFRSPAN
LIMITE To 0 L CF
DTD 5
[`_OVMERHtANG ]JmITEamavoRLATnc 3a,MAX LIMT7EDT0B'FORLATnCE
'o "
COVER �_OVERHANG COVER
-NOTE:- VERIFY-STRUCTURAL SOUNDNESS OF ROOF WESTERN PJVERSIDF C0UbrrY CODE UNI aftxd�rxf_
RAFTERS FOR DECAY OR TERMITE DAMAGE, BUILDING DEpmtTmaTE_
AND REPLACE WITH LIKE MATERIALS AS
NEEDED, AFTER CONSULTATION WITH THE PATIO CC)vk
efUVX9b
le sw or cfty
BUILDING DEPARTMENT. (9
(951)672-6777 29714 HAUN RDA
FAX(951)679-3;;;7j__2/z4/2oj4 rwww.crtYOFMFNIFEE.US IFIAGE2OF21