PMT16-04089 City of Menifee Permit No. PMT16-04089 29714 HAUN RD. Type: Residential Electrical OCACCELA—> MENIFEE,CA 92586 MENIFEE Date Issued: 01/0912017 P E R M I T Site Address: 30225 SUTTON CT, MENIFEE,CA 92584 Parcel Number: 364-370-035 Construction Cost: $8,331.60 Existing Use: Proposed Use: Description of SOLAR TR30422-3 CAMELLIA Work: 12 MODULES,3.18 KW MASTERPLAN PMT14-02630 LOT 136 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR.STE 302 25 ENTERPRISE CORONA, CA 92879 ATTN GOREEN MUELLER Applicant Phone:9493498269 JEREMIAH ACAYTURRI License Number.728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO, CA 92656 Fee Description 91t Amount Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 2.00 General Plan Maintenance Fee-Efectrical 1 12.60 $294.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing bulliding operations being carded on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA BidgPermit Template.rpt Page 1 of 1 UILDING & SAFETY PERMIT/PLAN CHECK APPLICATION Menifee DATE PERMIT/PLAN CHECK NUMBER TYPE: [:I COMMERCIAL Fe]RESIDENTIAL [-]MULTI-FAMILY E]MOBILE HOME EIPOOL/SPA E]SIGN SUBTYPE: EADDITION E]ALTERATION [JDEMOLITION []ELECTRICAL [:]MECHANICAL [:]NEW []PLUMBING [:1 RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit-Plan 2785-3.18kW/12 PCS Master Solar PNIT M PMT14-02630 PROJEcTADDRESS 30225SuttonCt ASSESSOR'S PARCEL NUMBER '3(;q-3M—jf)3S7 LOT 136 TRACT 30422-3 PROPERTY OWNER'S NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302 PHONE (951)817-3680 EMAIL jeremiah.acayturd@lennar.com APPLICANTNAME Lennar Homes of California,Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.aGayturd@lennar.com CONTRACTOR'S NAME Lennar Homes of California,Inc. OWNERBUILDER? FvjYESF]N0 BUSINESSNAME Lennar Homes of California,Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.aG@yturri@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ $8,331.60 SQ FT L SO FT I I DATE 12/01/2016 CITY STAFF USE ONLY DEPARTMENT DISTRIBUTION v �11 y u�mtNIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE JWGR�EN 1 0 S7M lop I INVOICE 00440 1 PAIDAMOUNT OCASH OCHECK# OCREDITCARD VISA/MC AMOUNT PLAN CHECK FEES PAIDAMOUNT 0 CASH 0 CHECK# OCREDITCARD VISA/MC OWNER BUILDER VERIFIED OYES 0 NO DLNUMBER NOTARIZED LETTER 0 YES 0 NO City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777 www.cityafmenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE L YSTEM SIZE 3,180 KW LOCATIONS INDICATED BY THE ILLUSTRATION. r r MODULE 12PCS.1 HYUNDAI HiS-SZ65 G(265W) BUYER: 0 MENIFE INVERTER IZPCS.1 ENPHASE I M215-60- LL-S22-IG ROOF TYPE TILE W/COMPOSITE SHINGLE UNi ER ARRAY DATE: DING AND ! SUB-ARRAY INFORMATION ARRAY#1 ARRAY#2 1 AR Y#3 ;-:,AN APPOM, �L MOD OTY 12 NA NA BUYER- TILT 23- 1 14AD I NAo -L AZ�IMUTH270- I NA- I NA' DATE: REVIEWED City of Menifee Building Dept 'Approval of these plans sh, ;pproval of,any vviol don of DEC 13 20% regulations and ordli iances. jobsite until complel!on. Received 19'-9'ARRAY 20'-7'FLASHING F ———— ————--—— SOLADECK WIRE TRANSITION Box L_ (UNDER ARRAY) PV AD DISCONNECT EXTERIOR-GARAGE LI --------- bo UTILITY METER& MAIN SERVICE PANEL—__4 (VERIFIED BY BUILDER) L———————— NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF z PLAN 2785 ELEVATION B ORIENTATION 4 LOT#136 CAMELLIA AT LENNAR: ORIGINAL BY: ANGELA BURKE DATE: I 980 MONTECITO DRIVE.#302 REVIEWED B .KIM ABCOUWER DATEAI 10.16 THE LAKES CORONA.CA 92879 REV.# BY DATE DESCRIPTION Omarnast* DWG TITLE! PAGE#: SCALE: SITE LOCATION: SOLAA 4571 Bmaday SImet INDIVIDUAL 30225 SUTTON COURT BoW&r,CO 80334 PLOT PLAN 1 1/16'=V-0, MENIFEE,CA 301�7.0300 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE ICALC UNIT DETAIL LOCATION MENIFEE.CA INV.MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH(THAX) ASHRAE 2% cc 37 INV.MODEL INVERTER SPEC M215-60-2LL-SF2--IG TEMP.AMBIENT LOW(THIN) ASHRAE EXTR_MIN 'C -2 INV.MAX POWER,(WAC MAX) INVERTER SPEC WATTS(A0 225 TEMP,MODULE TEST(TTEST) MODULE SPEC C 25 INV. INPUT V,(Vm MAX) INVERTER SPEC VOLTSWC) ETY TEMP,DELTA LOW(TDELTA) THIN-T�sT C -27 INV.OUTPUT V.(VAC NOM) INVERTER SPEC VOLTS(A0 240 MOD. MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD. PART NUMBER MODULE SPEC HIS-S265RG INV.OUTPUT CURRENT.IAC INVERTER SPEC AMPS(AC) 0.9 MOD. POWER STC(P) MODULE SPEC WATTS(00 265 INV.PHASE QUANTITY INVERTER-SPEC PHASE I MOD, POWER PTC MODULE SPEC WATTS(00 238 COMPLIANCE INVERTER SPEC U-17411JEEE1547 MOD, OPERATING VOLTAGE(V4P) MODULE SPEC VOLTS 030 31,30 INV.GROUNDING INVERTER SPEC ;SOLATED MOD. OPEN CCT. VOLTAGE(Vac) MODULE SPEC VOLTS(00 38.10 INV.OTY,MAX I BRANCH CCT. INV.QTYBC OTY 2 MOD. COEFF. VOLT/TEMP(COEF) MODU_E SPEC WIC -0.114 BRANCH CCT-OUTPUT.IM�IZ (IAC-INV.QTYBC) I AMPS(AQ 110.80 MOD. MAX VOLTAGE(VMAXMOD) (VOC.(TD-COEF)) VOLTS(130 41.18 INV. QUANTITY,TOTAL I INV.OTYT I OTY I lz MOD. OPERATING CURRENT OMP) MODULE SPEC AMPS 06 8.50 TOTAL SYSTEM OUTPUT.IMAXTS I CIAC-INV.GTYT) I AMPS(AC) 110.80 MOD. SHORT CCT. CURRENT Osc) MODULE SPEC AMPS 00 9.00 MOD. MAXIMUM CURRENT(IMAX) 0SC-1.25) AMPS D,C) 11.25 MIN.AMPACITY REG'D.PER NEC (IMAX- 1.25) AMPS 00 14.06 iot be cons SERIES FUSE RATING,MAX MODULE SPEC AMPS(130 15 1 �p-ovision ELECTRICAL EQUIPMENT SCHEDULE s!et of ap KEY QTY MANUFACTURER MODEL NOTES TRADE 1 12 HYUNDAI HtS-S265RG(265W) PV MODULE SOLAR 2 12 ENPHASE M215-60-ZLL-S22-IG PVINVERTER SOLAR 3 1 RSTC/SOLADECK 0786-3RS PV ROOF JUNCTION BOX.NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,240V,30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR 6 1 TBD TOD IZOV DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET C014NECTION TO HOME NETWORK BOX SOLAR 8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS: I x 15A-IP(ENVOY) SOLAR 1 9 NOTE CUTLER-HAMMER TBD PV BREAKER,I x 2OA-2P.LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR §ERVICEWPEANEERL.,MIN.. 125A BUS R C! 1 U7ILI7Y T PW t H2 H 1 142 1 T YB Dp 120124OV.200A SLDR��E�L2 1 12 11 1 TBD I TOD I GROUNDING ELECTRODE LEER I BLDR.ELEC. CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS 1)CONDITION OF USE(CCU): (AMPACITY-TEMP. DERATE -FILL DERATE)vs.REO'D(IMAX) ITEM UNIT PANEL 2)TERMINALS(TERM): I AMPACITY AT TERMINALS.vs.REG'D.(IMAX- 1.25) PANEL HER. CUTLER-HAMMER_ KEY SIZE CUIAL INSULATION CALC. AMPACITY WO TEMP. FILL RESULT REO'D OCD BUS RATING AMPS 200 TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS ZOO A #12 CU I THWN-2 Cou I so 0.76 1.0 22.80 10.80 ALLOWED PV PER NEC AMPS 40 i i A 25 13.50 20 PV OCPD DEVICE USED AMFS_ #10 CU NM-13 Cou 1 1.0 36.40 10.80 I ERM 35 35 13.50 20 C #10 1 CU NM-B COU 40 0.91 1.0 36.40 10.80 1 TERM 35 35 13-50 NCONDUCTOR SCHEDULE KEY CONDUCTORS LO ION TRADE A 1-#12 ENGAGE CABLE,146G.FREE AIR FIRT I�TC-E;E �j ARCRATY SOLAR a 3-#10'1-#10 EGC I CU I NM-1 ERIOR SOLAR C 3-#10.1410 EGC I CU NM-B(ROMEX) I INTERIOR SOLAR c T5, THE DCAT5E,ETHERNET CABLE I CU CAT5E I INTERIOR SOLAR 7 a SEE NOTE 15 g)ISAIIP 4@ (D 0 20Al2P IL I N G jflfli[ flilflMR14141F , 4�f'-�- - G I I I G I 6 � — 1 6 1 TC ROOF ELECTRICAL DIAGRAM 3.IBOxW LOT#136 CAMELLIA AT LENNAR: ORIGINAL BY: ANGELA BURKE DATE:11-09-1 980 MONTECITO DRIVE,#302 REVIEWED BY:KIM ASCOUWER I DATE:11.10.16 THE LAKES CORONA.CA 92879 REV.# BY DATE DESCRIPTION amcisrifi DWG TITLE: PAGE #; SCALE: SITE LOCATION: 4571 Broad�y Stmet INDIVIDUAL 30225 SUTTON COURT Boul�r.CO 80304 PLOT PLAN 2 NTS MENIFEE,CA 3D3447D3GO ELECTRICAL I STRUCTURAL NOTES, SOLAR CONTRACTOR- 1)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'D.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS.TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. E DART 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FUSHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3*ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL.VERSION 227.3.PUB 140113-ICC.JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(10 SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 1jL 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. ROOFING CONTRACTOR- I 1)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3. R 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT 0')OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE.DOWN TO THE ROOF EAVE. PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. � 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. to be a 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED A80VE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. �ie federa 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE.BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. v�d plans i ELECTRICAL NOTES- GENERAL- 1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NECICEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING T14AT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINTIFINISH. PAINTIFINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646.IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122- 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING.OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED IZOV BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING I PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING I PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT�- 19)ALL WIRING/RACEWAYS/UUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE.'OR EQUIVALENT;WIRING/RACEWAYS SMALL BE MARKED EVERY 10. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY: ANGELA BURKE DATE:11.09� CAMELLIA AT LENNAR: REVIEWED BY:KIM ABCOUWER DATE:11.10.16 980 MONTECITO DRIVE.#3D2 THE LAKES CORONA.CA 92879 REV.# BY DATE DESCRIPTION mast;6 tit DWG TITLE: 7PAGE# SCALE: SITE LOCATION: �71�dway Stmet INDIVIDUAL 3 N 30225 SUTTON COURT B..Id.r.CO 803N PLOT PLAN 3 NTS MENIFEE,CA 303A47.OWD NOTES CAUTION: NT POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. Ae or city i 3e kept on the SOLADECK WIRE TRANSITION BOX---' (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE----,-,., UTILITY METER 8 MAIN SERVICE PANEL"--1 (VERIFIED BY BUILDER) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: 10.8 A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION CAMELLIA AT LENNAR: ORIGINAL BY: ANGELA BURKE I DATE:11.09.16 980 MONTECITO DRIVE,#302 REVIEWED BY:KIM ABCOUWER I DATE-IIAO,16 THE LAKES CORONA,CA 92879 REVm# BY DATE DESCRIPTION Vnamast;6 SOLAR DWO TITLE: PAGE#: I SCALE; SITE LOCATION: 4571 Broadway Street INDIVIDUAL 30225 SUTTON COURT BoLlder,CO 50� PLOT PLAN 4 NTS PLACARDS MENIFEE.CA 303.447.=