PMT16-04086 City of Menifee Permit No. PMT16-04086
29714 HAUN RD. Type: Residential Electrical
<A—cclELA—> MENIFEE, CA92586
MENIFEE Date Issued: 01109/2017
P E R M I T
Site Address: 29578 ARGYLE CIR,MENIFEE, CA 92584 Parcel Number: 364-370-032
Construction Cost: $6,943.00
Existing Use: Proposed Use:
Description of SOLAR TR30422-3 CAMELLIA
Work: 10 MODULES,2.65 KVV MASTERPLAN PMT14-02630
LOT 133
Owner Contractor
LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC
980 MONTECITO DR.STE 302 25 ENTERPRISE
CORONA,CA 92879 A7rN GOREEN MUELLER
Applicant Phone: 9493498269
JEREMIAH ACAYTURRI License Number.728102
LENNAR HOMES OF CALIFORNIA INC
25 ENTERPRISE
ATTIN GOREEN MUELLER
ALISO VIEJO,CA 92656
Fee Description ON Amount($1
Solar, Residential or Small Commercial 1 252.00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 1.00
General Plan Maintenance Fee-Electrical 1 12.60
$293.60
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing builiding operations being carried on thereunder when in Violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA,Bldg_Permit—TempIate.rpt Page 1 of 1
BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION
'I.-Menifee
DATE PERMIT/PLAN CHECK NUMBER
TYPE: E]COMMERCIAL E]RESIDENTIAL [:]MULTI-FAMILY []MOBILEHOME [—]POOL/SPA DSIGN
SUBTYPE: R]ADDITION []ALTERATION E]DEMOLITION [—]ELECTRICAL El MECHANICAL
FINEW DPLUMBING [:1 RE-ROOF-NUMBER OF SQUARES
DESCRIPTION OF WORK Solar Permit-Plan 2077-2.65kW/10 PCS
Master Solar PMT#:PMT14-02630
PROJECTADDRESS 29578 Argyle Circle
ASSESSOR'S PARCEL NUMBER :;(,-(4 - S70 — C) 32LoT 133 TRACT 30422-3
PROPERTY OWNER'S NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr.,Suite 302
PHONE (951)817-3680 EMAIL jeremiah.acayturri@Iennar.com
APPLICANTNAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879
PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com
CONTRACTOR'S NAME Lermar Homes of California,Inc. OWNERBUILDER? R]YESEIND
BUSINESSNAME Lennar Homes of California, Inc.
ADDRESS 980 Montec"ito Dr.,Suite 302,Corona,CA92879
PHONE (951)817-3680 EMAIL jeremiah.acaylurd@lennar.com
CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B
VALUATION$ $6,943.00 SQFT _---t-SQ FT
DATE 12/01/2016
APPLICANT'S SIGNATURE
CITYSTAFF USE ONLY
DEPARTMENT DISTRIBUTION 1.00 CITY OF MENIFEE BUSINESS LICENSE NUMBER
BUILDING PLANNING ENGINEERING FIRE I—GREEN F---NMIP
INVOICE PAIDAMOUNT
AMOUNT luels-'*D I I � OCASH 0CHECK# OCREDITCARD VISA/MC
PLAN CHECK FEES I PAIDAMOUNT I 1 0 CASH ()CHECK# OCREDITCARD nVISA/MC
OWNER BUILDER VERIFIED OYES (D No DLNUMBER NOTARIZEDLE17ER 0 YES (D NO
City of Menifee Building&Safety Department 29714 Houn Rd Menifee, CA 92586 951-672-6777
www.cityofmenifee.us Inspection Request Line 951-246-6213
SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED
ITEM OTY 1 MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE
EYSTEM SIZE 12.65OKW LOCATIONS INDICATED BY THE ILLUSTRATION.
MODULE 10 PCS.1 HYUNDAI I H,S-S265RG(265W, BUYER:
INVERTER I IOPCS.1 E14PHASE I M215-6D-ZLL-S22-IG ATY 01: ME
ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE:
SUB-ARRAY INFORMATION
ARRAY#1 ARRAY#2 1 ARRAY#3 BUILDIIIIIIS III
MOD QTY 10 1 NA iTA BUYER:
71_LT 23' 1 NA' I NA- DATE: '21 AN A PPRi
AZIMUTH 128c 1 NA� I NAc
city of menitee
130ding DePt REVIE%E4
'0 V
DEC, '1 3
'wrovalollieseph
approval of,ai y vioial
Rewv - regulations an I ordim
19-9"ARRAY
IT-I" 2D'-7'FLASHING jobsite until cc rpletio
f------ --- ---- -----------1
SOLADECK WIRE
TRANSITION BOX bO
(UNDER ARRAY)
PV AC DISCONNECT
__�EXTERIOR-GARAGE
UTILITY METER 8
]_�MAIN SERVICE PANEL
_j I All I L——— (VERIFIED BY BUILDER)
NOTE:DIMENSIONS ARE SHOW14 IN PLANE OF ROOF
N
PLAN 2077 ELEVATION B-REVERSE
ORIENTATION I LOT#133
LENNAR: ORIGINAL BY: ANGELA BURKE I DATE: .
CAMELLIA AT 980 MONTECITO DRIVE.#302 REVIEWED BY:KIM ABCOUWER I DATEAL10.16
THE LAKES CORONA.CA 92879 DATE DESCRIPTION
1�2 amasb6
DWG TITLE: PAGE#: SCALE: SITE LOCATION- 4571 Bro�way S��t
INDIVIDUAL 29578 ARGYLE CIRCLE Bou[�G GO 80304
PLOT PLAN 1 1/16'= 1'-0' MENIFEE,CA 303.447.0300
SYSTEM LAYOUT 1 7
MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS
ITEM NOTE/CALC UNIT DETAIL ITEM NOTEY CALC I UNIT DETAIL
LOCATION MENIFEE.CA INV.MAKE INVERTER SPEC— ENPHASE
TEMP.AMBIENT HIGH TMAX) ASHRAE 2% C 37 INV� MODEL INVERTER SPEC M215-60-2LL-S22-IG
TEMP.AMBIENT LOW THIN) ASHRAE EXTR.MIN 'C -2 INV.MAX POWER.(WAc MAX) INVERTER SPEC WATTS(AC) 225
TEMP.MODULE TEST(TTEST) MODULE SPEC C 25 INV. INPUT V.(Voc MAX) INVERTER SPEC VOLTS(m) 48
TEMP.DELTA LOW UDELTA) TMIN-TTETT C -27 INV.OUTPUT V.(VAC NOM) INVERTER SPEC VOLTS(AC) 240
MOD.MANUFACTURER MODULE SPEC HYUNDAI INV,OUTPUT FREQUENCY INVERTER SPEC HERTZ _E
MOD.PART NUMBER MODULE SPEC HiS-S265RG INV.OUTPUT CURRENT,IAC INVERTER SPEC AMPS(AC) 0.9
MOD.POWER STC(P) MODULE SPEC WATTS 00 265 INV.PHASE QUANTITY INVERTER SPEC PHASE I n SAF
MOD.POWER PTC MODULE SPEC WATTS(00 238 COMPLIANCE INVERTER SPEC UL1741/IEEE1547
MOD.OPERATING VOLTAGE VmP) MODULE SPEC VOLTS(DC) 31.30 INV.GROUNDING INVERTER SPEC ISOLATED
MOD.OPEN CCT.VOLTAGE(Voc) MODULE SPEC VOLTS(m) 38.10 INV.OTY.MAX/BRANCH CCT. 1 INV�QTYBC OTY
MOD.COEFF.VOLT/TEMP(COEF) MODULE SPEC VrC -0.114 BRANCH CCT. OUTPUT.IMAXBC I(lAC'lNV.GTY8C) i AMPS(AC) 1 9.00
MOD.MAX VOLTAGE VMAXM0D) (Voc�(TD'COEF)) VOLTS(110 41JB INV.QUANTITY.TOTAL INV.GTYT QTY 1 10
MOD.OPERATING CURRENT(IMP) MODULE SPEC AMPS(od B-50 TOTAL SYSTEM OUTPUT.IMAXTS (JAC-INV.QTYT) I AMPS(AC) 1 9.00
MOD.SHORT CCT. CURRENT OSO MODULE SPEC AMPS(oc) 9.00
MOD.MAXIMUM CURRENT OMAX) OSC- 1.25) AMPS(oc) 11.25
MIN.AMPACITY REO'D.PER NEC (IMAX- 1,25) AMPS D]C) 14.06
SERIES FUSE RATING.MAX MODULE SPEC AMPS(00 15
ELECTRICAL EQUIPMENT SCHEDULE
KEY QTY MANUFACTURER MODEL NOTES TRADE notb
1 10 HYUNDAI HIS-S2455RG(265W) PV MODULE SOLAR
2 10 ENPHASE M215-60-2LL-S22-IG I'VINVERTER SOLAR of any pro
3 1 RSTC/SOLADECK 0786-5R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR
4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT.NEMA SR,240V.30A SOLAR !s. This sei
5 1 ENPHASE ENVOY PV DATA MONITOR.120V SOLAR
6 1 TBD TBD IZOV DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR
7 1 TBO TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR
8 NOTE CUTLER-HAMMER TBO PV BRANCH CIRCUIT BREAKERS;I x 15A-IP(ENVOY) SOLAR
9 NOTE CUTLER-HAMMER TBD PV BREAKER,I x 20A-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR
12 TODD 2 �ERV'ICE FAML. 125A BUS 1 � 22 ��C�
1 1! 1 TB !T�B. UTL,FETER.IPH.120124OV,200A ELOHELEC
1 12 1 1 1 TBD TBD I GROUNDING ELECTRODE UFER
CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS
1)CONDITION OF USE(COLD: (AMPACITY- TEMP. DERATE I FILL DERATE)vs.REQ'D IMAX) ITEM UNIT PANEL
2)TERMINALS(TERM): AMPACITY AT TERMINALS.VL REO'D.OMAX- 1.25) PANEL MFR. CUTLER-HAMMER
INSULATION CALC. AMPACITY W/o TEMP. FILL RESULT REQ'D OCD BUS RATING AMPS 200
TYPE DERATES DERATE DERATE (A) (A) USED(A) 7FAIN DISCONNECT AMPS 200
THWN-2 COU 30 0.76 110 22.80 9.00 ALLOWED PV PER NEC AMPS 40
TERM 25 25 11.25 20 PV OCPD DEVICE USED AMPS ?n
NM-B COU 40 0.91 1.0 36.40 9.00
TERM 35 35 11.25 20
NM-B COU 40 0.91 1.0 3&40 9.00
TERM 35 35 11.25 20
CONDUCTOR SCHEDULE
�a 1 CONDUCTORS 1 CU/AL 1 TYPE 1 LOCATION TRADE
A _*12 ENGAGE CABLE.146G.FREE AIR I CU I TC-ER I ARRAY SOLAR
B I Z-#10.1-#10 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR
30 —
C 1 3-*10,1-#10 EGC I CU NM-B(ROMEX) I INTERIOR ISOLAR
D I CAT5E.ETHERNET CABLE I CU CAT5E I INTERIOR ISOLAR
SE!NOTE 15
ISAIIP
20A/2P
A �D
- -_ [_.. IN
I I IA G I
I I Ga 11
ROOF I EXTERID
ELECTRICAL DIAGRAM 2.650 KW
LOT#133
CAMELLIA AT LENNAR: ORIGINAL-BY: ANGELA BURKE DATE: . .
980 MONTECITO DRIVE,*302 REVIEWED BY:KIM ABCOUWER I DATE:Il.10.16
CORONA.CA 92879 REV.# BY DATE DESCRIPTION
THE LAKES mannasIA
I.,..
DING TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street
INDIVIDUAL 29578 ARGYLE CIRCLE Boulder,CO 80304
PLOT PLAN 2 NTS MENIFEE.CA 303.447.0300
ELECTRICAL
STRUCTURAL NOTES,
SOLAR CONTRACTOR-
1)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48*O.C.
2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS.TO MAXIMUM EXTENT POSSIBLE.
3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT-
4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED.
5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE.
6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION
MANUAL.VERSION 227.3.PUB 140113-ICC.JANUARY 2014.
7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH 00 SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND THE EDGE DEI
OF THE PV ARRAY I SUB-ARRAY.
8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40%
ROOFING CONTRACTOR-
1)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3".
2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL�TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE
APROVED PRIOR TO PV SYSTEM INSTALLATION.
3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT 0')OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE:To
BE INSTALLED PER MANUFACTUREFE'S SPECIFICATIONS. I
4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE.
5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS.
6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE.BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO
INSTALLATION.
of the
,Proved
ELECTRICAL NOTES-
GENERAL-
1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL).
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC.
3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC
WELD.
4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE
MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED.
5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE.
6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE.
SOLAR CONTRACTOR-
7)MODULE CERTIFICATIONS WILL INCLUDE U1.1703.IEC61646.IEC61730.
8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS.
9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS.
10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM.
11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE
ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER.
12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122.
IS)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS.
14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT.
15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR.
SIGNAGE-
16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES.
17)ALL SAFETY MARKING I PLACARDS SMALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS.
18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT�.
19)ALL WIRING/RACEWAYSIJUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE.'OR EQUIVALENT:WIRINGIRACEWAYS SHALL BE MARKED EVERY 10'.
BUILDER ELECTRICAL AND SOLAR CONTRACTORS-
20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER.
21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26.
ORIGINAL BY: ANGELA BURKE JDATE:11.
CAMELLIA AT LENNAR: REVIEWED gy:KIM ABCOUWER I DATE:11.10.16
980 MONTECITO DRIVE.#302
THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION
1�x namast;6
SOLAR
DING TITL�: PAGE#: SCALE: SITE LOCATION: 4571 Bma�ayStreel
INDIVIDUAL 29578 ARGYLE CIRCLE Bmider.CO 60304
PLOT PLAN 3 NTS MENIFEE,CA 301"TWOO
NOTES
CAUTION:
POWER TO THIS BUILDING IS SUPPLIED BY THE
UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS RT MENT
ARE LOCATED AS SHOWN.
k mow
.mi;'�,oran
0,0
'tctE 0"cify
st be kept on thl,
SOLADECK WIRE
—�TRANSITION BOX
(UNDER ARRAY)
PV AC DISCONNECT
EXTERIOR-GARAGE
UTILITY METER a
]—�MAIN SERVICE PANEL
(VERIFIED BY BUILDER)
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
1-877-SLR-POWR
PV POWER SOURCE - AC SPECS
AC OPERATING VOLTAGE: 240 V
AC OPERATING CURRENT: 9.0 A
NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION
CAMELLIA AT LENNAR: ORIGINAL BY: ANGELA BURKE DATE 11.09.16
980 MONTECITO DRIVE.#302 REVIEWED BY:KIM ABCOUWER I DATE:11.10.16
THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION masr6
tit SOLAR
DING TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway SVwt
INDIVIDUAL 29578 ARGYLE CIRCLE Boulder,CO 60304
PLOT PLAN 4 NITS MENIFEE.CA 303.447.0300
PLACARDS