PMT16-04084 City of Menifee Permit No.: PMT16-04084
29714 HAUN RD. Type: Residential Electrical
<A-CCELAJ' MENIFEE, CA 92586
MENIFEE Date Issued: 01/0912017
P E R M I T
Site Address: 29585 ARGYLE CIR, MENIFEE,CA 92584 parcel Number: 364-360-040
Construction Cost $7,650.40
Existing Use: Proposed Use:
Description of SOLAR TR30422-3 CAMELLIA
Work: 11 MODULIES,2.92 KW MASTERPLAN PMT14-02630
LOT 131
Owner Contractor
LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC
980 MONTECITO DR. STE 302 25 ENTERPRISE
CORONA,CA 92879 ATTN GOREEN MUELLER
Applicant Phone:9493498269
JEREMIAH ACAYTURRI License Number:728102
LENNAR HOMES OF CALIFORNIA INC
25 ENTERPRISE
ATTNI GOREEN MUELLER
ALISO VIEJO, CA 92656
Fee Description Qtv Amount 4)
Solar, Residential or Small Commercial 1 252.00
Building Permit Issuance 1 27.00
GREEN FEE 1.00
SMIP RESIDENTIAL 1.00
General Plan Maintenance Fee-Electrical 1 12.60
$293.60
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications orfrom preventing builicling operations being carried on thereunderwhen in violation ofthe Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA Bldg_Pemit Template.rpt Page 1 of 1
BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION
"'Menifee
1,
DATE PERMIT/PLAN CHECK NUMBER 'VyyfT I t)4*4
TYPE: F1 COMMERCIAL [E]RESIDENTIAL [:]MULTI-FAMILY F]MOBILE HOME F]POOL/SPA []SIGN
SUBTYPE: RIADDITION []ALTERATION []DEMOLITION F]EUEcTRICALF1 MECHANICAL
E]NEW OPLUMBING EIRE-ROOF-NUMBEROFSQUARES
DESCRIPTION OF WORK Solar Permit-Plan 2399-2.92kW/11 PGS
Master Solar PMT M PMT14-02630
PROJECTADDREss 29585 Argyle Circle
ASSESSOR'S PARCELNUMBER g(Sq - S60 -0(40 LOT 131 TRACT 30422-3
PROPERTY OWNER'S NAME Lennar Homes of California,Inc.
ADDRESS 980 Montecito Dr.,Suite 302
PHONE (951)817-3680 EMAIL jeremiah.acayturrI@Iennar.com
APPILICANTNAME LennarHomesof California,Inc.
ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA92879
PHONE (951)817-3680 EMAIL jeremiah.acayturti@lennar.com
CONTRACTOR'S NAME Lennar Homes of Calffibmia, Inc. OWNERBUILDER? RIYES[]NO
BILISINESSNAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA92879
PHONE (951)817-3680 EMAIL jeremiah.acaylurri@lennar.com
CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B
VALUATION$ $7,650.40 S FT
APPILICANT'S SIGNATURE DATE 12/01/2016
EMIL--
DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBS
BUILDING PLANNING ENGINEER-INS FIRE EEN SMIP
INVOICE PAID AMOUNT
AMOUNT 10CASH OCHECK# 0 CREDIT CARD VISA/MC
PLAN CHECK FEES PAIDAMOUNT 0 CASH 0 CHECK# 0 CREDIT CARD VISA/MC
OWNER BUILDER VERIFIED 0 YES 0 NO DL NUMBER NOTARIZED LETTER 0 YES 0 NO
City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777
www.cityafirnenifee.us Inspection Request Line 951-246-6213
SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED
ITEM ali MI MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE
EYSTEM SIZE 12.915 xW i — LOCATIONS INDICATED BY THE ILLUSTRATION.
MODULE 11 PCS.f HYUNDAI I HiS-S265RG(265W) BUYER:
INVERTER 1 11 PCS.1 ENPHASE I MI-IG
ROOF TYPE I TI 4DER ARRAY DATE:
SUB-ARRAY INFORMATION ..I 1 7 OF MENIFEE
ARR #1 1 ARRLY#2 1 AREAY#3 i"! I�kLDING AND AM
MOD QTY 14A NA BUYER:
71—LT 2S 1 NA' I NA- DATE: AN APPRO
AZIMUTH 180- NA' NA'
city of menifee
EWED
Building Dept 4
DEC 13 2016 'fk-:,:Hova1 of these plans shal not be
�.pproval of,any Itiolation of a ny prov
Received v�gulations and ordinances. I his set,
jasite until completion.
29'-B'ARRAY
30*-6"FLASHING T-9'
f
SOLADECK WIRE
TRANSITION BOX---'
(UNDER ARRAY)
PV AC DISCONNECT
EXTERIOR-rARAGE---,,.,
U"ILITY METER&
MAIN SERVICE PANEL-1-4 I I
(VERIFIED BY BUILDER)
NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF
PLAN 2399 ELEVATION A
ORIENTATION 3 LOT#131 N
CAMELLIA AT LENNAR: ORIGINAL BY: ANGELA BURKE I DATE:
980 MONTECITO DRIVE.#302 REVIEWED BY:KIM ABCOUWER I DA E:11.10.16
THE LAKES CORONA.CA 92879 REV.# BY DATE DESCRIPTION �Pnotnaswfi
30LAR
DWG TITLE: PAGE#; SCALE: SITE LOCATION: 4571 Bmd�ay Strae
INDIVIDUAL 29585 ARGYLE CIRCLE Boul�r,CO 80304
PLOT PLAN 1 1/16'=I'-0' MENIFEE,CA 303.447.0300
SYSTEM LAYOUT
MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS
ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL
LOCATION MENIFEE.CA INV.MAKE INVERTER SPEC ENPHASE
TEMP.AMBIENT HIGH(TMAX) ASHRAE 2% C 37 INV.MODEL INVERTER SPEC 1215-6�&L-SE-_IG
TEMP.AMBIENT LOW(TMlN) ASHRAE EXTR.MIN 'C -2 INV.MAX POWER.(WAC MAX) INVERTER SPEC WATTS(A0 225
TEMP.MODULE TEST(T�$T) MODULE SPEC c 25 INV. INPUT V.(VDC MAX) INVERTER SPEC VOLTS(DO 48
TEMP.DELTA LOW(TDELTA) THIN-TTEST C -27 INV.OUTPUT V.(VAC NON) INVERTER SPEC VOLTS(AC) 240
MOD. MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60
MOD.PART NUMBER MODULE SPEC HiS-S265RG INV.OUTPUT CURRENT.IAC INVERTER SPEC AMPS(AC) 0.9
MOD-POWER STC(P) MODULE SPEC WATTS(oc) 265 INV.PHASE QUANTITY INVERTER SPEC PHASE I DEI
MOD.POWER PTC MODULE SPEC WATTS(00 238 COMPLIANCE INVERTER SPEC UL]741/IEEE1547
MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(110 31.30 INV.GROUNDING RTER SPEC LATED
OTY�C llp
MOD.OPEN CCT.VOLTAGE(VOC) MODULE SPEC VOLTS(ac) 38.10 INV.OTY.MAX I BRANCH CCT. 1:NNE i OTY
MOD.COEFF. VOLTITEMP(COEF) MODULE SPEC V/-C -0.114 BRANCH CCT.OUTPUT,IMAMC I(IAC-INV.GTYBC) I AMPS(AQ 1 9.90
MOD.MAX VOLTAGE(VMAXMOD) (VQ:+(To-COEF)) VOLTS 030 41.18 INV.QUANTITY,TOTAL I INV.QTYT I OTY I ii
MOD.OPERATING CURRENT(IMP) MODULE SPEC AMPS(DC) 8.50 TOTAL SYSTEM OUTPUT, IMAXTS I(IAC-INV.QTYT) I AMPS(A0 1 9.90
MOD.SHORT CCT.CURRENT OSO MODULE SPEC AMPS 00 9.00
MOD.MAXIMUM CURRENT OMAX) (ISC* 1.25) AMPS 00 11.25
MIN.AMPACITY REO'D,PER NEC (IMAX- 1.25) AMPS(DC) 14.06
SERIES FUSE RATING.MAX MODULE SPEC AMPS(130 15
ELECTRICAL EQUIPMENT SCHEDULE
KEY QTY MANUFACTURER MODEL NOTES TRADE �trued
1 11 HYUNDAI HjS-S265RG(265W) PV MODULE SOLAR
2 11 ENPHASE M215-60-2LL-S22-IG PVINVERTER SOLAR �ns of 0
3 1 RSTC fSOLADECK 07a6-3R5 PV ROOF JUNCTION BOX.NEMA 3R SOLAR
4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,24OV,30A SOLAR Ipprove
5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR
6 1 TBD TED 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR
7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR
8 NOTE CUTLER-HAMMER TBID PV BRANCH CIRCUIT BREAKERS:I X ISA-IP(ENVOY) SOLAR
9 NOTE CUTLER-HAMMER TBD PV BREAKER.I x 20A-2P.LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR
SERVICE PANEL.MIN. 125A BUS BLDR ELEC
1 UTILITY�iETER,
P�
1 12, 1: TTB,,2) RE .120/24OV,200A
1 12 11 1 TED I TED I GROUNDING ELECTRODE LIFER I BLOR.ELEC.
CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS
1)CONDITION OF USE(COU): I (AMPACITY- TEMP. DERATE- FILL DERATE)�.REO'D(IMAX) ITEM UNIT PANEL
2)TERMINALS(TERM: I AMPACITY AT TERMINALS.VS.REO'D,(IMAX- 1.25) PANEL MFR. CUTLER-HAMMER
KEY SIZE CUIAL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REO'D OCD BUS RATING AMPS 200
TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200
A #12 CU THWN-2 COU 30 0.76 1.0 22.80 9.90 — ALLOWED PV PER NEC AMPS 40
TERM 25 25 12.3B 20 PV OCPD DEVICE USED AMPS 20
#10 CU NM-B COU 40 0.91 1.0 36.40 9.90
TERM 35 35 12.36 20
c— #10 CU NM-B COU 40 0.91 LO_ 36.40 9.90
TERM 35 35 12.38
CONDUCTO SCHEDULE
IRS CUIAL TYPE LOCATION TRADE
1�*12 NO GE CABLE,146G.FREE AIR -ER I ARRAY SOLAR 6
ENO CU TC
8 _#,O.1-#10 EGC CU NM-B(ROMEX) I INTERIOR SOLAR
C 6-#10. 1-#10 tGc CU NM-B(ROMEX) INTERIOR SOLAR
D CAT5E.ETHERNET CABLE CLI CAT5E INTERIOR SOLAR
SEE NOTE 15
150P
2/2f
31 L—IN
ROOF EXTERIOR-GARAGE
ELECTRICAU DIAGRAM 2.915 KW
LOT#131
LENNAR: ORIGINAL BY: ANGELA BURKE DATE: 1.09.1
CAMELLIA AT 980 MONTECITO DRIVE.#302 REVIEWED BY:KIM ABCOUWER DATE:11.10.16
THE LAKES CORONA.CA 92879 REV.# BY DATE DESCRIPTION Onamasri§
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Bmadway SImt
INDIVIDUAL 29585 ARGYLE CIRCLE Bouldw,CO 80304
PLOT PLAN 2 NTS 3D3.447.0300
ELECTRICAL MENIFEE,CA
STRUCTURAL NOTES,
SOLAR CONTRACTOR-
1)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48*D.C.
2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE.
3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT.
4)SULADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED.
5)PV ARRAY WILL BE A MINIMUM OF 3*ABOVE THE COMPOSITE SHINGLE ROOF SURFACE.
6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNiRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION
MANUAL.VERSION 227.3.PUB 140113-ICC.JANUARY 2014. RTM
7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH 0-)SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND THE EDGE
OF THE PV ARRAY I SUB-ARRAY.
8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'.
ROOFING CONTRACTOR-
1)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION To TILE)WILL BE A MINIMUM OF 3%
2)26 GAUGE INTERLOCKING FLASHING"SIDEWALL*TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SF16LL BE
APROVED PRIOR TO PV SYSTEM INSTALLATION. 40
3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(0 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE.DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO
BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS.
4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE-COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE.
S)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS.
6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE.BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO
INSTALLATION. ,a per
Qral,s
:ans mui
ELECTRICAL NOTES,
GENERAL-
1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL).
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC.
3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC
WELD.
4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE
MAY BE ELECTRICALLY INSUP ATED BECAUSE Of PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED.
5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE.
6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE.
SOLAR CONTRACTOR-
7)MODULE CERTIFICATIONS WILL INCLUDE UL1703.IEC61646.IEC61730.
8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS.
9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS.
10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM.
11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE
ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER.
12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250A22.
13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING.OR MANUFACTURER'S RECOMMENDATIONS.
14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT.
15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR.
SIGNAGE-
16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES.
17)ALL SAFETY MARKING I PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS.
18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT t.
19)ALL WIRINGIRACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE,'OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'.
BUILDER ELECTRICAL AND SOLAR CONTRACTORS-
20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER.
21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26.
LENNAR: ORIGINAL BY ANGELA BURKE JDATE:11.
CAMELLIA AT 980 MONTECITO DRIVE,#302 REVIEWED EY:KIM ABCOUWER I DATE:11.10.16
THE LAKES CORONA,CA 92879 DATE DESCRIPTION
Oamast;6
DWG TITLE: PAGE#; I SCALE- SITE LOCATION: - 4571 Bmad.ay Simet
INDIVIDUAL 29585 ARGYLE CIRCLE - S.ulde,.CO 803D4
PLOT PLAN 3 NTS MENIFEE,CA 303.447.03GO
NOTES 1 7
CAUTION: 4T
POWER TO THIS BUILDING IS SUPPLIED BY THE
UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS
ARE LOCATED AS SHOWN.
F��—
D
01E
ir cIty
kept on t e
SOLADECK WIRE
TRANSITION BOX--�
(UNDER ARRAY)
'V AC DISCONNECT—
EXTERIOR-GARAGE
UTILITY METER a
MAIN SERVICE PANEL
(VERIFIED BY BUILDER)Im
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
1-877-SLR-POWR
PV POWER SOURCE — AC SPECS
AC OPERATING VOLTAGE: 240 V
AC OPERATING CURRENT: 9.9 A
NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION
CAMELLIA AT LENNAR ORIGINAL BY: ANGELA BURKE I DATE:11.09.16
980 MONTECITO DRIVE,#302 REVIEWED By'-KIM ABCOUWER DATE.1.1.10.16
THE LAKES CORONA.CA 92679 REV.# BY DATE I DESCRIPTION
naM(]sb6
SOLAR
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Sireet
INDIVIDUAL 29585 ARGYLE CIRCLE BmIder,CO 80304
PLOT PLAN 4 NTS 303.447.0300
PLACARDS MENIFEE.CA