PMT16-04065 City of Menifee Permit No.: PMT16-04065
29714 HAUN RD. Type: Residential Electrical
<A-CCIE1-A> MENIFEE, CA 92586
MENIFEE Date Issued: 12/2212016
P E R M I T
Site Address: 27322 PROMINENCE RD, MENIFEE, CA Parcel Number: 335-463-026
92586 Construction Cost: $3,600.00
Existing Use: Proposed Use:
Description of INSTALL ROOF MOUNTED SOLAR SYSTEM,20 PANELS, 1 INVERTER, 5.8 <W
Work: REVISIONS APPROVED 4/27/17
Owner Contractor
ORVILLE PAYNE INNOVATIVE ELECTRIC INDUSTRIES INC
27322 PROMINENCE ROAD P 0 BOX 1399
MENIFEE, CA 92586 LOMPOC, CA 93438
Applicant Phone: 8057358500
HENRY BERMUDEZ License Number,9573134
INNOVATIVE ELECTRIC INDUSTRIES INC
P 0 BOX 1399
LOMPOC,CA 93438
Fee Description Div Amount($
Solar, Residential or Small Commercial 1 252.00
Building Permit Issuance 1 27.00
Inspections not specified 129 129.07
Reinspections 129 129.07
Additional Plan Review Building 129 129.07
Additional Plan Review Electrical 158 157.50
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 1.00
General Plan Maintenance Fee-Electrical 1 12.60
$838.31
The issuance of this permit shall not prevent the building official from thereafter requinng the correction of errors in the plans and
specifications or from preventing bulliding operations being carried an thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced Within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_61dg_Permit Template.rpt Page I of 1
CITY OF MENIFEE
LICENSED DECLARATION property who buildsor improves thereon,and who contracts forthe projects
I hereby affirm under penalty of perjury that I am under provisions of with a licensed contractor(s)pursuant to the Contractors State License Law).
Chapter9(commencing with section 7000)of Division 3 of the Business and 0 1 am exempt from licensure under the Contractor's State License Law for
Professions Code and my license is in full force and effect. the following reason:
LicenseClass C'J 0 License No. -7 3�A By my signature below I acknowledge that,except for my personal residence
Expires signature in which I must have resided for at least one year prior to completion of
improvements covered bythis permit.I cannot legallysell a structurethat I
WORKER'S COMPENSATION DECLARATION have built as an owner-builder if it has not been constructed in its entirety by
I
C
P
L'
E
W
I
h
I
r
I
c
x
ci I hereby affirm under penalty of perjury one of the following declarations:I licensed contractors.I understand that a copy of the applicable law,Section
(have and will maintain a certificate of consent of self-insure for worker's 7044 of the Business and Professions Code,is available upon request when
compensation,issued by the Director of Industrial Relations as provided for this application is submitted or at the following website:
by Section 3700 of the Labor Code,for the performance of work for which www.Ieginfci.ca.Rciv/caIaw.htmI.
this permit is issued.
Policy# Date
X PROPERTY OWNER OR AUTHORIZED AGENT
,6�1 have and will maintain worker's compensation insurance,as required by
section 3700 of the Labor Code,forthe performance of the work for which o By my signature below I certify to each of the following:I am the property
this permit is issued.My worker's compensation insurance carrier and policy owner or authorized to act on the property owner's behalf.I have read this
numberare: application and the information I have provided is correct.I agree to comply
with all applicable city and county ordinances and state laws relating to
Carrier building construction.I authorize representatives of this city or county to
Policy# enter the above identified property for Inspection purposes.
Expires 2:
(Th is section need not to be completed is the Ferro it is for one-hundred Date
dollars($1.00)or less PROPERTY OWNER OR AUTHORIZED AGENT
a I certify that In the performance of the work for which this permit is issued,
I shall not em Ploy any persons in any in anner so as to became so blect to the CITY BUSINESS LIOENSE#
workees compensation laws of California,and agree that if I should become HAZARDOUS MATERIAL DECLARATION
subject to the worker's compensation provisions of Section 3700 of the Labor
Code,I shall fo wit-h I%Mply with those provi.sions. Will the applicant or future building occupant handle hazardous material or a
I -:!S- Date I g a hazardous material equal to or greater that the
1AA_ no an the Hazardous Materials Information Guide?
mixtu '-a a�fied
Applicant_'� mores',p
.Y,
WARNING:FAILURE TO SECURE WORKER'S COMPENSATION COVERAGE IS o es No
UNLAWFUL,AND SHALL SU13JECTAN EMPLOYERTO CRIMINAL PENALTIES Will the intended use of the building by the applicant or future building
AND CIVILFINES UP TOONE HUNDRED THOUSAND DOLLARS($100,0001,IN occupant require a permit for the construction or modification from South
ADDITION TO THE COST OF COMPENSATION,DAMAGES AS PROVIDED FOR Coast Air Quality Management District(SCAQMD)?See permitting checklist
IN SECTION 3706 OF THE LABOR CODE,INTEREST,AND ATTORNEYS FEES forguidelines
CONSTRUCTION LENDING AGENC n Yes a/No
I hereby affirm that under the penalty of perjury there is a construction Will the proposed building or modified facility be within 1000 feet of the
lending agency for the performance of the work which this permit Is issued outer boundary of a school?
(Section 3097 Civil Code) n Yes dN0
OWNER BUILDER DECLARATIONS I have read the Hazardous Material Information Guide and the SCAQMD
permitting checklist.I understand my requirements under the state of
I hereby affirm under penalty of perjurythat I am exempt from the California Health&Safety Code,Section 25505 and 25534 concerning
Contractoes License Law for the reason(s)indicated below by the hazardous material reporting.
checkmark(s)I have placed next to the applicable item(s)(Section 7031.5 4es o No aA
Business and Professions Code).Any city or county that requires a permit to Date 0
construct,after,Improve,demolish or repair any structure,prior to its PROPERTY OWNER OR AUTHORIZED AGENT
issuance,also requires the applicant for the permit to file a signed statement
that he or she Is licensed pursuant to the provisions of the Contractor's State EPA RENOVATION,REPAIR AND PAINTING(RRPI
License Law(Chapter 9(commencing with Section 7000)of Division 3 of the The EPA Renovation,Repair and Painting(RRP)Rule requires contractiors
Business and Professions Code)or that he or she Is exempt from licensure receiving compensation for most work that disturbs paint in a pre-1978
and the basis for the alleged exemption.Any violation of Section 7031.5 by residence or childmre facility to be RRP-certlfied firms and comply with
an Applicant for a permit subjects the applicant to a civil penalty of not more required practices.This includes rental property owners and property
than($500), managers who do the paint-disturbing work themselves or through their
m 1,as owner of the property,or my employee with wages as their sole employees.For more information about EPA's Renovation Program visit:
compensation,will do I I all of or I I portion of the work,and the structure is www.epa.gov/fead or contact the National Lead Information Center at
not intended or offered for sale.(Section 7044,Business and Professions 1-800-424-LEAD(5323).
Code;The Contractor's State License Law does not apply to an owner of a ci An EPA Lead-Safe Certified Renovator will be responsible for this project
property who,through employees!or personal effort,builds or improves the
property provided that the improvements are not intended or offered for Certified Firm Name: V_C�d(
sale.If,however,the building or improvement is sold within one year of Firm Certification No.:
completion,the Owner-Builder will have the burden of proving that it was
not built or improved for the purpose of sale. o No EPA Lead-Safe Certified Firm is required for this project because:
in 1,as owner of the property am exclusively contracting with licensed
contractors to construct the project(Section 7044,Business and Professions
Code:The Contractor's State License Law does not apply to an owner of a If your projec(does not comply with EPA RRP rule please fill out the RRP
Acknowledgement.
WINSTON ENGINEERING LLC
city of Menitee
Fault Current Building & Safety Dept-
Project: PAYNE RESIDENCE APR 2 6 2017
To Whom It May Concern, RE)ceived
The total line to line fault current at the service panel for 27322 Prominence Road, Sun C CA
92586 is 29,006A. It is assumed 4/0 conductors were installed from the utility transformer. The
AC unit contributes 12A for a total of 48A. With the addition of the Solaredge SE600OA-US, the
line to line fault current is 29,03 IA. See load calculations below for the fault current due to the
utility transformer. Also provided are the feeder calculations for the home.
AVAILABLE-FA= C UE-TO-T-RANSF-0
Available Fault Current Calculation
Utility Fault Current amperes kVA
E [::::24�O
1=kVA x 1000=trans.FLA trans.FLA 0
E
Is.= trans.FLAx 100xPF PF
transformer Z z 1 1.50%
Ixa=arnpere short-caourt current RMS symmetrical. l"., 0 amperes
Point to Point Method single Phase 240/120
Length(distance) FEET L Coppff in Nonmetallic Raceway w
2xLxl (ASC) 1'.. 42.000
'I"factor= NxCxEL-N #conductors pw ase N ----
Phase conductor con:tant C Phase Conductor 4/0
Volt Line to Line EL-L 240 Volt
f 0.392
Neutral conductor constant c F-1 6.673 Neutral Conductor 4fO
Multiplier Volt Line to Nevinat EL-N 120 Volt
f 1.176
M= I e-� j
1 +f C., jJeQEi4-'lENiFEEm 0,718
Fault Current at Service EO CUD SA'WTY DOARTMENT
x M = fault current at terminal s�" 30,176 amperes
I.. x M = fault current at terminals of main disconnect L-N 28,958 amperes
REVIEWED BY 4�
�*DE
*Approval of these plans shall not he construed to be a permit for,or an
approval of,any violation of any provisions.of the federal,state or city
regulations and ordinances. This set of approved plans must be kept on the
Winston Engineering,LLC jobsite until completion,
29910 Munrieta Hot Springs Rd G502
Murrieta,CA 92563
951-708-6587
wn�v.WinslonEngincering]-LC.com page I of2
27322 PROMINENCE ROAD,SUN CITY CA 92586
LOAD CALCULATIONS(240/12OV)
SO Fr
1318
CIRCUIT SIZE
TYPE QUANTITY (A) NEC RATING (VA) TOTAL(VA)
SMALL APPLIANCES 2 20 15 Cu 3 30D0
GENERAL LIGHTING (3VA/SQF-1) 3954
ADDMONAL CIRCUITS
CURRENT RATING VOLTAGE
(A) (VI RATING(VA) QTY
WASHER 10 120 12DD
DRYER 6 120 720
AC UNIT(LARGEST MOTOR) 12 7,30 4129
GAREIAG3E DtSP0SAU----- -9--1 120 972
DISHWASHER 6.2 120 744
MICROWAVE 22.9 120 1550
REFRIGERATOR 6.5 120 780
FIRST 30DI)VA @ IDDV. 3DD0.0
3DD1VA-12DDD0VA@35% 3472.0
AC 125%LARGEST MOTOR 5160-0
TOTAL POWER(VA) 11632.0
TOTAL CURRENT(A) 48.5
Regards,
Anthony Winston III, P.E.
Owner/Electrical Engineer
Winston Engineering LLC
Anthonyn.q WinstonEngineeringLLC.com
951-708-6587
BUILDING AND SArETY DEPARTMENT
P L A N A P PIR OVA L
REVIEWED BY
C
DATE
"Approval of these plans shall not be construed to bea permit for,or an
approval of,any violation of any provisions.of the federal,state or city
regulations and ordinances, This set of approved plans must be kept on the
Winston Engineering,LLC jobsite until completion.
29910 Murrieta Hot Springs Rd G502
Murriet%CA 92563
951-708-6587
�.WinstonEngineeringl,LC.coni page 2 of 2