Loading...
PMT16-04061 City of Menifee Permit No.: PMT16-04061 29714 HAUN RD. Type: Residential Electrical -(��CCEU� MENIFEE, CA 92586 MENIFEE Date Issued: 01109/2017 P E R M I T Site Address: 28876 SKYLARK ST, MENIFEE, CA 92584 Parcel Number: 333-631-021 Construction Cost: $8.017.20 Existing Use: Proposed Use: Description of SOLAR TR 31582-1 MENIFEE HILLS Work: 12 MODULES, 3.18 KVV, MASTER PLAN PMT14-00706 LOT 31 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA,CA 92879 ATTN GOREEN MUELLER Applicant Phone:9493498269 JEREMIAH ACAYTURRI License Number.728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO, CA 92656 Fee Description Qtv Amount Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 2.00 General Plan Maintenance Fee-Electdcal 1 12.60 $294.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing building operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AkB]dg_Permit Template.rpt Page 1 of I BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION ""Menfee DATE PERMIT/PLAN CHECK NUMBER TYPE: []COMMERCIAL ERESIDENTIAL [—]MULTI-FAMILY []MOBILEHOME []POOL/SPA [—]SIGN SUBTYPE: ZADDITION []ALTERATION E]DEMOUTION DELEcTRICAL [:]MECHANICAL E]NEWE]PLUMBING FIRE-ROOF-NUMBEROFSQUARES DESCRIPTION OF WORK Solar Permit-Plan 2686 3.18kW/12PCS Master Solar PMT#: PMT14-00706 PROJECTADDRESS 28876 SkylarkStreet ASSESSOR'S PARCEL NUMBER 533-631- 02.1 LOT 31 TRACT 31582-1 PROPERTY OWNER'S NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com APPLICANT NAME Lerner Homes of Califamia,Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acaytur(i@lennar.com CONTRACTOR'S NAME Lennar Homes of California,Inc. OWNERBUILDER? RjYESF]NO BUSINESSNAME Lermar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL leremiah.acayturri@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ $8,017.20 S L SQ FT APPLICANT'S SIGNATURE �15���DDATE 12/01/2016 DEPARTMENT DISTRIBUTION (2C) OTY OF MENIFEE BUSINESS LICENSE NUMBER I�EEN SMIP BUILDING PLANNING ENGINEERING FIRE �G INVOICE AIDAMOUNT AMOUNT P OCASH 0CHECK# OCREDITCARD VISA/MC PLAN CHECK FEES PAIDAMOUNT 0 CASH 0 CHECK# OCREDITCARD VISA/MC OWNER BUILDER VERIFIED OYES 0 No DLNUMBER NOTARIZED LETTER 0 YES 0 NO City of Menifee Building&Safety Department 29714 Houn Rd. Menifee, CA 92586 951-672-6777 www.citltofmenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM 1 OTY MFR. 1 MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE F_ YSTEM SIZE 3.18 KW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 1 12 PCS. HYUNDAI I HIS-S265R6 11 W' I BUYER: F_�L_ INVERTER 1 12 PCS.1 ENPHASE 1 4215-60- LL_S22-IG i ROOF TYPE I TILE W1 COMPOSITE SHINGLE I DATE: SUB-ARRAY INFORMATION I ARRAY#1 ARRAY#2 AREAY#3 OF IVIEA MOD QTY 12 NA NA BUYER- LT 25' 1 NM RA' — DATE: iU1LD1Nij AF AZIMUTH 185' 1 NM MA' City of Menifee AN APPRO Building Dept M EWE D DEC 13 2016 11c *Approvalolthe ----- -- e plan ?Pproval of,any I iolatio regulations and o-dinan( jobsite until com;letjon. Ic" N�_�SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER 8 MAIN SERVICE PANEL L (VERIFIED By BUILDER) ,6, NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN 26B6 ELEVATION A REVERSE ORIENTATION 2 LO7#_TI MENIFEE HILLS LENRAR; ORIGINAL BY: JIM PARKS DAT :1 .2. 980 MONTECITO DRIVE.#302 REVIEWED BY:TOM FIDDES I DATE:15.12.02 CORONA,CA 92879 REV.# BY DATE DESCRIPTION �'Rmamast;6 SOLAR DWG TITLE: PAGE 9: SCALE: SITE LOCATION: 4571�a�ay SIML INDIVIDUAL 28876 SKYLARK STREET Boulder,CO 803D4 PLOT PLAN 1 1116"m 1'-0" MENIFEE,CA 303.44TOWD SYSTEM LAYOUT I MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE,CA INV.MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% C 37 INV.MODEL INVERTER SPEC MZ]5-60-2LL-SZZ-IG TEMP.AMBIENT LOW(THIN) ASHRAE EXTR.MIN 'C -2 INV.MAX POWER,(WAC MAX) INVERTER SPEC WATTS(AC) 225 TEMP.MODULE TEST(TTES1r) MODULE SPEC C 25 INV-INPUT V.(VDc MAX) INVERTER SPEC VOLTS 00 48 TEMP.DELTA LOW(TDELTA) TmIN-Till C -27 INV.OUTPUT V.(VAc NON) INVERTER SPEC VOLTS(AC) 240 MOD.MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD.PART NUMBER MODULE SPEC HiS-S265RG INV.OUTPUT CURRENT,IAC INVERTER SPEC AMPS(ACT 0,9 MOD. POWER STC(P) MODULE SPEC WATTS(cc) 265 INV,PHASE QUANTITY INVERTER SPEC PHASE I MOD. POWER PTC MODULE SPEC WATTS(cc) 238 COMPLIANCE INVERTER SPEC UL1741/[EEE1547 LRTER SPEC 1 j§OLATED MOD. OPERATING VOLTAGE(Vmp) MODULE SPEC VOLTS(cc) 31.30 INV.GROUNDING OTY.c 2 1 %FE1 MOD. OPEN CCT. VOLTAGE(Vac) MODULE SPEC VOLTS(DO 38.10 INV.OTY,MlCT. 1!NNV2 OTY MOD. COEFF.VOLT/TEMP(COEF) MODULE SPEC V/.0 -0.114 BRANCH CCT.OUTPUT.NAXIIC I (l4C-INV.QTY80 AMPS(AC) 110.130 _4 MOD. MAX VOLTAGE(VMl (Voc+ffl)'COU)) VOLTS(11C) 41.18 INV.QUANTITY.TOTAL I INV.QTYT OTY 112 It MOD. OPERATING CURRENT(imp) MODULE SPEC AMPS(m) IL50 TOTAL SYSTEM OUTPUT.IMAXTS I(IAC-INV.QTYT) AMPS(AC) 110.80 MOD. SHORT CCT.CURRENT(ISO MODULE SPEC AMPS(w) 9.00 MOD. MAXIMUM CURRENT Qlill Ill"1.25) AMPS(DQ 11.25 MIN.AMPACITY REO'D,PER NEC (IMAX-1.25) AMPS(130 14.06 SERIES FUSE RATING.MAX MODULE SPEC AMPS(cc) 1 15 ELECTRICAL EQUIPMENT SCHEDULE KEY QTY MANUFACTURER MODEL NOTES TRADE 1 12 HYUNDAI HiS-S265RG(265W) PV MODULE SOLAR 2 12 ENPHASE M215-60-21L-S22-IG PVINVERTER SOLAR A r Dt be ci 3 1 RSTC ISOLADECK 0786-3R5 TV ROOF JUNCTION BOX,NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT.NEMA 3R.24OV.30A SOLAR anj provisi 5 1 ENPHASE ENVOY PVF DATA MONITOR.120V SOLAR Thi;set of 6 1 TBD TBD 120V 0 SOLAR 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR 8 NOTE CUTLER-HAMMER TEID PV BRANCH CIRCUIT BREAKERS;I x ISAAP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER T8D PV BREAKER,I x 20A-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 12 122 1 Iy5D SMVICEi�PEATNEERL..HIN. 125A BUS R�E� I I Too Te 1 OTILIT P 1 2L2 5 L H,1201240V.2aDA BLD Et 1 12 1 1 1 TBD I TBD I GROUNDING ELECTRODE UFER I BLDR.ELEC. CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS 1)CONDITION OF USE(COM I CAMPACITY- TEMP.DERATE-FILL DERATE) vs.REO'D(IMAX) ITEM UNIT PANEL 2)TERMINALS(TERM: I AMPACITY AT TERMINALS. ys-.REO'D.(IMAX- 1.25) PANEL HER. CUTLER-MMMIER SIZE CUIAL INSULATION CALC. AMPACITY W/O TEMl FILL RESULT REGO OCD BUS RATING AMPS 200 KEY TYPE DERATES DERATE DERATE (A) M(A) USED(A) MAIN DISCONNECT AMPS 200 A *12 CU I THWN-2 COU 1 30 0.76 1.0 22.80 1 0.80 ALLOWED PV PER NEC AMPS 40 TERM 25 25 1 3.SO 20 PV OCPD DEVICE USED AMPS 20 #To Cu NM-8 COU 40 0.91 1.0 36.40 10.80 TERM 35 35 13.50 20 C #10 CU NM-B COU 40 0.91 A 36.40 10.80 13 50 20 TERM 35 35 13.50 20 CONDUCTOR SCHEDULE KEY 1 C NDUCTORS Cy I LO E _#12 ENGAGE CABLE,146G.FREE AIR EUA`L 1TCLER B 1 3-#10.I-fla EQC CU I I'll(ROMEX) 1 5 6 11 C 13410.1410 EGC I Cu I NM-B(ROMEX) I D I CATSE.ETHERNET CABLE I CU I CATSE I INTERIOR I SnI 'c' SEE NOTE 1511 15AIlP 4�D 20AIV 4 14 1 G T-10 ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 3.18 XW LOT#31 LENNAR; ORIGINAL BY: JIM PARKS I DATE: MENIFEE HILLS 980 MONTECITO DRIVE,#302 REVIEWED BY:TOM FIDDES I DATE:15.12.02 CORONA,CA 92879 REV.# BY DATE DESCRIPTION 1��Iftimast;d DWG TITLE: PAGE*: SCALE: SITE LOCATION: 4571 B�ay Steel INDIVIDUAL 28876 SKYLARK STREET Boulder,CO W304 PLOT PLAN 2 NTS 3M."7.0300 ELECTRICAL MENIFEE.CA STRUCTURAL NOTES- SOLAR CONTRACTOR- 1)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'D.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTE14T POSSIBLE. 33 ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3"ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL.VERSION 227.3.PUB 140113-ICC.JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(1*)SPACE BETWEEN PV MODULES. SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. IQ UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR MY RAIL LENGTH OF GREATER THAN 40% D ROOFING CONTRACTOR- 1)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT 01 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 6)BIRDSTOP WILL RE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE-BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. zo be a tie feder ad p:ans ELECTRICAL NOTES GENERAL- 0 ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NECICEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH_ PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61750. 0)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING.OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR FNPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS- IB)MARKING I PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT J'. 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED*PHOTOVOLTAIC POWER SOURCE,"OR EQUIVALENT:WIRINGIRACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. LENNAR: ORIGINAL BY: JIM PARKS DATE:15.12.01 MENIFEE HILLS 980 MONTECITO DRIVE,#302 REVIEWED BY: TOM FIDDES DATE:15.12.02 CORONA,CA 92879 REV.# BY DATE DESCRIPTION mast6 S.it �.L�� DWG TITLE: PAGE#; SCALE: SITE LOCATION: 4571 Bm�ay SVeet INDIVIDUAL 28876 SKYLARK STREET Boulder,CO,80304 PLOT PLAN 3 NTS MENIFEE.CA 301�17.0300 NOTES CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS 'IENT ARE LOCATED AS SHOWN. (e(o al�E Jr,oran ci�e or city be kept on tl e SOI-ADECK WIRE TRANSITION BOX DRIDER ARRAY) PV AC DISCONNECT _rEXTERIOR-GARAGE UTILITY METER a MAIN SERVICE PANEL CVERIFIED BY BUILDER) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: io.8 A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION MENIFEE HILLS LENNAR; ORIGINAL BY: JIM PARKS DATE:15.12.01 980 MONTECITO DRIVE.#302 REVIEWED BY:TOM FIDDES DATE:15.12.02 CORONA.CA 92879 REV.* BY DATE DESCRIPTION C�ejnamc=6 SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Bmadway Street INDIVIDUAL 28876 SKYLARK STREET Boulder,CO 803N PLOT PLAN A NITS MENIFEE.CA 301"7.030D PLACARDS