Loading...
PMT16-04059 City of Menifee Permit No.: PMT1 6-04059 29714 HAUN RD. Type: Residential Electrical <A-CCELA> MENIFEE, CA 92586 0 I.Y MENIFEE Date Issued: 01109/2017 P E R M I T Site Address: 29129 NECTARINE ST, MENIFEE, CA Parcel Number: 333-631-009 92584 Construction Cost; $8,017-20 Existing Use: Proposed Use: Description of SOLAR TR 31582-1 MENIFEE HILLS Work: 12 MODULES, 3.18 KW, MASTER PLAN PMT14-00706 LOT 9 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA,CA 92879 ATTN GOREEN MUELLER Applicant Phone:9493498269 JEREMIAH ACAYTURRI License Number.,728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO, CA 92656 Fee Description Qtv Amount Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 200 General Plan Maintenance Fee-Electrical 1 12.60 $294.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenoad within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA BidgPermit Template mt Page 1 of 1 2 arm a a H AA I I FRIM11 Off"an kv-11 2 MR -'-Men'fee DATE PERMIT/PLAN CHECK NUMBER R-11(y 04V9 TYPE: []COMMERCIAL HRESIDENTIAL [:]MULTI-FAMILY [:]MOBILEHOME [:]POOL/SPA [:]SIGN SUBTYPE: ZADDITION OALTERATION E]DEMOLITION []ELECTRICAL [:]MECHANICAL EINEW []PLUMBING FIRE-ROOF-NUMBEROFSCLUARES DESCRIPTION OF WORK Solar Permit-Plan 2686 3.18kW/12PCS Master Solar PMT#:PMT14-00706 PROJECTADDRESS 29129 Nectarine Street ASSESSOR'S PARCEL NUMBER -3,33—C-gl -00C? LOT 9 — TRACT 31582-1 PROPERTY OWNER'S NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302 PHONE (951)817-3680 EMAIL jeremlah.acaytur(i@lennar.com APPLICANTNAME Lannar Homes of California,Inc. ADDRESS 980 Montecito Dr..Suite 302,Corona,CA92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S NAME Lermar Homes of California, Inc. OWNERBUILDER? R]YESF]NO BUSINESSNAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOWS STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ $8,017.20 _IL50-FT APPLICANT'S SIGNATURE 12/01/2016 CITY STAFF USE ONLY DEPAKI'MEW 015TKIBUTIUN 6 FIRE ,400 7___]_C�1TY0F�MENIHE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEEMN GREEN SMIP INVOICE PAID AMOUNT AMOUNT *2q4-wo I I () CASH 0 CHECK# OCREDITCARD VISA/MC PLAN CHECK FEES PAID AMOUNT 0 CASH 0 CHECK# OCREDITCARD VISA/MC OWNER BUILDER VERIFIED OYES 0 NO DLNUMBER NOTARIZED LETTER 0 YES 0 NO City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-572-6777 www.cityofmenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM "Ti 1 MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE L Y-STEM SIZE 1 3.18,,w LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 12 PCS.j HYUNDAI I HIS-SZ65 G(265W) BUYER: INVERTER 1 12 PCS.1 ENPHASE 1 11215�0 LL-S22-IG ROOF TYPE I TILE W1 COMPOSITE SHINGLE UN ER ARRAY DATE: SUB-ARRAY INFORMATION I ARRAY#1 ARRAY#2 1 ARRAY#3 MD OTY 1 12 1 NA iTA cityot Menifee BUYER: TFLT 23' 1 NA- NA' AZIMUTH 1 228' 1 NA' NA' Building Dept DATE: MFIAR DEC 13 2016 DING AND APPRNA R e c le v eci 3--0' W,-10" F————— ————— —.-slo these �these lanssh ji�,f.any viol tion o ],Nons and ordi ances ;-.-,jntilcomple on. SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER& MAIN SERVICE PANEL (VERIFIED BY BUILDER) L I L———— NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN 2686 ELEVATION ,OTT ORIENTATION 3 ,9 MENIFEE HILLS LENNAR- ORIGINAL BY: JIM PARKS DA '15.12.01 980 MONTECITO DRIVE.#302 REVIEWED BY:TOM FIDDES I DATEA5.12.02 CORONA.CA 92879 REV.# BY - DATE DESCRIPTION Pmamast;6 SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 29129 NECTARINE STREET Boulder,CO 80304 PLOT PLAN 1 1/16'=V-O' MENIFEE.CA 31XI."TOWO SYSTEM LAYOUT I MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE ICALC UNIT DETAIL ITEM NOTE ICALC I UNIT DETAIL LOCATION MENIFEE.CA INV. MAKE INVERTER SPEC ENP14ASE TEMP.AMBIENT HIGH(TMAX) ASHRAE 2% C 37 INV. MODEL INVERTER SPEC M215-60-21-L-S22-IG TEMP,AMBIENT LOW(TMIN) ASHRAE EXTR.MIN 'C -2 INV. MAX POWER,(WAc MAX) INVERTER SPEC WATTS(AC) 225 TEMP,MODULE TEST(T�T) MODULE SPEC C 25 INV. INPUT V.(VDc MAX) INVERTER SPEC VOLTS(DO 48 TEMP.DELTA LOW(TOELTA) THIN-TTEST C -27 INV.OUTPUT V,(VAc NOM) INVERTER SPEC VOLTS(AC) 240 MOD. MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD.PART NUMBER MODULE SPEC HiS-S265RG INV.OUTPUT CURRENT. IAC INVERTER SPEC AMPS(AC) 0-9 MOD.POWER STC(P) MODULE SPEC WATTS(oc) 265 INV.PHASE QUANTITY INVERTER SPEC PHASE I MOD.POWER PTC MODULE SPEC WATTS(00 238 COMPLIANCE INVERTER SPEC UL1741/IEEE]547 MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS 00 31.30 INV. GROUNDING INVERTER SPEC I LA Y D1 MOD.OPEN CCT. VOLTAGE(VOO MODULE SPEC VOLTS 00 38.10 INV.QTY.MAX I BRANCH CCT. INV.QTYac QTY IZ MOD.COEFF. VOLTITEMP(COEF) MODULE SPEC vloc -0.114 BRANCH CCT.OUTPUT.IMAMC (lAC-INV.OTY8C 10.80 MOD.MAX VOLTAGE(VMAXKOD) (VOC+(TD*COEF)) VOLTS(M) 41.18 INV.QUANTITY.TOTAL I INV.OTYT I OTY I iz MOD.OPERATING CURRENT(Imp) MODULE SPEC AMPS(DC) 8.50 TOTAL SYSTEM OUTPUT,IMAXTS I (]Ac-INV.QTYT) I AMPS CAC) 110.80 MOD.SHORT CCT.CURRENT Osc) MODULE SPEC AMPS(oc) 9.00 MOD.MAXIMUM CURRENT OMAX) Osc- 1.25) AMPS(oc) 11.25 MIN.AMPACITY REO'D,PER NEC (IMAX- 1.25) AMPS(DO 14.06 SERIES FUSE RATING.MAX MODULE SPEC AMPS(00 15 ELECTRICAL EQUIPMENT SCHEDULE KEY QTY MANUFACTURER MODEL NOTES TRADE 1 12 HYUNDAI HiS-S265R-G(265W) PV MODULE SOLAR 2 12 ENPHASE M215-60-2LL-S22-IG PVINVERTER SOLAR 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT.NEMA 3R.24OV.30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR.120V SOLAR of app 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR_ SOLAR 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR 8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS;I x SA-lP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TED PV BREAKER,I x 2OA-2P.LOCATE AT OPPOSITE END OF BUS FROM MIN BREAKER SOUR 22 IERV,,IIE PANEL. -IN. 125A BUS 'C� 1,2 1 lT8D 'L FETER.FMPH.120/24OV,200A 1 BLD�R� �ELEC 12 1 TBD I TED GROUNDING ELECTRODE UFER CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS 1)CONDITION OF USE(COU): I (AMPACITY-TEMP.DERATE FILL DERATE) vs.REO'D(ImAx) ITEM LH41T PANEL 2)TERMINALS(TERM: I AMPACITY AT TERMINALS. REG-D.UMAX- 1.25) PANEL MFR. CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALC AMPACITY W/O TEMP. FILL RESULT REO'D OCD BUS RATING AMPS 200 TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 A #12 cu THWN-2 COU 30 Q76 1.0 22.80 10.80 ALLOWED PV PEF TERM 25 1 25 1350 0 PV OCPD DEVICE I'BED AMPS 1 20 B #10 CU NM-B COU 40 0.91 1.0 136.40 10.80 TERM SS 1 35 13.50 20 c #10 CU NM-8 COU 40 0�91 O.::::j 356 40 Oa$0 3 TERM 35 135 15.50 20 CONDUCTOR SCHEDULE KEY NDUCTORS 1 Sy/AL 1 TTY ER 1 TREADE _,12 CU C_E LOCATION S6 LN5AGL CAbl-t.I-#6G.FREE AIR ARRAY A 1 8 3-#10.1�10 EGC I Cu I NM-B(ROMEX) I INTERI C 3410.1410 EGC CU NM-B(ROMEX) I INTERIOR I SOLAR D CAT5E.ETHERNET CABLE CU CATSE I INTERIOR I SOLAR I SEE NOTE 15 4 IAII I�D P 20M � c � li � aTlaT flflC � 4141C 6 G N c 115 ROOF EXTERIOR-GAUGE ELECTRICAL DIAGRAM 3.18 KW LOT#9 MENIFEE HILLS LENNAR: ORIGINAL BY: JIM PARKS DATE: 980 MONTECITO DRIVE,#302 REVIEWED BY:TOM FIDDES I DATE:15.12.02 CORONA,CA 92879 REV.# BY DATE DESCRIPTION ll-�Vnamast6 DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 4�1 Bm�ay S�t INDIVIDUAL 29129 NECTARINE STREET Bouldff.CO 803D4 PLOT PLAN 2 NTS 3MA47.0300 ELECTRICAL MENIFEE.CA STRUCTURAL NOTES SOLAR CONTRACTOR- 1)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS.TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MW4UN_.VERSION 227.3,PUB 140113-ICC,JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(I')SPACE BETWEEN PV MODULES. SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21)BEYOND THE EDGE OF THE PV ARRAY I SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP HE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. mi ROOFING CONTRACTOR- 11 DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL*TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE SL APROVED PRIOR TO PV SYSTEM INSTALLATION. 6)PEFL-N-STICK BASE TO BE INSTALLED ONE FOOT 00 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK ME TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 9 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. I a pem ii deral,st I p ans mus ELECTRICAL NOTES, GENERAL- 1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NECICEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT MERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703.IEC61646.IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT Wl ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS- 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE A14D LOCAL CODES. 17)ALL SAFETY MARKING I PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING I PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT'*. 19)ALL WIRINGIRACEWAYSIJUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE,'OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMM-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL By JIM PARKS DATE:I . MENIFEE HILLS LENNAR: REVIEWED BY: TOM FID S DATE:15.12.02 980 MONTECITO DRIVE.#302 CORONA.CA 92879 REV.# BY DATE DESCRIPTION namast;6 SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Bmac�vay Sireet INDIVIDUAL 29129 NECTARINE STREET Bouldw,CO 803D4 PLOT PLAN 3 NTS MENIFEE.CA 303,447.03DO NOTES CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. rf?61 i) �r an -;ty t1w SOLAIDECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DMCONNECT EXTERIOR-GARAG _Tj UTILITY M' 1AI.SERVICE PAN'L-1 CVERIFIED BY BUILDER) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - Ac SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: 10.8 A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMAT] N MENIFEE HILLS LENNAR; ORIGINAL BY: JIM PARKS DATE:15.12.01 980 MONTECITO DRIVE,#302 REVIEWED BY:TOM FIDDES DATE:15.12.02 CORONA.CA 92879 REV.# BY DATE DESCRIPTION Conamcisbd SOLAR DWG TITLE- ]7PA'GE*: SCALE- SITE LOCATION: 4571 Broadway Street S INDIVIDUAL TS 29129 NECTARINE STREET Boulder.CO 80304 PLOT PLAN 4 FNTS MENIFEE,CA 303.447.0300 PLACARDS