PMT16-04058 City of Menifee Permit No.: PMT16-04058
29714 HAUN RD. Residential Electrical
<A-CCELA-> MENIFEE, CA 92586 Type:
MENIFEE Date Issued: 01/09/2017
P E R M I T
Site Address: 29117 NECTARINE ST, MENIFEE, CA Parcel Number: 333-631-008
92584 Construction Cost $9,353.40
Existing Use: Proposed Use:
Description of SOLAR TR 31582-1 MENIFEE HILLS
Work: 14 MODULES, 3.71 KW,MASTER PLAN PMT14-00706
LOTS
Owner Contractor
LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC
980 MONTECITO DR#302 25 ENTERPRISE
CORONA, CA 92879 ATTN GOREEN MUELLER
Applicant Phone:9493498269
JEREMIAH ACAYTURRI License Number.,728102
LENNAR HOMES OF CALIFORNIA INC
25 ENTERPRISE
ATTN GOREEN MUELLER
ALISID VIEJO, CA 92656
Fee Description Pti Amount($1
Solar, Residential or Small Commercial 1 252.00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 2.00
General Plan Maintenance Fee-Electrical 1 12.60
$294.60
The issuance of this permit shall not prevent the building official from thereafter requiring the comection of errors in the plans and
specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA BldgPermit-Template.rpt Page 1 of 1
BUILDIN & SAFETY PERM IT/PLAN CHECK APPLICATION
Menifee
DATE PERMIT/PLAN CHECK NUMBER
TYPE: F—ICOMMERCIAL ERESIDENTIAL []MULTI-FAMILY F]MOBILEHOME EIPOOL/SPA EISIGN
SUBTYPE: ZADDITION []ALTERATION F]DEMOUTION F]ELECTRICAL [:]MECHANICAL
E]NEW []PLUMBING El RE-ROOF-NUMBER OF SQUARES
DESCRIPTION OF WORK Solar Permit-Plan 2809 3.71kW/14PCS
Master Solar PMT#:PMT14-00706
PROJECTADDRESS 29117 Nectarine Street
ASSESSOR'S PARCEL NUMBER '(D<:60T 8 TRACT 31582-1
PROPERTY OWNER'S NAME Lermar Homes of California, Inc.
ADDRESS 980 Montecito Dr.,Suite 302
PHONE (951)817-36BO EMAIL jeremiah.acaytur�@lennar.com
APPLICANTNAME Lermar Homes of California,Inc.
ADDRESS 980 Montecito Dr.,Suite 302,Corona, CA 92879
PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com
CONTRACTOR'S NAME Lennar Homes of California,Inc. OWNER BUILDER? R]YESE]NO
BUSINESSNAME LennarHDmesof California,Inc,
ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879
PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com
CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B
VALUATION$ $9,353.40 SO FT �Fr
APPLICANT'S SIGNATURE '::��DATE 1DO-1/2016
DEPARTMENT DISTRIBUTION 1.00 t zoo CITY OF MENIFEE BUSINESS LICENSE NUMBER
BUILDING PLANNING ENGINEERHVG FIRE GREEN SMIP
INVOICE
AMOUNT *?AC4-40 PA�DAIMOUNT OCASH C)CHECK# OCREDITCARD VISA/MC
PLAN CHECK FEES PA D AMOUNT 0 CASH 0 CHECK# OCREDITCARD VISA/MC
OWNER BUILDER VERIFIED OYES 0 NO DL NUMBER NOTARIZED LETTER 0 YES C NO
City of Menifee Building&Safety Department 29714 Haun Rd.Menifee, CA 92586 951-572-6777
www.cityofirrIenifee.us Inspection Request Line 951-246-6213
SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED
ITEM 1 OTY HER. 1 MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE
EYSTEM SIZE 3.71 KW LOCATIONS INDICATED BY THE ILLUSTRATION.
MODULE I 14PCS. HYUNDAI I HIS-S265 G (265W) BUYER:
INVERTER 1 14 PCS.1 ENPHASE I MZIS-60- LL-SZ2-IG I
ROOF TYPE I TILE W/COMPOSITE SHINGLE UN ER ARRAY I DATE:
SUB-ARRAY INFORMATION A #2 1 ARRA #3 '1 OF ME Y1FE
ARRAY#1 1 ARR I Y
I A A BUYER:
�OD I . ING A
TFLTQTY 1 Z3 1 NA' I NA' DATE HIJILD ND
AZIMUTH 1 140- 1 NA' I NA-
�-AN APPROVA
City of Men!fee 'I'ZVIEWED BY6
Building Dept
DEC 13 nproval of these pf ins sha
,,pproval of,any viola ion of
n�gulations and ordin inces.
Recs--,,-,'�'1044AY1- liobsite until completii n.
91-B* 23-7'FLASHING
I 1 101
SOLADECK WIRE
TRANSITION BOX
(UNDER ARRAY)
j-
PV AC DISCONNECT
,-�EXTERIOR-GARAGE
UTILITY METER S
MAIN SERVICE PANEL
J� ---- - ---- (VERIFIED BY BUILDER)
NOTE:DIMENSIONS ARE SHOWN IN PUNE OF ROOF
PUN 2809 ELEVATION B REVERSE
ORIENTATION 5 LU10 6
MENIFEE HILLS LENNAR: ORIGINAL By'. JIM PARKS I DATE:15.12.01
980 MONTECITO DRIVE,#302 REVIEWED BY:TOM FIDDES I DATE:15.12.02
CORONA.CA 92879 REV.# BY DATE DESCRIPTION fpmamast;d
SOLAt
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Bmaftay Streei
INDIVIDUAL 29117 NECTARINE STREET Boulder,CO 803U
PLOT PLAN 1 1/16't V-0" MENIFEE,CA 1 303.447.0300
SYSTEM LAYOUT I
MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS
ITEM NOTE/CALC UNIT DETAIL ITEM NOTE I CAI-C I UNIT DETAIL
LOCATION MENIFEE.CA INV.MAKE INVERTER SPEC ENPHASE
TEMP.AMBIENT HIGH(TMAX) ASHRAE 2% 'C 37 INV.MODEL INVERTER SPEC M215-60-2LL-S22-IG
TEMP.AMBIENT LOW(TMIN) ASHRAE EXTR.MIN -C -2 INV.MAX POWER.IWAC MAX) INVERTER SPEC WATTS(AC) 225
TEMP.MODULE TEST(TTEST) MODULE SPEC c 25 INV. INPUT V.(Voc MAX) INVERTER SPEC VOLTS(DO 48
TEMP.DELTA LOW(TDELTA) TmIN-TTEST C -27 INV.OUTPUT V.(VAc NON) INVERTER SPEC VOLTS(AC) 240
MOD. MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60
MOD. PART NUMBER MODULE SPEC HiS-S265RG INV.OUTPUT CURRENT,IAC INVERTER SPEC AMPS(AC) 0,9
MOD. POWER STC(P) MODULE SPEC WATTS 00 265 INV.PHASE QUANTITY INVERTER SPEC PHASE I
MOD. POWER PTC MODULE SPEC WATTS 00 238 COMPLIANCE INVERTER SPEC UL[74111EEE15471-t! DI
MOD. OPERATING VOLTAGE(Vmp) MODULE SPEC VOLTS(DO 31.30 INV.GROUNDING INVERTER SPEC I
MOD. OPEN CCT.VOLTAGE(Voc) MODULE SPEC VOLTS 00 38.10 INV.QTY,MAX/BRANCH CCT. 1 INV.QTYBC QTY 14
MOD. COEFF.VOLTITEMP(COEF) MODULE SPEC V/-C -0.114 BRANCH CCT.OUTPUT.IMAXBC I (IAC*INV.QTYB0 AMPS(AC) 12-60
MOQ MAX VOLTAGE(VMAXM0D) (VOC�(TD*COEF)) VOLTS(oc) 4I.IB INV.QUANTITY,TOTAL I INV. OTY 14
MOD. OPERATING CURRENT(imp) MODULE SPEC AMPS 00 8.50 TOTAL SYSTEM OUTPUT.MAXTS CIAC fT) MPq""') 1 12.60
MOD. SHORT CCT.CURRENT(Isc) MODULE SPEC AMPS(00 9.00
MOD. MAXIMUM CURRENT DMAX) OSC' 1.25) AMPS(00 11.25 k�
MIN.AMPACITY REO'D.PER NEC (IMAX- 1.25) AMPS 00 14.06
SERIES FUSE RATING,MAX MODULE SPEC AMPS 00 15
ELECTRICAL EQUIPMENT SCHEDULE
KEY QTY MANUFACTURER MODEL NOTES TRADE
1 14 HYUNDAI HiS-S265RG(265W) PV MODULE SOLAR c)nstrue
2 14 ENPHASE M215-60-21-L-S22-IG PVINVERTER SOLAR irovidons of
3 1 RSTC/SOLADECK 0786-�RS PV ROOF JUNCTION BOX.NEMA 3R SOLAR
4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT.NEMA 3R.24OV.30A SOLAR set oi appro%
5 1 ENPHASE ENVOY PV DATA MONITOR.IZOV SOLAR
6 1 TRID TBO 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR
7 1 TED TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR
a NOTE CUTLER-HAMMER TSD PV BRANCH CIRCU)T BREAKERS: I x 15A-IP(ENVOY) SOLAR
9 NOTE CUTLER-HAMMER TED PV BREAKER.I x 20A-2P.LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR
I i 1 SEWVICEi�PEATNEER.,rMIN. 125A BUS ELEC.
1 112 1: 1 TIED TED U�ILITY PH,120/240V.ZOOA �B262R�ELEC.
1 12 1 1 1 TED I TBD I GROUNDING ELECTRODE LIFER I BLDR.El Fr
CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS
1)CONDITION OF USE(COM I (AMPACITY- TEMP.DERATE-FILL DERATE) VS.REO'D(Imm) ITEM UNIT PANEL
2)TERMINALS(TERM I AMPACITY AT TERMINALS. vs.REQ`D.(IMAX- 1.25) PANEL MFR. CUTLER-HAMMER
KEY SIZE CUIAL INSULATION CALC. AMPACITY W/O MTEMP. FILL RESULT 0' BUS RATING AMPS 200
TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200
A #12 CU I THWN-2 COU 30 0.76 1.0 22.80 12.60 ALLOWED PV PER NEC AMPS 40
TERM 25 25 15.75 20 PV OCPD DEVICE USED AMPS --
B-713- CU I NM-B COU 40 0.91 1.0 36.40 12.60
i TERM 35 35 15.75 20
C *10 CU NM-B COU 40 0.91 1.0 36.40 12.60
I TERM 35 35 15.7s
CONDUCTOR SCHEDULE
KEY 1 C
T FONDUCTORS I CU/AL TYPE LOCATION T ADE
_#12 ENGAGE CABLE.I-*6G.FREE AIR I CU TC-ER ARRAY I S2TR
B I s-#io.i-pia EGC I CU I NM-B(ROMEX) INTERIOR I SOLAR
C 1 3410,1410 EGC I CU I NM-B(ROMEX) INTERIOR I SOLAR
D I CAT5E.ETHERNET CABLE I CU I CAT5E I INTERIOR I SOLAR
0 7
R-": 0-::
ME NOTE IS J
0 0
4W4141 41LIN
G
ROOF EXTERIOR-G�GE
ELECTRICAL DIAGRAM 3.71 KW
LOT#8
LENNAR; ORIGINAL BY: JIM PARKS I DATE:
MENIFEE HILLS 980 MONTECITO DRIVE,#302 REVIEWED BY:TOM FIDDES I DATE,15-12.02
CORONA,CA 92979 REV.# BY DATE DESCRIPTION
,�Sniamast;d
DING TITLE: PAGE#' SCALE: SITE LOCATION: 4571 Broadway Sbeat
INDIVIDUAL 29117 NECTARINE STREET B..Id.r.CO 803N
PLOT PLAN 2 NTS MENIFEE.CA 301447.0300
ELECTRICAL
STRUCTURAL NOTES,
SOLAR CONTRACTOR-
1)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C.
2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS.TO MAXIMUM EXTENT POSSIBLE.
3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT.
4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED.
5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE.
6)THE UNIRAC SOLARMOUNT RACKING SYSTEM A14D SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION
MANUAL.VERSION 227.3.PUB 140113-ICC.JANUARY 2014.
7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH W)SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND THE EDGE I TME
OF THE PV ARRAY I SUB-ARRAY. ki
8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'.
ROOFING CONTRACTOR- 4
1)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'.
2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE
APROVED PRIOR TO PV SYSTEM INSTALLATION.
3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT W)OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOM TO THE ROOF EAVE.PEEL-N-STICK BASE To
BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS.
4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE.
5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS.
6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO
INSTALLATION,
je I permit
A(ral,state
):an;must bc
ELECTRICAL NOTES,
GENERAL-
I)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL).
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NECJCEC.
3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC
WELD.
4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE
MAY BE ELECTRICALLY INSLILATED BECAUSE OF PAINT/FINISH. PAINTfFINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED.
5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE.
6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE.
SOLAR CONTRACTOR-
7)MODULE CERTIFICATIONS WILL INCLUDE UL1703.IEC61646.IEC61730-
8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS.
9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO 114TERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS.
10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM.
11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE
ROOF SURFACE AND SHALL BE MANAGED IN A WORKMI MANNER.
12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122.
13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS.
14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ME BRANCH CIRCUIT.
15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR.
SIGNAGE-
16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES.
17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL HEMS.
18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT k.
19)ALL WIRINGIRACEWAYSIJUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE,'OR EGUIV�ENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10%
BUILDER ELECTRICAL AND SOLAR CONTRACTORS-
20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER.
21)SPACE REQUIREME14TS FOR ALL ELECTRIC&EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26.
MENIFEE HILLS LENNAR: ORIGINAL BY: JIM PARKS DATE:15.12.01
980 MONTECITO DRIVE,#302 REVIEWED BY: TOM FIDDES DATE:15.12.02
CORONA.CA 92879 REV.# BY DATE DESCRIPTION nrl
— sit
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 BroadWay Street
INDIVIDUAL
PLOT PLAN 3 INTS 29117 NECTARINE STREET — Boulder.CO 803N
NOTES MENIFEE.CA — 303.447.0000
CAUTION:
POWER TO THIS BUILDING IS SUPPLIED BY THE
UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS
ARE LOCATED AS SHOWN.
ran
ly
ol the
-�--�SOLADECK WIRE
TRANSITION BOX
(UNDER ARRAY)
Pv AC DISCONNECT
EXTERIOR-GARAGE
UTILITY METER 8
�—�MAIN SERVICE PANEL
(VERIFIED BY BUILDER)
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
1-877-SLR-POWR
PV POWER SOURCE - AC SPECS
AC OPERATING VOLTAGE: 2 4]OV
AC OPERATING CURRENT: 12.6 A
NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION
LENNAR: ORIGINAL BY JIM PARKS DATE:15.12.01
MENIFEE HILLS 980 MONTECITO DRIVE.#302 REVIEWED BY:TOM FIDDES BAT :15.12.02
CORONA,CA 92879 REV.# BY DATE DESCRIPTION t2nomosV6
10LAt
DING TITLE* PAGE#: SCALE: SITE LOCATION: 4571 Bmadway SVeat
INDIVIDUAL 29117 NECTARINE STREET Boulder.CO 803N
PNTS
P� MENIFEE,CA