Loading...
PMT16-04058 City of Menifee Permit No.: PMT16-04058 29714 HAUN RD. Residential Electrical <A-CCELA-> MENIFEE, CA 92586 Type: MENIFEE Date Issued: 01/09/2017 P E R M I T Site Address: 29117 NECTARINE ST, MENIFEE, CA Parcel Number: 333-631-008 92584 Construction Cost $9,353.40 Existing Use: Proposed Use: Description of SOLAR TR 31582-1 MENIFEE HILLS Work: 14 MODULES, 3.71 KW,MASTER PLAN PMT14-00706 LOTS Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA, CA 92879 ATTN GOREEN MUELLER Applicant Phone:9493498269 JEREMIAH ACAYTURRI License Number.,728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISID VIEJO, CA 92656 Fee Description Pti Amount($1 Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 2.00 General Plan Maintenance Fee-Electrical 1 12.60 $294.60 The issuance of this permit shall not prevent the building official from thereafter requiring the comection of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA BldgPermit-Template.rpt Page 1 of 1 BUILDIN & SAFETY PERM IT/PLAN CHECK APPLICATION Menifee DATE PERMIT/PLAN CHECK NUMBER TYPE: F—ICOMMERCIAL ERESIDENTIAL []MULTI-FAMILY F]MOBILEHOME EIPOOL/SPA EISIGN SUBTYPE: ZADDITION []ALTERATION F]DEMOUTION F]ELECTRICAL [:]MECHANICAL E]NEW []PLUMBING El RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit-Plan 2809 3.71kW/14PCS Master Solar PMT#:PMT14-00706 PROJECTADDRESS 29117 Nectarine Street ASSESSOR'S PARCEL NUMBER '(D<:60T 8 TRACT 31582-1 PROPERTY OWNER'S NAME Lermar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302 PHONE (951)817-36BO EMAIL jeremiah.acaytur�@lennar.com APPLICANTNAME Lermar Homes of California,Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona, CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S NAME Lennar Homes of California,Inc. OWNER BUILDER? R]YESE]NO BUSINESSNAME LennarHDmesof California,Inc, ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ $9,353.40 SO FT �Fr APPLICANT'S SIGNATURE '::��DATE 1DO-1/2016 DEPARTMENT DISTRIBUTION 1.00 t zoo CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERHVG FIRE GREEN SMIP INVOICE AMOUNT *?AC4-40 PA�DAIMOUNT OCASH C)CHECK# OCREDITCARD VISA/MC PLAN CHECK FEES PA D AMOUNT 0 CASH 0 CHECK# OCREDITCARD VISA/MC OWNER BUILDER VERIFIED OYES 0 NO DL NUMBER NOTARIZED LETTER 0 YES C NO City of Menifee Building&Safety Department 29714 Haun Rd.Menifee, CA 92586 951-572-6777 www.cityofirrIenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM 1 OTY HER. 1 MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE EYSTEM SIZE 3.71 KW LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE I 14PCS. HYUNDAI I HIS-S265 G (265W) BUYER: INVERTER 1 14 PCS.1 ENPHASE I MZIS-60- LL-SZ2-IG I ROOF TYPE I TILE W/COMPOSITE SHINGLE UN ER ARRAY I DATE: SUB-ARRAY INFORMATION A #2 1 ARRA #3 '1 OF ME Y1FE ARRAY#1 1 ARR I Y I A A BUYER: �OD I . ING A TFLTQTY 1 Z3 1 NA' I NA' DATE HIJILD ND AZIMUTH 1 140- 1 NA' I NA- �-AN APPROVA City of Men!fee 'I'ZVIEWED BY6 Building Dept DEC 13 nproval of these pf ins sha ,,pproval of,any viola ion of n�gulations and ordin inces. Recs--,,-,'�'1044AY1- liobsite until completii n. 91-B* 23-7'FLASHING I 1 101 SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) j- PV AC DISCONNECT ,-�EXTERIOR-GARAGE UTILITY METER S MAIN SERVICE PANEL J� ---- - ---- (VERIFIED BY BUILDER) NOTE:DIMENSIONS ARE SHOWN IN PUNE OF ROOF PUN 2809 ELEVATION B REVERSE ORIENTATION 5 LU10 6 MENIFEE HILLS LENNAR: ORIGINAL By'. JIM PARKS I DATE:15.12.01 980 MONTECITO DRIVE,#302 REVIEWED BY:TOM FIDDES I DATE:15.12.02 CORONA.CA 92879 REV.# BY DATE DESCRIPTION fpmamast;d SOLAt DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Bmaftay Streei INDIVIDUAL 29117 NECTARINE STREET Boulder,CO 803U PLOT PLAN 1 1/16't V-0" MENIFEE,CA 1 303.447.0300 SYSTEM LAYOUT I MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE I CAI-C I UNIT DETAIL LOCATION MENIFEE.CA INV.MAKE INVERTER SPEC ENPHASE TEMP.AMBIENT HIGH(TMAX) ASHRAE 2% 'C 37 INV.MODEL INVERTER SPEC M215-60-2LL-S22-IG TEMP.AMBIENT LOW(TMIN) ASHRAE EXTR.MIN -C -2 INV.MAX POWER.IWAC MAX) INVERTER SPEC WATTS(AC) 225 TEMP.MODULE TEST(TTEST) MODULE SPEC c 25 INV. INPUT V.(Voc MAX) INVERTER SPEC VOLTS(DO 48 TEMP.DELTA LOW(TDELTA) TmIN-TTEST C -27 INV.OUTPUT V.(VAc NON) INVERTER SPEC VOLTS(AC) 240 MOD. MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD. PART NUMBER MODULE SPEC HiS-S265RG INV.OUTPUT CURRENT,IAC INVERTER SPEC AMPS(AC) 0,9 MOD. POWER STC(P) MODULE SPEC WATTS 00 265 INV.PHASE QUANTITY INVERTER SPEC PHASE I MOD. POWER PTC MODULE SPEC WATTS 00 238 COMPLIANCE INVERTER SPEC UL[74111EEE15471-t! DI MOD. OPERATING VOLTAGE(Vmp) MODULE SPEC VOLTS(DO 31.30 INV.GROUNDING INVERTER SPEC I MOD. OPEN CCT.VOLTAGE(Voc) MODULE SPEC VOLTS 00 38.10 INV.QTY,MAX/BRANCH CCT. 1 INV.QTYBC QTY 14 MOD. COEFF.VOLTITEMP(COEF) MODULE SPEC V/-C -0.114 BRANCH CCT.OUTPUT.IMAXBC I (IAC*INV.QTYB0 AMPS(AC) 12-60 MOQ MAX VOLTAGE(VMAXM0D) (VOC�(TD*COEF)) VOLTS(oc) 4I.IB INV.QUANTITY,TOTAL I INV. OTY 14 MOD. OPERATING CURRENT(imp) MODULE SPEC AMPS 00 8.50 TOTAL SYSTEM OUTPUT.MAXTS CIAC fT) MPq""') 1 12.60 MOD. SHORT CCT.CURRENT(Isc) MODULE SPEC AMPS(00 9.00 MOD. MAXIMUM CURRENT DMAX) OSC' 1.25) AMPS(00 11.25 k� MIN.AMPACITY REO'D.PER NEC (IMAX- 1.25) AMPS 00 14.06 SERIES FUSE RATING,MAX MODULE SPEC AMPS 00 15 ELECTRICAL EQUIPMENT SCHEDULE KEY QTY MANUFACTURER MODEL NOTES TRADE 1 14 HYUNDAI HiS-S265RG(265W) PV MODULE SOLAR c)nstrue 2 14 ENPHASE M215-60-21-L-S22-IG PVINVERTER SOLAR irovidons of 3 1 RSTC/SOLADECK 0786-�RS PV ROOF JUNCTION BOX.NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT.NEMA 3R.24OV.30A SOLAR set oi appro% 5 1 ENPHASE ENVOY PV DATA MONITOR.IZOV SOLAR 6 1 TRID TBO 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TED TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR a NOTE CUTLER-HAMMER TSD PV BRANCH CIRCU)T BREAKERS: I x 15A-IP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TED PV BREAKER.I x 20A-2P.LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR I i 1 SEWVICEi�PEATNEER.,rMIN. 125A BUS ELEC. 1 112 1: 1 TIED TED U�ILITY PH,120/240V.ZOOA �B262R�ELEC. 1 12 1 1 1 TED I TBD I GROUNDING ELECTRODE LIFER I BLDR.El Fr CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS 1)CONDITION OF USE(COM I (AMPACITY- TEMP.DERATE-FILL DERATE) VS.REO'D(Imm) ITEM UNIT PANEL 2)TERMINALS(TERM I AMPACITY AT TERMINALS. vs.REQ`D.(IMAX- 1.25) PANEL MFR. CUTLER-HAMMER KEY SIZE CUIAL INSULATION CALC. AMPACITY W/O MTEMP. FILL RESULT 0' BUS RATING AMPS 200 TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 A #12 CU I THWN-2 COU 30 0.76 1.0 22.80 12.60 ALLOWED PV PER NEC AMPS 40 TERM 25 25 15.75 20 PV OCPD DEVICE USED AMPS -- B-713- CU I NM-B COU 40 0.91 1.0 36.40 12.60 i TERM 35 35 15.75 20 C *10 CU NM-B COU 40 0.91 1.0 36.40 12.60 I TERM 35 35 15.7s CONDUCTOR SCHEDULE KEY 1 C T FONDUCTORS I CU/AL TYPE LOCATION T ADE _#12 ENGAGE CABLE.I-*6G.FREE AIR I CU TC-ER ARRAY I S2TR B I s-#io.i-pia EGC I CU I NM-B(ROMEX) INTERIOR I SOLAR C 1 3410,1410 EGC I CU I NM-B(ROMEX) INTERIOR I SOLAR D I CAT5E.ETHERNET CABLE I CU I CAT5E I INTERIOR I SOLAR 0 7 R-": 0-:: ME NOTE IS J 0 0 4W4141 41LIN G ROOF EXTERIOR-G�GE ELECTRICAL DIAGRAM 3.71 KW LOT#8 LENNAR; ORIGINAL BY: JIM PARKS I DATE: MENIFEE HILLS 980 MONTECITO DRIVE,#302 REVIEWED BY:TOM FIDDES I DATE,15-12.02 CORONA,CA 92979 REV.# BY DATE DESCRIPTION ,�Sniamast;d DING TITLE: PAGE#' SCALE: SITE LOCATION: 4571 Broadway Sbeat INDIVIDUAL 29117 NECTARINE STREET B..Id.r.CO 803N PLOT PLAN 2 NTS MENIFEE.CA 301447.0300 ELECTRICAL STRUCTURAL NOTES, SOLAR CONTRACTOR- 1)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS.TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM A14D SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL.VERSION 227.3.PUB 140113-ICC.JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH W)SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND THE EDGE I TME OF THE PV ARRAY I SUB-ARRAY. ki 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. ROOFING CONTRACTOR- 4 1)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT W)OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOM TO THE ROOF EAVE.PEEL-N-STICK BASE To BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION, je I permit A(ral,state ):an;must bc ELECTRICAL NOTES, GENERAL- I)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NECJCEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSLILATED BECAUSE OF PAINT/FINISH. PAINTfFINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703.IEC61646.IEC61730- 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO 114TERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMI MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ME BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL HEMS. 18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT k. 19)ALL WIRINGIRACEWAYSIJUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE,'OR EGUIV�ENT;WIRING/RACEWAYS SHALL BE MARKED EVERY 10% BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREME14TS FOR ALL ELECTRIC&EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. MENIFEE HILLS LENNAR: ORIGINAL BY: JIM PARKS DATE:15.12.01 980 MONTECITO DRIVE,#302 REVIEWED BY: TOM FIDDES DATE:15.12.02 CORONA.CA 92879 REV.# BY DATE DESCRIPTION nrl — sit DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 BroadWay Street INDIVIDUAL PLOT PLAN 3 INTS 29117 NECTARINE STREET — Boulder.CO 803N NOTES MENIFEE.CA — 303.447.0000 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. ran ly ol the -�--�SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) Pv AC DISCONNECT EXTERIOR-GARAGE UTILITY METER 8 �—�MAIN SERVICE PANEL (VERIFIED BY BUILDER) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 2 4]OV AC OPERATING CURRENT: 12.6 A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION LENNAR: ORIGINAL BY JIM PARKS DATE:15.12.01 MENIFEE HILLS 980 MONTECITO DRIVE.#302 REVIEWED BY:TOM FIDDES BAT :15.12.02 CORONA,CA 92879 REV.# BY DATE DESCRIPTION t2nomosV6 10LAt DING TITLE* PAGE#: SCALE: SITE LOCATION: 4571 Bmadway SVeat INDIVIDUAL 29117 NECTARINE STREET Boulder.CO 803N PNTS P� MENIFEE,CA