Loading...
PMT16-04055 City of Menifee Permit No.: PMT16-04055 29714 HAUN RD. Type: Residential Electrical <ACCELA> MENIFEE, CA 92586 MENIFEE Date Issued: 01/0912017 P E R M I T Site Address: 28867 SKYLARK ST, MENIFEE,CA 92584 Parcel Number: 333-631-025 Construction Cost: $10,689.60 Existing Use: Proposed Use: Description of SOLAR TR 31582-1 MENIFEE HILLS Work: 16 MODULES,4.24KW, MASTER PLAN PMT14-00706 LOT 35 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA, CA 92879 ATTN GOREEN MUELLER Applicant Phone: 9493498269 JEREMIAH ACAYTURRI License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTIN GOREEN MUELLER ALISO VIEJO, CA 92656 Fee Description City Amount Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 2.00 General Plan Maintenance Fee-Electrical 1 12.60 $294.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing buillding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA.Bldg_Pe�ii—Temlplatexpt Page 1 of 1 BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATICI N 'Menifee DATE PERMIT/PLAN CHECK NUMBER TYPE: []COMMERCIAL R]RESIDENTIAL F]MULTI-FAMILY [IMOBILEHOME [:]POOL/SPA [:]SIGN SUBTYPE: ZADDITION E]ALTERATION []DEMOLITION E]ELECTRICAL [:]MECHANICAL FINEW [-]PLUMBING [I RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit-Plan 3404 4.24kW/16PCS Master Solar PMT M PMT14-00706 PROJECTADDRESS 28867SkylarkSt ASSESSOR'S PARCEL NUMBER LOT 35 TRACT 31582-1 PROPERTY OWNER'S NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com APPLICANTNAME Lennar Homes of California,Inc. ADDRESS 980 Mantecito Dr.,Suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturti@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNERBUILDER? R]YESF]NO BUSINESSNAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lenner.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ $ 10.689.60 Q FT S FT _�=Z:�:�DATE lQ2/01/2016 APPLICANT'S SIGNATURE CITY STAFF USE ONLY DEPARTMENT DISTRIBUTIO IFEE BUSINESS UCENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN SMIP INVOICE I 014tf W I AMOUNT PAIDAMOUNT 0 CASH 0 CHECK# OCREDITCARD VISA/MC PLAN CHECK FEES PAIDAMOUNT OCASH OCHECK# OCREDITCARD VISA/MC OWNER BUILDER VERIFIED OYES 0 No DLNUMBER NOTARIZED LETTER 0 YES 0 NO City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777 www.cityojmenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OLy— MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 14.24 KW LOCATIONS INDICATED BY THE ILLUSTRATION. n0DULE 1 16 PCS.1 HYUNDAI HiS-S265RG(265W) BUYER: INVERTER 16PCS.1 ENPHASE I M215-60-2LL-S22-IG ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: SUB-ARRAY INFORMATION E ARRAY#1 1 ARR #2 ARLAY#3 u MENIF LY NZ MOD OTY 16 NA BUYER: TILT 23' 1 NA- NA- �--,-uu!Nu ANDISAF AZIMUTH 102- 1 NA' NA- DATE: 11\N APPROVJ I NIPVVED BY pprova�of these plans all no 26'-4'ARRAY iromval of,anyviolation A anyl 27'-2'FLASHING 3 u-6ulations and ordinancc This I F jamie uritil completion. SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE L——————— UTILITY METER& MAIN SERVICE PANEL L z;I———— (VERIFIED BY BUILDER) NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF E—L AN"04 ELEVATION A-REVERSE ORIENTATION I LUIQ`3b MENIFEE HILLS LENNAR: ORIGINAL BY: BRI MORRIS I DAT :15.11.27 980 MONTECITO DRIVE,41302 REVIEWED BY:JIMMY METER I DATE.15.11.30 CORONA.CA 92879 REV.* BY DATE DESCRIPTION ;PnicurnastA SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Bmday Shneet INDIVIDUAL 28867 SKYLARK STREET Bodder.CO 110334 PLOT PLAN 1 1/16"2 1'-0' MENIFEE.CA 303.447,0300 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT I DETAIL LOCATION MENIFEE.CA INV.MAKE INVERTER SPEC ENPHASE TEMP.AMBIENT HIGH(THAX) ASHRAE 2% C 37 INV.MODEL INVERTER SPEC M215-60-2LL-S22-IG TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN -C -2 1NV.MAX POWER,(WAC MAX) INVERTER SPEC WATTS(AC) 225 TEMP,MODULE TEST(TTEST) MODULE SPEC C 25 INV.INPUT V,(VDc MAX) INVERTER SPEC VOLTS(DO 48 TEMP,DELTA LOW(TDELTA) THIN-TTEST C -27 INV.OUTPUT V.(VAC NOM) INVERTER SPEC VOLTS(Ac) 240 MOD.MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD.PART NUMBER MODULE SPEC HtS-S265RG INV.OUTPUT CURRENT, IAC INVERTER SPEC AMPS(AC) 69 Y D MOD.POWER STC(P) MODULE SPEC WATTS(m) 265 INV.PHASE QUANTITY INVERTER SPEC PHASE it MOD.POWER PTC MODULE SPEC WATTS(130 23B COMPLIANCE INVERTER SPEC I UL1741/IEEE1547 MOD.OPERATING VOLTAGE WHIP) MODULE SPEC VOLTS 00 31.30 INV.GROUNDING 11V RTTYER SPEC ISOLATED MOD, OPEN CCT.VOLTAGE(Voc) MODULE SPEC VOL INV.OTY.MAX/BRANCH CCT. V.Q C QTY 16 MOD. COEFF.voLT/TEMP CaEF) MODULE SPEC V/.0 -0.114 BRANCH CCT.OUTPUT. IMAnC I(IAc-INV.QTYec) AMPS(AQ 14.40 MOD. MAX VOLTAGE VMAXMOD) (VOC+(TO-COEF)) VOLTS(oc) 41.18 INV.QUANTITY,TOTAL I INV.QTYT QTY MOD. OPERATING CURRENT(imp) MODULE SPEC AMPS(DO 8.50 TOTAL SYSTEM OUTPUT.IMAXTS I DAt-INV.QTYT) I AMPS(AC) I MOD, SHORT CCT.CURRENT 0sc) MODULE SPEC AMPS DC) 9.00 MOD, MAXIMUM CURRENT(IMAX) OSC* 1.25) AMPS(m) 11.25 MIN.AMPACITY REO'D,PER NEC (]MAX- 1.25) AMPS(n) 14.06 SERIES FUSE RATING.MAX MODULE SPEC AMPS(M) 15 ELECTRICAL EQUIPMENT SCHEDULE KEY QTY MANUFACTURER MODEL NOTES TRADE 1 16 HYUNDAI HiS-S265RG(265W) PV MODULE SOLAR sions c 2 16 ENPHASE M215-60-2LL-S22-IG PVINVERTER SOLAR 3 1 RSTC/SOLADECK 0786-3RS PV ROOF JUNCTION BOX.NEMA 3R SOLAR appy 4 1 CUTLER-HAMMER OG221URB PV AC DISCONNECT,NEMA 3R,24OV.30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR a NOTE CUTLER-HAMMER TOD PV BRANCH CIRCUIT BREAKERS:I X 15A-IP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBD PV BREAKER,I x 20A-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 1 12, 1: 12D I�D LELVjT1CyEi7PEATER..,MIN. 125A BUS ��22 T.F 1 T86 1 UTIL PH.IZUIZ40V.2UUA 1 BLDR��ERC 1 12 1 1 TBD I TBD I GROUNDING ELECTRODE UFER CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS 1)CONDITION OF USE(COU); (AMPACITY- TEMP.DERATE-FILL DERATE)�.REO'D(IMAX) ITEM UNIT PANEL 2)TERMINALS(TERM): AMPACITY AT T RMINALS.vs. REO'D.(ImAX- 1.25) PANEL MFR. CUTLER-HAMMER INSULATION CALC AMPACITY WIO TEMP. FILL RESULT I REO'D OCD BUS RATING AMPS�� KEY SIZE CU/AL TYPE' DERATES DERATE DE USED(A) MAIN—DISCONNECT AMPS 1 NO A #12 cu THWN-2 COU 30 0.76 1.0 22.80 14.40 ALLOWED PV PER NEC AMPS 40 TERM 25 5 18.00 20 PV OCPD DEVICE I qFn AM B #10 cu NM-B COU 40 0.91 1.0— 36-40 14-40 TERM 35 75— 18.00 20 C #10 cu NM-B COU 40 0.91 1.0 36.40 14.40 TERM 35 35 18.00 20 CONDUCTOR SCHEDULE A EY CONDUCTORS 1-#6G.FREE AIR 1 CUIAL TYPE 1 LOCATION TRADE 1,1111 ENGAGE CABLE. I cu TC-ER I ARRAY SOLAR _#10.I_#IO tGC I CU I NM-B(ROMEX) I INTERIOR SOLAR 5 6 C 1 3410,1-#10 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR D I CAT5E.ETHERNET CABLE I CU I CAT5E I INTERIOR I SOLAR 7 SEE NOTE 15 0 tulip zu/ THRRICHR14141410141 IN C 4 45512 ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 4.24 KW LOT#35 MENIFEE HILLS LENNAR: ORIGINAL BY: BRI MORRIS DATE:15.11.27 980 MONTECITO DRIVE.#302 REVIEWED BY:JIMMY METER DATE:15.11.30 CORONA,CA 92879 REV.* BY DATE DESCRIPTION DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broscmy Street INDIVIDUAL 28867 SKYLARK STREET Boulder.CO SM04 PLOT FUN 2 INTS MENIFEE,CA 303.447.0300 ELECTRICAL I STRUCTURAL NOTES, SOLAR CONTRACTOR- 1)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'D.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL,VERSION 227.3,PUB 140113-ICC,JANUARY 2014. A RTM 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(11 SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(Z-)BEYOND THE EDGE OF THE PV ARRAY I SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. 0 ROOFING CONTRACTOR- 1)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3. 2)26 GAUGE INTERLOCKING FLASHING*SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 04 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(0 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE.DOWN TO THE ROOF EAVE. PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 10 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS, 6)BIRDSTOP WILL BE JNSTAILLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. 1),a Pei ederal,! ;ans mv ELECTRICAL NOTES� GENERAL- 1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703.IEC61646,IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER, 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING.OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACKED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)14ARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERJNG. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT t- 19)ALL WIRINGIRACEWAYS/JUNCTION BOXES WILL BE MARKED"PHOTOVOLTAIC POWER SOURCE,'OR EQUIVALENT;WIRINGIRACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. LENNAR: ORIGINAL BY: BRI MORRIS DATE: MENIFEE HILLS 980 MONTECITO DRIVE.#302 REVIEWED BY:JIMMY METER DATE:15.11.30 CORONA.CA 92879 REV.# BY DATE DESCRIPTION 4.2 4��,2amasti§ DWG TITLE: PAGE#: I SCALE- SITE LOCATION: 4571 Sroad�ay Streat INDIVIDUAL 28867 SKYLARK STREET Boulder,CO 803U PLOT PLAN 3 NITS MENIFEE.CA 303.M7.0300 NOTES I CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS IT ARE LOCATED AS SHOWN. I SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) ;Jty �lppt on the PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER a ]-�MAIN SERVICE PANEL (VERIFIED BY BUILDER SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: 14.4 A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION MENIFEE HILLS LENNAR: ORIGI BY BRI MORRIS DATE:15.11.27 980 MONTECITO DRIVE. #302 REVIEWED BY�JIMMY METER DATE:15.11.30 CORONA.CA 92879 REV,# BY DATE I DESCRIPTION mast;6 —`P�l - Siuk $01A. DWG TITLE: PAGE #: I SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 28867 SKYLARK STREET B.Ider,CO 80304 PLOT PLAN 4 NTS MENIFEE,CA 3D&M7.0000 PLACARDS