PMT16-04054 City of Menifee Permit No.: PMT16-04054 29714 HAUN RD. Type: Residential Electrical <A-CCELj-1;? MENIFEE,CA 92-586 MENIFEE Date Issued: 0110912017 P E R M I T Site Address: 28855 SKYLARK ST, MENIFEE, CA 92584 Parcel Number: 333-631-024 Construction Cost: $8,017.20 Existing Use: Proposed Use: Description of SOLAR TR 31582-1 MENIFEE HILLS Work: 12 MODULES,3.18KW,MASTER PLAN PMT14-00706 LOT 34 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA, CA 92879 ATTN GOREEN MUELLER Applicant Phone:9493498269 JEREMIAH ACAYTURRI License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ATTN GOREEN MUELLER ALISO VIEJO, CA 92656 Fee Description Qtv Amount Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 2.00 General Plan Maintenance Fee-Electrical 1 12.60 $294.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for constnict-ton under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA BidgPermit-Template.rpt Page 1 of 1 BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION Wenifee DATE PERMIT/PLAN CHECK NUMBER TYPE: EICOMMERCIAL EIRESIDENTIAL E]MULTI-FAMILY E]MOBILEHOME [-]POOL/SPA OSIGN SUBTYPE: E]ADDITION []ALTERATION F]DEMOUTION DELECTRICAL [-]MECHANICAL [-]NEW []PLLIMBING F-IRE-ROOF-NUMBEROFSQUARFS DESCRIPTION OF WORK Solar Permit-Plan 2686 3.18kW/12PCS Master Solar PMT#: PMT1 4-00706 PROJEcTADDRESS 28855SqarkSt ASSESSOR'S PARCEL NUMBER :3,32—r LOT 34 TRACT 31582-1 PROPERTY OWNER'S NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302 PHONE (951)817-3680 EMAIL leremiah.acayturd@iennar.com APPLICANTNAME Lermar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNERBUILDER? R]YES[]NO BUSINESSNAME Lennar Homes of California,Inc. ADDRESS 980 Montecito Dr.,Suits 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL jeramiah.arayturd@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ $8,017.20 S� LSQFT APPLICANTS SIGNATURE ----DATE 12101/2016 CITYSTAFF USEONLY DEPARTMENT DISTRIBUTION C1 1Y OF MENIFLE HUNNLb�LILtNbh NUMBER BUILDING PLANNING ENGINEERING FIRE � GREEN SMIP INVOICE PAIDAMOUNT I AMOUNT OCASH OCHECK# OCREDITCARD VISA/MC PLAN CHECK FEES PAIDAMOUNT CICASH OCHECK# OCREDITCARD \ASA/MC OWNER BUILDER VERIFIED 0 YES 0 NO DLNUMBER NOTARIZED LETTER 0 YES 0 NO City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777 www.cityaFmenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MFR. IDIL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM S12E 1 3.IBKW LOCATIONS INDICATED BY THE ILLUSTRATION. FODULr 12FCS.1 HYUNDAI I I 65RG(265W) BUYER: ENWEE INVERTER 1 12 PCS.1 ENPHASE I ROOF TYPE I TILE W1 COMPOSITE SHINGLE UNDER ARRAY DATE: "' 'ILDING AND SA SUB-ARRAY INFORMATION ARRAY#1 1 ARty#2 1 AR�Ly#3 n-0-11 OTY 1 iz NA NA BUYER: APPROI AL TILT 23* 1 NA- I NA- DATE: AZIMUTH 1 210- 1 M. I NA' lloo;� city of menitee Building Dept MED 0 DEC 13 2016 "Proval of these plans!hall no I r I 1 3' 1 VIA. l�proval of,any violation )f any I 'a, lations and ordinance;. This Obsite until completion. z 10 SOLADECK WIRE TRANSIT10N BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE----_, UTILITY METER 6 RAIN SERVICE PANEL-1-4 (VERIFIED By BUILDER) I L————————-J I NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF PUN 2687(2X) ELEVATION R ORIENTATION I LOT#54 MENIFEE HILLS LENNAR: ORIGINAL BY: BRI MORRIS I DATE:15.11.27 960 MONTECITO DRIVE,#302 REVIEWED BY:JIMMY METER I DATE,15.11.30 CORONA,CA 92879 REV.# BY DATE DECRIPTION 01 SM 16.08.25 CHANGE TO PLAN 2687(24 VniamastA DWG TITLE: PAGE#: SCALE: SITE LOCATION: SOLAR — 4571 Broadmy S"et INDIVIDUAL 28855 SKYLARK STREET Boulder,CO 00304 PLOT PLAN 1/16'=V-O' MENIFEE,CA 301"7.0200 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE.CA INV.MAKE INVERTER SPEC ENPHASE TEMP.AMBIENT HIGH(THAX) ASHRAE 2% C 37 INV. MODEL INVERTER SPEC M215-60-2LL-S22-IG TEMP.AMBIENT LOW(THIN) ASHRAE EXTR.MIN 'C -2 INV. MAX POWER,ONAC MAX) INVERTER SPEC WATTS(AC) 225 TEMP.MODULE TEST(TTEST) MODULE SPEC C 25 INV. INPUT V.(VOC MAX) INVERTER SPEC VOLTS(M) 48 TEMP.DELTA LOW(TOELTA) THIN-TTEST C -27 INV. OUTPUT V,(VAC NOM) INVERTER SPEC VOLTS(AC) 240 MOD,14ANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 Ty I MOD. PART NUMBER MODULE SPEC HiS-S265RG INV.OUTPUT CURRENT. IAC INVERTER SPEC AMPS(AC) 0.9 MOD. POWER STC(P) MODULE SPEC WATTS(Dc) 265 INV.PHASE QUANTITY INVERTER SPEC PHASE I MOD. POWER PTC MODULE SPEC WATTS(DC) 238 COMPLIANCE INVERTER SPEC UL174IlEEEI547 MOD, OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(OC) 31.30 INV.GROUNDING jNVERTE.R SPEC OLATED MOD. OPEN CCT.VOLTAGE(Voc) MODULE SPEC VOLTS(OC) 38-10 INV.CITY,MAX/BRANCH CCT. 1 V.OTY C 1 OTY HSI MOD. COEFF.VOLT/TEMP(COEF) MODULE SPEC W-C -0.114 BRANCH CCT.OUTPUT, IMAX8C I(IAC-INV.QTYBC) I AMPS(AC) 1 10.80 MOD. MAX VOLTAGE(VMAMOD) (VOC+(TD*COEF)) VOLTS(OC) 41.18 INV. QUANTITY,TOTAL INV.OTYT I OTY I iz U MOD. OPERATING CURRENT(imp) MODULE SPEC AMPS(OC) 8.50 TOTAL SYSTEM OUTPUT,IMAXTS (IAC-INV.QTYT) AMPS(AC) I O.SD MOD. SHORT CCT. CURRENT(ISC) HODU_E SPEC AMPS(OC) 9.00 MOD. MAXIMUM CURRENT(IMAX) (ISC*1.25) AMPS CDC) 11.25 MIN.AMPACITY REQ'D.PER NEC (IMAX-1.25) AMPS(OC) 14.06 SERIES FUSE RATING.MAX MODULE SPEC AMPS 00 15 :onstri ELECTRICAL EQUIPMENT SCHEDULE i!ons c KEY CITY MANUFACTURER MODEL NOTES TRADE 1 12 HYUNDAI HiS-SZ65RG(265W) PV MODULE SOLAR )f appri 2 12 ENPHASE M215-60-2[L-S22-IG PVINVERTER SOLAR 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX.NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT.NEMA 3R.24OV.30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR 6 1 TED TED 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TED CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR a NOTE CUTLER-HAMMER TED PV BRANCH CIRCUIT BREAKERS;I x 15A-IP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TED PV BREAKER.I x ZOA-21p.LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 1 1 MIN. 125A BUS T:5D 122 EVICE PANEL, BLDR ELEC 11 1 1 TED 1 UTILITY RETER.IPH.120/240V,200A 1 BLDR�ELEC'. i TED I TED I GROUNDING ELECTRODE UFER I BLDR.ELEC. CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS 1)CONDITION OF USE(COU): (AMPACITY-TEMP. DERATE-FILL DERATE)VS.REDID OMAX) ITEM UNIT PANEL 2)TERMINALS(TERM); AMPACITY AT TERMINALS.vs.REOT IMAX- 1-25) PANEL MFR. CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALC. AMPACITY W10 TEMP, FILL RESULT REO'D QED BUS RATING AMPS 200 TYPE DERATES DERATE DERATE (A) (A) USED(A) —MAIN DISCONNECT AMPS 200 A #12 CU THWN-Z COU 30 0.76 1 1.0 22.80 10-80 ALLOWED PV PER NEC AMPS 40 TERM 25 1 25 13.50 20 PV OCPD DEVICE USED AMPS 20 #10 CU NM-8 COU 40 0.91 1.0 36.40 10.80 TERM 35 35 13.50 20 NM_B COU 40 0.91 1.0 36.40 10.90 TERM 35 35 113-50 20 CONDUCTOR SCHEDULE KEY CONDUCTORS CUIAL I TYPE 1 LOCATION 1 aADE IT#12 SOLAR 5 ENGAGE CABLE,[-#bG.FREE AIR I CU I TC-ER I ARRAY 6 B _#IO'I-ANG EGC I CU I NM-B(ROMEX) INTERIOR I SOLAR C 3-#10.1410 EGC I CU I NM-B OROMEX) INTERIOR I SOLAR D CAT5E.ETHERNET CABLE ICU I CATSE I INTERIOR ISOLAR SEE NOTE 15 Ica) 15A/IP 4 14 14 ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 3.IBKW LOT#34 MENIFEE HILLS LENNAR: ORIGINAL BY: SRI MORRIS I DATE: 980 MONTECITO DRIVE.#302 REVIEWED BY:JIMMY METER I DATE:15.11.30 CORONA.CA 92879 REV.# Y DATE I DESCRIPTION 01 SM 1 .0 .2 MANGE TO PLAN 2687(24 1_�M ftlmasri§ DWG TITLE: PAGE#: SCALE: SITE LOCATION: SOLAR 4571 Bro.d�y Street INDIVIDUAL 28855 SKYLARK STREET Boulder,CO 80304 PLOT PLAN 2 NTS ELECTRICAL I MENIFEE.CA 303.447,0300 STRUCTURAL NOTE& SOLAR CONTRACTOR- 1)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN a'D.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS.TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT- 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. PARTMI 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL.VERSION 227.3.PUB 140113-ICC,JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(I-)SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. ROOFING CONTRACTOR- 1)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF Z'. 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL"TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT 00 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. I a P-rl 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE-BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO ia eral,sta INSTALLATION. p!a is must ELECTRICAL NOTES: GENERAL- 1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE EC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 40 NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING.NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE U1_1703.IEC61646.IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM- 11)MODULE AND ENPHASE WIRING SMALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT k. 19)ALL WIRINGIRACEWAYS/JUNCTION BOXES WILL BE MARKED"PHOTOVOLTAIC POWER SOURCE.'OR EQUIVALENT:WIRINGIRACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-L[KE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY: BRI MORRIS I DATE:1 .11,2 MENIFEE HILLS LENNAR: REVIEWED BY:JIMMY METER I DATE.15.11.30 980 MONTECITO DRIVE,#302 CORONA,CA 92879 REV.# BY DATE DESCRIPTION 01 SM 16.OB.25 HANGE TO PLAN 2687(2X) Onamast;6 SOLAR DING TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway S�t INDIVIDUAL PLOT PLAN 3 NTS 28855 SKYLARK STREET B..Id.,.CO 80304 MENIFEE,CA 303.447.03DO NOTES I CAUTION: 7 POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. sPATE (r 4an fV )�on the SOLQECK WIN' TRANSITION BOX� BINDER ABRAY� PV AC DISCONNECT EXTE�IOIZ-6�46 .T"T T.Y NE . NE�" 1 NICE ME; MRIFIED BY BUILDER) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: 10.8 A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION MENIFEE HILLS LENNAR; ORIGINAL BY: BRI MORRIS DATE:15.11.27 980 MONTECITO DRIVE.#302 REVIEWED BY:JIMMY METER DATE:15.11.30 CORONA,CA 92879 REV.# BY DATE DESCRIPTION 01 SM 16.OB.25 C11ANGE TO PLAN 2687(2)0 masb6 — Vt ICIA. DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 4571 Broadway SVeet INDIVIDUAL 28855 SKYLARK STREET awlder,CO 90� PLOT PLAN A NTS MENIFEE.CA 301�7.0300 PLACARDS I