PMT16-04053 City of Menifee Permit No. PMT16-04053
29714 HAUN RD. Type: Residential Electrical
<A-CCELJ MENIFEE, CA 92586
MENIFEE Date Issued: 0110912017
P E R M I T
Site Address: 29288 ABELIA GLEN ST, MENIFEE, CA Parcel Number: 333-624-003
92584 Construction Cost: $14,593.40
Existing Use: Proposed Use:
Description of SOLAR TR 31582-1 MENIFEE HILLS
Work: 14 MODULES,3.71 KK MASTER PLAN PMT14-00706
LOT 117
Owner Contractor
LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC
980 MONTECITO DR#302 25 ENTERPRISE
CORONA, CA 92879 ATTN GOREEN MUELLER
Applicant Phone: 9493498269
JEREMIAH ACAYTURRI License Number:728102
LENNAR HOMES OF CALIFORNIA INC
25 ENTERPRISE
ATTN GOREEN MUELLER
ALISO VIEJO, CA 92656
Fee Description ON Amount($
Solar, Residential or Small Commercial 1 252.00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 2.00
General Plan Maintenance Fee-Electrical 1 12.60
$294.60
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of emors in the plans and
specifications or from preventing bulliding operations being carded on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA Bldg_Permit Template.rpt Page I of I
BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION
DATE PERMIT/PLAN CHECK NUMBER
TYPE: [-]COMMERCIAL EIRESIDENTIAL E]MULTI-FAMILY EIMOBILEHOME [-]POOL/SPA []SIGN
SUBTYPE: ZADDITION F]ALTERATION F]DEMOLITION [-]ELECTRICAL [-]MECHANICAL
E]NEW []PLUMBING [:1 RE-ROOF-NUMBER OF SQUARES
DESCRIPTION OF WORK Solar Permit-Plan 3105 3.71kWI14PCS
Master Solar PMT#: PMT14-00706
PROJECTADDREss 2928BAbella Glen Street
ASSESSOR'S PARCEL NUMBER .332-6�Z4-11DO3 LOT 117 TRACT 31582-1
_7
PROPERTY OWNER'S NAME Lermar Homes of California, Inc.
ADDRESS 980MantedtoDr.,SuIta302
PHONE (951)B17-3680 EMAIL jeremiah.araytuM@Iennar.com
APPLICANTNAME Lermar Homes of California, Inc.
ADDRESS 980 Montecito Dr., Suite 302,Corona,CA 92879
PHONE (951)817-3680 EMAIL jeremiah.arayturri@lennar.com
CONTRAcroWS NAME Lennar Homes of California,Inc. OWNERBUILDER? R]YESEINO
BUSINESSNAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879
PHONE (951)817-3680 EMAIL leremiah.acaytur�@lennar.com
CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B
VALUATION$ $ 14.593-40 SO L-SCL FT
APPLICANT'S SIGNATURE DATE 12/01/2016 77
CITY STAFF USE ONLY
DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER
BUILDING PLANNING ENGINEERING FIRE GREEN Igo SMIP
INVOICE I
AMOUNT A lq:k��AID AMOUNT OCASH OCHECK# OCREDrrCARD VISA/MC
PLAN CHECK FEES I PAIDAMOUNT 0 CASH 0 CHECK# OCREDITCARD VISA/MC
OWNER BUILDER VERIFIED OYES 0 NO DL NUMBER NOTARIZED LETTER 0 YES 0 NO
City of Menifee Building&Safety Department 29714 Houn Rd. Menifee, CA 92586 951-672-5777
www.cityofmenlj`ee.us Inspection Request Line 951-246-6213
SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED
ITEM CITY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE
SYSTEM SIZE 3.71 KW I I LOCATIONS INDICATED BY THE ILLUSTRATION.
tODULE 14 PCS-1 HYUNDAI I HiS-S265 G(265W) BUYER:
INVERTER 14 PCS.j ENPHASE I M215-60- LL-S22-IG
ROOF TYPE TILE W/COMPOSITE SHINGLE UN ER ARRAY DATE:
SUB-ARRAY INFORMATION C� j f U� MENIFEE
I ARRE#1 1 ARRLY#2 1 AELY#3 EU11 DING AND SAFEn
MDO OTY 1 a 2 2 BUYER:
1 23'
T LT 23. 23.
AZIMUTH 180c 90c 270c DATE-
r,ity of Menifee REVIEWED Balft
Building Dept
DEC 13 2016 oproval of these plans shall not be con
�oproval of,any violation of any p ovisior
1 egulations and ordinances. This s!t of a�
Receiveu iubsite until completion,
23'-1'ARRAY
23'-Il'FLASHING
SOLADECK WIRE
TRANSITION BOX
(UNDER ARRAY)
Z
PV AC DISCONNECT
L EXTERIOR-GARAGE
TNTY ETER a
VICE
AIN�E`l PANEL
j
:E (VERIFIED BY BUILDER) 0
151-51 13,61 L51-5*L
too
NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF N
(!5
PLAN 3105 ELEVATION A-R
ORIENTATION I 07F171
MENIFEE HILLS LENNAR ORIGINAL BY: BRI MORRIS DATE;15.11.27
980 MONTECITO DRIVE.#502 REVIEWED BY:JIMMY METER DATE 15JI.30
CORONA,CA 92879 REV.# BY DATE DESCRIPTION
01 KA 16.7.22 PLAN REVISION SPmamcxs136
SOLAR
DWG TITLE: PAGE# SCALE: SITE LOCATION 4571 Brwftay Steet
IN 29288 ABIELIA GLEN STREET BoWder.CO 80304
PL 1'-0' MENIFEE,CA 303,447.0300
SY
MODULE SPECS AND CALCULATlONS INVERTER SPECS AND CALCULATIONS
ITEM NOTEI CALC UNIT DETAIL ITEM NOTE ICALC UNIT DETAIL
LOCATION MENIFEE.CA INV.MAKE INVERTER SPEC ENPHASE
TEMP.AMBIENT HIGH(TMAX) ASHRAE 2% C 37 INV.MODEL INVERTER SPEC M215-60-2LL-S22-IG
TEMP.AMBIENT LOW(TMIN) ASHRAE EXTR.MIN cC -2 INV.MAX POWER,(WAC MAX) INVERTER SPEC WATTS(AC) 225
TEMP.MODULE TEST(TTEST) MODULE SPEC C 25 INV.INPUT V.(Voc MAX) INVERTER SPEC VOLTS(00 48
TEMP,DELTA LOW(TOB-TA) THIN-TiEST C -27 INV.OUTPUT V.(VAc NOM) INVERTER SPEC VOLTS(AC) 240
MOD. MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60
MOD. PART NUMBER MODULE SPEC HiS-S265RG INV.OUTPUT CURRENT.IAC INVERTER SPEC AMPS(A0 0.9 "PAF
MOD. POWER STC(P) MODULE SPEC WATTS(oc) 265 INV.PHASE QUANTITY INVERTER SPEC PHASE I
MOD. POWER FTC MODULE SPEC WATTS(cc) 238 COMPLIANCE INVERTER SPEC UL174]/IEEE1547
MOD. OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(DC) 31.30 INV.GROUNDING j.NVtRTER SPEC SOLATED
MOD. OPEN CCT.VOLTAGE(Voc) MODULE SPEC VOLTS(DC) 38.10 1NV.OTY,MAX I BRANCH CCT. 1 V GTYOC OTY 1:Z
MOD, COEFF. VOLTITEMP(COEF) MODULE SPEC W-C -0.114 BRANCH CCT.OUTPUT.IMAXBC I (IAC-INV.GTYaC) I AMPS(AQ 1 12.60
MOD. MAX VOLTAGE(VMAXMOD) (VOC t(TD-COEF)) VOLTS 00 41.18 INV.QUANTITY,TOTAL I INV.QTYT I OTY 1 4
MOD. OPERATING CURRENT(IMP) MODULE SPEC AMPS(130 8.50 TOTAL SYSTEM OUTPUT,IMAXTS (IAC-INV.QTYT) I AMPS(AC) 1 12.60
MOD. SHORT CCT.CURRENT 0sc) MODULE SPEC AMPS(cc) 9.00
MOD. MAXIMUM CURRENT(IMAX) Osc- 1.25) AMPS(oc) 11.25
MIN.AMPACITY REG'D,PER NEC (IMAX- L25) AMPS 00 14.06
SERIES FUSE RATING.MAX MODULE SPEC AMPS(130 ,15
ELECTRICAL EQUIPMENT SCHEDULE
KEY QTY MANUFACTURER MODEL NOTES TRADE rie fedi
I Il. HYUNDAI HiS-S265RG(265W) PV MODULE SOLAR
2 14 ENPHASE M215-60-2LL-S22-IG PVINVERTER SOLAR ed plan
3 3 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX.NEMA 3R SOLAR
4 1 CUTLER-HAMMER DGZZIURB PV AC DISCONNECT,NEMA 3R.240V.30A SOLAR
5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR
6 1 TED TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR
7 1 TED TBD CATS FORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR
a NOTE CUTLER-HAMMER TED PV BRANCH CIRCUIT BREAKERS;I x 15A-IP(ENVOY) SOLAR
9 NOTE CUTLER-HAMMER TED PV BREAKER,I x 20A-2P,LOCATE AT OPPOSITE END OF BUS FROM 14AIN BREAKER SOLAR
SMVICE A ER...MIN. I2SA BUS KM L C.
B2 �2 TLf_P P 1 BLDR�E C�
E EC
1 112 1 1 1 4B D TIBD FETE H. I2Of24OV.ZOOA CIE
1 12 11 1 TED I TEID GROUNDING ELECTRODE UFER I EC
CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS
1)CONDITION OF USE(COU): I (AMPACITY - TEMP. DERATE-FILL DERATF) vs.REO'D(IMAX) ITEM UNIT PANEL
2)TERMINALS(TERM): AMPACITY AT TERMINALS. vs.REO'D.(IMAX- 1.25) PANEL MFR. CUTLER-HAMMER
CALC AMPACITY WrO TEMP. FILL RESULT REO'D OCD BUS RATING AMPS 200
KEY SIZE CU/AL INSULATION
TYPE DERATES DERATE DERATE (A) (A) USED(A) HAIN DISCONNECT AMPS 200
A #12 CU THWN-2 COU 30 0.76 1 La 22.80 12.60 ALLOWED PV PER NEC AMPS 40
1 1 TERM 25 1 25M 15.75 20 PV OCPD DEVICE USED I AMPS 20
#10 i CU NM-B COU 40 0.91 1 LO 36.40 12.60
i TERM 35 1 35 15.75 20
#10 1 CU NM-B COU 40 0.91 1.0 56.40 12.60
_LERM 35 1 35 15.75 To-I
SCHEDULE
KEY ICONDUCTORS 1 CU/AL 1 TYPE 1 LOCATION TRADE
A 1 1,#IK.ENGAGE CABLE. 146G.FREE AIR I CU I TC-ER IARRAY I SOLAR
8 _#10. _#10 EGC I CU I NM-BUROMEX) I INTERIOR I SOLAR
C 13410. -#10 EGC I Cu I NM-B(ROMEX) I INTERIOR I SOLAR
D I CATSE.ETHERNET CABLE I CU I CATSE I INTERIOR I SOLAR
7
SEE NOTE 15
I-SAPP
21--
L
IG
ROOF EXTERIOR-GARAGE
ELECTRICAL DIAGRAM 3.71 KW
LOT#117
ORIGINAL BY: BRI MORRIS I DATE:15.11.27
MENIFEE HILLS LENNAR: REVIEWED BY:JIMMY METER I DATE:15.11.30
980 MONTECITO DRIVE.#302
CORONA,CA 92879 REV.# By DATE DESCRIPTION
-71 7A 16.7.22 PLAN REVISION
V? %oLAe
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Steel
INDIVIDUAL 29288 AGELIA GLEN STREET - Boulder,CO 803M
Pi NTS 303A47.030
Et MENIFEE.CA
STRUCTURAL NOTES
SOLAR CONTRACTOR-
1)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MGDUI E RACKING RAILS AT NOT GREATER THAN 48-O.C�
2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE.
3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT.
4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED.
5)PV ARRAY WILL BE A MINIMUM OF 3*ABOVE THE COMPOSITE SHINGLE ROOF SURFACE.
6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION
MANUAL,VERSION 227.3,PUB 140113-ICC,JANUARY 2014. MEA
7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(1*)SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND THE EDGE
OF THE PV ARRAY I SUB-ARRAY.
B)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LE14GTH OF GREATER THAN 40'.
ROOFING CONTRACTOR-
1)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3%
2)26 GAUGE INTERLOCKING FLASHING'SIDEWALV TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION- IT SHALL BE
APROVED PRIOR TO PV SYSTEM INSTALLATION-
3)FEEL-N-STICK BASE TO BE INSTALLED ONE FOOT W)OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO
BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS.
4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RU14 FROM ABOVE THE PV ARRAY To THE ROOF EAVE.
5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS.
BY ROOFER PRIOR TO TI,.t 0
6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIRDSTOP TO BE SPECIFIED TI:t o
INSTALLATION-
��ate al
!st be k
ELECTRICAL NOTES
GENERAL-
1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL).
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NECICEC.
3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC
WELD.
4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING.NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE
MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED.
5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE.
6)ALL CONDUCTORS WILL HAVE A 90cC RATING TO ENSURE CODE COMPLIANCE.
SOLAR CONTRACTOR-
7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646. IEC61730.
8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS.
9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS.
10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT Wl ENPHASE MICRO-INVERTER SYSTEM.
11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS, WIRING SHALL NOT MAKE C014TACT WITH THE
ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER.
12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122.
13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS.
14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT.
15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR.
SIGNAGE-
U5)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES.
17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS.
18)MARKING I PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT t.
19)ALL WIRINGiRACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE."OR EQUIVALENT;WIRING/RACEWAYS SHALL BE MARKED EVERY Ia..
BUILDER ELECTRICAL AND SOLAR CONTRACTORS-
20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER.
21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26.
MENIFEE HILLS LENNAR: ORIGINAL BY BRI MORRIS DATE:15.11.27
980 MONTECITO DRIVE.#302 REVIEWED BY: JIMMY METER DATE:15.11.30
CORONA,CA 92879 REV�# B
_LY DATE DESCRIPTION
KA 16.7.22 PLAN REVISION mast6
Sm SOLAR
DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 4571 Bmaftay StrRtt
INDIVIDUAL 29288 ABELIA GLEN STREET Souldw,DO 803N
PLOT PLAN 3 NTS MENIFEE.CA 303.447.030
NOTES I
CAUTION:
POWER TO THIS BUILDING IS SUPPLIED BY THE
UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS
ARE LOCATED AS SHOWN.
SOLADECK WIRE the
TRANSITION BOX
(UNDER ARRAY)
PV AC DISCONNECT
EXTERIOR-GARAGE
UTILITY METER a
MAIN SERVICE PANEL
(VERIFIED BY BUILDER)
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
1-877-SLR-POWR
PV POWER SOURCE - AC SPECS
AC OPERATING VOLTAGE: 240 V
AC OPERATING CURRENT: 12.6 A
NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION
ORIGINAL BY: SRI MORRIS I DATE!15.1127
MENIFEE HILLS LENNAR: REVIEWED BY!JIMMY METER I DATE:15.11.30
980 MONTECITO DRIVE.#302
CORONA.CA 92879 REV.# BY DATE DESCRIPTION
01 KA 16.7.22 PLAN REVISION VnamastIi
IOLA.
DWG TITLE: PAGE#: I SCALE: SITE LOCATION: - 4571 Smadway SUeet
INDIVIDUAL 29288 ABELIA GLEN STREET Sodder,CO 80304
PLOT PLAN A NTS 303A47.0300
-PLACARDS MENIFEE.CA