PMT16-04052 City of Menifee Permit No.: PMT16-04052
29714 HAUN RD. Type: Residential Electrical
<A-CCIELA> MENIFEE, CA92586
MENIFEE Date Issued: 01/09/2017
P E R M I T
SiteAddress: 29300 ABELIA GLEN ST, MENIFEE,CA Parcel Number: 333-624-002
92584 Construction Cost: $8,017.20
Existing Use: Proposed Use:
Description of SOLAR TR 31582-1 MENIFEE HILLS
Work: 12 MODULES, 3.18KVV, MASTER PLAN PMT14-00706
LOT 116
Owner Contractor
LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC
980 MONTECITO DR#302 25 ENTERPRISE
CORONA, CA 92879 ATTN GOREEN MUELLER
Applicant Phone: 9493498269
JEREMIAH ACAYTURRI License Number.728102
LENNAR HOMES OF CALIFORNIA INC
25 ENTERPRISE
ATTN GOREEN MUELLER
ALISO VIEJO, CA 92656
Fee Description QtV Amount($1
Solar, Residential or Small Commercial 1 252.00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 2.00
General Plan Maintenance Fee-Electrical 1 12.60
$294.60
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or kom preventing bulliding operations being carried on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA Sidg_Perniii-Template.ript Page I of 1
BUILDING SAFETY PERMIT/PLAN CHECK APPLICATION
Menifee
DATE PERMIT/PLAN CHECK NUMBER PM71(0,
TYPE: F—ICOMMERCIAL [E]RESIDENTIAL [—]MULTI-FAMILY F]MOBILEHOME F]POOL/SPA FISIGN
SUBTYPE: EADDITION F]ALTERATION []DEMOLITION []ELECTRICAL El MECHANICAL
FINEW F]PLUMBING El RE-ROOF-NUMBER OF SQUARES
DESCRIPTION OF WORK Solar Permit-Plan 2033 3.18kW 112 PCS
Master Solar PMT*PMT14-00706
PROJECTADDRESS 2930OAbelia Glen Street
ASSESSOR'S PARCEL NUMBER C2Lj-()02! LOT 116 TRACT 31582-1
PROPERTY OWNER'S NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr.,Suite 302
PHONE (951)817-3680 EMAIL jeremiah.acayturTi@lennar.com
APPLICANTNAME Lennar Homes of California,Inc.
ADDRESS 980 Montecito Dr.,Suite 302, Corona,CA 92879
PHONE (951)817-3680 EMAIL jeremiah.acayturd@lennar.com
CONTRACTOR'S NAME Lennar Homes of California,Inc. OWNERBUILDER? R]YESEINO
BUSINESSNAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA92879
PHONE (951)817-3680 EMAIL leramiah.acayturii@lennar.com
CONTRACTOWS STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B
VALUATION$ $8.017.20 L SQ FT
12101/2016
APPLICANT'S SIGNATURE DATE
CITY STAFF USE ONLY
DEPARrMEN`r DITrRIBUTION 0 C11 Y OF MENIFEE BUSINnb ULhNSL NUWM
BUILDING PLANNING ENGINEERING FIRE I GREEN SMIP
INVOICE I aqqbo I
AMOUNT PAIDAMOUNT 0 CASH 0 CHECK# 0 CREDIT CARD VISA/MC
PLAN CHECK FEES PAIDAMOUNT 0 CASH 0 CHECK# OCREDITrARD VISA/MC
OWNER BUILDER VERIFIED OYES -1 No DLNUMBER NOTARIZED LETTER 0 YES 0 NO
City of Menifee Building&Safety Department 29714 Houn Rd. Menfee, CA 92586 951-572-6777
www.cityofmenlfee.us Inspection Request Line 951-246-6213
SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED
ITEM OTY MFR. 1 MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE
L Y9TEM SIZE 1 3.18KW I LOCATIONS INDICATED BY THE ILLUSTRATION.
MODULE 12 PCS.1 HYUNDAI I HIS-5265 G(265W) I BUYER:
INVERTER 1 12 PCS.1 ENPHASE I M215-60- LL-S22-IG I
ROOF TYPE I TILE W/COMPOSITE SHINGLE UN ER ARRAY I DATE-
SUB-ARRAY INFORMATION
1.,; 1 -1 OF MENIFEE
ARRAY#1 1 AR A #2 1 AR A_Y#3
Y L
MOD QTY 1 12 LNA NA BUYER: SUILDING AND SAF
71_
LT i7' I NA- I NA'
AZIMUTH I 270a I NA* I NAc DATE-
KIEVIEWED BY
-Approval of these planssl all nol
approval of,any violation 11 any I
I F-----------—————————— regulations and ordinance This
jobsite until completion.
4 4
-j
SOLADECK WIRE
SOL I CK WI OX
:TRANSITION BOX
PV AC DISCONNECT
EXTERIOR-GARAGE--��
UTILITY METER& 1
MAIN SERVICE PANEL---�
(VERIFIED BY BUILDER) S TION 8
Y)
(UNDER ARRAY)
NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF N
PLAN 2033 ELEVATION 8
ORIENIATION I LOT#116
MENIFEE HILLS LENNAR: ORIGINAL BY: SRI MORRIS CAT :1 .11.2
980 MONTECITO DRIVE. #302 REVIEWED BY:JIMMY METER I DATE:15.11.30
CORONA,CA 92879 REV.#_ BY I DATE I DESCRIPTION
22annasbib
DWG TITLE; PAGE#; SCALE: SOLAR
SITE LOCATION: 4571 Bmadmy SIreet
INDIVIDUAL 29300 ADELIA GLEN STREET Boulder,GO 80304
PLOT PLAN 1 1/16'=1'-0" MENIFEE.CA 303.447.0300
SYSTEM LAYOUT
MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS
ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL
LOCATION MENIFEE.CA INV.MAKE INVERTER SPEC ENPHASE
TEMP.AMBIENT HIGH(TMAX) ASHRAE 2% C 37 INV.MODEL INVERTER SPEC 14215-60-2LL-S22-IG
TEMP,AMBIENT LOW(THIN) ASHRAE EXTR_MIN 'C -2 INV.MAX POWER.(WAC MAX) INVERTER SPEC WATTS JAC) 225
TEMP.MODULE TEST(TTEST) MODULE SPEC C 25 INV. INPUT V.(Voc MAX) INVERTER SPEC VOLTS(00 48
TEMP.DELTA LOW(TDELTA) TmIN-TTEST C -27 INV.OUTPUT V.(VAc NOM) INVERTER SPEC VOLTS(AC) L40
MOD. MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 Y DI
MOD� PART NUMBER MODULE SPEC HtS-S263RG INV.OUTPUT CURRENT.JAC INVERTER SPEC AMPS JAC) 0.9
MOD.POWER STC(P) MODULE SPEC WATTS 00 265 INV.PHASE QUANTITY INVERTER SPEC PHASE I
MOD. POWER PTC MODULE SPEC WATTS(DO 239 1 COMPLIANCE INVERTER SPEC U-174111EEE1547
MOD. OPERATING VOLTAGE(VMP) MODU_E SPEC VOLTS(00 31.30 INV.GROUNDING jtLVLRTTE.R SPEC SOLATED
NV' Y C 1!�
MOD. OPEN OCT.VOLTAGE(VOC) MODULE SPEC VOLTS(DC) 38.10 INV.OTY,MAX/BRANCH CCT_ 1 1 OTY 2
MOQ COEFF.VOLT/TEMP(COEF) MODULE SPEC V/-C -0.114 BRANCH OCT.OUTPUT, IMAXBC I(IAC-INV.GTYSC) AMPS JAC) .80
MOD. MAX VOLTAGE(VMAMOD) (VOC+(TD-COEF)) VOLTS(oc) 41.18 INV.QUANTITY,TOTAL I INV.GTYT OTY
MOD. OPERATING CURRENT(imp) MODULE SPEC AMPS(00 8.50 TOTAL SYSTEM OUTPUT,IMAXTS I OAC-INV.QTYT) I AMPS JAC) 110.80
MOD. SHORT OCT.CURRENT 0sc) MODULE SPEC AMPS(DC) 9.00
MOD. MAXIMUM CURRENT(IMAX) OSC - 1.25) AMPS(DC) 11.25
MIN.AMPACITY REO'D,PER NEC (IMAX- 1.25) AMPS 00 14.06
SERIES FUSE RATING.MAX MODULE SPEC AMPS 00 15 -.Onstn
ELECTRICAL EQUIPMENT SCHEDULE ions c
KEY (ITY MANUFACTURER MODEL NOTES TRADE
1 12 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR I appp
2 12 ENPHASE M215-60-2LL-S22-IG PVINVERTER SOLAR
3 1 RSTC ISOLADECK 0786-3R5 PV ROOF JUNCTION BOX.NEMA 3R SOLAR
4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,24OV.30A SOLAR
5 1 ENPHASE ENVOY PV DATA MONITOR. 120V SOLAR
6 1 TBD TBO 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR
7 1 TBD TBD CAT5 PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR
a NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS;I X 15A-IP(ENVOY) SOLAR
9 NOTE CUTLER-HAMMER TSD PV BREAKER,I x 2OA-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR
SE
1 UTEVICEi7PEANER...MIN. 125A BUS C�
1:12 1 i I 482D 1 TOE LIT T PH,120/24OV.200A 121�RL�EC
1 12 1 1 1 TBD I TBD I GROUNDING ELECTRODE UFER I BLDR.EUFC
CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS
1)CONDITION OF USE(COU): CAMPACITY -TEMP. DERATE FILL DERATE)vs.REO'D(]MAX) ITEM UNIT PANEL
2)TERMINALS(TERM): AMPACITY AT TERMINALS. REG-D.(IMAX- 1.25) PANEL MFR. CUTLER-HAMMER
KEY SIZE CUfAL INSUI-ATION CALC. AMPACITY WO TEMP, FILL RESULT REO'D GCD BUS RATING AMPS 200
TYPE DERATES DERATE DERATE (A) (A) USED(A) F4AIN DISCONNECT AMPS 200
A #12 CU TFIWN-2 COU 30 0.76 1 10 22.80 10.80 ALLOWED PV PER NEC AMPS 40
TERM 25 25 13.50 20 PV GO D DEVICE USED AMPS 20
IF— #10 cu NM-B COU 40 0.91 1.0 36.40 10.80
TERM 35 35 13.50 20
#10 cu NM-B COU 40 0.91 110 36.40 10.80
TERM 35 35 13.50 20
CONDUCTOR SCHEDULE
K Y CONDUCTORS CU/AL 1 TYPE LOCATION TRADE
L#IK.ENGAGE CABLE, -*6C,FREE AIR I cu -ER SOLAR 5 6 11
I TC JARRAY
B 3_#JO'1-#10 ±Gc I cu NM-B IROMEX) I INTERIOR I SOLAR
C 1 3410,1410 EGO I CU NM-B(ROMEX) I INTERIOR ISOLAR
D I CAT5E.ETHERNET CABLE I cu I CATSE I INTERIOR I SOLAR
SEE NOTE 15
15AIIP
2GA/2P
A G G —=IN
_T10
ROOF EXTERIOR-GARAGE
ELECTRICAL DIAGRAM 3.18 KW
LOT#116
ORIGINAL BY: BRI MORRIS DATE:] .11-2
MENIFEE HILLS LENNAR; REVIEWED BY:JIMMY METER I DATE:15.11.30
980 MONITECITO DRIVE,#302
CORONA.CA 92879 REV.# By DATE I DESCRIPTION
�nannast;6
DWG TITLE: PAGE#: SCALE: SITE LOCATION:
4571 Bmd�y Str"t
INDIVIDUAL 29300 ASELIA GLEN STREET CO SM04
PLOT PLAN 2 NTS MENIFEE,CA 303."7.0300
ELECTRICAL I
STRUCTURAL NOTES-
SOLAR CONTRACTOR-
1)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48"D.C.
2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE.
3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT.
4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS, IT WILL BE FLASHED AND SEALED.
5)PV ARRAY WILL BE A MINIMUM OF 3*ABOVE THE COMPOSITE SHINGLE ROOF SURFACE.
6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION ARTMI
MANUAL,VERSION 227.3,PUB tA0113-ICC,JANUARY 2014.
7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(11 SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND THE EDGE
OF THE PV ARRAY I SUB-ARRAY.
8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'.
ROOFING CONTRACTOR-
1)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3m.
2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE
APROVED PRIOR TO PV SYSTEM INSTALLATION.
3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT W)OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE.DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO
BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS.
4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. lei
5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS.
6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE.BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO eapem
INSTALLATION. deral,st
1 p ans musi
ELECTRICAL NOTES:
GENERAL-
1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL).
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC.
3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC
WELD.
4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING.NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE
MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINTIFINISH AT PDINT OF CONTACT SHALL BE PROPERLY REMOVED.
5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE.
6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE.
SOLAR CONTRACTOR-
7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646, IEC61730.
8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS.
9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS.
10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM-
11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS,WIRING SHALL NOT MAKE CONTACT WITH THE
ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER.
12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122.
13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING.OR MANUFACTURER'S RECOMMENDATIONS.
14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT.
15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN 14ASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR.
SIGNAGE-
16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES.
17)ALL SAFETY MARKING I PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS.
18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT k.
19)ALL WIRING/RACEWAYS/UUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE,"OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'.
BUILDER ELECTRICAL AND SOLAR CONTRACTORS-
20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER.
21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26.
MENIFEE HILLS LENNAR; ORIGINAL BY: BRI MORRIS DATE:15.11.27
980 MONTECITO DRIVE.4302 REVIEWED BY:JIMMY METER DATE:15.11.30
CORONA,CA 92879 REV.# BY DATE DESCRIPTION '�Rncima=6
DWG TITLE: PAGE#: SCALE: SITE LOCATION: �71 B.ad..y S"M
INDIVIDUAL 29300 ABELIA GLEN STREET Boulder.CO W304
PLOT PLAN 3 NTS MENIFEE.CA 303,447.0300
NOTES I
CAUTION:
POWER TO THIS BUILDING IS SUPPLIED BY THE T
UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS
ARE LOCATED AS SHOWN.
or an
city
ept on the
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
1-877-SLR-POWR
PV POWER SOURCE - AC SPECS
AC OPERATING VOLTAGE: 240 V
AC OPERATING CURRENT: im A
NOTE: SEE MASTER SET FOR ADDIT10NAL PLACARD INFORMAT10N
MENIFEE HILLS LENNAR: ORIGINAL BY: BRI MORRIS DATE;15.11.27
980 MONTECITO DRIVE,#302 REVIEWED BY:JIMMY METER DATE:15.11.30
CORONA.CA 92879 REV.# BY DATE DESCRIPTION �n'amasr6
SOL.9
BWG TITLE: PAGE#- SCALE: SITE LOCATION: 4571 Broadway Street
INDIVIDUAL 29300 ABELIA GLEN STREET Boulder,CO 803M
P NTS MENIFEE,CA 303.447.0200
P�