PMT16-02974 City of Menifee Permit No.: PMT16-02974
29714 HAUN RD.
'qN-CCELA-> MENIFEE,CA 9258r, Type: Residential Electrical
0—A S'�k— MENIFEE Date Issued: 09109/2016
P E R M I T
SiteAddress: 29723 ARGYLE CIR, MENIFEE, CA 92584 Parcel Number: 364-370-031
Construction Cost: $8,331.60
Existing Use: Proposed Use:
Description of SOLAR TR 3D422-3 CAMELLIA
Work: 12 MODULES,3.18KW
LOT 120
Owner Contractor
LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC
980 MONTECITO DR#302 25 ENTERPRISE
CORONA,CA 92879 ALISO VIEJO, CA 92656
Applicant Phone:9493498269
JEREMIAH ACAYTURRI License Number.728102
LENNAR HOMES OF CALIFORNIA INC
25 ENTERPRISE
ALISO VIEJO, CA 92656
Fee Description Qtv Amount($
Solar, Residential or Small Commercial 1 252.00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 2.00
General Plan Maintenance Fee-Electrical 1 12.60
$294.60
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing bulliding operations being carried on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_8Idg_Perm1t-Terrp1ate.rpt Page 1 of 1
BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION
v
5"Menifee
DATE 08131/2016 PERMIT/PLAN CHECK NUMBER COo-1-1 14
TYPE: [:]COMMERCIAL []RESIDENTIAL [-]MULTI-FAMILY [JMOBILEHOME E]POOL/SPA []SIGN
SUBTYPE: E]ADDITION []ALTERATION DDEMOLITION F]ELECTRICAL DMECHANICAL
ZNEWE]PLUMBING [-]RE-ROOF-NUMBER OF SQUARES
DESCRIPTION OF WORK Solar Permit-Plan 2785-3.18KW/12 PCS
rNa4er Pffi-n,4 4+-
PROJ ECTADDRESS 29723 Argyle Circle
A S SSO
SE R'SPARCELNUMBER LOT 120 TRAC-r 30422-3
PROPERTY OWNER'S NAME Lerner Homes of California, Inc.
ADDRESS 980 Montecito Dr.Suite 302, Corona, CA 92879
PHONE (951)817-3680 EMAIL jeremiah.acayturH@Iennar.com
APPLICANTNAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr., Suite 302, Corona,CAS2879
PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com
CONTRACTOR'S NAME Lennar Homes of California, Inc., OWNERBUILDER? ZYES[:]NO
BUSINESSNAME Lennar Homes of California, Inc.
ADDRESS 980 Mantecito Dr.,Suite 302, Corona. CA
PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com
CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B
VALUATION$ $8.331.60 L SQ FT
APPLICANT'S SIGNATURE �1 , DATE 'EI/31/2016
OTYSTAFFU5EONLY
DEPARTMENT DISTRIBUTIUN 6D I Oily UF MLNIFEE BUSINESS LICENSE NUMBER
BUILDING PLANNING ENGINEERING FIRE � GREEN SMIP
INVOICE
AMOUNT PAIDAMOUNT OCASH OCHECK# 0 CREDIT CARD VISA/MC
PLAN CHECK FEES PAIDAMOUNT 0 CASH 0 CHECK# 0CREDflFCARD VISA/MC
OWNER BUILDER VERIFIED OYES 0 NO DL NUMBER NOTARIZED LETTER 0 YES 0 NO
City of Menifee Building&Safety Deportment 29714 Haun Rd. Menifee, CA 92586 951-672-6777
www.cityofmenifee.us Inspection Request Line 951-246-6213
SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED
ITEM CITY MFR. 1 MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE
SYSTEM SIZE 3.18 KW I LOCATIONS INDICATED BY THE ILLUSTRATION.
MODULE 12 PCS.1 HYUNDAI I HiS-S265RG (265W) BUYER:
INVERTER 12 PCS.1 ENPHASE I M215-60-2LL-S22-IG
ROOF TYPE TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE:
SUB-ARRAY INFORMATION
OF MENIFEE
I ARRAY#1 ARRAY*2 ARRAY#3
MOD OTY 1 12 N NA BUYER: TAINIGAND S1
TILT .3. A' NA-
AZIMUTH 1 90- NA' NA' DATE:
City of Menifee r K C, �j E D SCZ
Building Dept
SEP 0 7 2P'j a'of these plans shall i
0 4 of,any violation of an
-ii.itAnsand ordinances. Tf
.1, 8. t Reeeiv !iu Until completion.
6
r�\\,\\\N\111
4111111111111111,
---__.SOLADECK WIRE
TRANSITION BOX
(UNDER ARRAY)
PV AC DISCONNECT
-�EXTERIOR-GARAGE
———————— UTILITY METER 5 JM
}-�MAIN SERVICE PANEL
(VERIFIED BY BUILDER)
NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF
Z4)
PLAN 2785 ELEVATION A-REVERSE
ORIENTATION 2 LOT# 120
LENNAR; ORIGINAL BY: KIM ABCOUWER DATE:16.06.09
CAMELLIA AT 980 MONTECITO DRIVE,#302 REVIEWED B .SHAUN MARUNA I DATE:16.06.10
THE LAKES CORONA.CA 92879 REV.# BY DATE DESCRIPTION masbd
S.it ..L�R
DWG TITLE: PAGE#; SCALE: SITE LOCATION: — 4571 BroadmyStreel
INDIVIDUAL 29723 ARGYLE CIRCLE Boulder,CO 80304
PLOT PLAN 1 1/16*= P-O' MENIFEE,CA 303.447.0300
SYSTEM LAYOUT
MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS
ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL
LOCATION MENIFEE.CA INV. MAKE INVERTER SPEC ENPHASE
TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% 'C 37 INV. MODEL INVERTER SPEC M215-60-2LL-S22-IG
TEMP,AMBIENT LOW(TMIN) ASHRAE EXTR.MIN 'C -2 INV. MAX POWER.(WAC MAX) INVERTER SPEC WATTS JAC) 225
TEMP,MODULE TEST(TTBT) MODULE SPEC C 25 INV. INPUT V,(Voc MAX) INVERTER SPEC VOLTS(DO 48
TEMP,DELTA LOW(TDELTA) TmiN-TMT C -27 INV. OUTPUT V.(VAc NOM) INVERTER SPEC VOLTS(AC) 240
MOD. MANUFACTURER MODULE SPEC HYUNDAI INV. OUTPUT FREQUENCY INVERTER SPEC HERTZ 60
MOD. PART NUMBER MODULE SPEC HiS-S265RG INV. OUTPUT CURRENT.JAC INVERTER SPEC AMPS JAC) 0.9
MOD. POWER STC(P) MODULE SPEC WATTS(DO 265 INV. PHASE GLIA14TITY INVERTER SPEC PHASE I
MOD. POWER PTC MODULE SPEC WATTS(DO 238 COMPLIANCE INVERTER SPEC UL1741/IEEE]547
MOD. OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(cc) 1 31.30 INV. GROUNDING 1 :NVERTER SPEC 1 QTY SOLATED
MOD. OPEN CCT. VOLTAGE(VOC) MODULE SPEC VOLTS(cc) 38.10 INV. OTY, MAX/BRANCH CCT. V.OTY
MOD- COEFF. VOLT/TEMP(COEF) MODULE SPEC V/-C -0.114 BRANCH CCT. OUTPLJr,IMAXBC I (IAC*INV.OTYac) I AMPS(At) 1 10-80
MOD. MAX VOLTAGE(VMAMOD) (VOC+(TD-COEF)) VOLTS(m) 41.18 INV. OUANTITY,TOTAL I INV.OTYT I OTY 12
MOD.OPERATING CURRENT(IMP) MODULE SPEC AMPS(00 8.50 TOTAL SYSTEM OUTPUT.IMAXTS I (IAC-INV.GTYT) I AMPS JAC) KL80
MOD. SHORT CCT. CURRENT(Isc) MODULE SPEC AMPS(M) 9.00
MOD. MAXIMUM CURRENT(IMAX) (Isc- 1.25) AMPS(DC) 11.25
MIN. AMPACITY REO-D.PER 14EC (IMAX- 1.25) AMPS(13C) 14.06
SERIES FUSE RATING.MAX MODULE SPEC AMPS(13c) 15 -()1 st
ELECTRICAL EQUIPMENT SCHEDULE
KEY QTY MANUFACTURER MODEL NOTES TRADE M.Ja is
1 12 HYUNDAI HiS-S265RG (265W) PV MODULE SOLAR I of a 3p
2 12 ENPHASE M215-60-2LL-S22-IG PVINVERTER SOLAR
3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 311 SOLAR
1. 1 CUTLER-HAMMER DG22IURB PV AC DISCONNECT,NEMA 3R, 240V.30A SOLAR
5 1 ENPHASE ENVOY PV DATA MONITOR, 120V SOLAR
6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR
7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR
8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS;I x 15A-IP(ENVOY) SOLAR
9 NOTE CUTLER-HAMMER TBD P�8REAKER,,IX IOA-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR
�EFVJE PAN
10 1 1 TBD 1 T80 .MIN- 125A BUS BLDR. ELEC.
11 1 TBD TBD I UTILITY METER,IPH, 120/24OV.200A BLDR. EILEC.
12 1 TBD TBD I GROUNDING ELECTRODE UFER BLDR. ELEC.
CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULAT11ONS
1)CONDITION OF USE(COU); I AMPACITY* TEMP. DERATE - FILL DERATE) vs- REG'D(IMAX) ITEM UNIT PANEL
2)TERMINALS(TERM: I AMPACITY AT TERMINALS. vs. REDID,(IMAX' 1.25) PANEL MFR. CUTLER-HAMMER
KEY SIZE CU/AL INSULATION CALC. AMPACITY W10 TEMP� IFILL RESULT RED'D OCD BUS RATING AMPS 200
TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200
A #12 CU THWN-2 COU 30 0.76 1.0 22.80 10.80 - ALLOWED PV PER NEC AMPS 40
TERM 25 25 13.50 20 PV OCPD DEVIC
a #10 CU NM-B COU 40 0.91 1.0 36.40 10.80
TERM 35 35 13.50 20
C #10 CU wM_B COU 40 0.91 1.0 36.40 10.80
TERM 35 35 13.50 20
CONDUCTOR SCHEDULE
CU/AL TYPE 1 LOCATION I TRADE
A 1-#12 ENGAGE CABLE, 1-#6G,FREE AIR CU li TC-ER 11 ARRNY I SOLAR I
B I J�10, 1-#10 EGC CU I NM-B(ROMEX) I INTERIOR ISOLAR
C 1 3-#10. 1-#10 EGC I CU I NM-B (ROMEX) 1 11 ERIOR I SOLAR
D I CAT5E. ETHERNET CA13LE I CU I CAT5E I II E
SEE NOTE 15
Ismip
A 22
L N
a 1 12
ROOF EXTERIOR-GARAGE
ELECTRICAL DIAGRAM 3-18 KIN
LOT# 120
CAMELLIA AT LENNAR; ORIGINAL BY: KIM ABCOUNER DATE:16.06.09
980 MONTECITO DRIVE,#302 REVIEWED BY:SHAUN MARUNA DATE:16.06.10
THE LAKES CORONA.CA 9ZB79 REV.# -BY DATE DESCRIPTION masrd
SOLAR
DWG TITLE: PAGE SCALE: SITE LOCATION: 4571 Broad,%;ayStreet
INDIVIDUAL 29723 ARGYLE CIRCLE Boulder,CO W304
PLOT PLAN 2 NITS MENIFEE.CA 303.447.0300
ELECTRICAL I
STRUCTURAL NOTES:
SOLAR CONTRACTOR-
1)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'D.C.
2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE.
3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT.
4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS- IT WILL BE FLASHED AND SEALED.
5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE.
6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION
MANUAL.VERSION 227.3.PUB 140113-ICC,JANUARY 2014.
7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH (I-)SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND THE EDGEDARTIAE
OF THE PV ARRAY/SUB-ARRAY.
8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'.
ROOFING CONTRACTOR-
1)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3--
2)26 GAUGE INTERLOCKING FLASHING 'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE
APROVED PRIOR TO PV SYSTEM INSTALLATION. A
3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT 00 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE.DOWN TO THE ROOF EAVE. PEEL-N-STICK BASE
BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. "N
4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE.
5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS.
6)BIROSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR To
INSTALLATION.
i be a I enT
te federa 1,st
d p:ans I iuM
ELECTRICAL NOTES:
GENERAL-
1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NI
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC.
3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC
WELD.
4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING.NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE
MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED.
5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE-
6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE.
SOLAR CONTRACTOR-
7)MODULE CERTIFICATIONS WILL INCLUDE ULII [EC61646,IEC61730.
8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS.
9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS.
10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W1 ENPHASE MICRO-INVERTER SYSTEM.
11)MODLLE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS. WIRING SHALL NOT MAKE CONTACT WITH THE
ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER.
12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122.
13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING.OR MANUFACTURER'S RECOMMENDATIONS.
14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT.
15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR.
SIGNAGE-
16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES.
17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS.
18)MARKING I PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT a,
19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE.-OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'.
BUILDER ELECTRICAL AND SOLAR CONTRACTORS-
20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER.
21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26.
LENNAR: ORIGINAL BY: KIM ABCOUWER DATE:16.06.09
CAMELLIA AT 980 MONTECITO DRIVE.#302 REVIEWED B SHAUN MARUNA I DATE:16.06.10
THE LAKES CORONA,CA 92879 REV.* BY DATE DESCRIPTION ItMmastd
�.L�.
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 BroadwayStreet
INDIVIDUAL 29723 ARGYLE CIRCLE Boulder,CC 80304
PLOT PLAN 3 NTS 303,447.0300
NOTES MENIFEE,CA
CAUTION:
POWER TO THIS BUILDING IS SUPPLIED BY THE T
UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS
ARE LOCATED AS SHOWN.
Illisc
DATE
or an
city
apt on the
SOLADECK WIRE
----�TRANSITION BOX
(UNDER ARRAY)
PV AC DISCONNECT
EXTERIOR-GARAGE
UTILITY METER 8
]-�MAIN SERVICE PANEL
(VERIFIED BY BUILDER)
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
1-877-SLR-POWR
PV POWER SOURCE - AC SPECS
AC OPERATING VOLTAGE: 240 V
AC OPERATING CURRENT: 10.8 A
NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION
CAMELLIA AT LENNAR: ORIGINAL BY: KIM ABCOUWER 12ATE:16.06.09
980 MONTECITO DRIVE, #302 REVIEWED BY:SHAUN MARUNA DATE 16 06 10
THE LAKES CORONA,CA 92879 REVa# BY DATE I DESCRIPTIOt ianamast;6
$MAP
DWG TITLE PAGE #: I SCALE: SITE LOCATION: 4571 BrcadmySt�t
INDIVIDUAL 29723 ARGYLE CIRCLE Bould.,,CO 80304
PLOT PLAN 4 NTS MENIFEE.CA 303.447.0300
PLACARDS I I