Loading...
PMT16-02974 City of Menifee Permit No.: PMT16-02974 29714 HAUN RD. 'qN-CCELA-> MENIFEE,CA 9258r, Type: Residential Electrical 0—A S'�k— MENIFEE Date Issued: 09109/2016 P E R M I T SiteAddress: 29723 ARGYLE CIR, MENIFEE, CA 92584 Parcel Number: 364-370-031 Construction Cost: $8,331.60 Existing Use: Proposed Use: Description of SOLAR TR 3D422-3 CAMELLIA Work: 12 MODULES,3.18KW LOT 120 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA,CA 92879 ALISO VIEJO, CA 92656 Applicant Phone:9493498269 JEREMIAH ACAYTURRI License Number.728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ALISO VIEJO, CA 92656 Fee Description Qtv Amount($ Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 2.00 General Plan Maintenance Fee-Electrical 1 12.60 $294.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing bulliding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_8Idg_Perm1t-Terrp1ate.rpt Page 1 of 1 BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION v 5"Menifee DATE 08131/2016 PERMIT/PLAN CHECK NUMBER COo-1-1 14 TYPE: [:]COMMERCIAL []RESIDENTIAL [-]MULTI-FAMILY [JMOBILEHOME E]POOL/SPA []SIGN SUBTYPE: E]ADDITION []ALTERATION DDEMOLITION F]ELECTRICAL DMECHANICAL ZNEWE]PLUMBING [-]RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit-Plan 2785-3.18KW/12 PCS rNa4er Pffi-n,4 4+- PROJ ECTADDRESS 29723 Argyle Circle A S SSO SE R'SPARCELNUMBER LOT 120 TRAC-r 30422-3 PROPERTY OWNER'S NAME Lerner Homes of California, Inc. ADDRESS 980 Montecito Dr.Suite 302, Corona, CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturH@Iennar.com APPLICANTNAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona,CAS2879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc., OWNERBUILDER? ZYES[:]NO BUSINESSNAME Lennar Homes of California, Inc. ADDRESS 980 Mantecito Dr.,Suite 302, Corona. CA PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ $8.331.60 L SQ FT APPLICANT'S SIGNATURE �1 , DATE 'EI/31/2016 OTYSTAFFU5EONLY DEPARTMENT DISTRIBUTIUN 6D I Oily UF MLNIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE � GREEN SMIP INVOICE AMOUNT PAIDAMOUNT OCASH OCHECK# 0 CREDIT CARD VISA/MC PLAN CHECK FEES PAIDAMOUNT 0 CASH 0 CHECK# 0CREDflFCARD VISA/MC OWNER BUILDER VERIFIED OYES 0 NO DL NUMBER NOTARIZED LETTER 0 YES 0 NO City of Menifee Building&Safety Deportment 29714 Haun Rd. Menifee, CA 92586 951-672-6777 www.cityofmenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM CITY MFR. 1 MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 3.18 KW I LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 12 PCS.1 HYUNDAI I HiS-S265RG (265W) BUYER: INVERTER 12 PCS.1 ENPHASE I M215-60-2LL-S22-IG ROOF TYPE TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: SUB-ARRAY INFORMATION OF MENIFEE I ARRAY#1 ARRAY*2 ARRAY#3 MOD OTY 1 12 N NA BUYER: TAINIGAND S1 TILT .3. A' NA- AZIMUTH 1 90- NA' NA' DATE: City of Menifee r K C, �j E D SCZ Building Dept SEP 0 7 2P'j a'of these plans shall i 0 4 of,any violation of an -ii.itAnsand ordinances. Tf .1, 8. t Reeeiv !iu Until completion. 6 r�\\,\\\N\111 4111111111111111, ---__.SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT -�EXTERIOR-GARAGE ———————— UTILITY METER 5 JM }-�MAIN SERVICE PANEL (VERIFIED BY BUILDER) NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF Z4) PLAN 2785 ELEVATION A-REVERSE ORIENTATION 2 LOT# 120 LENNAR; ORIGINAL BY: KIM ABCOUWER DATE:16.06.09 CAMELLIA AT 980 MONTECITO DRIVE,#302 REVIEWED B .SHAUN MARUNA I DATE:16.06.10 THE LAKES CORONA.CA 92879 REV.# BY DATE DESCRIPTION masbd S.it ..L�R DWG TITLE: PAGE#; SCALE: SITE LOCATION: — 4571 BroadmyStreel INDIVIDUAL 29723 ARGYLE CIRCLE Boulder,CO 80304 PLOT PLAN 1 1/16*= P-O' MENIFEE,CA 303.447.0300 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE.CA INV. MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% 'C 37 INV. MODEL INVERTER SPEC M215-60-2LL-S22-IG TEMP,AMBIENT LOW(TMIN) ASHRAE EXTR.MIN 'C -2 INV. MAX POWER.(WAC MAX) INVERTER SPEC WATTS JAC) 225 TEMP,MODULE TEST(TTBT) MODULE SPEC C 25 INV. INPUT V,(Voc MAX) INVERTER SPEC VOLTS(DO 48 TEMP,DELTA LOW(TDELTA) TmiN-TMT C -27 INV. OUTPUT V.(VAc NOM) INVERTER SPEC VOLTS(AC) 240 MOD. MANUFACTURER MODULE SPEC HYUNDAI INV. OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD. PART NUMBER MODULE SPEC HiS-S265RG INV. OUTPUT CURRENT.JAC INVERTER SPEC AMPS JAC) 0.9 MOD. POWER STC(P) MODULE SPEC WATTS(DO 265 INV. PHASE GLIA14TITY INVERTER SPEC PHASE I MOD. POWER PTC MODULE SPEC WATTS(DO 238 COMPLIANCE INVERTER SPEC UL1741/IEEE]547 MOD. OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(cc) 1 31.30 INV. GROUNDING 1 :NVERTER SPEC 1 QTY SOLATED MOD. OPEN CCT. VOLTAGE(VOC) MODULE SPEC VOLTS(cc) 38.10 INV. OTY, MAX/BRANCH CCT. V.OTY MOD- COEFF. VOLT/TEMP(COEF) MODULE SPEC V/-C -0.114 BRANCH CCT. OUTPLJr,IMAXBC I (IAC*INV.OTYac) I AMPS(At) 1 10-80 MOD. MAX VOLTAGE(VMAMOD) (VOC+(TD-COEF)) VOLTS(m) 41.18 INV. OUANTITY,TOTAL I INV.OTYT I OTY 12 MOD.OPERATING CURRENT(IMP) MODULE SPEC AMPS(00 8.50 TOTAL SYSTEM OUTPUT.IMAXTS I (IAC-INV.GTYT) I AMPS JAC) KL80 MOD. SHORT CCT. CURRENT(Isc) MODULE SPEC AMPS(M) 9.00 MOD. MAXIMUM CURRENT(IMAX) (Isc- 1.25) AMPS(DC) 11.25 MIN. AMPACITY REO-D.PER 14EC (IMAX- 1.25) AMPS(13C) 14.06 SERIES FUSE RATING.MAX MODULE SPEC AMPS(13c) 15 -()1 st ELECTRICAL EQUIPMENT SCHEDULE KEY QTY MANUFACTURER MODEL NOTES TRADE M.Ja is 1 12 HYUNDAI HiS-S265RG (265W) PV MODULE SOLAR I of a 3p 2 12 ENPHASE M215-60-2LL-S22-IG PVINVERTER SOLAR 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 311 SOLAR 1. 1 CUTLER-HAMMER DG22IURB PV AC DISCONNECT,NEMA 3R, 240V.30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR, 120V SOLAR 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR 8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS;I x 15A-IP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBD P�8REAKER,,IX IOA-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR �EFVJE PAN 10 1 1 TBD 1 T80 .MIN- 125A BUS BLDR. ELEC. 11 1 TBD TBD I UTILITY METER,IPH, 120/24OV.200A BLDR. EILEC. 12 1 TBD TBD I GROUNDING ELECTRODE UFER BLDR. ELEC. CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULAT11ONS 1)CONDITION OF USE(COU); I AMPACITY* TEMP. DERATE - FILL DERATE) vs- REG'D(IMAX) ITEM UNIT PANEL 2)TERMINALS(TERM: I AMPACITY AT TERMINALS. vs. REDID,(IMAX' 1.25) PANEL MFR. CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALC. AMPACITY W10 TEMP� IFILL RESULT RED'D OCD BUS RATING AMPS 200 TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 A #12 CU THWN-2 COU 30 0.76 1.0 22.80 10.80 - ALLOWED PV PER NEC AMPS 40 TERM 25 25 13.50 20 PV OCPD DEVIC a #10 CU NM-B COU 40 0.91 1.0 36.40 10.80 TERM 35 35 13.50 20 C #10 CU wM_B COU 40 0.91 1.0 36.40 10.80 TERM 35 35 13.50 20 CONDUCTOR SCHEDULE CU/AL TYPE 1 LOCATION I TRADE A 1-#12 ENGAGE CABLE, 1-#6G,FREE AIR CU li TC-ER 11 ARRNY I SOLAR I B I J�10, 1-#10 EGC CU I NM-B(ROMEX) I INTERIOR ISOLAR C 1 3-#10. 1-#10 EGC I CU I NM-B (ROMEX) 1 11 ERIOR I SOLAR D I CAT5E. ETHERNET CA13LE I CU I CAT5E I II E SEE NOTE 15 Ismip A 22 L N a 1 12 ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 3-18 KIN LOT# 120 CAMELLIA AT LENNAR; ORIGINAL BY: KIM ABCOUNER DATE:16.06.09 980 MONTECITO DRIVE,#302 REVIEWED BY:SHAUN MARUNA DATE:16.06.10 THE LAKES CORONA.CA 9ZB79 REV.# -BY DATE DESCRIPTION masrd SOLAR DWG TITLE: PAGE SCALE: SITE LOCATION: 4571 Broad,%;ayStreet INDIVIDUAL 29723 ARGYLE CIRCLE Boulder,CO W304 PLOT PLAN 2 NITS MENIFEE.CA 303.447.0300 ELECTRICAL I STRUCTURAL NOTES: SOLAR CONTRACTOR- 1)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'D.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS- IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL.VERSION 227.3.PUB 140113-ICC,JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH (I-)SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND THE EDGEDARTIAE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. ROOFING CONTRACTOR- 1)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3-- 2)26 GAUGE INTERLOCKING FLASHING 'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. A 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT 00 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE.DOWN TO THE ROOF EAVE. PEEL-N-STICK BASE BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. "N 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 6)BIROSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR To INSTALLATION. i be a I enT te federa 1,st d p:ans I iuM ELECTRICAL NOTES: GENERAL- 1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NI 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING.NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE- 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE ULII [EC61646,IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W1 ENPHASE MICRO-INVERTER SYSTEM. 11)MODLLE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS. WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING.OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING I PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT a, 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE.-OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. LENNAR: ORIGINAL BY: KIM ABCOUWER DATE:16.06.09 CAMELLIA AT 980 MONTECITO DRIVE.#302 REVIEWED B SHAUN MARUNA I DATE:16.06.10 THE LAKES CORONA,CA 92879 REV.* BY DATE DESCRIPTION ItMmastd �.L�. DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 BroadwayStreet INDIVIDUAL 29723 ARGYLE CIRCLE Boulder,CC 80304 PLOT PLAN 3 NTS 303,447.0300 NOTES MENIFEE,CA CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE T UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. Illisc DATE or an city apt on the SOLADECK WIRE ----�TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER 8 ]-�MAIN SERVICE PANEL (VERIFIED BY BUILDER) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: 10.8 A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION CAMELLIA AT LENNAR: ORIGINAL BY: KIM ABCOUWER 12ATE:16.06.09 980 MONTECITO DRIVE, #302 REVIEWED BY:SHAUN MARUNA DATE 16 06 10 THE LAKES CORONA,CA 92879 REVa# BY DATE I DESCRIPTIOt ianamast;6 $MAP DWG TITLE PAGE #: I SCALE: SITE LOCATION: 4571 BrcadmySt�t INDIVIDUAL 29723 ARGYLE CIRCLE Bould.,,CO 80304 PLOT PLAN 4 NTS MENIFEE.CA 303.447.0300 PLACARDS I I