PMT16-02972 City of Menifee Permit No.: PMT16-02972
29714 HAUN RD. Type: Residential Electrical
<A-CCELA—> MENIFEE, CA 92586
MENIFEE Date Issued: 09/09120116
P E R M I T
Site Address: 29741 ARGYLE CIR, MENIFEE, CA 92584 Parcel Number: 364-370-029
Construction Cost: $7,650.40
Existing Use: Proposed Use:
Description of SOLAR TR 30422-3 CAMELLIA
Work: 11 MODULES,2.92KW
LOT 118
Owner Contractor
LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC
980 MONTECITO DR#302 25 ENTERPRISE
CORONA,CA 92879 ALISO VIEJO, CA 92656
Applicant Phone:9493498269
JEREMIAH ACAYTURRI License Number: 728102
LENNAR HOMES OF CALIFORNIA INC
25 ENTERPRISE
ALSO VIEJO, CA 92656
Fee Description Qtv Amount($1
Solar, Residential or Small Commercial 1 25Z00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 1.00
General Plan Maintenance Fee-Electrical 1 12.60
$293.60
The issuance of this penrnit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing bulliding operations being carried on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise slated,a pernrit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA Bidg_Pennit-Template.rPt Page I of 1
BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION
T"Menifee
DATE 08/3112016 PERMIT/PLAN CHECK NUMBER TI-00"
TYPE: [:]COMMERCIAL F]RESIDENTIAL E]MULTI-FAMILY OM0131LEHOME F]POOL/SPA [-]SIGN
SUBTYPE: F]ADDITION []ALTERATION [-]DEMOLITION F]ELECTRICAL [-]MECHANICAL
ZNEW OPLUMBING E]RE-ROOF-NUMBER OF SQUARES
DESCRIPTION OF WORK Solar Permit-Plan 2399-2.92KW/11 PCS
M(-14e)r ngmt� #
PROJECTADDRESS 29741 Argyle Circle
ASSESSOR'S PARCEL NUMBER 570—OZ(7 LOT 118 TRACT 30422-3
PROPERTY OWNER'S NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr.Suite 302,Corona, CA 92879
PHONE (951)817-3680 EMAIL jeremiah.arayturri@lennar.Gom
APPLICANITNIAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr., Suite 302,Corona,CA 92879
PHONE (951)817-3680 EMAIL jeremiah.ar-ayturri@lennar.com
CONTRACTOR'S NAME Lennar Homes of California, Inc., OWNERBUILDER? ZYESONO
BUSINESSNAME Lennar Homes of California, Inc.
ADDRESS 980 Montedto Dr.,Suite 302, Corona. CA
PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com
CONTRACrOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B
VALUATION$ $7,650.40 Q-F-T� LSQFT
APPLICANT'S SIGNATURE DATE 08/31/2016
DEPARTMENT DISTRIBUTION FI-R-E � GREEN SMIP CITY OF MENIFEE BUSINESS LICENSE NUMBER
BUILDING PLANNING ENGINEERINGL
INVOICE I Aq�5.(
AMOU T P PAIDAMOUNT 0 CASH 0 CHECK# OCREDITCARD VISA/MC
PLAN CHECK FEES PAIDAMOUNT OCASH OCHECK# OCREDITCARD VISA/MC
,FOWNER BUILDER VERIFIED 0 YES 0 NO CIL NUMBER NOTARIZED LETTER 0 YES 0 NO
City of Menifee Building&Safety Department 29714 Houn Rd. Menifee, CA 92586 951-672-6777
www.citVefirnenifee.us Inspection Request Line 951-246-6213
SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED
ITEM I QTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE
SYSTEM SIZE 1 2.9?XW LOCATIONS INDICATED BY THE ILLUSTRATION.
FORDULE 11 PCS. HYUNDAI I HiS-S265RG (265W) BUYER:
INVERTER 11 PCS.1 ENPHASE I M215-60-2LL-S22-IG
ROOF TYPE TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE:
SUB-ARRAY INFORMATION
1 ARRAY#1 ARRAY#2 ARRAY*3 MENIFE
NA BUYER: - AND
ME Dry 21- F33- WA—'
TILT
AZIMUTH 1 230- 1 320- NA' DATE:
APPTMA
city ot Menifee REVIVWED
Building Dept
SEP 0 7 201i i..:,rroval ofthose plans sh
;ippf oval of,any violation o
f1latilations and ordinances
Rece i v U 13'-Z'ARRAY
4' 5'-5' 14'FLASHING 3' ;oosite until completion.
--- ---------- --
TOO
PV AC DISCONNECT
EXTERIOR-GARAGE
UTILITY METER a
MAIN SERVICE PANEL
(VERIFIED BY BUILDER) SOLADECK WIRE 0
TRANSITION BOX
(UNDER ARRAY) Ill
M9
NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF
PLAN 2399 ELEVATION C
ORIENTATION I LOT*118
ORIGINAL BY: KIM ASCOUINER DATE:16-06.09
CAMELLIA AT LENNAR; REVIEWED BY:SHAUN MARUNA DATE:16.06-10
980 MONTECITO DRIVE,#302
THE LAKES CORONA.CA 92879 REV.# BY DATE D SCRIPTION rnast;6
na
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street
INDI D 29741 ARGYLE CIRCLE Boulder,CO 80304
PL TVII 1/16'=1'-0' MENIFEE,CA 303.447.0300
MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS
ITEM NOTE/CALC UNIT DETAIL ITEM NOTE /CALC UNIT DETAIL
LOCATION MENIFEE,CA INV. MAKE INVERTER SPEC ENPHASE
TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% 'C 37 INV. MODEL INVERTER SPEC MZIS-60-2LL-S22-IG
TEMP.AMBIENT LOW(TMIN) ASHRAE EXTR,MIN 'C -2 INV. MAX POWER,(WAC MAX) INVERTER SPEC WATTS(AC) 225
TEMP.MODULE TEST(TTEST) MODULE SPEC c 25 INV. INPUT V, (Vac MAX) INVERTER SPEC VOLTS 00 48
TEMP,DELTA LOW(TOELTA) TMIN-TTEST 'C -27 INV. OUTPUT V.(VAc NOM) INVERTER SPEC VOLTS(AC) 240
MOD. MANUFACTURER MODULE SPEC HYUNDAI INV. OUTPUT FREQUENCY INVERTER SPEC HERTZ 60
MOD. PART NUMBER MODULE SPEC HiS-SZ65RG INV. OUTPUT CURRENT, IAC INVERTER SPEC_ AMPS(AC) 0.9
MOD. POWER STC(P) MODULE SPEC WATTS 00 265 INV. PHASE QUANTITY INVERTER SPEC PHASE I frL I I LFE
MOD. POWER PTC MODULE SPEC WATTS 00 238 COMPLIANCE INVERTER SPEC UL1741/lEEE1547
MOD. OPERATING VOLTAGE(Vmp) MODULE SPEC VOLTS O)C) 1 31.30 INV. GROUNDING INVERTER SPEC ISOLATED
MOD. OPEN CCT. VOLTAGE(Voc) MODULE SPEC VOLTS(DO 38.10 INV. OTY,MAX/BRANCH CCT. INV.QTYBc OTY 11
MOD. COEFF. VOLT/TEMP(COEF) MODULE SPEC V/-C -0.114 BRANCH CCT. OUTPUT, IIIAXBC (IAC-INV.QTYBC) AMPS(AC) 9.90
MOD. MAX VOLTAGE (VHAMOD) (VOC+(TD*C0EFn VOLTS(Dc) 41.18 INV. QUANTITY,TOTAL INV.OTYT OTY 11 111,-
MOD. OPERATING CURRENT(Imp) MODULE SPEC AMPS 00 8.50 TOTAL SYSTEM OUTPUT,IMAXTS (JAC-INV.QTYT) AMPS(AC) _2.9O__jffjjUMj
MOE). SHORT CCT.CURRENT(Isc) MODULE SPEC AMPS(nc) 9.00
MOD. MAXIMUM CURRENT(IMAX) (Isc" 1.25) AMPS(DC) 11.25
MIN.AMPACITY REO'D.PER NEC OMAX- 1-25) AMPS(DC) 14.06
I SERIES FUSE RATING,MAX MODULE SPEC AMPS(oc) 15
ELECTRICAL EQUIPMENT SCHEDULE fit be constUl
KEY QTY MANUFACTURER MODEL NOTES TRADE y provisions of
I it HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR
2 11 ENPHASE M215-60-2LL-S22-IG PVINVERTER SOLAR -is set of apl rO
3 2 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR
4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT.NEMA 3R,24OV,30A SOLAR
5 1 ENPHASE ENVOY PV DATA MONITOR, 120V SOLAR
6 1 TBO TOD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR
7 1 TOD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR
8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS: I x SA-IP(ENVOY) SOLAR
9 NOTE CUTLER-HAMMER TBD PV BREAKER. I x 2OA-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR
1 10 1 1 TOD TBD 1 �tLVICEi�PEATNEERL,.MIN. 125A BUS 9�P2 '�
11 1 1 TOD I TBD UTIL17Y PH,1201240V.200A HIDR� Z.C!
12 1 1 TOD I TOD GROUNDING ELECTRODE UFER I BLDR. ELEC.
CONDUCTOR SIZING CALCULATIONS INTERCONNECTIO
1)CONDITION OF USE(COU): I (AMPACITY-TEMP. DERATE ' FILL DERATE)�L. REO'D(IMAX) ITEM UNIT PANEL
2)TERMINALS(TERM I AMPACITY AT TERMINALS. vs. REO'D.(IMAX- 1.25) PANEL MFR. CUTLER-HAMMER
KEY SIZE CLYAL INSULATION CALC. AMPACITY W10 TEMP� FILL RESULT REQ'D OCD BUS RATING AMPS 200
TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200
A #12 CU THWN-2 CCU 30 0-76 1.0 22.80 9.90 ALLOWED PV PER NEC AMPS 40
TERM 25 =25 12.38 20 FvGcPD DEVICE USED AMPS 20
a #10 CU NM-R COU 40 0.91 1.0 36.40 9.90
TERM 35 35 12.38 20
C #10 CU NM-B COU 40 0.91 1.0 36.40 9.90
35
TERM 35 35 12.38 20
CONDUCTOR SCHEDULE
I-
KEY CONDUCTORS I CUIAL 1 TYPE L TO IRADE
L §0��
CABLE, 1-#6G,FREE AIR CU I TC-ER 11' —A AY �R
B 3-#10, 1-#10 EGC I CU I NM-B OROMEX) I N RIO SOLAR
C 3-#10. 1410 EGC I CU I NM-B OROMEX)
D CAT5E.ETHERNET CABLE I CU I CAT5E I INTERIOR SOLAR
SEE NOTE 15 @
20AfZP
N
T G-------
i i a I I I
ROOF EXTERIOR GARAGE
KG
ELECTRICAL DIAGRAM 2.92 KW
LOT# 118
LENNAR: ORIGINAL BY: KIM ABCOUWER DATE:16.06.09
CAMELLIA AT 980 MONTECITO DRIVE,#302 REVIEWED BY:SHAUN MARUNA DATE:16.06.10
THE LAKES CORONA,CA 921379 REV.# BY DATE I DESCRIPTION mastd
DWG TITLE: SOLAR
PAGE SCALE: SITE LOCATION: 4571 BroadwaySueet
INDIVIDUAL 29741 ARGYLE CIRCLE Boulder,CO 80304
PLOT PLAN NTS MENIFEE, CA 303.447.0300
ELECTRICAL I
STRUCTURAL NOTES:
SOLAR CONTRACTOR-
1)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48*O.C.
2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE.
3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT.
4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED.
5)PV ARRAY WILL BE A MINIMUM OF 3"ABOVE THE COMPOSITE SHINGLE ROOF SURFACE.
6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION
MANUAL,VERSION 227.3,PUB 140113-ICC,JANUARY 2014. W VIII
7)UNtRAC TOP CLAMPS REQUIRE A ONE INCH W)SPACE BETWEEN PV MODULES. SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND THE EDGE
OF THE PV ARRAY I SUB-ARRAY.
8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'_
ROOFING CONTRACTOR
1)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3%
2)26 GAUGE 114TERLOCKING FLASHING 'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE
APROVED PRIOR TO PV SYSTEM INSTALLATION. I
3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(P)OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO
BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS.
4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY To THE ROOF EAVE.
5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS.
6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO 3e a pen
INSTALLATION. fedei d,s
ptans ma
ELECTRICAL NOTES-
GENERAL-
1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL).
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC.
3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC
WELD.
4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE
MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINTIFINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED.
5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE.
6)ALL CONDUCTORS WILL HAVE A 9G'C RATING TO ENSURE CODE COMPLIANCE.
SOLAR CONTRACTOR-
7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646, IEC61730.
8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS.
9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS.
10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM.
11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE
ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER.
12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122.
13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS.
14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT.
15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR.
SIGNAGE-
16)PV SYSTEMS SHALL BE CLEARLY MARKED 114 ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES.
17)ALL SAFETY MARKING I PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS.
18)MARKING I PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL HE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT J'.
19)ALL WIRINGIRACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE.-OR EQUIVALENT;WIRINGIRACEWAYS SHALL BE MARKED EVERY 10'.
allILDER ELECTRICAL AND SOLAR CONTRACTORS-
20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER.
21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26.
CAMELLIA AT LENNAR: ORIGINAL BY, KIM ABC UWER I DATE-16.06.09
980 MONTECITO DRIVE, #302 REVIEWED BY: SHAUN MARUNA I DATE.16.06.10
THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION
Gia namasbd
�.L�.
DWG TITLE: PAGE#- SCALE: SITE LOCATION: 4571 Broadway Street
INDIVIDUAL 29741 ARGYLE CIRCLE Boulder.CO 80304
PLOT PLAN 3 NTS MENIFEE,CA 303.447.0300
NOTES _1
CAUTION:
POWER TO THIS BUILDING IS SUPPLIED BY THE IT
UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS
ARE LOCATED AS SHOWN.
)4q1i
DATE
ir,or an
or city
kept on the
PV AC DISCONNECT_____,.,
EXTERIOR -GARAGE
UTILITY METER a
MAIN SERVICE PANEL
(VERIFIED BY BUILDER)
S st
OLADECK WIRE
TRANSITION BOX
(UNDER ARRAY)
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
1-877-SLR-POWR
PV POWER SOURCE — AC SPECS
AC OPERATING VOLTAGE: 240 V
AC OPERATING CURRENT: 9.9 A
NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION
ORIGIN
CAMELLIA AT LENNAR:
980 MONTECITO DRIVE.#302 REVIEWED BY:SHAU14 MARUNA I DATE;16.06.10
THE LAKES CORONA,CA 92879 REV.# BY DATE I DESCRIPTION mastl§
DWG TITLE: PAGE#: I SCALE: SITE LOCATIOW I S. SOLAR
4571 Bmadway Street
INDIVIDUAL 29741 ARGYLE CIRCLE Boulder,CO 80304
PLOT PLAN NTS 303.447.0300
.1 MENIFEE,CA I —