PMT16-02971 City of Menifee Permit No.: PMT16-02971
29714 HAUN RD. Type: Residential Electrical
<A—CCEIl' MENIFEE, CA 92586
MENIFEE Date Issued: 0910912016
P E R M I T
Site Address: 29749 ARGYLE CIR, MENIFEE, CA 92584 Parcel Number: 364-370-028
Construction Cost: $8,331.60
Existing Use: Proposed Use:
Description of SOLAR TR 30422-3 CAMELLIA
Work: 12 MODULES,3.18KW
LOT 117
Owner Contractor
LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC
980 MONTECITO DR#302 25 ENTERPRISE
CORONA,CA 92879 ALISO VIEJO,CA 92656
Applicant Phone:9493498269
JEREMIAH ACAYTURRI License Number:728102
LENNAR HOMES OF CALIFORNIA INC
25 ENTERPRISE
ALISO VIEJO, CA 92656
Fee Description 9-ty. Amount($)
Solar, Residential or Small Commercial 1 252.00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 2.00
General Plan Maintenance Fee-Electrical 12.60
$294.60
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing builiding operations being carried an thereunder when in violation of the Building Code or.of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
Akl3ldg_Permit-Template.rpt Page 1 of 1
BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION
Menifee
DATE 08/31/2016 PERMIT/PLAN CHECK NUMBER 03-t9-71
TYPE: F1 COMMERCIAL F]RESIDENTIAL [—]MULTI-FAMILY E]MOBILEHOME E]POOL/SPA E]SIGN
SUBTYPE: DADDITION DALTERATION []DEMOLITION F]ELECTRICAL E]MECHANICAL
ENEW []PLUMBING [:]RE-ROOF-NUMBER OF SQUARES
DESCRIPTION OF WORK Solar Permit-Plan 2785-3.18KW/12 PCS
Ncks�er R'wmit
PROJECTADDRIESS 29749 Argyle Circle
ASSESSOR'S PARCEL NUMBER &SLj- 37()— LOT 117 TRACr 30422-3
PROPERTY OWNER'S NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr.Suite 302,Corona, CA 92879
PHONE (951)817-3680 EMAIL jeremiah.aGayturri@lennar.com
APPLICANTNAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr.,Suite 302,Corona, CA92879
PHONE (951)817-3680 EMAIL leremiah.acayturri@lennar.com
CONTRACTOR'S NAME Lermar Homes of California, Inc., OWNERBUILDER? R]YES[—]NO
BUSINESSNAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr., Suite 302, Corona.CA
PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com
CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B
VALUATION$ $8,331-60 SO FT L SOL FT
APPLICANT'S SIGNATURE DATE 08/31/2016
S; Y
DEPARTMENT DISTRIBUTION CITY 01 MENIFEE BUSINESS LICENSE NUMBER
�7G SMIP C��'
kv ov
BUILDING PLANNING ENGINEERING FIRE GREEN SMIP
INVOICE PAIDAMOUNT 0 CASH 0 CHECK# OCREDITCARD VISAIMC
AMOUNT I
PLAN CHECK FEES PAIDAMOUNT 0 CASH 0 CHECK# OCREDITCARD VISA/MC
OWNER BUILDER VERII ]ED OYES 0 NO DLNUMBER NOTARIZED LETTER 0 YES 0 NO
City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777
www.citvofmenifee.us Inspection Request Line 951-246-6213
SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED
ITEM OTY MFR. 1 MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE
MTEM SIZE 3.12 KW LOCATIONS INDICATED BY THE ILLUSTRATION.
MODULE 2 PCS. HYUNDAI I HiS-S265RG (265W) BUYER:
INVERTER 12 PCS.1 ENPHASE I M215-60-ZLL-S22-IG
ROOF TYPE TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: CITY Of MENE
SU13-ARRAY INFORMATION
ARR Y#1 1 AR�Ly#2 1 ARLAY#3 BUILDINGANI
L N-
MOD QTY 12 NA A BUYER:
TILT 1 23- 1 NAo I NA' DATE: PLAN APPROV
AZIMUTH 1 180- 1 NA' I NA' REVIEWED
City of Menifee
Building Dept *Approval of these plans:
approval of,any violation
SEP 0 7 NIF, regulations and ordin2ncc
jobsite until completion,
c i v e d
F- — —— J-————————— — — ———————-
23*-1'ARRAY
23'-Il*FLASHING—,
L
F
SOLADECK WIRE
TRANSITION BOX L
(UNDER ARRAY)
PV AC DISCONNECT
EXTERIOR-GARAGE
UTILITY METER a
MAIN SERVICE PANEL
(VERIFIED BY BUILDER)
IL————— ——— —— — —— ———
.9
doom
NOTE;DIMENSIONS ARE SHOWN IN PLANE OF ROOF IN
D AN 715 ELEVATION B
L IEN?---
OR TATION I LOT# 117
CAMELLIA AT LENNAR: ORIGINAL BY: KIM ABCOUWER DATE:16-06�09
980 MONTECITO DRIVE,#302 REVIEWED BY:SHAUN MARUNA I DATE:16.06.10
THE LAKES CORONA,CA 92879 REV.# BY DATE I DESCRIPTION mast;6
I S.i $GLAR
DWG TITLE: PAGE#- SCALE: SITE LOCATION: 4571 BroodWay Street
INDIVID 29749 ARGYLE CIRCLE Boulder,CO 80304
PLOT_P 1116'=1'-0' 1 303.447.0300
1 MENIFEE.CA
MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS
ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL
LOCATION MENIFEE,CA INV. MAKE INVERTER SPEC ENPHASE
TEMP.AMBIENT HIGH(THAX) ASHIRAE 2% 'C 37 INV. MODEL INVERTER SPEC M215-60-2LL-S2F—]G
TEMP,AMBIENT LOW(TMIN) ASHRAE EXTR.MIN -C -2 INV. MAX POWER,(WAC MAX) INVERTER SPEC WATTS(AC) 225
TEMP.MODULE TEST(TTEST) MODULE SPEC C 25 INV. INPUT V.(VDc MAX) INVERTER SPEC VOLTS(DO 48
TEMP.DELTA LOW(TOELTA) Tm[N-TTEsT C -27 INV. OUTPUT V,FVAC MOM) INVERTER SPEC VOLTS(Ac) 240 r
MOD. MANUFACTURER MODULE SPEC HYUNDAI INV. OUTPUT FREOUENCY INVERTER SPEC HERTZ 60
MOD. PART NUMBER_ MODULE SPEC HiS-S265RG INV. OUTPUT CURRENT,IAC INVERTER SPEC AMPS(AC) 0.9 IAI-1-
MOD. POWER STC(P) MODULE SPEC WATTS(oc) 265 INV. PHASE GUANTITY INVERTER SPEC PHASE I
MOD. POWER PTC MODULE SPEC WATTS(oc) 238 COMPLIANCE INVERTER SPEC UL1741/IEEEI$47
MOD. OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS ODC) 1 31.30 INV. GROUNDING INVERTER SPEC ISOLATED
MOD. OPEN CCT. VOLTAGE(Voc) MODULE SPEC VOLTS(DC) 38.10 INV. OTY,MAX I BRANCH CCT. INV.OTYac OTY 12
MOD. COEFF. VOLT/TEMP(COEF) MODULE SPEC VI-C -0.114 BRANCH CCT. OUTPUT, IMAXEC (IAC*INV.QTYBC) AMPS(AC) 10.80
MOE). MAX VOLTAGE(VMAXM00) (Voc+ (TD-COEF)) VOLTS(DC) 41.18 INV. QUANTITY,TOTAL INV.GTYT OTY 12
MOD. OPERATING CURRENT(IMP) MODULE SPEC AMPS(oc) 8.50 TOTAL SYSTEM OUTPUT, IMAXTS (IAC*INV.OTYTI I AMP�fAQ 10.80
MOD. SHORT CCT. CURRENT(Isc) MODULE SPEC AMPS(DC) 9.00
MOD. MAXIMUM CURRENT(IMAX) (ISC* 1.25) AMPS(DC) 11.25
MIN. AMPACITY REG'D,PER NEC (IMAX* 1.25) AMPS(DC) 14.06
SERIES FUSE RATING,MAX MODULE SPEC AMPS(N) 15 not be a
ELECTRICAL EQUIPMENT SCHEDULE
KEY OTY MANUFACTURER MODEL NOTES TRADE rovi m
1 12 HYUNDAI HjS-S265RG (265W) PV MODULE SOLAR 'his set f;
2 12 ENPHASE M215-60-2LL-S22-IG RVINVERTER SOLAR
3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX, NEMA 3R SOLAR
4 1 CUTLER-HAMMER DG221URS PV AC DISCONNECT.NEMA 3R,24OV,30A SOLAR
5 1 ENPHASE ENVOY PV DATA MONITOR. 120V SOLAR
6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR
7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR
a NOTE CUTLER-HAMMER TBID PV BRANCH CIRCUIT BREAKERS;I x 15A-IP(ENVOY) SOLAR 1
9 NOTE CUTLER-HAMMER TBD PV BRE� ER,,IX 20A-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR
I I TBD 1 TBD E VICE PA MIN. 125A BUS I BLDR.ELEC.
I I TBD I TBD UTILITY METER,IPH, 1201240V,200A I BLDR�EI-EC-
12 1 1 TS I TBD GROUNDING ELECTRODE UFER I BLDR.ELEC. I
CONDUCTOR SIZING CALCULATIONS INTERCONNEC ION
1)CONDITION OF USE(COM I (AMPACITY- TEMP. DERATE* FILL DERATE)Is_REO'D(]MAX) ITEM UNIT PANEL
2)TERMINALS(TERM I AMPACITY AT TERMINALS. m REDO,(IMAX- 1,25) PANEL MFR. CUTLER-HAMMER
KEY SIZE CU/A1 INSULATION CALC. AMPACITY W/O TEMP. FILL I RESULT REO'D OCD BUS RATING AMPS 200
TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS Z2.00
A #12 CLI THWN-2 Cou 30 0.76 =1-022.80 10.80 — ALLOWED PV PER NEC AMPS 0
TERM 25 25 13.50 20 PV OCPD DEVICE USED AMPS
B #10 CU NM-B Cou 40 0.91 1.0 36.40 10.00
TERM 3.5 35 13.50 20
C #10 CU NM-B Cou 40 0.91 1.0 36-40 10�80
35 20
TERM 35 35 13.50
CONDUCTOR SCHEDULE
KEY SONDUCTORS CUIAL TYPE LOCATION TRADE
1 LOC T
ENGAGE CABLE, 1-966,FREE AIR CLI TC-ER TJFRAY SOLAR
8 S�10, 1-#10 EGC CU NM-B(ROMEX) I INTERIOR SOLAR
C 3410. 1410 EGC CU NM-B(ROMEX) INTERIOR SOLAR
D CAT5E,ETHERNET CABLE CU CAT5E INTERIOR SOLAR
M
SEE NOTE 15
15WIP
20Al2P
G LjG
N
G +
6 — 6 14152
ROOF EXTERIOR-GARAGE I
ELECTRICAL DIAGRAM 3.18 KW
LOT# 117
ORIGINAL BY: KIM ARCO WER DATE:16.06.09
CAMELLIA AT LENNAR- REVIEWED BY:SHAUN MARUNA DATE:16.06.10
980 MONTECITO DRIVE.#302
THE LAKES CORONA.CA 92879 DATE DESCRIPTION MaSIA
7 S it %.L�k
DWG TITLE- PAGE SCALE: SITE LOCATION: 4571 Broadway Street
INDIVIDUAL 29749 ARGYLE CIRCLE Boulder,CO 80304
PLOT PLAN 2 NTS MENIFEE,CA 303.447.0300
ELECTRICAL I
STRUCTURAL NOTES:
SOLAR CONTRACTOR
1)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'D.C.
2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE.
3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT.
4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED.
5)PV ARRAY WILL BE A MINIMUM OF 3"ABOVE THE COMPOSITE SHINGLE ROOF SURFACE.
6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION
MANUAL,VERSION 227.3.PUB 140113-ICC.JANUARY 2014. )EPA R1
7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH 01 SPACE BETWEEN PV MODULES. SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND THE EDGE
OF THE PV ARRAY I SUB-ARRAY.
8)UNURAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'.
ROOFING CONTRACTOR-
1)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING (COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'.
2)26 GAUGE INTERLOCKING FLASHING 'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE
APROVED PRIOR TO PV SYSTEM INSTALLATION.
3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT 0-)OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE. PEEL-N-STICK BASE TO
BE INSTALLED PER MANUFACTURERS SPECIFICATIONS.
4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE.
5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS.
6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO V,e a
INSTALLATION. vp fe fora
ns r
ELECTRICAL NOTES:
GENERAI_-
1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL).
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SMALL COMPLY WITH THE APPLICABLE VERSION OF THE NECICEC.
3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC
WELD.
4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE
MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINTIFINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED.
5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE.
6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE.
SOLAR CONTRACTOR-
7)MODULE CERTIFICATIONS WILL INCLUDE ULI703,IEC61646.IEC61730-
B)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS-
9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS.
10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVIERTER SYSTEM.
11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE
ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER.
12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122.
13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS.
14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT.
15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR.
SIGNAGE-
16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES.
17)ALL SAFETY MARKING I PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS.
18)MARKING /PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT t.
19)ALL WIRINGIRACIEWAYS/JUNCTION BOXES WILL HE MARKED'PHOTOVOLTAIC POWER SOURCE.-OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'.
BUILDER ELECTRICAL AND SOLAR CONTRACTORS-
20) INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER.
21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26.
LENNAR: ORIGINAL BY. KIM ABCOUWER I DATE:16.06.09
CAMELLIA AT 980 MONTECITO DRIVE.#302 REVIEWED BY: SHAUN MARUNA I DATE.16.06.10
THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION namast;6
t.2 ..Ll�
OWG TITLE PAGE#: SCALE SITE LOCATION: 4571 Bmad�ay Slureet
INDIVIDUAL 29749 ARGYLE CIRCLE Boulder,CO 80304
PLOT PLAN NTS MENIFEE,CA 303.447.0300
NOTES
CAUTION:
POWER TO THIS BUILDING IS SUPPLIED BY THE
UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ENT
ARE LOCATED AS SHOWN.
DATE
all the
SOLADECK WIRE
TRANSITION BOX—�
(UNDER ARRAY)
PV AC DISCONNECT
EXTERIOR-GARAGE
UTILITY METER 8
MA�N,SERVICE PANEL
(VER F ED BY BUILDER)
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
1-877-SLR-POWR
PV POWER SOURCE - AC SPECS
AC OPERATING VOLTAGE: 240 V
AC OPERATING CURRENT: 10.8 A
NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION
ORIGINAL BY: KIM ARCOUWER I DATE-16.06.09
CAMELLIA AT LENNAR:
980 MONTECITO DRIVE,#302 REVIEW D BY:SHAUN MARUNA I DATE 16.06.10
THE LAKES CORONA.CA 92879 REV.# BY DATE DESCRIPTION mcisrd
Sm SOLAI
DWG TITLE: PAGE SCALE: Boulder,CO 80304
SITE LOCATION: 4571 Broadway Street
INDIVIDUAL 29749 ARGYLE CIRCLE
PLAN 4 NTS 303.447.0300
MENIFEE,CA