PMT16-02969 City of Menifee Permit No.: PMT1 6-02969 29714 HAUN RD. Type: Residential Electrical <A-CCIEU� MENIFEE,CA 92586 MENIFEE Date Issued: 09/09/2016 P E R M I T Site Address: 29738 ARGYLE CIR, MENIFEE, CA 92584 Parcel Number: 364-370-026 Construction Cost: $7,650.40 Existing Use: Proposed Use: Description of SOLAR TR 30422-3 CAMELLIA Work: 11 MODULES,2.92KW LOT 115 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA, CA 92879 ALISO VIEJO, CA 92656 Applicant Phone:9493498269 JEREMIAH ACAYTURRI License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ALISO VIEJO, CA 92656 Fee Description Qtv Amount Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Electrical 1 12.60 $293.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced Within six months after issuance.or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA.BidgPerailt-Template.rpt Page 1 of 1 BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION 'I"'Menifee DATE 08/31/2016 PERMIT/PLAN CHECK NUMBER C011-a TYPE: []COMMERCIAL F]RESIDENTIAL F]MULTI-FAMILY [JMOBILEHOME F]POOL/SPA [—]SIGN SUBTYPE: [—]ADDITION F]ALTERATION F]DEMOLITION [— —]MECHANICAL ]ELECTRICAL F R]NEWE]PLUMBING []RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit-Plan 2399-2.92KW I 11 PCS McL<-+oe)r Permi4 14 RMT1 4-0Z6 50 PROJEcTADDRFSS 29738 Argyle Circle '? 0 —02G LOT 115 ASSESSOR'S PARCEL NUMBER 6C/- 37 TRACT 30422-3 PROPERTY OWNER'S NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.Suite 302, Corona, CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturd@lennar.com APPLICANT NAME Lermar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturd@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc., OWNERBUILDER? RIYESONO BUSINESSNAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302, Corona. CA PHONE (951)817-3680 EMAIL jeremiah.acayturd@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ $7,650.40 SQ FT L SQ FT APPLICANrS SIGNATURE DATE 08/31/2016 CITY STAFF USE ONLY DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN SMIP INVOICE I PAIDAMOUNT AN40UNT I � -- CASH 0 CHECK# OCREDITCARD VISA/MC PLAN CHECK FEES PAID AMOUNT I 1 0 CASH 0 CHECK# OCREDITCARD VISA/MC OWNER BUILDER VERIFIED OYES 0 No DL NUMBER NOTARIZED LETTER 0 YES 0 No City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777 www.citVcfmenifee.us Inspection Request Line 951-246-5213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 22L9y2�W LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 11 PCs HYUNDAI HIS-S265RG (265W) BUYER: INVERTER 1 11 PCS.1 ENPHASE I M215-60-2LL-S22-IG ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: SUB-ARRAY INFORMATION ARRAY#1 ARRAY#2 ARRAY#3 �21)QTY 3 NA BUYER: TILT 23. 23o NAc DATE: 11 OF MEN11 AZIMUTH 108- 1 MIBY#2 NA' BUILDING AN[ PLAN APPROV PEVIEWED City of Menifee Building Dept 'Approval of these plans s approval of,any violation I SEP 0 7 2015 re.plations and ordinance 131-21 ARRAY ,3L 14-FLASHING 5--5- Y-8. jobsite until completion. Received F- ——— — — ——— — — - ———— — — — -j I L —7 PV AC DISCONNECT I L _---�EXTERIOR-GARAGE UTILITY METER& MAIN SERVICE PANEL — — ————— (VERIFIED BY BUILDER) SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN 2399 ELEVATION 8-REVERSE ORIENTATION I L014 llb ORIGINAL BY: KIM ABCOUINER DATE:16.06.09 CAMELLIA AT LENNAR: REVIEWED BY,SHAUN MARUNA I DATE;16.06A0 980 MONTECITO DRIVE,#302 THE LAKES CORONA,CA 92879 REV.*_L BY I DATE I DESCRIPTION I I I Sm SOLAR DWG TITLE: PAGE#- SCALE: SITE LOCATION: 4571 Broad�y Street INDIV 29738 ARGYLE CIRCLE Boulder,CO 80304 PLOT 1/16'= 1'-0' MENIFEE.CA 303.447.0300 MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE /CALC UNIT DETAIL LOCATION MENIFEE.CA INV. MAKE INVERTER SPEC ENPHASE TEMP.AMBIENT HIGH (TMAX) ASHRAE 2% 'C 37 INV. MODEL INVERTER SPEC M215-60-2LL-S22-IG TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.M114 'C -2 INV. MAX POWER,(WAC MAX) INVERTER SPEC WATTS(AC) 225 TEMP. MODULE TEST(TTEST) MODULE SPEC C 25 INV. INPUT V,(VOC MAX) INVERTER SPEC VOLTS(cc) 48 TEMP, DELTA LOW(TOELTA) TruN-TTEST 'C -27 INV. OUTPUT V,(VAc NOM) INVERTER SPEC VOLTS(AQ 24,0 MOD.MANUFACTURER MODULE SPEC__ HYUNDAI INV. OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD. PART NUMBER MODULE SPEC HiS-S265RG INV. OUTPUT CURRENT. IAC INVERTER SPEC AMPS(AC) 0.9 MOD. POWER STC(P) MODULE SPEC WATTS(110 265 INV. PHASE QUANTITY INVERTER SPEC PHASE I MOD.POWER PTC MODULE SPEC WATTS(cc) 238 COMPLIANCE INVERTER SPEC UL174111EEM547 MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(DC) 31.30 INV. GROUNDING 1�N ED ,YERTYE,R SPEC OTY ISOLAT MOD.OPEN CCT. VOLTAGE(Voc) MODULE SPEC VOLTS(DC) 38.10 INV. OTY.MAX/BRANCH CCT. V.QT c 11 -A rr!� MOD.COEFF.VOLT/TEMP(CaEF) MODULE SPEC V/-C -0.114 BRANCH CCT. OUTPUT. MAXHC (IAC-INV.OTYac) I AMPS(AC) 1 9 90 1�1 L.I I MOD. MAX VOLTAGE(VMAXMOD) (Voc+(TD-COEF)) VOLTS(cc) 41.18 INV. QUANTITY,TOTAL INV.QTYT QTY 11 MOD. OPERATING CURRENT(Imp) MODULE SPEC AMPS(cc) 8.50 TOTAL SYSTEM OUTPUT. IMAXTS (IAC-INV.OTYT) AMPS(Ac) 9-90 MOD.SHORT CCT. CURRENT 0sc) MODULE SPEC AMPS(00 9.00 MOD.MAXIMUM CURRENT(IMAX) (Isc- 1.25) AMPS(cc) 11.25 MIN. AMPACITY REO'D, PER NEC (IMAX- 1.25) AMPS(cc) 14-06 1 SERIES FUSE RATING.MAX MODULE SPEC AMPS(cc) 15 ELECTRICAL EQUIPMENT SCHEDULE KEY OTY MANUFACTURER MODEL NOTES TRADE 00 1 11 HYUNDAI HvS-S265RG (265W) PV MODULE SOLAR 2 11 ENPHASE M215-60-2LL-SZ2-IG PVINVERTER SOLAR 3 2 RSTC ISOLADECK 0786-3RS PV ROOF JUNCTION BOX, NEMA 3R SOLAR 0'be cordIr 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT.NEMA 3R,240V.30A SOLAR IV pruvisjol s I 5 1 ENPHASE ENVOY PV DATA MONITOR. 120V SOLAR 6 1 TBD TED 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR his set of a;pr 7 1 TBD TED CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR 8 NOTE CUTLER-HAMMER T13D PV BRANCH CIRCUIT BREAKERS; I x i5A-1P(ENVOY) SOLAR 1 9 NOTE CUTLER-HAMMER T13D PV BREAKER,I x 2OA-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 1 TOD TEID 1 SE VICE PANEL, MIN. 125A BUS OTL IL17Y i�ETER,F 11 1 TBD TED PH, 120/240V. 200A .21�EELLIC 1 12 1 1 1 TBD TBD GROUNDING ELECTRODE UFER BLDR.ELEC. CONDUCTOR SIZING CALCULATlONS INTERCONNECTION CALCULATIONS 1)CONDITION OF USE(COU); (AMPACITY-TEMP. DERATE FILL DERATE) M_REQ'D(IMAX) ITEM UNIT PANEL 2)TERMINALS(TERM): AMPACITY AT TERMINALS. REQ'D. (Imx- 1.25) PANEL MFR. CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REG'D OCD BUS RATING AMPS 200 TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 A *12 CU THWN-2 COU 30 0.76 1-0 22.80 9.90 ALLOWED PV PER NEC AMPS 40 TERM 25 25 12.38 20 PV OCPD DEVICE USED AMPS 20 B #10 CU NM-B COU 40 0.91 1.0 36.40 9.90 TERM 35 35 12.38 20 C #10 CU NM-B COU 40 0.91 1.0 36.40 9.90 TERM 35 35 12.38 20 CONDUCTOR SCHEDULE P CONDUCTORS CU/AL 1 TYPE 1 LOCATION I TRADE A 1 #12 EENGAGE CABLE, 1-#6G,FREE AIR i i ICU I TC-ER IARRAY 1 SOLM B 1 3-#10, 1�10 EGC CU I NM-B(ROMEX) I INTERIOR SOLAR 10, 11to C t13-#10, 1-#tO EGC CU NM-B(ROMEX) I INTERIOR ISOLAR D I CATSE.ETHERNET CABLE I Cu I CAT5E I INTERIOR ISOLAR M SEE NOTE 15 \4j 5WIP G I ID A 2OAl2P I MG G G N 6C ROOF EXTE IOR-GAF ELECTRICAL DIAGRAM 2.92 KW LOT# 115 LENNAR: ORIGINAL BY: KIM ABCOUWER DATE:16.06.09 CAMELLIA AT 980 MONTECITO DRIVE.#302 REVIEWED B :SHAUN MARUNA DATE:16.06.10 THE LAKES CORONA.CA 92879 -§EV.# I BY DATE I DESCRIPTION namast;6 DING TITLE. PAGE Ar: SCALE: SITE LOCATION: SOLAR INDIVIDUA 4571 Broadway Street 2973B ARGYLE CIRCLE Boulder,CO 80304 P 2 NTS 3G3-447.03GO F I MENIFEE,CA I I I STRUCTURAL NOTES: SOLAR CONTRACTOR- 1)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 4.8"O-C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS.TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3"ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UN)RAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL,VERSION 227.3.PUB 140113-ICC,JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH W)SPACE BETWEEN PV MODULES. SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. PARTME ROOFING CONTRACTOR- 1)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. 2)26 GAUGE INTERLOCKING FLASHING 'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT 00 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE.DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS- 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE- COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. ie a pi rmi federal,stai I plans m -st I ELECTRICAL NOTES: GENERAL- 1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC- 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURES FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINTIFINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90*C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646.IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS- 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING.OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT- 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING /PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING /PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE.'OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26, LENNAR: ORIGINAL BY: KIM ABCO "N' REVIEWED BY: SHAU N 980 MONTECITO DRIVE,#302 UW 19 CAMELLIA AT N 11TRUMA 12.1TE Elo THE LAKES CORONA.CA 92879 REV.# BY DATE I DESCRIPTION narnasti§ t. SOLAR OWG TITLE. PAGE*: SCALE: SITE LOCATION: 4571 BroadwaySbeet INDIVIDUAL 29738 ARGYLE CIRCLE Boulder,CO 80304 PLOT PLAN 3 NTS MENIFEE, CA 303.447.03M NOTES I CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. 7 DIATE )r an j-'y on the PV AC DISCONNECT -�EXTERIOR-GARAGE UTILITY METER& ]-�MAIN SERVICE PANEL (VERIFIED BY BUILDER) SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: 9.9 A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION CAMELLIA AT LENNAR: ORIGINAL BY-- KIM ABCOUWER DATE:16.06.09 980 MONTECITO DRIVE,*302 REVIEWED BY:SHAUN MARUNA DATE:16.06.10 THE LAKES CORONA.CA 92879 REV.# BY DATE DESCRIPTION Cn.2namast;d G SOLAR DING TITLE PAGE SCALE: SITE LOCATION: 4571 Broadway Street INDIVIDUAL 29738 ARGYLE CIRCLE Boulder,CO 80304 PLOT PLAN NTS MENIFEE.CA 303."7.0300