PMT16-02967 City of Menifee Permit No.: PMT16-02967
29714 HAUN RD. Type: Residential Electrical
't�-VCClE1:A—> MENIFEE, CA 92586
G�""A W.— MENIFEE Date Issued: 0910912016
P E R M I T
SIte Address: 29718 ARGYLE CIR, MENIFEE, CA 92584 Parcel Number: 364-370-024
Construction Cost: $6,943.00
Existing Use: Proposed Use:
Description of SOLAR TR 30422-3 CAMELLIA
Work: 10 MODULES,2.65KW
LOT 113
Owner Contractor
LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC
980 MONTECITC,DR#302 25 ENTERPRISE
CORONA,CA 92879 ALISO VIEJO, CA 92656
Applicant Phone:9493498269
JEREMIAH ACAYTURRI License Number:728102
LENNAR HOMES OF CALIFORNIA INC
25 ENTERPRISE
ALISO VIEJO, CA 92656
Fee Description 9tt Amount
Solar, Residential or Small Commercial 1 252.00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 1.00
General Plan Maintenance Fee-Electrical 1 12.60
$293.60
The issuance of this permit shall not prevent the building official from thereafter requiring the correclion of errors in the plans and
specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bldg_Pemit Template.rpt Page I of 1
BUILDING & SAFETY PERMIT/PLAN CHECK APPLICATION
"11- Menifee
DATE 08/3112016 PERMIT/PLAN CHECK NUMBER
TYPE: FICOMMERCIAL E]RESIDENTIAL [-]MULTI-FAMILY [-]MOBILEHOME [:]POOL/SPA F]SIGN
SUBTYPE: []ADDITION [-]ALTERATION [-]DEMOLITION FIELECTRICAL [-]MECHANICAL
Z NEW D PLUMBING El RE-ROOF-NUMBER OF SQUARES
DESCRIPTION OF WORK Solar Permit-Plan 2077-2.65KW/10 PCS
Mcksler Pf2xmA -# PMTH -0-2-63r)
PROJECTADDRESS 29718 Argyle Circle
ASSESSOR'S PARCEL NUMBER 904 - -oZq LOT 113 TRACT 30422-3
PROPERTY OWNER'S NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr.Suite 302, Corona, CA 92879
PHONE (951)817-3680 EMAIL jeremiah.acayturr'i@lennar.com
APPLICANTINIAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879
PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com
CONTRACTOR'S NAME Lermar Homes of California, Inc., OWNERBUILDER? ZYESONO
BUSINESSNAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr., Suite 302,Corona.CA
PHONE (951)817-3680 EMAIL jeremiah.acayturrl@lennar.com
CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B
VALLIATION$ $6,943.00 SQ FT LSQFT
APPLICANT'S SIGNATURE
CITY STAFF USE ONLY
DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER
BUILDING PLANNING ENGIIVEERIAIG FIRE GREEN SMIP lit,
INVOICE 1 PAID AMOUNT CASH 0 CHECK# 0 CREDIT CARD VISA/MC
AMOUNT
PLAN CHECK FEES PAID AMOUNT 0 CASH 0 CHECK# 0 CREDIT CARD VISA/MC
OWNER BUILDER VERIFIED 0 YES 0 No DLNUMBER NOTARIZED LETTER 0 YES 0 NO
City of Menifee Building&Safety Department 29714 Houn Rd. Menifee, CA 92586 951-672-6777
www.cityofirrenifee.us inspection Request Line 951-246-6213
SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED
ITEM I CITY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE
LYSTEM SIZE 1 2.�EK LOCATIONS INDICATED BY THE ILLUSTRATION.
MODULE 10 PCS.1 HYUNDAI I HIS-S265RG (265W) BUYER:
INVERTER 1 10 PCS.1 ENPHASE I M215-60- LL-S22-IG
ROOF TYPE I TILE W1 COMPOSITE SHINGLE UNDER ARRAY I DATE:
SUB-ARRAY INFORMATION
ARR #1 1 AR AY#2 1 ARRLY#3 FY OF MEN11
MOD QTY LY LN—A I NA BUYER:
TILT 23- NA- NA- I DATE: 13UILDING ANI
AZIMU1rH IBO' NA- NA- City of Men,i:�E. PLAN APPRM
Building Dept
SEP 0 72TiS REVIEWE61
ReceiVpri.
'Approval of these plans
TO,-I01 III-I, approval of,any violatiot
regulations and ordinanc
-- - - - - - - - -- -- --- -- - - - - -- jobsite until completion.
SOLADECK WIRE
_�TRANSITION BOX
(UNDER ARRAY)
120
PV AC DISCONNECT
,.�EXTERIOR-GARAGE
UTILITY METER&
J--1,MAIN SERVICE PANEL
(VERIFIED BY BUILDER)
--N
NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF
z
PLAN 2077 ELEVATION A-REVERSE
ORIENTATION 4 LU19 113
ORIGINAL BY: KIM ABCOUWER DATE:16.06.05
CAMELLIA AT LENNAR:
980 MONTECITO DRIVE,#302 REVIEWED BY,SHAUN MARUMA DATE:16.06.09
THE LAKES CORONA,CA 92879 RrV.#f BY DATE DESCRIPTION masrd
t SOLAR
DWG TITLE- PAGE SCALE: SITE LOCATION: 4571 Broad�y Sureet
INDIV 29718 ARGYLE CIRCLE Boulder,CO 80304
PLOT 1 1116'=l'-0' MENIFEE.CA 303.447.0300
MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS
ITEM NOTE /CALC UNIT DETAIL ITEM NOTE ICALC UNIT DETAIL
LOCATION MENIFEE,CA INV. MAKE INVERTER SPEC ENPHASE
TEMP.AMBIENT HIGH CTMAX) ASHRAE 2% C 37 INV- MODEL INVERTER SPEC M215-60-2LL-S22-IG
TEMP.AMBIENT LOW(TMIN) ASHRAE EXTR.MIN 'C -2 INV. MAX POWER.(WAC MAX) INVERTER SPEC WATTS(Ac) 225
TEMP.MODULE TEST(TTEST) MODULE SPEC C 25 INV. INPUT V, (VDC MAX) INVERTER SPEC VOLTS 00 48
TEMP.DELTA LOW(TDELTA) TmlN�TTEST C -27 INV- OUTPUT V,(VAC NOMI 114VERTER SPEC VOLTS(AC) 240
MOD. MANUFACTURER MODULE SPEC HYUNDAI INV. OUTPUT FREQUENCY INVERTER SPEC HERTZ 60
MOD. PART NUMBER MODULE SPEC HiS-S265RG INV. OUTPUT CURRENT,IAC INVERTER SPEC AMPS(AC) 0.9
MOD. POWER STC(P) MODULE SPEC WATTS(cc) 265 INV. PHASE QUANTITY INVERTER SPEC PHASE P_ E
MOD. POWER PTC MODULE SPEC WATTS(DC) . 238 COMPLIANCE INVERTER SPEC UL1741/lEEEISgA
MOD. OPERATING VOLTAGE (VMP) MODULE SPEC VOLTS(cc) 31.30 INV. GROUNDING INVERTER SPEC ISOLATED 3 F
MOD. OPEN CCT. VOLTAGE(Voc) MODULE SPEC VOLTS W 38.10 INV. OTY, MAX/BRANCH CCT. INV_QTYBc OTY 10
MOD. COEFF. VOLTITEMP(COEF) MODULE SPEC vioc -0.114 BRANCH CCT. OUTPUT, IMAXBC (IAC'INV.QTYRC) AMPS(AC) 9.00
MOD.MAX VOLTAGE(VMAXMOD) (Voc+(To-CoEF)) VOLTS(DO 41.IB INV. QUANTITY.TOTAL INV.QTYT CITY 10
MOD. OPERATING CURRENT(imp) MODULE SPEC AMPS(cc) 8.50 TOTAL SYSTEM OUTPUT, IMAXTS (IAC-INV.QTYT) AMPS(AC) 9.00
MOD, SHORT CCT. CURRENT 0sc) MODULE SPEC AMPS(00 9-00
MOD. MAXI�UM CURRENT(]MAX) (Isc- 1.25) AMPS(cc) 11.25
N. -D,PER NEC - L25) AMPS(cc) 14.06
MPACITY REG (IMAX
SERIES FUSE RATING,MAX MODULE SPEC AMPS(cc) 15
ELECTRICAL EQUIPMENT SCHEDULE
KEY OTY I MANUFACTURER MODEL NOTES TRADE 1;not e
1 10 HYUNDAI HiS-S265RG (265W) PV MODULE SOLAR
2 10 ENPHASE M2l5-60-2LL-S22-IG PVINVERTER SOLAR any PI wi
3 1 RSTC/SOLADECK 07B6-3R5 PV ROOF JUNCTION BOX.NEMA 3R SOLAR
4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT.NEMA 3R,240%30A SOLAR Thiss I(
5 1 ENPHASE ENVOY PV DATA MONITOR, SOLAR
6 1 TBD TOD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR
7 1 TBD TSD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR
a NOTE CUTLER-HAMMER TBO PV BRANCH CIRCUIT BREAKERS:I x 15A-IP(ENVOY) SOLAR
9 NOTE CUTLER-HAMMER PV BREAKER, I x 2GA-2P.LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR
10 1 TSD TiS2D I SERVICE PANEL.MIN- 125A BUS E�ES
1 2L22 ELEC�
iI TBR I TBD I UTILITY METER, PH, 120/24OV.200A BLDR�
i T5D I TBID I GROUNDING ELECTRODE UFER BLDR_ELEC.
CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS
1)CONDITION OF USE(COLD: I (AMPACITY- TEMP. DERATE - FILL DERATE) vs. REO'D(IMAX) ITEM UNIT PANEL
2)TERMINALS(TERM): I AMPACITY AT T RMINALS. Y�_REG-D. MAX- 1.25) PANEL MFR. CUTLER-HAMMER
CALC. I AMPACITY W/O TEMP. FILL RESULT REO'D OCO BUS RATING AMPS 200
KEY SIZE CU/AL I INSULATION TYPE DERAJES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200
A #12 CU THWN-2 COU 30 0-76 1.0 22.80 9.00 - ALLOWED PV PER NEC AMPS 40
TERM 25 25 11.25 20 PV OCPD DEVICE USED AMPS 1 20
B #10 CU NM-B COU 40 0.91 1.0 36.40 9.00
TERM 35 35 11.25 20
C #10 CU NM-8 COU 40 0.91 1.0 36.40 9.00 ____j
TERM 35 35 11.25 20
CONDUCTOR SCHEDULE
KEY CONDUCTORS 1 CU/AL TYPE LOCATION TRADE
A 1-#12 ENGAGE CABLE, 146G.FREE AIR CU TC-ER I ARRAY SOLAR
B 3-#10. 1-#10 EGC CU I NM-B(ROMEX) I INTERIOR SOLAR
C 3-#10. 1-#10 EGC CU I NM-B(ROMEX) I INTERIOR SOLAR C16) ID
D CAT5E.ETHERNET CA13LE CU I CAT5E I INTERIOR I SOLAR M
E_"i i
SEE NOTE 15
SAMP
D9
2OAnP
1 � 14R HI N
G
G G___ j
ROOF GARAGE
ELECTRICAL DIAGRAM- 2.65 KW
LOT# 113
ORIGINAL BY: KIM ABCOUWER I DATE:16A6.08
CAMELLIA AT LENNAR: REVIEWED BY:SHAUN MARUNA I DATE:16.06.09
980 MONTECITO DRIVE, #302
THE LAKES CORONA,CA 92879 REV.# BY DATE I DESCRIPTION
Z!2namasud
SOLAR
DWG TITLE- PAGE#: SCALE: SITE LOCATION: 4571 BmadvAay Street
INDIVIDUAL 29718 ARGYLE CIRCLE Boulder,CO 80304
PLOT PLAN 2 NTS 303.447.0300
�,P,,.,rA. I MENIFEE,CA
STRUCTURAL NOTES-
SOLAR CONTRACTOR-
1)ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'D.C.
2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXT.ENT POSSIBLE.
5)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT.
4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED.
5)PV ARRAY WILL BE A MINIMUM OF 3"ABOVE THE COMPOSITE SHINGLE ROOF SURFACE.
6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOL94T CODE-COMPLIANT INSTALLATION
MANUAL.VERS10N 227.3,PUB 140113-ICC,JANUARY 2014.
7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(I-)SPACE BETWEEN PV MODULES. SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND THE EGG
OF THE PV ARRAY/SUB-ARRAY. G5 E PA I
8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'.
ROOFING CONTRACTOR-
1)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3%
2)26 GAUGE INTERLOCKING FLASHING 'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE
APROVED PRIOR TO PV SYSTEM INSTALLATION.
3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(I-)OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE. PEEL-N-STICK BA
BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS.
4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EA
5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS.
6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIROSTOP TO BE SPECIFIED BY ROOFER PRIOR TO
INSTALLATION.
p
01flefed2mal
,wed pla is n
ELECTRICAL NOTES:
GENERAL-
1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL).
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC.
3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC
WELD.
4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE*S FINISHED SURFACE
MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINTIFINISH. PAINTIFINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED.
5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE.
6)ALL CONDUCTORS WILL HAVE A 90*C RATING TO ENSURE CODE COMPLIANCE.
SOLAR CONTRACTOR-
7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730.
8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS-
9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS.
10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM.
11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS. WIRING SHALL NOT MAKE CONTACT WITH THE
ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER.
12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122.
13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS.
14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT.
15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR.
SIGNAGE-
16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES.
17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS.
18)MARKING I PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT J'.
19)ALL WIRINGIRACEWAYS/JUNCTION BOXES WILL BE MARKED"PHOTOVOLTAIC POWER SOURCE,'OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'.
BUILDER ELECTRICAL AND SOLAR CONTRACTORS-
20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER.
21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26.
LENNAR: ORIGINAL BY- KIM ABCOUNER I DATE:16.06.08
CAMELLIA AT 980 MONTECITO DRIVE.#302 REVIEWED BY: SHAUN MARUNA ,DATE:16.0�7_
TF
THE LAKES CORONA,CA 92879 REV.* BY DATE DESCRIP ON -
namas�.6
..L�R
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 B�d"y S�l
INDIVIDUAL 29718 ARGYLE CIRCLE Bould.,.CO 80304
PLOT PLAN 3 NTS MENIFEE,CA 303.447.0300
NOTES I
CAUTION:
POWER TO THIS BUILDING IS SUPPLIED BY THE
UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS :NT
ARE LOCATED AS SHOWN.
01110
SOLADECK WIRE
—�TRANSITION BOX
(UNDER ARRAY)
PV AC DISCONNECT
,—�EXTERIOR-GARAGE
UTILITY METER&
]--�MAIN SERVICE PANEL
U (VERIFIED BY BUILDER)
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
1-877-SLR-POWR
PV POWER SOURCE - AC SPECS
AC OPERATING VOLTAGE: 240 V
AC OPERATING CURRENT: 9.0 A
NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION
CAMELLIA AT LENNAR: ORIGINAL BY: KIM ABCOUWER DATE:16.06.08
980 MONITECITO DRIVE,#302 REVIEWED BY:SHAUN MARUNIA DATE:16.06.09
THE LAKES CORONA,CA 92879 REVm# BY DATE DESCRIPTION 0 amasUd
DWG TITLE: PAGE 4P
SCALE: SITE LOCATION: 4571 Broadway Street
INDIVIDUAL Z9718 ARGYLE CIRCLE Boulder,GO 80304
PLOT PLAN 4 NTS
PLACARDS I I MENIFEE,CA 2103-447.0300