Loading...
PMT16-02373 City of Menifee Permit No.: PMT16-02373 29714 HAUN RD. <ACCEL/> MENIFEE,CA 92586 Type: Residential Electrical MENIFEE Date Issued: 08/26/2016 PERMIT Site Address: 27710 GOETZ RD, MENIFEE, CA 92587 Parcel Number: 335-040-019 Construction Cost: $18,000.00 Existing Use: Proposed Use: Description of INSTALL GROUND MOUNTED SOLAR SYSTEM, 18 AC PANELS,5.886 kW Work: Owner Contractor ALAN MEYERS I E S RESIDENTIAL INC 27710 GOETZ ROAD P 0 BOX 947 MENIFEE,CA 92587 STAFFORD,TX 77497 Applicant Phone:2814982212 ALBERT GORRIN License Number:912189 1 E S RESIDENTIAL INC 1240 RAILROAD STREET CORONA, CA 92882 Phone: 9517378870 Fee Description Qtt t Amount 1E1 Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 Additional Plan Review Electrical 158 157.50 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 3.00 General Plan Maintenance Fee-Electrical 1 12.60 $453.10 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. CONDITIONS Condition Comment 1 MPU PERMIT AA_Bldg_Permit_Template.rpt Page 1 of 1 CITY OF MENIFEE LICENSED DECLARATION property who builds or improves thereon,and who contracts for the projects I hereby affirm under penalty of perjury that I am under provisions of with a licensed contractor(s)pursuant to the Contractors State License Law).. Chapter9(commencing with section 7000)of Division 3 of the Business and ❑I am exempt from licensure under the Contractors State License Law for Professions Code and my license is in full force and effect. the following reason: License Class dfIa License No. C/1 A-1 e el By my signature below I acknowledge that,except for my personal residence Expires 3/ A8 Signature � in which I must have resided for at least one year prior to completion of improvements covered by this permit.I cannot legally sell a structure that I WORKER'S COMPENSATION DECLARATION have built as an owner-builder if It has not been constructed in Its entirety by ❑I hereby affirm under penalty of perjury one of the following declarations:I licensed contractors.I understand that a copy of the applicable law,Section have and will maintain a certificate of consent of self-insure for workers 7044 of the Business and Professions Code,is available upon request when compensation,issued by the Director of Industrial Relations as provided for this application is submitted or at the fallowing website: by Section 3700 of the Labor Code,for the performance of work for which www.leginfo.ca.gov/calaw.htmi. this permit is issued. Policy If Date ❑I have and will maintain workers compensation insurance,as required by PROPERTY OWNER OR AUTHORIZED AGENT section 37UO of the Labor Code,for the performance of the work for which ❑By my signature below I certify to each of the fallowing:I am the property this permit is Issued.My workers compensation insurance carrier and policy owner or authorized to act on the property owners behalf.I have read this number are: application and the information I have provided is correct.I agree to comply Carrier OLD iZ FPUZSLr C ac0AFXAL with all applicable city and county ordinances and state laws relating to building construction.I authorize representatives of this city or county to Policy JfAll bWo B 61/50 S Expires 10 �l �/' enter the above identified property for inspection purposes. (This section need not to be completed is the permit is for one-hundred Date dollars($100)or less PROPERTY OWNER OR AUTHORIZED AGENT ci I certify that in the performance of the work for which this permit is issued, /may I shall not employ any persons in any manner so as to become subject to the CITY BUSINESS LICENSE n workers compensation laws of California,and agree that if I should become HAZARDOUS MATERIAL DECLARATION subject to the workers compensation provisions of Section 3700 of the Labor Code,I shall forthwith comply with those provisions. Will the applicant or future building occupant handle hazardous material or a Applicant Date Oil/n /�/G, mixture containing a hazardous material equal to or greater that the amounts specified on the Hazardous Materials Information Guide? WARNING:FAILURE TO SECURE WORKER'S COMPENSATION COVERAGE IS ❑Yes '#No UNLAWFUL,AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES Will the intended use of the building by the applicant or future building AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS($100,000),IN occupant require apermkfor the construction or modification from South ADDITION TO THE COST OF COMPENSATION,DAMAGES AS PROVIDED FOR Coast Air Quality Management District(SCAQMD)?See permitting checklist IN SECTION 3706 OF THE LABOR CODE,INTEREST,AND ATTORNEYS FEES for guidelines CONSTRUCTION LENDING AGENCY ❑Yes 'ONO 1 hereby affirm that under the penalty of perjury there is a construction Will the proposed building or modified facility be within 1000 feet of the lending agency for the performance of the work which this permit is issued outer boundary of a school? (Section 3097 Civil Code) ❑Yes WNo OWNER BUILDER DECLARATIONS I have read the Hazardous Material Information Guide and the SCAQMD I hereby affirm under penalty of perjury that I am exempt from the permitting checklist.I understand my requirements under the State of Contractors License Law for the reason(s)indicated below by the California Health&Safety Code,Section 25505 and 25534 concerning checkmark(s)I have placed nett to the applicable item hazardous material reporting.$)(Section 7031.5 oyes m No Business and Professions Code).Any city or county that requires a permit to Date construct,alter,improve,demolish or repair any structure,prior to its PROPERTY OWNER OR AUTHORIZED AGENT issuance,also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors State EPA RENOVATION,REPAIR AND PAINTING JRRPI License Law(Chapter 9(commencing with Section 7000)of Division 3 of the The EPA Renovation,Repair and Painting(RRP)Rule requires contractors Business and Professions Code)or that he or she is exempt from licensure receiving compensation for most work that disturbs paint in a pre-1978 and the basis for the alleged exemption.Any violation of Section 7031.5 by residence or childcare facility to be RRP-certified firms and comply with an Applicant for a permit subjects the applicant to a civil penalty of not more required practices.This includes rental property owners and property than($S00). managers who do the paint-disturbing work themselves or through their ❑I,as owner of the property,or my employee with wages as their sole employees.For more information about EPA's Renovation Program visit: compensation,will do( )all of or( )portion of the work,and the structure is www.eoa.zov/lead or contact the National Lead Information Center at not intended or offered for sale.(Section 7044,Business and Professions 1-800-424-LEAD(5323). Code;The Contractors State License Law does not apply to an owner of a o An EPA Lead-Safe Certified Renovator will be responsible forthis project property who,through employees'or personal effort,builds or improves the property provided that the improvements are not intended or offered for Certified Firm Name: sale.If,however,the building or improvement is sold within one year of Firm Certification No.: completion,the Owner-Builder will have the burden of proving that it was not built or improved for the purpose of sale. ❑No EPA Lead-Safe Certified Firm Is required forthis project because: ❑I,as owner of the property am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractors State License Law does not apply to an owner of a If your project does not comply with EPA RRP rule please fill outthe RAP Acknowledgement EsGil Corporation In Partnership with Government far Buifding Safety DATE: 08/23/2016 ❑ APPLICANT URIS. JURISDICTION: City of Menifee ❑ PLAN REVIEWER ❑ FILE PLAN CHECK NO.: PMT16-02372 & 02373 SET: II PROJECT ADDRESS: 27710 Goetz Rd. PROJECT NAME: ALAN MEYERS 18 @ 327 Watts Ground Mounted Micro-inverters Solar Photovoltaic System ® The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. ❑ The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. ❑ The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ❑ The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. ❑ The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ❑ The applicant's copy of the check list has been sent to: ® Esgil Corporation staff did not advise the applicant that the plan check has been completed. ❑ Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted:--Telephone #: Date contacted: -- (b�� ) Fax #: Mail Telephone Fax In Person E-mail: ® REMARKS: Main Panel will be upgraded. By: Sergio Azuela Enclosures: EsGil Corporation ❑ GA ❑ EJ ❑ PC 08/18/2016 9320 Chesapeake Drive, Suite 208 ♦ San Die,go,California 92123 ♦ (858)560-1468 ♦ Fax(858)560-1576 City of Menifee PMT16-02372 & 02373 I /1 08/01/16 T [DO NOT PAY— THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: City of Menifee PLAN CHECK NO.: PMT16-02372 & 02373 PREPARED BY: Sergio Azuela DATE: 08/01/16 BUILDING ADDRESS: 27710 Goetz Rd. BUILDING OCCUPANCY: TYPE OF CONSTRUCTION: BUILDING AREA Valuation Reg. VALUE ($) PORTION ( Sq. Ft.) Multiplier Mod. Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code mnf Manual Input Bldg. Permit Fee by Ordinance Pbn Check Fee by Ordinance Type of Review: ❑ Complete Review ❑ Structural Only ❑R n epetitive Fee Other Repeats � 1.5 Hrs. @ ' EsGil Fee $105.00 $157.50 Based on hourly rate Comments: 1 112 hours plan review. Sheet 1 of 1 macvalue.doc+ VINCI & ASSOCIATES c$iruc(ural Onyincers July 22, 2016 City of Menifee Building $ Safety Dept. IES Residential 1240 Railroad Street AUG 9 ) 2016 Corona, CA 92882 Subject: Review of minimum footing requirements Project: (18) Module Photovoltaic Groundmount Installation (1 Array) Meyers Residence 27710 Goetz Road, Menifee, CA 92587 V&A Project No. 12-3457 The purpose of this report is to provide a site specific analysis of the minimum footing requirements for the photovoltaic array groundtrac installation at 27710 Goetz Road in Menifee, CA 92587. Based upon our review of the 1 Photovoltaic Array, installed 2 modules high and 9 modules wide. The PV Array shall have a transverse spacing of approximately 6.92 feet on center and a longitudinal spacing of 7.00 feet maximum. Based upon a wind speed of 100 mph, Exposure C, it was determined that the minimum required footing depth is 30 inches minimum below grade for a 12 inch diameter pier footing. The footing sizes are based upon the worst case loading due to horizontal and vertical wind loading. Refer to attached calculations and details for additional information. `u Our professional services have been performed using the degree of care and skill ordinarily (� exercised under similar circum n s b eputable engineers practicing in this locality. No other warranty, expres ed o m ed made as to the professional options included in this report. We hope t s ro de rwith the Information you need at this time. Please call us if you have any sti s ing this report. Sincerely, C VINCI A TES No. 54411 Fxp. 12/31/17 n _ Ja nci, S.E. r�q sr�y'mug�� �* FOF CAU is se No. S-4411 175 E.WILBUR ROAD, STE 103 • THOUSAND OAKS, CA 91360 p 805.496-2100 . f 805.496.2442 . e vinci@vincise.com DATE 7/22/2016 VINCI & ASSOCIATES SHEET: Al PROJECT: Meyers Residence c5/ruchmtl(5ngineerr JOB NO.: 12-3457 27710 Goetz Road 175 E.WILBUR ROAD,STE 103 THOUSAND OAKS.CA 91360 ENGR. JRV Menifee, CA 92587 n805.496.2100 • r805496.2442 • e scAar@VInrJSE.mm CLIENT: IES Residential DESIGN DATA: WIND DESIGN CRITERIA: BASIC WIND SPEED = 100 mph (ASCE 7-10., Risk Category I per Table 1.5-1 &Figure 26.5-1C) WIND EXPOSURE = C GROUND SNOW LOAD = 0 psf SOLAR MODULE ARRAY DATA Sloped Dimension of Array = 124 in Angle of Array = 12 degrees Slope of Array: = 2.49 : 12 No. of Modules in Transverse Direction = 2 No. of Modules in Longitudinal Direction = 9 Total No.of Modules in Project = 18 Transverse Post Spacing = 6.92 ft Longitudinal Post Spacing = 7.00 ft Number of supports-Transverse Direction = 2 Diameter of Pier Footing = 12 in Number of Arrays = 1 Array Uniform Load = 2.8 psf SOIL DESIGN CRITERIA (Based upon Chapter 18 of CBC) Allowable Soil Bearing Pressure = 1500 psf Allowable Soil Lateral Bearing = 200 pcf (CBC 1806.3.4) Allowable Shaft Skin Friction/Cohesion = 130 pcf PROJECT: Marps a ReaWence _- PAGE: 1JU CLIENT: 27710Goete Road,MQdit-(id62'fi.B,,_ DESIGN BY: my JOBNO.: .153467 DATE: IW=16.. REVIEW BY: W d Analysis-forOpen Structure Solar Panels Based on ASCE 72010 - 1 2013CBC INPUT DATA Exposure category is,C ar D) = C _ Importance factor.1.0 only,(Table 1.5-2) I„ = 1.00 Bask wind speed tASCE 7.1026.5,1) V = 100 mph - Topographic factor(26A9 Table 26a-1) Ka = 1.54 1°p Height of mean roof h = 5 it '1-2 • Roof slope 2.49 : 12 t Roof length L = 1D 0 Roof horizontal projected width B = 11) it Effective area of component l cladding A = 1R 02 s.IN°i`c1Cd) DESIGN SUMMARY 1.Main Wind-Force Resisting System Max horimnlal force I base shear from roof = 0.67 kips + 0.07 kips(eave&columns Increasing) E 0.74 kips Max vertical download force = 3.24 kips Max vediwl uplift force = 3.16 kips Max moment at cemroid of base from roof = 7.42 0-kips + 0.74 fl-kips leave&columns increasing) E 8.17 fl•kips 2.Component and Cladding Elements Max Imvard pressure = 82 psi Max net outward pressure = 110 psi ANALYSIS Velocity pressure qh=0.00256 Kh Ka KeV' = 28A5 psi where: 4h=velocity pressure at mean mot heghL h.(Eel.28.3-1 page 298 8 Eq.30.3.1 page 316) KIN-velocity pressure exposure coefficient evaluated at height h,(Tab.29]-1,pg 299) = 0.85 Kd=wind directionality factor.(Tab.26.6-1,for building,page 250) = 0.85 h=height of mean roof = 5.00 it Main WInd.Fome Resisting Svatem(Sec.27A.3) p=ghGCH F=pAr where: G-gust effect factor.(Sea 26.9) = 0.85 0=roof angle = 11.75 degree c 45 deg. [Satisfactory] A,=roof aclml area. = 51.1 le-windward 51.1 h2.:eeward Cn=net force coef5ctenls.(Fig.27.4-4.page 267) Check Fig.27.4.4 limitation h/B= 0.50 within(0.25,1.01 (Satisfactory] WIND TO BOTTOM y-00 W IND TO TOP,7=180° CLEAR FLOWI OBSTRUCTED CLEAR FLOW OBSTRUCTED 0 CASEM.OD L Caw Cm Cm CeL Crux C. A 17 -1.05 -1.50 1.13 1.56 0 14 -1.14 P(P .28 -25.65 -36.28 27.24 37.65 3 38 -27.65 11.75 F(kips) 4 -1.31 -1.85 1.39 1.92 0.17 -1.41 B 0 -1.93 -0.69 1.71 0.47 1.03 -0.30 p(Psi) D .46.59 .16.61 41.43 11.36 24.82 -7.26 F k 0 .2.38 -0.&5 2.12 0.58 1.27 -0.37 DATE 7/22/2016 VINCI & ASSOCIATES SHEET: A2.1 PRaEcr Pro Solar Ground Mount K5/n1c/um/6ngli?wrr JOB NO- 09-3457 27710 Goetz Road 175 E-MLBUR ROAD.STE IM THOUSAIO OAKS.CA 91390 ENGR. JRV Menifee,CA 92587 n 905A95.2100- I695,19B2w2 • it vhic*VWSE.c CLIENT. IES Residential CHECK WIND INCLUDING WIND GUST FACTOR FOR TOPOGRAPHICAL FACTOR OF A 10 slope (Max) Type of Slope: Encarpment 17.36 ft =ft ' H 17.3648 Le 50 = 0.35 > 0.20 Therefore from ASCE 7.05,Figure 6-4:: KL = 0.3 x= 24 ft x 24 Lb 50 = OAS K7 = 0.89 z= 2 ft z 2 Ln 50 = 0.04 K3 = 0.9 Kn = (1+K1K2KY Kr, = (1 + (0.30) (0.89) (0.90) }3 Kn = 1.54 DATE 7/22/2016 VINCI & ASSOCIATES SHEET A3 PROJECT: Meyers Residence 61mr/rrral6nginwre JOB NO 09-3457 27710 Goetz Road 175 E WILBUR ROAD,STE 103 THOUSAND OAKS,CA 91360 ENGR JRV Menifee,CA 92587 r805 496 2100 - 1805.41)8 2442 • .vIrrQ1AndSE.C= CUENT. IES Residential FOOTING DESIGN - PV Sloped Dimension: 124 in TYPICAL ARRAY PV Array Angle: 12 degrees Post Spacing: 7.00 It No.of Supports: 2 Footing Diameter(d): 12 in MAXIMUM VERTICAL FORCE: 3.24 k /(10.0 x 10.0) = 32.44 psf x 0.6= 19.47 psf MAXIMUM UPLIFT FORCE: 3.16 k /(10.0 x 10.0) = 31.60 psf x 0.6= 18.96 psf ASD Factor GROUNDTRAC SYSTEM CAST INTO EARTH Maximum Vertical Load: (Worst Case: DL+Wind) P= 19.47 psf + 2.8 psf DL + 0 psf snow = 22.27 psf P= 22.27 psf x( 121" /12"/ft) x( 84.0" /12"/ft) = 1575 Ibs for 2 Supports P= 788 Ibs/footing Try 12"diameter footing Soil Bearing= 788 /(p x 0.50) = 1003.5 psf << 1995 psf 1500 psf x 1.33(CBC Table 1806.2) Maximum Uplift Load: Therefore O.K. P= 18.96 psf - 2.8 psf DL = 16.16 psf P= 16.16 psf x( 121" /12"/ft) x( 84.0" /12"/ft) = 1143 Ibs for 2 Supports P= 572 Ibs/footing Try 12"diameter x 34" footing Allowable Uplift= Concrete DL+Soil Cohesion(130 psf x 1.33) per CBC Table 1806.2 [ (n x(d/2)') x 150 pcf x 2.5 ft )+ [(n x d) x 2.47 ft x 172.9 psf)= 1632 Ibs Design Ratio= ( 1,632 ibs /572 Ibs ) = 2.9 Therefore O.K. DATE 7/22/2016 VINCI & ASSOCIATES SHEET: A4 PROJECT: Meyers Residence c$/raclam/ I;nyineerr Joe No.: 09-3457 27710 Goetz Road 175 E.W ILBUR ROAD,STE 103 THOUSAND OAKS,CA 91360 ENGR JRV Menifee, CA 92587 P 805.496 2100 • f 605A96.2442 • e Nnd&ImISEro CLIENT: IES Residential DESIGN OF PIER FOOTING 8: POST CHECK WIND Post Spacing: 7.00 ft Number of Columns: 2 Horizontal Load: 4.5 psf Exposed Wind surface 3 ft -DESIGN BASED UPON NON-CONSTRAINED CBC FORMULA: (CBC Section 1807.3.2.1) d=(A/2)(1 + ( 1 + (4.36h/A))11.5)) A = (2.34 P)/(S1 ' b) P P = 39 ibs =4.5 psf x 7.0 It x 3 It/2 columns h = 5 ft (Average Height) S1 = 266 psf/ft x (d/3) (includes 1.33 increase for wind) h b = 12 in (diameter or diagonal of square) 1 � ' 1 Try = S1@(10)d A Calc d I � ' 1 (@) (Psf) (ft) f � f � d 1 89 1.028 2.94 1 ' 1.25 111 0.822 2.57 L-- 1,5 133 0.685 2.31 14 1.75 155 0.587 2.11 GOVERNS >>> ! 2 177 M514 1.96 2.25 200 0.457 1.82 DESIGN COLUMN M0I = Ph = 195 ft-lbs S.1 = Mm /Fp = 0.10 in' Fp= 0.66 x 35,000 psi ASTM A53, Gr B »»> USE: 1-1/2" Schedule 40 Pipe S= 0.31 in3 with 12 inch diameter x 24 inch MIN. deep concrete footing. DATE 7/22/2016 VINCI & ASSOCIATES SHEET A5 PROJECT Meyers Residence 31nm/uml&q neer4 JOB NO. 09-3457 27710 Goetz Road 175 E WILBUR ROAD.STE 103 THOUSAND OAKS.CA 91360 ENGR JRV Menifee,CA 92587 p 805,496.2100 • 1805.496.2442 • v WndQWnrJSE cm CHECK DESIGN DEPTH REQUIRED H/3= 8'/3 = 2.666667 ft min �x TAN (10) = x 2.66667 x = (2.67) 0.17633 x = 0.47 ft 5.64 in Ignore tap 11"of soil 10% slope 3 ft min ./ (10) D to dayllte C s.64 in d•w= 24in (see next sht) TOTAL FOOTING DEPTH REQUIRED 24.0 in + 5.64 in 29.64 in 2.47 ft below adjacent grade