Loading...
PMT16-02126 U y of Menifee Permit No.: KATM-02126 29714 HAUN RD. �ACCEL/l� MENIFEE,CA 92586 Type: Residential Electrical MENIFEE Date Issued: 07N8/2016 P E R H � T Slte Address: 27958 BLACKHAWK RD, MENIFEE, CA Parcel Plumber: 336-480-018 92585 Construction Cost: $10,000.00 Existing Use: Proposed Use: Description of INSTALL ROOF MOUNTED SOLAR SYSTEM, 12 PANELS, 1 INVERTER, 3.30 kW Work: Owner Contractor RICK WRIGHT SUNRUN INSTALLATION SERVICES INC 27958 BLACKHAWK ROAD 775 FIERO LANE STE 200 MENIFEE, CA 92585 SAN LUIS OBISPO, CA 93401 Applicant Phone:8886576527 JORDAN AUDIFFEREN License Number:750184 SUNRUN INSTALLATION SERVICES INC 775 FIERO LANE STE 200 SAN LUIS OBISPO, CA 93401 Phone:7607986548 Fee Description Qtv Amount($I nall Commercial 1 252 00 Building Permit Issuance 1 27.00 Flan Review Electrical 153 157.50 GREEN FEE 1 1.00 SMIF 1 2.00 General Plan Maintenance Fee-Electrical 1 12.60 $452.10 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing building operations being carded on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Template.rpt Page 1 of 1 City Of Menifee LICENSED DECLARATION ❑ lam exempt from Iicensure under the Contractors'State License Law for the I hereby affirm under penalty or perjury that I am licensed under provisions of following reason: Chapter 9(commencing with section 7000)of Division 3 of the Business and By my signature below I acknowledge that,except for my personal residence in Professions Code and my license is in full force and effect 'L which I must have resided for at least one year prior to completion of License Class —10 .rense.t SO I T improvements covered by this permit,I cannot legally sell a structure that I have Expires(D'30-SIP Signatu built as an owner-building if it has not been constructed in its entirety by licensed contractors.I understand that a copy of the applicable law,Section 7044 of the WORKERS'COMPENSATION DECLARATION Business and Professions Code,is available upon request when this application is submitted or at the following Web site: [II hereby affirm under penalty is perjury one the following declarations: hftp.,//www.leginfo.m.govlmlaw.html. I have and will maintain a certificate of consentt of self-insure for workers' compensation,issued by the Director of Industrial Relations as provided for by Date Section 3700 of the Labor Code,for the performance of work for which this permit is issued. Property Owner crAulhorizedAgent Policy# ❑ By my Signature below, 1 certify to each of the following:I am the property ❑ 1 have and will maintain workers' compensation insurance, as required by owner or authorized to act on the property owner's behalf. I have read this section 370o of the Labor Code, for the performance of the work for which this application and the information I have provided Is correct. I agree to comply permit is issued.My workers'compensation insurance carder and policy number are: with all applicable city and county ordinances and slate laws relating to building construction.I authorize representatives of this city or county to enter the above- Carrier ay-f aml identified property for the inspection purposes. Policy#WCOI&APdQ1 Expires_ /0' 1'1(P Date Properly Owner orAutharizedAgent } (This section need not be completed if the permit is for City Business License# 0756110 one-hundred dollars($100)or less) [II certify that in the performance of the work for which this perm[is issued,I HAZARDOUS MATERIAL DECLARATION shall not employ any persons in any manner so as to become subject to the Will the applicant or future building occupant handle hazardous material or a workers'compensation laws of California,and agree that if I should become mixture containing a hazardous material equal to or greater that the subject to the workers'compensation provisions of Section 3700 of the Labor amounts specified on the Hazardous Materials Information Guide? Code,I shall forthwfth ith those provisions. ❑YESNO Apphca Date; • !S-9 Will the intended use of the building by the applicant or future building occupant require a permit for the construction or modification from South WARNING: FAILURE TO SECURE WORKERS' Coast Air Quality Management District(SCAQMD)?See permitting checklist COMPENSATION COVERAGE IS UNLAWFUL, AND SHALL for guide�lirie��s SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES AND DYES C./NVO CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS ($100,000), IN ADDITION TO THE COST OF COMPENSATION, Will the proposed building or modified facility be within 1000 feet of the outer DAMAGES AS PROVIDED FOR IN SECTION 3706 OF THE boundary; fa school? LABOR CODE, INTEREST,AND ATTORNEYS FEES ❑YESId0 CONSTRUCTION LENDING AGENCY I have read the Hazardous Material Information Guide and the SCAQMD I hereby affirm that under the penalty of perjury there is a construction lending permitting checklist.I understand my requirements under the State of agency for the performance of the work which this permit is issued(Section California Health&Safety Code,Section 25505 and 25534 conceming 3097 Civil Code) hazardous material reporting. OWNER BUILDER DECLARATIONS l ES ❑NO Date �'(S•�� I hereby affirm under penalty of perjury that I am exempt from the Contractors License Law for the reason(s)indicated below by the checkmark(s)I have placed P E TY OWN OR AU TH 0 R I Z E D AG E N T next to the applicable item(s)(Section 7031.5.Business and Professions Code: Any city or county that requires a permit to construct,alter,improve,demolish, EPA RENOVATION,REPAIR AND PAINTING(RRP1 or repair any structure, prior to its issuance, also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the The EPA Renovation,Repair and Painting(RRP)Rule requires contractors provisions of the Contractor's State License Law(Chapter 9(commencing with receiving compensation for most work that disturbs paint in a pre4978 Section 7000)of Division 3 of the Business and Professions Code)or that he or residence or childcare facility to be RRP-certfried firms and comply with she is exempt from licensure and the basis for the alleged exemption. Any required practices.This includes rental property owners and property violation of Section 7031.5 by any Applicant for a permit subjects the applicant to managers who do the paint-disturbing work themselves or through their a civil penalty of not more than($500).) employees.For more information about EPA's Renovation Program visit: roe www.epa.gov/lead or contact the National Lead Information Center at ❑ I, as owner of the p p rty, or my employees with wages as their sole 1-800424-LEAD(5323). compensation,will do( )all of or( )porting of the work,and the structure Is not intended or offered for sale.(Section 7044,Business and Professions Code; The Contractor's State License Law does not apply to an owner of a property ❑An EPA Lead-Safe Certified Renovator will be responsible for this project who, through employees'or personal effort, builds or improves the property, provided that the improvements are not intended or offered for sale.If,however, Certified Firm Name: the building or improvement is sold within one year of completion,the Owner- Builder will have the burden of proving that it was not built or improved for the Firm Certification No: purpose of sale). ❑ 1, as owner of the property an exclusively contracting with licensed No EPA Lead-Safe Certified Firm is required for this project because: contractors to construct the project(Section 7044,Business and Professions Code:The Contractor's License Law does not apply to an owner of a property who builds or improves thereon, and who contracts for the projects with a EsGil Corporation In Tartnersbip with Government for Buifding Safety DATE: 07/14/16 ❑ APPLICANT ❑ JURIS. JURISDICTION: City of Menifee ❑ PLAN REVIEWER ❑ FILE PLAN CHECK NO.: PMT16-02126 SET: I PROJECT ADDRESS: 27958 Blackhawk Rd. PROJECT NAME: RICK WRIGHT 3,000 Watts Solar Photovoltaic System ® The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. ❑ The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. ❑ The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ❑ The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. ❑ The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ❑ The applicant's copy of the check list has been sent to: ® Esgil Corporation staff did not advise the applicant that the plan check has been completed. ❑ Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person E-mail: ❑ REMARKS: By: Sergio Azuela Enclosures: EsGil Corporation ❑ GA ❑ EJ ❑ PC 07/08 9320 Chesapeake Drive, Suite 208 ♦ San Diego, California 92123 ♦ (858) 560-1468 ♦ Fax(858)560-1576 City of Menifee PMT16-02126 07/14/16 [DO NOT PAY— THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: City of Menifee PLAN CHECK NO.: PMT16-02126 PREPARED BY: Sergio Azuela DATE: 07/14/16 BUILDING ADDRESS: 27958 Blackhawk Rd. BUILDING OCCUPANCY: TYPE OF CONSTRUCTION: BUILDING AREA Valuation Reg. VALUE ($) PORTION ( Sq. Ft.) Multiplier Mod. Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code mnf ima.uai Input Bldg. Permit Fee by Ordinance Plan Check Fee by Ordinance Type of Review: ❑ Complete Review ❑ Structural Only ❑Repetitive Fee Other Repeats E--� 1.5 Hrs. @ EsGil Fee $105.00 $157.50 Based on hourly rate Comments: 1 1/2 hours plan review. Sheet 1 of 1 macvalue.doc+ City of Menifee Building & Safety Dept. Structural Calculations for the Rick Wright Residence PV Installation JUL 0 / 2016 Date: 6/29/2016 Received Job Address: 27958 Blackhawk Rd Menifee, CA 92585 Job Number: 124R-958WRIG Scope of Work These calculations are for the existing roof framing which supports the new PV modules as well as the attachment of the PV system to existing roof framing. All PV mounting equipment shall be designed and installed per manufacturer's approved installation specifications. Calculation Index Sheet Description 2 Structural Geometry,Live Load,Snow Load, Wind Load, Dead Load, & Roof(1) Framing (/ i Check \� 3 Roof(1) Framing Check Continued, Roof Attachment Check,Seismic Check,&Scope of Work a✓ Engineering Calculations Summary Code: 2013 California Building Code ASCE 7-10 Snow Load: S= 0 psf Live Load: LL= 20 psf Wind: Wind Speed Ult.(V) = 110 mph Exp.= C PV Dead Load: DPV= 3.0 psf Q�p SSlpp Sincerely, a t h P T co No70 s Sage Lopez, P.E. * E"P/ Civil Engineer Engineer cr.& Sunrun, lnc OF CAUL 133 Technology Dr.,Suite 100, Irvine,CA 92618 1 P 949.393.0993 Engineer:SVL Date:6/29/2016 Job: 124R-958WRIG Address: 27958 Blackhawk Rd Menjfee,CA 92585 2of3 Structrure Geometry: Mean Roof Height,hn = 22 ft Eave Height,h. = 18 ft Buiding Length,L = 45 ft Building Width,B = 40 ft Module Area = 20 ft' Roof Pitch,B = 22 degrees Live Load: Roof Live Load,Lr = 20.00 psf Equation 4.8-1 Snow Load: Ground Snow Load,pe = 0 psf Fig.7-1 Wind Load: Basic Wind Speed(3s-gust) = 110 mph Figure 26.5-1A Building Occupancy Category = 2 Table 1.5-1 Exposure Category = C Sec 26.7.3 Topographlc Factor,Kzr = 1.00 Equation 26.8-1 Adjustment Factor,T = 1.35 Figure 30.5-1 Edge Zone,a = 4.00 ft Figure 30.5-1 Uplift(0.6W) Zone 1(psf) Zone 2(pso Zone3(psf) Pn.e30 = -19.40 -31.90 47.90 Figure 30.5-1 Pn.f=0.6 x A x Kzr x Pn eo) = -15.71 -25.84 -38.80 Equation 30.5-1 Downward(0.6W) Zone 1(psf) Zone 2(psf) Zone 3(psf) Pn.uo = 11.40 11.40 11.40 Figure 30.5-1 Pn.e=0.6 x)x KZr x Pneso = 9.60 9.60 9.60 Equation 30.5-1 Dead Load: Roof 1 : Roof Walls-Exterior Flat rile 9.0 psf Stucco 10.0 psf 5/8 OSB Sheathing 2.0 2x4 Studs @ 16" 2.0 2x4 Truss @ 24"OC 1.0 Gypsum 3.0 ' Misc.(Ceiling,Insulation,etc) 1.0 Misc.(Insulation,etc.) 2.0 PV System,Pw 3.0 Total Roof DL= 16.0 psf Total Wall DL= 17.0 psf • Rooflll Framine Check: Roof Framing = 2x4 Truss @ 24"OC Timber Species = Doug Fir-Larch 82 Max Beam Span = 5.00 ft b = 1.50 in d = 3.50 in Moment of Inertia,I. = 5.36 in' Section Modulus,S. = 3.06 in' Bending Stress,Fb = 900 psi Elastic Modulus,E.M = 580000 psi CD(Wind) CD(Snow) Cu Cm Ce Wood Adjustment Factors: 1.60 1.15--T 1.00 1.00 1.00 CL CF cf. G Cr 1.00 1.5 1.00 1.00 1.15 133 Technology Dr.,Suite 100, Irvine,CA 92618 1 P 949.383.0993 „= .. Engineer:SVL rP Date:6/29/2016 Job:124R-958WRIG Address:27958 Blackhawk Rd Menifee,CA 92585 3of3 Roof(1)Framing Check Continued: PV Tributary Width,War = 2.75 ft PV Tributary Length,Lpr = 6.00ft PV Tributary Area,At = 16.50 fit PV Dead Point Load,Po=Parx At = 46 lb Roof Distributed Load,wDL = 24 plf Load Case: 0.6DL+0.6W (CD=1.6) Roof Zone = 1 Pup=P.txAt+0.6xPoxcos(8) = 2321b MbW-, upl = 216 lb-ft Fb'(mndl=Fb xCo XW xCM XG xQ xCFxCru xG xG = 2484 psi M.ii.bk=S.x W(MM) = 634 lb-ft > 216 OK Load Case: DL+0.6W (CD=1.61 Pdp =Pnetx At+Pox MS(e) = 2041h Mb(rd.d d.l = 305 lb-ft Fb'(MM)=Fb xCo xCts xCM xCt XOL xCFxCry xO xG = 2484 psi MaN.W.=S.x W(MM) = 634 lb-ft > 305 OK Rafter Attachments:0.6D+0.6W(Zone 21 Pupch=Atx Pnegz) = 426Ib 5116”Lag Screw Withdrdwl Value = 266 lb/in Table 11.2A-Nos Lag Screw Penetration = 2.50 in Allowable Capacity with Co = 1064 lb > 426 OK Seismic Check: Existing Dead Load: Solar Dead Load: A�ure.�eun¢ = 1800 ft2 Wwnei = 42 It, Wmore.istft = 23400 lb Numwnel = 12 Aw Fle.isnn¢ = 3060 ft2 Wpa" tat = 504 lb Wrnne.mms = 52020 lb Wbue = 118 lb - Wmnl = 754201b W.mr = 622 lb %increase=Lwmtai+wamv)/wto i = 76042 '100%-100% = 0.82% " 75420 "The increase in weight as a result of the solar system is less than 10%of the existing structure and therefore no further seismic analysis Is required. Limits of Scope of Work and Liability we have based our structural capacity determination on applicable building codes,professional engineering inspection and design experience,opinions and judgments.The calculations produced for this dwelling's assessment are only for the proposed solar panel installation referenced in the stamped plan set and were made according to generally recognized structural anlaysis standards and procedures. 133 Technology Dr.,Suite 100, Irvine,CA 92618 1 P 949.383.0993 \gym LL j � kam� ER (k! �z� �� ca•k §z() § & ¥�� � , , , , \/k[ ~ ` \ §§ \- �� k } §® ! w ;§¢ % » \22CL \ ) § § §§ )� )( 2 \ \ ze & I $ §- ' !` | G z Zb ,P � k.0 \ \ �k § < §k 222� ® § ce ce§ Ln j� z) w��� \ g (§ \/([ §� kk(B ( ` ` ]§ § § () �( ° \ ! £ ° 4 2 §P k k� � ( 0z )w § � • ! § § Enua K ! « M k§ § � ) / 2 b) �§ § §E zq q tn \ §, §\ zk §$ §( ) } E� z 12e EL g§ g§ ! | \ § /\§§§ r /U5 W /f 2~®�2@ eww «>wzz z f00! !emul§6 P \ �/\ 4 `1 fl' REC TWINPEAK BLK SERIES PREMIUM SOLAR PANELS WITH SUPERIOR PERFORMANCE REC TwinPeak BLK Series solar panels feature an innovative design with high panel efficiency and power output,enabling customers to get the most out of the space used for the installation Combined with industry-leading product P quality and the reliability of a strong and established European brand,REC TwinPeak BLK panels are ideal for residential and commercial rooftops worldwide PIG e i 1 r „y MORE POWER HIGHER 100% REDUCES BALANCE OF OUTPUT PER M ENERGY YIELD PID FREE SYSTENICOSTS MrMTESSIV'iL1$"?3rY4.AS� REC TWINPEAK BLK 5ERIEr- EPPCB\v 33 YEAR PRODUCT WARRANTY - YEAR LINEAR POWER OUTPUT WARRANTY m Mountingholes R �TYr L� US HPORT DUTY FREE 0A360% •^'• �� 47 Nominal Operating Cell Temperature(NOCT) 44.6'C(t2'C) r`766 Temperature Coefficientof P1. -0.39%/'C .;%,. ut Temperature Coefficient ofVc, -0.31%/'C Temperature Coefficient offlx 0.045%/'C All measurements in Inches REC27OTP REC27STP REC28OTP NominalPower-P.(Wp) 265 270 275 280 Cell type: 120 REC HCmulti-crystalline Watt Class Sorting-(W) 0/+5 0/+5 0/+5 0/+5 6 strings of20 cells Wx3') NomiozlPovwrVoltage-V.(V) 313 31.2 31A 31.9 Glass: 1/8'mmsolarglasswith NomioalPowerOurrent-I (A) 8.53 8.66 8.76 g.7g anti-reflective surface treatment Backsheeh Double layerhlghlymsistantpolyester(white) OpenClrcuitVoltage-V.(V) 383 3B.6 38.8 39.2 Frame: Anodized aluminum(black) ShortCircuitCurrent.l,(A) 921 9.29 9.40 9.44 Junctionbox: apart withbypass diodes Panel Efficiency(%) 16.1 16.4 16.7 17.0 IP67rated Analy4 mm-solar cable,35'.47' Valueseddatadrd tostratestions ST%efpaneAM1.5.cedheve arrant and nce1000W/ma.altageamp.ranceofs3%homnaminal values. Connectors: Multi-Ccmoact MC44mm' Values a[standard mstcondlHans 6Tt!dMUSSAM LS,irradiance 1000 W/m;[all temperature25'C). ( ) At low Irradlance of 200 W/m'(AM 15 and cell temperature 2M atleast 94%of the STC panel effideney will be achieved Origin: Made in Singapore :i NominalPower-P.(Wp) 195 198 202 205 Operational Temperature: -40...+85'C Numinall'owel-Voltage-V.(V) 28.75 28.85 29.03 29.49 Maximum System Voltage: 1000V Nominall'owerCurrent-1 (A) 6.77 6.87 5.95 6,97 Design Load*: 75.2ibs/ft'(360OPa) OpenCicuitVoltage-V,(V) 35.25 35.53 35.71 36.08 33.4lbs/ft'(160DPa) 'Referminstallationmanual ShortCucuitCurrent-1,(A) 732 7.38 7.47 750 MaxSenes Fuse Rating: I5A Nominal operatingcell temperature N0CT(800W/m',AMIS,windspeedl m/s,amblenttemperature 20'C). Max Reverse Current: 15A oSH� / / /,\ 2year linear oweranty.outp Dimensions: 651/fz39x3//fin = 5 (`C �O�E (m x.de ressi power pert rmanceanty Area: 173/+h' (max.degressianin perfarmanceof0.7%p.a.). Weight: 391/21bs UL7703,-Fire dassin eg [ation Type IEC61215,IEC61730: Note! All given specifications are subject to change "2 IEC617al(Selt Misr-smwtylevelsl&6) without notice at anytime. REC is the largest European brand of solar panels,with more than 15 million high-quality panels produced at the end of 2014.With integrated a�rr manufacturing frompolysilicon to wafers.cells,panels and turnkey solar solutions,REC strives to help meet the world'sgrowing energy needs. REC In partnership with a sales channel of distributors,installers,and EPCs,REC panels are installed globally.Founded in 1996,REC is a Bluestar Elkemcompanywithheadquarters in Norwayand operational headquarters in Singapore.REC's 1,800 employeesworldwidegenerated revenues ofUSD680million in2014. www.recgroup.com NOTICE OF COMPLETION AND AUTHORIZATION TO APPLY THE UL MARK Sunrun South Llc, Dba Snapnrack 09/2412015 Greg McPheeters 775 Flero Ln Suite 200 San Luis Obispo Ca 93401,United States Our Reference: File E359313,Vol. i Project Number 4786982467 Your Reference: 14914 Project Scope: Adding REC Solar PTE. LTD.(NRTL)models: REC260, REC265, REC270, REC275, REC280,all followed by TP to Series 100 and 200 Mounting and Bonding Systems Adding Hanwha O.CELLS GmbH(NRTL)models: Q.BASE-GY XXX,Q.PRO-GY XXX, Q.PLUS-GYXXX,Q.PRO BFR-GYXXX,Q.PRO BLK-GYXXX,Q.PRO-GY/SC XXX,where Y is the generation number between 1 and 9,where XXX is the power output from 205 W to 295 W to Series 100 and 200 Mounting and Bonding Systems Dear Greg McPheeters: Congratulationsl UL's investigation of your product(s)has been completed under the above Reference Number and the product was determined to comply with the applicable requirements. This letter temporarily supplements the UL Follow-Up Services Procedure and serves as authorization to apply the UL Mark at authorized factories under UL's Follow-Up Service Program. To provide your manufacturer(s)with the intended authorization to use the UL Mark, you must send a copy of this notice to each manufacturing location currently authorized under File E359313, Vol.1. Records in the Follow-Up Services Procedure covering the product are now being prepared and will be sent in the near future. Until then,this letter authorizes application of the UL Mark for 90 days from the date indicated above. Additional requirements related to your responsibilities as the Applicant can be found in the document"Applicant responsibilities related to Early Authorizations"that can be found at the following web-site: htto:/IYwv-ul.com/EAReSDonsibilifies Any information and documentation provided to you involving UL Mark services are provided on behalf of UL LLC (UL)or any authorized licensee of UL. We are excited you are now able to apply the UL Mark to your products and appreciate your business. Feel free to contact me or any of our Customer Service representatives if you have any questions. Very truly yours, Reviewed by: Long Vo Bruce A.Mahrenholz 847-664-3009 Engineer Project Associate CPO Director Long.Vo@ul.com Bruce.A.Mahrenholz@ul.com NBKBDCB-1F9491 I This is an electronically generated letter.Signatures are not required for this document to be valid. Page 1 of 1 n MECHANICAL INSTALLATION .•2 FIRE t'U�ELtNES RECPeakEnsegy Serispanels have a CtassCType I Fire dasslficatim The lVeraft.ofthis pane!sonlyvatdwhenmaunt d to tf em3 nersoaCh?ed n thesemechanialmauntNgfnstn cdons.UtiGaethe following EtesahEygutdeGhe.vd en instatltng RECPeakEr ergyStrtespanals Checkwlthtocalauthoritiesfarfire rafetygutdelines andrequkementsfor any tndldingorst utare onto v"O thepane(swill beinsmile i Thes}siem design should ensure thaHtcan bs easilyacussed'inthe eventaf awWngtice, CheckweYhtacalautha itiesforappUcableregulat[onscancerntngsetkacksocotter pWcementrestrkttans[hatmay apply ForroniMwmKtdatays ^ Thause¢ffKgroundfaultintemtptetsorecammendedTnamaya(sabeeequired6�otacafandnaWaatcadas. • AllelechicalapptlatKesareafireriskThepaaelshaultlthere(acebemauntedo.�erafieeretardantmaimveringratedfortheappl'tcatia*an4a suitable dtstatmeof 4Wbetween thepanet and the mountingsurfaceaRowfngfreecircufationof atr beneath thepansts.shoutdhattspectedatalt tinter, ORIENTATkkf Ta maximuesystemoutpuCpanets sh¢uldbeinsal[eda[theoptlnwrnvrtenatianand tHEatgis,Thespedncs of this dependw 1vaEanandonae catcutatedbya quah@edsystemdesgw,,Atower angte of paWlasaUbtfactinmases Uierequirentantforceguie dea(iN. The optimalmouri tttgposidanof panelsresultsht the sun§raysfallingpetpeadicu[ar((e.at90•j to the surface.Adpanets inn stringshoutd,W+ecever passible have thesameorienatian andtfl[to entire Ne systemdoesnatunderperfcrmdue to mismaEchedoutputs, Thspaneis tmrstnoiheatpasal.varamcWify wnoan:aeecfsurltghe ' ENVIRON MENTAL FACTORS RECPeakEneryrySeriespattelsaredestgned to providedecadesaf doable and stabteoutput Operadngtemparattaesshauidbe between•40and 105•F (-00 and i-&SCI. The panels are not suitable forinstalladon in potentially hazardoustoatioastwr should theybe Installed In the fallowing locations, • Near sources of flammable gases orvapars • Nearopere0ames. • Underwatercrinrvaterfeatures. WtI eexposed to sufte¢near sulfursprings ccvolannes. • Wherethepane(s maybe exposed to harmfulchemiafs; t Ensma panels amnot exposed todirectcamaetwUh sairwaeerlspray and amid htstallationirramasatbjea to highsalemfscconte�a.g. c¢astelareas. PANECHANl)UNG Panelssboutdbehandledwithcare.Allwarn gsmdtnstructbiT.ortthepadm tgshoukfbeobserved FolfmvtheseguldelineswhenumecM:g transporting or storing the panels • RecordtheserWtmtmberspriortoNstalWtionand note the.informationbthesystemducumenattom • Carrythepanetsusfngbothhandsindavotdusingthefuncttuaboxasa,grip. • Do not allow the panelstosagarbawuuderthefrovm welgh[whenbeingarded. • Do not subjectthepaoelstoloadsorstressese,g,lea&gorplacing,heavyobjectsmtherm • Donotstandonthapane(serausekapactthmughdropp(ngthem. Keepa(f electrlal contacts clean anddrK • Storepanetslna dry andpruperlyventilated mom. • Donot apply force tathebadcsheet • Avoldusing sharp orpofntedahfectstFpaneisrequiremarkiog. • Neverappiypalnte,adhestvasardetergentsto the backafthelaminate. • Oonotusemysolarpanelthat(sdamagedarbeentampefed:with. • Neverattem ittodisassembtethepanets, ' fEtfrepaaetfmntglass is hr+otenor6amfnote hadtsheetis damaged,Itarteapase Qarsonnaltvhazardans wltages. a•�£a..eL �.t•txv 9/29/2015 Series 100 UL&Series 200 UL I SnapNrack Our system just, • • •ur UL 3 Listed SySteM is • • lass A Fire Rated fdr Type I & 2 modules M ' t ' LEARN MORE L— r� �, _. -��{C�L"Cr y 1 �Jc � � i�-�7'r,,•F� :i (� UL 2703:Class A Fire Rating Compliance In addition to grounding and bonding,the roof mount system,Series 100 UL,is Class A Fire Rated when installed with Type i and Type 21 Modules. SnapNrack's UL 2703 Certification and Compliance ensures that SnapNrack partners can continue to provide the best in class Installations in quality and safety. SnapNrack achieved our Class A Fire Rating through stringent testing that included the Spread of Flame tests and the Burning Brand tests.This achievement certifies that the SnapNrack Series 100 UL system maintains a Class A Fire Rating when installed with Type I and Type 2 modules. This also ensures that the system meets the requirements of the California Building Codes set by local jurisdictions and the 2012 International Building Codes which became mandatory on January 3,2015. M.dula type rlaatrications are dNermined by conswuian apeduwtans.and at.^suas lNmugh use UL 170s Ln ia,.Mare nntom:ndan an the requlremenu for Vasa Afim mon,x Li lmm.and VI. ]Ipa can Le GmndA ate rnilmvNRta'ebsac:MrpJ,nsvnvsoLanbcs.osylabouVpnblioeWrsmporlaglanunabllityieatM1grutls�.Mat iU1 SnapNrack_Series_100 Brochure.pdf M 42 KB it SnapNrack Series 100 UL Installation Manual.pdf 1798 NIB J'SnapNrack Serles_200_Brochure.ptif 138 M8 rl 5200 Install Manual.pdf 8.93 hill 'S SnapNrack_ConversionSheet.pdf 313.34 KB FJ SnapNrack_UL_2703_Fire Classification TedL_Bulletin.pdf 1.09 NIB SnapNrack Series 100 UL&200 UL System Identification Technical Bulletin.pdf 375.04 RB �ll SnapNrack Series 100 UL Certificate of Compliance.pdf 33182 KB Di SnapNrack Series 200 UL Certificate of Compliance.pdf 331.81 RB 91 mis Series 100 UL&Series 200 UL I SnapNrack Call us: 877-732-2860 Snag ,"rack- Residential, Configurel'oursystem• Whereto➢uy Resources, About- home.Resources•SedM 1m ULffi Sedea 20a UI. Series 100 UL & Series 200 UL UL 2703: Grounding and Bonding Compliance At SnapNrack we have expanded our product Une with our new Series 100 UL and Series 200 UL.➢ull%systems are fully fisted to the UL 2703 Standard for Grounding and Bonding,with the Of.listing,all system components bare been certified by UL for electrical continuity.eliminating the need for additional grounding hardware. If there ever was the situation where a lire conductor contacted a metallic component of the mounting system or array,the array would remain imenergized. New Features of Series 100 UL and Series 200 UL Bonding pins are included in producl assemblies including module clamps and rail splices. eliminating the need for bonding washers or splice jumpers. SnapNrackgrounding lug is a fully custom solution for grounding the mnipleted system. Only one lug is required per individual row of modules(not per mill.The lug is secured with a single 5ilT bolt just like every other component in the system and requires no drilling of derail„ L LISTED A key component of the listing is our new bonding channel nuts,which provide electrical continuity into our anodized rails. PV mounting System 2703 Mill finish specification on key components such as standoffs and metal roof seam clamps. Benefits of Series 100 UL and Series 200 UL The UL 2703 Luting is a huge benefit to distributors and installers of SnapNrack product.A rew benefits include: A Fully Certified System The entire system,including all components,is now bonded together.In other mounting systems on the market,some clamps,rooranchors. flashing&etc.aren't truly bonded to ground,and therefore not fully code compliant. Overall Reduction in Material Costs With the UL Listed product,we have added features into our components that ensure an adequate banding path,and In turn this has eliminated the need for grounding lugs and washers at each module.and bonding jumpers between splices. Dramatic Reduction in Labor With the elimination of grounding and bonding jumpers on the army,installations should have a dramatic improvement in efficiency.reducing installations by 1 hrikly or more. Quality&Safety SnapNrack installations using our UL product ensures that even metallic component on the system is banded to ground the system See below for a library of supporting documents to help assist with ordering and installing Series 100 UL and Series 200 UL. solar - SolarEdge Single Phase Inverters For North America SE3000A-US / SE380OA-US / SE5000A-US / SE6000A-US / SE760OA-US / SE10000A-US / SE1140OA-US xpv erte, �1225 veean�Y n c�Ylart � h ' � Q A e The best choice for SolarEdge enabled systems Integrated arc fault protection (Type 1)for NEC 2011 690.11 compliance — Superior efficiency(98%) — Small, lightweight and easy to install on provided bracket — Built-in module-level monitoring — Internet connection through Ethernet or Wireless — Outdoor and indoor installation — Fixed voltage inverter,DC/AC conversion only — Pre-assembled Safety Switch for faster installation — Optional—revenue grade data,ANSI C12.1 USA-GERMANY-ITALY-FRANCE-JAPAN-CHINA-AUSTRALIA-THE NETHERLANDS-ISRAEL www.solaredge.us Single Phase Inverters for North America solar=@@ SE3000A-US/SE3800A-US/SE5000A-US/SE6000A-US/ SE760OA-US I SE1000GA-US/SE114DOA-US _ SE3000A-US SE3800A-US SE5000A-US ISE6000A-US I SE760GA-US I SE10000A-US SE11400A-US OUTPUT Nominal AC Power Output 3000 3800 5000 6000 7600 9980 @ 208V 11400 VA ........................................ ... ........... .............. ................ .................................10000 @240V. ................. .......... 5400 @ 208V 10800 @ 208V Max.AC Power Output 3300 4150 6000 8350 12000 VA ........................................ ...............L............, 5450�La 240V. L...............I 10950 @24DV. . L..-...... AC Dutput Voltage Min:Nom:Mau.'° 183-208-229 Vac .L. ..... .............. ..... ... ............... AC Output Val[age Min:Nom:Max."l ✓ J ✓ ✓ ✓ ✓ J 211-240-264 Vac L.............L._............ .................L.............. L......... ...........*n'c*y ....................... ............ . ................................ .. .. AC Frequency Min:Nom.-Maz."' 59.3 (with HI country setting 57;60:60.5) Hz Max.Continuous Output Current.....L....1?.5..... I......1.......L,21 @ 240V..L.....25......L.....3?......L..?2.�1p.240V... ......47.........L...Q.... GFDI ................ ................................ ................. .................i... Utility Monitoring,Islanding Protection,Country Configurable Thresholds Yes INPUT Recommended Max.DC Power"' 3750 4750 6250 7500 9500 12400 14250 W .................................. .............. ................ ...--........... .............-.. ................. ......-.......... ......... Transformer-less,Ungrounded Yes........... .......................... Max, .... ...... 1age.._................ ............... .............. ................ �......500 L..Vdc... Nom.DC Input Voltage 325 @ 208V/350 @ 240V Vdc 16.5 @ 208V 33 @ 208V Max.Input Current'" 9.5 13 18 23 34.5 Adc ..... ............... .............. .15:5.@.240V.L.............. ......--....-... . 3....{,1°.240V.. ............... Max.l nput Short Circuit Current, ........... ............ ................ ........q5..... ._,.. Adc_. .... .. ........... ................. ................. .... Reverse-Polarity Protection Yes IloSe...................... ................. .................I Ground-F... ...Isolation Detection ............... . ...... . ............... 6001�Sensi[ivitY. . ...,...... ................. Maximum_Inverter.Efficiency.......... .....97:�..... .....98:?..... ......983....-.L....98.3.....i......98...... L......98....... .......... .....i.... .... 97.5 @ 208V 97 @ 208V CEC Weighted Efficiency 97.5 98 97.5 97.5 97.5 % .............. _............I..98,@ 240V..I. ................ . 97:5.�.240V.. ................. .... .... ........................................ ............... N ighttime Power Consumption <Z.S <4 ADDITIONAL FEATURES Supported Communication Interfaces RS485,RS232,Ethernet,ZigBee(optional) ........................................ .............- .... ................................ ................. ................. .......... Revenue Grade Data,ANSI C12.1 ............... .............. ................ ... Optional"'..,-..-... ......... .Rapid ................................. .............. .. n kit is installed"' ...... ................. Rapid Shutdown—NEC 2014690.12 Functionality enabled when SolarEdge rapid shutdown k't's'nstalled191 STANDARD COMPLIANCE .S.a.f.e.l.y....... ........................ UL1741,UL16998,UL19 98,CSA 22.2 ti.. s .... ................ .. ................. ..... . - - .. G : neco E- .... ... 48 .......... missions F arti5 class INSTALLATION SPECIFICATIONS AC output contluit size/AWG range 3/4"mimmum/16-6AWG 3/4"minimum/8-3 AWG ..Crop. conc...'si,ze ................ ................ ................ ................. ......... DC input conduit size/d of strings/ AWG range 3/4"minimum/1-Z strings/16-6. ...AWG 3/4"minimum/1-2 strings/14-6AWG Dimensions with Safety Switch 30.5 x12.5 x7/ 30.5 x12.5.z 7.5/ in/ .(.......1.............................. ...... ......315 x172 775 x,315x 191,. .. .:..,....,30.5 x 12.5 x10.5/775 x315 x260 Weight 775 x 23 . ........I I -,turn.„ Weight with Safety Switch.. .......... ......... SL2/23,2-...._,..L...._.. 54,7/24.7,.....,.. --.__.,..._..... ...BS.4/40.1 _ .,..,.. Cooling Natural Convection Fans(userreplaceable) .. . . ... .... .. Noise <25 <50 dBA Min.-Max,Operating Temperature Range, -13 to+140/-25 to... (40 to+.. version ...... .... F/-C Protection Rating . .,.., NEMA 3R ........................................ ...... .............. ................ ................................ ................. ................. .......... "I For othe,'pS'onal sehings please conlazt 5olarEd6e support. GmRed to 125%for loodoes where the yearly average huge temperature a above PI'F/b'Card m 1359r for locations where a In below,77'F/2SC For detailed information,infer to hnm//w rd INI4 f/" d d df A higher current source may be used;the inverter will limit as input current nine values staled. ullievenue grade inverter P/N:SEx.xxF US000li 'sl Rapid shutdown Fit PIN:SE1000 RSD 51 'o A(J version PIN:SEleW-USOOONNW ESUDSPECRoHS r 0 SelarEdge Technologies,Inc.All rights reserved.SOLAREDGE,the SolarEdge logo.OPTIMIZED BY SOLAREDGE • solar, N SolarEdge Power Optimizer Module Add-On For North America OP250-LV / OP300-MV / OP400-MV / OP400-EV • • i a Warcaarl _ aOv,� • x i PV power optimization at the module-level — Up to 25%more energy — Superior efficiency(99.5%) — Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading — Flexible system design for maximum space utilization — Next generation maintenance with module-level monitoring — Module-level voltage shutdown for installer and firefighter safety USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - ISRAEL - AUSTRALIA www.solaredge.us solar=ee SolarEdge Power Optimizer Module Add-On for North America OP250-LV/ OP300-MV/ OP400-MV/ OP400-EV OP250-LV I OP300-MV I OP400-MV I OP400-EV INPUT — RatedInput DC Power* 250 300 4.00 400 W........................................................ ............ ..................... ........................................................................... Absolute Maximum Input Voltage(Voc)..................._.. ....................5..........L....... 75._..,-..I-.......75........L.......125........L.. Vdc_... MPPT Operating Range..........................................�.......5.:5......... .......5.:7.........�.......5.:75.......�.....15-125.....�... Vdc.... Maximum Short Circuit Current(Isc)of connected PV 10 10 10 7 Ad Module ..................................................................... ..................... ........................................ .................................. Maximum DC Input Current...-- - -.-,. •. ..... ............. ........12;5,,,,,,,L......125..... 12.5 I :8.75 Adc . . ............................................�............ Maximum Efficiency 99.5 % .... .. .......................................... .........................................�............ eig Whte. d E.ffi...ciency.................................................. 98,8 Overvoltage Category II OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING INVERTER) Ma.xi....mum Outpu..t.Curr. ....ent 15 Adc. . . . ........................................ ..................... ..................... ...................................................... Operating Output Voltage 5-60 Vdc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM INVERTER OR INVERTER OFF) Safety Output Voltage per Power Optimizer 1 Vdc STANDARD COMPLIANCE EMC FCC Part15 Class B,IEC61000-6-2,IEC61000-6-3 ...f................................................................ ..................... .......................................... .....................I-........... Safety IEC62109-1(class II safety),UL1741........................................................... .......... ..................... ..................... ................. Material .... ................................. ................................................................. . UL-94(5-VA),UV Resistant RoHS .................... ..................'Yes................... ...................... .......... INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc .... .. .............................. ................... ..................... ................................. ..................... .. Dimensions(W x L x H) I 143 x 210 x 45/5.63 x 8.26 x 1.75 mm/in ............. .. ... ................................................ ..................... ..................... ..................... ........................... .I;.. Weight.............. .. .................... ............. ....... ..................... ............... 450/.1:0..........-..... ..................... ..gr/Ib... Input Connector................................................. ..................... MC4/Tyco/H+S/Amphenol—H4.....................�..--........ Output Wire.Type.................. ............................. ..................... ...Double insulated;,6mm'.MC4.... ....................�............ Output Wire Length 0.95/3.0 0.95/3.0 ( 1.2/3.9 1.6/6.. . m/ft ..................................................................... .......................................... ....................................... ....... . . .... Operating Temperature Range.................•.,,,.,,.,,-..-, ......_. .---,-..:40-+65/:40-+150 ..'C/.F_- Protection Rating IP65 NEMA4 ..................................................................... ............... Relative Humidity 0-100 % ........ .................................................. .......................................... ...................................................... mated sTC poaet of the module.Module of up to+5%Power tolerance allowed. PV SYSTEM DESIGN USING A SOLAREDGE INVERTER SINGLE PHASE THREE PHASE 208V THREE PHASE 480V Minimum String Length(Power Optimizers) 8 8 18 . ................................................................... ............................. ............................. . ............. ..... Maximum String Length(Power Optimizers) I 25 ZS I 50 ............................................................. ....... ............................. ............................. ............................. ......... Maximum Power per String 5250 6000 12750 I W ..................................................................... .......................................................... ............................. ......... Parallel Strings of Different Lengths or Orientations Yes ....... .... ........................ .. ...... .............. ........ ... . .. . . ...... ......... OPTIMIZED'rQ Sclar�dgo rechnolDgie.%.Inv.,All rights reserrad.SOI.AREDGE,the ScislEdge 1090, badennel,s of their respective asneet.Date:am bradernarles or registered trademarks of SolarEdge Taclihologies,Inc.All other undernarks mentioned herein am s N/ All Flgp ku. i OpenWay@CENTRON° Cellular LTE The smart meter for the smart grid,the OpenWay CENTRON, is now available with an LTE Itron Cellular Module(ICM).This integrated OpenWay Cellular solution provides a complementary communication pathway by incorporating WAN functionality—under the OpenWay CENTRON meter cover—to connect the meter directly to the OpenWay Collection Engine via a public wireless network. The OpenWay CENTRON Cellular LTE FEATURES AND BENEFITS Automated Interval Data/Energy takes advantage of new advanced 4G Usage Retrieval LTE networks. This results in more Flexible Two-Way Communications Receive and transmit meter interval efficient coverage,higher bandwidth and Execute all supported reading, data for up to four unique energy values longer network longevity.The OpenWay configuration and firmware download in intervals as small as five minutes. CENTRON Cellular LTE includes both a functionality through user-configurable Recorded events and exceptions with ZigBee®wireless component and an LTE schedules controlled by head-end meter each interval are also transmitted to the ICM that can be tailored to fit your unique data management software head-end software,which interprets needs.The module comes factory installed » Acquire readings on an on-demand basis them and logs appropriate messages within the OpenWay CENTRON meter—the when necessary (such as time adjustments) solution ships as one complete unit,ready for field deployment. Pushing Intelligence to the Edge energy flow and power outages.The Perform remote disconnects through Enable future applications in edge OpenWay CENTRON Cellular LTE the Collection Engine by retrieving a final intelligence by utilizing on the newest architecture provides the power outage read for a customer and then an initial Itron Rive technology platform.By notification(PON)and tamper associated read for a subsequent customer pushing computing power to the edge with a meter removal immediately Allow service to be disconnected or devices,closer to where problems and upon power down.This results in two reconnected remotely as well via a opportunities occur,we enable faster, exception messages upon power down, load-limiting service switch in the meter, better decision making. PON and Removal tamper. eliminating the need to roll a truck to turn Automated Register,Self-Read and Secure Boot service on or off TOU Retrieval The OpenWay CENTRON Cellular LTE 900 MHz ERT Reader Configure the module to read and has the capability to validate digital „ Collect Encoder Receiver Transmitter transmit totals,self-reads,maximum signature prior to uploading and applying (ERT)from 100G DLS Gas Modules. demand,time-of-use(TOU)and critical any new ICM firmware. The ICM can collect consumption data peak pricing(CPP)values and tamper counts from nearby Bi-Directional Metering y 1 OOG Demand Reset tY Support bl-directional net metering Capability ERT modules and report this back to the P Collection Engine and other upstream Perform demand resets,over the with the OpenWay CENTRON.Both network or locally via tools or the received and delivered data metrics are systems. demand resert switch stored in the meter and can be sent to Clock Synchronization the utility as needed to support green- Synchronize the meter clock Power Outage and Restoration Alarms credit electricity programs for consumers automatically when time deviation falls u Transmit a real-time"last gasp" who own renewable energy facilities or within a user-defined boundary notification when detecting an AC power participate in vehicle-to-grid systems outage with built-in ultracapacitor energy Integration&Installation storage.The meter then notifies the Automated ID Tracking Ensure simplified installation in the field. head-end when the AC power is restored Attach barcode labels and important The ICM is a fully integrated,under- identifiers(such as the ICC-ID/MS- the-cover option installed within the Service Diagnostic and Tamper ISDN)to the integrated module for Detection Alerts OpenWay CENTRON.The solution The OpenWayCENTRON Cellular LTE tracking and troubleshooting purposes is shipped from the factory as one can detecctt and report exceptions for On-Demand Reads for Move In/Outs complete unit with the module installed, meter inversion,meter removal,reverse and Remote Disconnect ready for field deployment. Remote disconnect available on all singlephase Class 200 devices HARDWARE CPU board(CPU) 32-bit ARM processor,128MB RAM,256MB flash Capacitor Storage Bank ICES) Supplies power for data transmissions and all functions for outage notification ICM Modem Modem communicates with head-end using LTE and SMS Services ZigBee Transceiver Enables communication with Home Area Network (HAN)devices Singlephase:Flexible dual frequency on board internal antenna for the modem and ERT available on all Intemal/Extemal Antennas forms. Polyphase:Multi-band internal antenna with diversity.External Omni Directional antenna for modem available on all polyphase fors. Tilt Detector Detects unauthorized movement or removal of the device INPUT/OUTPUT SIGNAL ICM Power Input Voltage Singlephase:120.240 VAC I Polyphase:120-480 VAC Capacitor Storage Bank(CSB) 3.3V/TTL compatible asynchronous ERTReader 900 MHz radio supports 100G Gas and 100W+Water endpoints VERSION AND COMPATIBILITY Meter Hardware Version 3.1 Meter Firware Verson Singlephase:SR 6.1 or higher I Polyphase:SR 6.6 or higher OpenWayTools Compatibility Singlephase:4.00.91 or higher I Polyphase:4.20.00 or higher OpenWay Collection Engine Compatibility Singlephase:SR 6.1 or higher I Polyphase:SR 6.6 or higher SPECIFICATIONS Regulatory and Industry Specifications Humidity Range Carriers Supported FCC Part 15 Class B ° 0%to 95%non-condensing ° Verion Wireless ANSI C37.90.1 —1989:(SWO) Accuracy ° Rogers Wireless ANSI C12.20(Class 0.5)—1998 ° Meets ANSI 12.20 for accuracy » PTCRB Certified class 0.5%(Singlephase)and 0.2% Network Carrier Certified (Polyphase) Measurement Canada Certified ° Optional Singlephase Adder:0.2% Industry Canada Certified Accuracy Class r, UL2735 Supported Meter Forms Temperature Range: Singlephase without Disconnect ° Operating:[-40°C,+85°O) » CL 200: 1S,2S, 12S,25S ° Transmission(wireless):[-30°C,+70°C) ° CL 320:2S Singlephase with Disconnect „ CL 200: 1S,2S, 12S,25S Polyphase CL 20:3S,4S,9S,9S/36S,45S CL 100:1S CL 200:2S,12S,16S n CL 321 12S, 16S CORPORATE HEADQUARTERS Join us in creafing a more resourceful world. 2111 N Moner Road To learn more,visit ttron.com U6erly fie,WA 99019 USA VJhiellmnstrrvaslo makatheconlent olilsmarketingmalerialsaslimelyantlaccuraleaspossibk,gronmakesnocleims.promises, Phone: 1.800.635.5461 ogaranteasaboul the accrcy campleleess,patleuyol,antlepresslytlscams fmGlilbrensa ome0 sln.such lmaeawn , , pe , mn ehne rugmlolthtrd Fax 1.509.891.3355 partynghls.Nle,mercl»nlabitily,aMfilnesslarapanicvWrpurpose,Isgrvenwilnrespec11o1heconlentollhesamarhalingmaterials. 0Copyrigh12015.ft,M.Allrghhmaemec,101407SP-058r15 Snap rack UL LISTED PV Mounting System 2703 F . - i Zp c 4 ./,j 'I K _ SERIES • • UL ROOF MOUNT SnapNrack ResidentialMounting Systems - Code • • Installation QIMS.E359313 -Mounting Systems,Mounting Devices, Clamping Devices and Ground ... Page 1 of 2 UL 9ULINE CERTIFICATIONS DIRFcTogy QIMS.E359313 Mounting Systems, Mounting Devices, Clamping Devices and Ground Lugs for Use with Photovoltaic Modules and Panels Page Bottom Mounting Systems, Mounting Devices, Clamping Devices and Ground Lugs for Use with Photovoltaic Modules and Panels See General Information for mount'-no mount'-no Systems.mountino UliviCes,Clamoina Devices d Ground Was for Use with Photovoltaic Modules and Panels SUNRUN SOUTH LLC,DBA SNAPNRACK E359313 775 Flem Ln Suite 200 San Wls Obispo,CA 93401 USA Investigated Investigated for System Fire Cat, for Mechanical Classification No. Bonding Loading (A,B or Q Tested in Combination With Photovoltaic mounting system Series r N - UL Listed PV Modules: 350 REC Solar AS:REC214,REC215,REC22O,REC2.25,REC230, REC235,REC24O,REC245,REC25O,REC255,REC260,REC265, REC27O,all followed by PE,PE(BLK),PE-US,PE-US(BLK),PE Q2 or PEQ3. Hyundai Heavy industries Co Ltd: HIS-MxxxMG Series-HIS-M21OMG,HIS-M213MG,His-M215MG,HiS- M218MG,HIS-M22OMG,HIS-M223MG,His-M225MG,HIS-M228MG, HIS-M230MG,HIS-14233MG,HiS-M235MG,HIS-1,1238MG,Hi5- M240MG,His-M243MG,HIS-1,1245MG,HIS44246MG,HS-M25OMG, HIS-M253MG,HIS-M255MG,HIS-M258MG,HIS-M260MG,Hi5- M263MG,HIS-M265MG,HiS-M268MG,HIS-14270MG; HIS-SxxxMG Series-HIS-S220MG,HiS-S223MG,His-S225MG,HIS- S228MG,His-5230MG,HIS-5233MG,HiS-S235MG,HIS-S23BMG, HIS-5240MG,HIS-S243MG,HIS-S245MG,HIS-S248MG,HIS- S250MG,HIS-S253MG,HiS-S255MG,HIS-S258MG,HIS-S260MG, HiS-S263MG,HIS-S265MG,HIS-S268MG,HIS-S27OMG,HIS- 5273MG,HIS-5275MG; all may be followed by the suffix BK or blank. Renesola Jiangsu Ltd:JCxxxM-24/BB Series-JC200M-24/8b, JC2O5M-24/eb,3C230M-24/Bb,1C215M-24/Bb,3C22OM-24/8b, JC225M-24/8b,JC23OM-24/Bb,JC235M-24/8b,JC2401,1-24/13b, JC24SM-24/Bb,JC250M-24/Bb,JC255M-24/Bb,JC26OM-24/Bb, Series Y N - JC265M-24/Bb,JC27OM-24/Bb. 100 Suniva Inc-MVX-235-60.5-701,MVX-240-60-5-701,MVX-245-60- 5-701,MVX-250-60-5-701,MVX-255-60-5-701,MVX-260-60-5-701, MVX-265-60-5-701; MVX-235-60-5-781,MVX-240-60-5-781,MVX-245-60-5-781,MVX- 250-60.5-781,MVX-255-60-5-781,MVX-260-60-5-781,MVX-265- 60-5-731; OPT-250-60-4-800,OPT-255-60-4-800,OPT-260-60-4-600,OPT- 265-60-4-800,OPT-270-60-4-800,OPT-275-60-4.800; OPT-250.60.4-880,OPT-255-60-4-88O,OPT-260-60-4-880,OPT- 265-60-4-850,OPT-270-60-4-BB0,OPT-275-60-4-88O. Yingli Energy(China)Co Ltd-YLXXXP-29b Series-YL215P-29b, YL220P-29b,YL225P-29b,YL23OP-29b,YL235P-29b,YL24aP-29b, YL245P-29b,YL250P-29b,YL255P-29b,YL260P-29b; YLXXXA-291b Series-YL22OA-29b,YL225A-29b,YL230A-29b, YL235A-29b,YL240A-29b,YL245A-29b,YL250A-29b,YL255A-29b. Trina Solar Ltd-TSM-215PAO5,TSM-22OPAO5,TSM-225PA05,TSM- http://database.ul.com/cgi-bin/XYV/template/LISEXT/IFRAME/showpage.html?name--Q... 1/13/2015 j QIMS.E359313-Mounting Systems,Mounting Devices,Clamping Devices and Ground ... Page 2 of 2 Series Y N — 230PAOS,TSM-23SPAOS,TSM-240PAOS,TSM-24SPAOS,TSM- 200 250PA05,TSM-255PA05,TSM-260PA05; TSM-215PA05.05,TSM-220PA05.05,TSM-225PA05.05,TSM- 230PAOS.05,TSM-235PA05.05,TSM-240PADS.OS,TSM-245PA05.05, TSM-250PA05.05,TSM-25SPA05.05,TSM-260PA05.05; TSM-2ISPA05.08,TSM-220PA05.08,TSM-225PA05.08,TSM- 230PA05.08,TSM-235PA05.08,TSM-240PA05.08,TSM-245PA05.08, TSM-250PA05.08,TSM-255PA05.08,TSM-260PA05.08; TSM-215POOS,TS14-220PDOS,TSM-22SPD05,TSM-230PDOS,TSM- 235PD05,TSM-240PDD5,TSM-245P005,TSM-250PDD5,TSM- 255PDOS,TSM-260PD05; TSM-215P1305.08,TSM-220PDOS.08,TSM-225PD05.08,TSM- 230PDOS.08,TSM-235PD05.08,TSM-240PD05.08,TSM- 245P005.08,TSM-250PD05.08,TSM-255PDOS.08,TSM- 260PDOS.08. NRTL Listed PV Modules: Hanwha SolarOne:Models HSL60P6-PB-2-230Q,HSL60P6-P8-2- 2350,HSL60P6-P5-2.240Q,HSL60P6-PB-2-245Q,HSL60P6-PB-2- 250Q,HSL60P6-PB-2-25SQ,HSL60P6413-2-260%HSL60P6-PB-2- 2650,HSL60P6-PB-2-27DQ; HSL60P6-PB-4-230%HSL60P6-PB4-235Q,HSL6uP6-PBi-240% HSL60P6-PB4-245Q,HSL60P6-P84-250Q,HSL60P6-PB4-255Q, HSL60P6-PB-4-260Q,HSL60p6-PB4-265Q,HSL60P6-PB4-270Q; may be followed by additional suffixes. Suniva Inc-OPTXxX-6O-4-YYY, where XXX may be numbers 240 to 270 In increments of 5; where YYY may be 100; OPTXXX-60-4-YYY; where XXX may be numbers 235 to 265 in Increments of 5; where YYY may be IBO. Series j N j N A j Type 1 PV Modules 100 Trademark and/or Tradename:"SNAPNRACK" Lest Undated on 2014-08-26 Ouesdons7 Print this oaae Terms of Use pane ho ®2015 UL LLC When the UL Leaf Mark Is on the product,or when the word"Environment"Is included in the UL Mark,please search the UL Environment database for additional Information regarding this produc s certification. The appearance of a company's name or product In this database does not in Itself assure that products so identified have been manufactured under UUs Follow-Up Service.Only those products bearing the UL Mark should be considered to be Certified and cowered under ULs Follow-Up Service.Always look(or the Mark an the product. UL permits the reproduction of the material contained In the Online Certification Directory subject to the following conditions:1.The Guide Information,Assemblies,Constructions,Designs,Systems,and/or Certifimbons(files)must be presented in their entirety and In a non-misleading manner,without any manipulation of the data(or drawings).2.The statement"Reprinted from the Online Certifications Directory with permission from UC'must appear adjacent to the extracted material.In addition,the reprinted material must Include a copyright notice In the following format:"®2015 UL LLC. http-//database.ul.com/cgi-bin/XYV/template/LISEXT/1 FRAME/showpage.html?name—Q... 1/13/2015 SERIES • • UL ROOF MOUNT SolarSnapNrack Solutions The SnapNrack line of solar mounting solutions is designed to reduce total installation costs. The system's technical innovations have been proven to drive '=1 down costs and improve installation quality on more than 350 MW of solar installations. — Pitched Roof Arrays Simplified The SnapNrack Series 100 UL Roof Mount System is an efficient, visually appealing, photovoltaic(PV) - >.:.._,. module installation system.Series 100 UL is Listed to the UL Standard 2703 for Bonding, meaning that all system components have been Certified by UL for Roof System in 4 Simple Steps: electrical continuity, eliminating the need for additional 1) Go to the online Series 100 Configuration grounding hardware.The System's components provide Tool (configure.snapnrack.com) and select an adequate bonding path which has eliminated the "Yes" for UL 2703 Listed need for grounding lugs and washers at each module, and bonding jumpers between splices. The UL 2703 2) Identify Site Conditions (Array Tilt, Building Listing ensures that SnapNrack partners can provide Height. Roof Type, Wind and Snow Loads) the best in class installations in quality, safety,and 3) Build array in the online Configuration efficiency. Tool and automatically generate a Bill of • All bonding hardware is fully integrated into the Materials. components 4) Place order with your distributor. Purchase material for a single project or order in bulk • No grounding lugs required for modules for additional savings • Rail splices bond rails together, no rail jumpers required • Proprietary SnapNrack grounding lug snaps in the rail channel, no drilling of rail or reaching for other tools required (One Lug per individual row of modules) • Class A Fire Rating Type 1 and 2 modules eLISTED PV Mounting System Patent Pending 2703 Stainless Steel SnapNrack Bonding SnapNrack Standard Rail Stalnlessaoltwith Bolt with Split- `'� Splice Insert Split-Lwk Washer Lock Washer -SnapNrack Bonding ) Splice--SnapNrack Adjustable End - SnapNrack .0,��1.�,._ Clamp Top Bonding Base :'^m..-_.SnapNrack Mid Clamp --SnapNrack Bonding Bonding --Sna Nrack ^<, Channel Nut Adjustable End P Stainless bT Clamp Bottom , Bonding Stainless Hardware with Bolt with Channel Nut Split Lock � Split-Lock Washers SnapNrack Bonding SnapNrack Bonding SnapNrack Bonding Washer Adjustable End Clamp Mid Clamp Standard Rail Splice SnapNrack Ground Lug 10-6AWG- _ Copper Wire SnapNrack Ground Lug 1 — - -- Assembly _ ( (ONE REQUIRED PER ROW OF MODULES) r SnapNrack Bonding Universal End Clamp(UEC)Wave '=n ^'� •. . � \' -, �_ T-_l__ --UECPUIIStrap UEC Wedg¢ Stainless Steel Bolt r with Flat Washer SnapNrack Bonding Universal End Clamp SnapNrack - 7 Bonding _ i ZJ', Standoff Clamp Assembly Serrated Stainless _� _SnapNrack SneoNrack Bonding SnapNrack Channel Nut Steel Flan a Nut Bonding Rubber g —Stainless Channel Rain Collar � Flange Nu[ Serratreel Stainless— Nut Steel Flange Bolt -SnapNrack kF Stainless SnapNrack - 92 Degree Flange Mill Finish L Foot Bolt Standoff , - r���',."'iii—SnapNrack SnapNrack All Purpose Mill Finish L Foot Standoff t.�...� SnapNrack - SnapNrack Base(1-Hole / ;',3 SnapNrack Metal Roof Mill Finish �� Base Shown) Foot / FWshing Base Assembly L Foot Base SnapNrack Metal SnapNrack Bonding SnapNrack Bonding Roof Base with Standoff Assembly L Foot Base with Flashing Bonding L Foot SnapNrack • / Data Patent Pending Materials • 6000 Series aluminum • Stainless steel • Galvanized Steel and Aluminum Flashing Material Finish •Clear and black anodized aluminum •Mill Finish on select components Installation •Quick and efficient mounting •Adjustable hardware to ensure clean and level finish •All components bonded to ground with integrated bonding features Calcs-&Certifications • Listed to UL Standard 2703 for Grounding/Bonding and Fire Classification • Class A Fire Rating Type i and Type 2 Modules • Stamped Structural Engineering Reports for all 50 States Grounding • SnapNrack Grounding Lug(One Lug per individual row of modules) Warranty • 10 Year material and worksmanship(download full details at snapnrack.com) Snap rack- (877) 732-2860 www.SnapNrack.com 0 Printed on recycled paper using soy based inks. low to Configure Your System Series 100 UL rst calculate the spans and penetration count. There is Roof . - • System SnapNrack span calculation table on the back of this anual. Determine site conditions: general building height, Safety Guidance ray pitch, the wind speed, and snow load or topographical - Always wear the; proper • J approved mdition. Find appropriate railspan from table. safety equipment workingwhen on a roof pan Table Example - Safety equipment should be checked 3uilding Height 0 - 30 ft annually for wear and array Pitch 160proper eye protection. .012 IBC Wind Speed 120 mph - When walking on the roof avoid walking ;now Load 8 IbS/ftZ on installed rails. If this is unavoidable checl bpo. Cond. NonebeforeL-f !ail Span 104" - Appropriate fall protection gear should 'ail Span on 2411 spacing roof be 96" (8 ft) Extreme should ' used when - edge . - roof io edge/corner reductions apply Yes, shaded cell Age Zone Span 72" (6 ft) :orner Zone Span 24" (2 ft) 30 ft. Roof Height Table 1A:Rail Spans(in)for Roof Slopes and Tilt Angles 0-to 19' 6O63AIloy Wind Lwd \'ul1 IIU IIS 1'_a 1 UU 135 IJU IJS ISU 153 I(U 17U IXa 19U +1+ IS.S 149 IX.J _'U.0 -1.6 1 23.3 1 25.1 '_(9 ]%.X JU.7 32X 379 J1.3 41, U U -11x r uJ - p 31) ?3 ]c 1i7i 50 39 JA fill MI HI 60 0 6(I tel u « 5s s< ss ss ss » 55 a 5s .. 711 54 51 51 51 51 I 51 51 51 51 51 51 51 51 51 J .11 S-Consult ` J MODULE OVERHANG Notes tructural En ineer � (NOT TO EXCEED 25 I / �-�`F MODULE LENGTH) ! . RAIL SPAN RAIL END OVERHANG - (NOT TO EXCEED 34%OF .- ACCEPTABLE RAIL SPAN) S IIf ` SERIES 100 UL 1 200 UL IDENTIFICATIONSYSTEM SnapNrack Residential PV Mounting Systems September 2014 Overview The SnapNrack Series 100 UL and 200 UL are listed to UL Subject 2703 for Bonding, meaning that all system components have been certified by UL for electrical continuity, eliminating the need for additional grounding hardware. The electrical continuity is achieved through three (3) main features: • Stainless steel bonding pins inserted into specific contact surfaces between components • Mill finishes on specific components to reduce electrical resistance • Fasteners selected for improved bonding capabilities Because these features are difficult to identify once a system is installed this bulletin provides guidance on how to visually identify the Series 100 UL and 200 UL against other SnapNrack mounting solutions. Packaging Identification l Ur SnapNrack's primary recommendation for identifying a Series 100 UL or 200 UL system is to check the i IIJLIfAI�I`� component packaging. Since the individual components " urvao Y do not bear the UL label the packaging is intended to +�+* be the main identifier. It should be noted that Snap- , In Grounding Lug is stamped with the "GR" symbol, and no other components are marked with this symbol 1 _ as specified in UL Subject 2703, Section 8.4. This (Duna ; packaging should be kept on site and made available to inspectors to ensure there are no questions whether the — - components installed are part of the UL Listed system. Figure Figure 1 shows a typical package of twenty (20) Bonding Universal End Clamps bearing the UL Listing label. Boxes and other SnapNrack product packaging will bear the same UL Listing label for all Series 100 UL and 200 UL components. Product Identification The primary feature providing an electrical bonding path between components is a stainless steel pin installed on A some of the mating surfaces. A mounting system being installed with these bonding components will identify a Series 100 UL or 200 UL installation. Figure 2 shows the bonding pins installed at the contact surface of the Bonding Universal End Clamp on the right, j and the lack of pins in the non-bonding Universal End Figure 2 Clamp on the left. Since these pins are between mating surfaces of the Series 100 UL and 200 UL components it will be difficult to use these features as an identifier for installed mounting systems. The additional SnapNrack bonding components can be found in the SnapNrack UL Conversion Sheet. Figure 3 shows a feature of the Bonding Mid Clamp that can be used to identify a Series 100 UL or 200 UL system after the installation. The Bonding Mid Clamp has an open channel for the module spacer whereas the non- bonding Mid Clamp has a closed hollow feature. Also, non-bonding Mid Clamps will typically have a WEEB or similar grounding washers to bond the module to the rail. Since the UL 2703 Listing supersedes the requirement for J additional grounding washers they are not required on the Series 100 UL and 200 UL systems. Figure 3 UL LISTED PV Mounting System 2703 Snap rackw (877) 732-2860 www.SnapNrack.com This InlorTobw is Con`denlial cnd Propr etary.Any reprad ctian disdps re.ar use thereof is p+ppss y pmhibiled sv4hpuc vinL'pn eemmssipn of SnapNhack.In:. 0 2014 by SnapNrack PV Meuntmg System.All rights reserved. Friday,January 31,2114 SnapNrack ^®!(lllla� IOl�ll ���0 m O r m a n 775 Piero Lane,Suite 200 San Luis Obispo,CA 93401 (171 "Series 100 Roof Mount"Cover Letter cheeI To Whom It May Concern, We have performed calculations for the 100 series roof mount PV system based on t r u c t u r a I the information provided by SnapNrack.Included with this letter are the report and calculations.We did the calculations in accordance with the 2012 IBC,ASCE 7-10, 2012 NDS, and guidelines slated in the Solar America Board for Codes and Standards. Engineer Some of the components in the SnapNrack test data were used to determine the 5022 sunrise Blvd capacity and section properties of materials. We collected the test data using the FairOak:,CA 95628 procedures outlined in the 2012IBC Chapter 17. (916)536-9595 (916)536-0260(rox) We included the following types of load combinations and building parameters into 1989-2013 our Calculations: 1d years ojercti•/lerrec • ASCE 7-10 wind speeds from 110 mph to 190 for B and C exposure categories • ASCE 7-10 Seismic Design Category E • ASCE 7-10 Snow Loads up to 120 psf ground snow • Buildings with mean roof heights up to 60 foot tilt angles /roof pitches Norman Scheel,S.E. from 0 degrees to 60 degrees. LEED AP BD•C [ZED AP Homes The calculations have also been completed in accordance with the 2006IBC,2009 Fc fo,c-A CF! IBC and ASCE 7-05. To use the data contained in this packet for projects that are FellmvASCf; , E-mail:won0assemm being evaluated to the older ASCE 7-05 wind speeds,refer to Appendix A for a Rob Coon wind speed conversion chart. Find the ASCE 7-05(IBC 200612009)wind speed in Ocnrml Manager the Chart in Appendix A,identify the corresponding ASCE 7-10(IBC 2012)wind E-msa:roxom($n can speed value,and proceed with using the charts contained in this packet with the Steve Smith P.E. adjusted wind speed value. Proleci Manage E-rmil:aeaxcmi,hn nssecam In our opinion, the mounting system, outlined by SnapNrack Series 100 PV Mounting System Code Compliance Installation Manual, is acceptable and meets Steven Cooksey the loading requirements as stated above. See the report and calculations included CAD Supervisor E-mail:pna•<albssse.enm with this letter for more information. Jackie Winslow If there are any further questions,please contact Norm Scheel eFOf ESSlO Office Manage Eama:iadiernsse cn n Norman Scheel PE,SE 4w y Fy LEED-AP SD+C,LEED-AP Homes m Fellow SEAOC o-2567 Fellow A.S.0 * UP,1213111 S R�OFChLtFO� JAN 31 Z014 Series 100 Snap rack- Structural Report and Calculations Table of Contents Section Page Cover Letter 1 Summary Report 2 to 17 Building Department Support Calculations Calculations 0 to 30 ft.Mean Roof Height(6063 Rail) Cl to C15 Wind Calculations Velocity Pressures&MFRS Cl Component and Cladding C3 Seismic Calculations C7 Snow Loads C8 Rail Properties C9 65"PV Panel Connection to Rail C10 78"PV Panel Connection to Rail Cl 1 Lag Bolt Connection to Roof C 12 Rail Span Chart Tilt Angle 0-19 degrees C13 Rail Span Chart Tilt Angle 20-36 degrees C 14 Rail Span Chart Tilt Angle 37-45 degrees C 15 Rail Span Chart Tilt Angle 45-60 degrees C 16 Building Department Suppol4 Calculations Calculations 31 to 60 ft.Mean Roof Height(6063 Rail) C17 to C32 Wind Calculations Velocity Pressures&MFRS C17 Component and Cladding C19 Seismic Calculations C23 Snow Loads C24 Rail Properties C25 65"PV Panel Connection to Rail C26 78"PV Panel Connection to Rail C27 Lag Bolt Connection to Roof C28 Rail Span Chart Tilt Angle 0-19 degrees C29 Rail Span Chart Tilt Angle 20-36 degrees C30 Rail Span Chart Tilt Angle 37-45 degrees C31 Rail Span Chart Tilt Angle 45-60 degrees C32 NSSE 5022 Sunrise Boulevard Fair Oaks CA 95628(916)536.9585 Rev. 1213112013 Page 3 Series 100 Snap rack- Structural Report and Calculations Introduction This report describes, illustrates, and explains the Structural Calculation Packet for SnapNrack's Series 100 Mounting System, dated 4/12/2012. The calculations have been performed in accordance with the 2012 International Building Code(IBC). The racking system has been designed to withstand code-prescribed forces due to its own weigbt, the weight of the solar panels,the snow loads,and both the wind and seismic forces. Rail Spans This report covers two different material options for the system rails. Although they are both aluminum,one rail option uses a 6063 alloy(25 ksi yield)and the other uses a 6005 alloy(35 ksi yield). Despite having different yield strengths,both types of rails support the PV panels. As for the rails themselves,they are supported by mounting hardware which attaches them to the roof structure with spans that are expressed in inches. Refer to the tables below for rail spans under varying conditions of rail alloy and roof height. Shaded cells require an edge zone adjustment(see details following charts). Notes for Tables 1A thru 2H 1. Detennine the mean roof height, tilt angle, and rail alloy (if you are unsure, use the 6063 alloy values). For mean roof heights less than 30 feet, use Table IA/2A for tilt angles less than 19 degrees,Table 1 B/2B for tilt angles between 20 and 36 degrees,Table 1C/2C for tilt angles between 37 and 45 degrees, and Table ID/21) for tilt angles between 46 and 60 degrees. For mean roof heights between 31 and 60 feet use Table IE12E for tilt angles less than 19 degrees, Table IF/2F for tilt angles between 20 and 36 degrees,Table IG/2G for tilt angles between 37 and 45 degrees,and Table 1H/2H for tilt angles between 46 and 60 degrees. 2. Determine the wind and snow load for the project site from the building department. Make certain to use 2012 IBC wind loads. Locate the wind load in the table across top rows and the snow load down the left columns to find corresponding maximum rail span. 3. For snow loads,column Pg equals the ground snow. 4. Shaded cells require application of an edge zone adjustment(details to follow). r NSSE 5022 Sunrise Boulevard Fair Oats CA 95629(916)536-9585 Rev.12/312013 Page 5 I i Series 100 Snap rack- Structural Report and Calculations 0-30 fL Roof Height Table SC:Rail Spans(in)for Roof Slopes and Tilt Angles 37'to 45' 6063AIloy Wind Load Volt 110 115 120 125 130 135 140 145 150 1 155 160 170 180 190 qh 155 16.9 18.4 20.0 21.6 233 25.1 26.9 28.8 30.7 32.8 37.0 41.5 462 P6 Ps -6,7 -73 .7.9 -8.6 .93 .10.0 •10.8 -11_6 -I2.4 -132 44.1 45,9 -11.8 -99.9 0 0 120 120 120 120 120 120 116 III I06 I 102 98 91 85 80 1 `tea, 10 8 112 111 110 IN 108 107 105 IM 103 102 I 98 9I 85 SD e 20 IS 99 89 89 89 89 fl9 tl6 88 87 87 86 83 83 80 '4 30 23 75 75 75 75 75 75 75 75 75 75 75 75 74 7l 3 c 40 JI 66 66 66 66 66 66 66 66 66 66 66 66 66 66 m � 50 79 60 60 60 60 60 60 60 60 60 60 60 60 60 60 Q 60 46 55 55 55 55 55 55 55 53 55 55 55 55 55 55 70 54 51 51 51 51 51 51 51 51 51 51 51 51 51 51 80 62 48 48 48 48 48 48 48 48 48 48 48 48 48 48 100 77 43 43 43 43 43 43 43 43 43 43 43 43 43 43 120 92 40 40 40 40 40 40 40 40 40 40 40 40 40 40 0-30 ft.Roof Height Table 1D:Rail Spans(in)for Roof Slopes and Tilt Angles 46'to 60' 6053 Alloy Wind Load V01t 110 1 115 120 125 1 130 135 140 145 1 150 155 160 170 180 1 190 qh 155 16.9 18.4 20.0 21.6 233 25.1 269 28.8 30.7 1 32.8 37.0 41.5 463 Ps Pr 463 d9 .7.6 .82 .8.9 -9.6 .10.3 .11.0 -11.0 -17-6 .13A -153 -17.0 489 G` 0 0 120 120 120 120 118 115 I 113 I 110 1 107 105 101 94 I 88 82 5 10 g 106 Io5 104 102 101 100 98 97 96 94 93 90 In; 82 c 20 15 89 88 87 87 86 IS 84 83 82 B2 81 79 77 76 '4 30 23 75 75 75 75 75 75 75 74 74 73 72 71 70 69 3 rn 40 31 66 66 66 66 66 66 66 66 66 66 65 65 64 63 50 39 60 60 60 60 60 60 60 60 60 60 60 60 60 59 Q 60 46 55 55 55 55 55 55 55 55 55 55 55 55 55 55 O 70 54 51 51 51 51 51 51 51 51 51 51 51 A 51 51 80 62 48 4fl 49 d8 48 48 48 48 48 49 43 48 48 48 100 77 43 4l 43 43 4l 43 43 43 43 43 43 43 43 43 120 92 40 40 40 40 40 40 40 40 40 40 40 40 40 40 NSSE 5022 Sunrise Boulevard Fair Oats CA 95629(916)536.9585 Rev.I251/2013 Page 7 Series 100 Snap rack- Structural Report and Calculations 31-60 ft.Roof Height Table 1G:Rail Spans(in)for Roof Slopes and Tilt Angles 37'toW6063A11oyWind Load Vult 110 Ifs 120 125 130 135 140 145 150 15580 1909n 17.9 193 212 23.1 249 269 289 31.0 332 35.411 7.8 53.3Pa P� -7.7 -0.4 +9.1 A.9I0.7 -11.6 I2A •141 -1520.6 -190 0 120 [it -A .16 1119 7410 8 110 109 108 10] 106 104 103 101 97 9l9 74 c 20 15 89 89 89 89 89 88 87 86 86 85 84 83 79 74 a 30 23 75 75 75 75 75 75 75 75 75 75 75 74 73 72 y 40 31 66 66 66 66 66 66 66 66 66 66 66 66 66 66 50 39 60 60 60 6D (A 60 60 60 60 60 60 60 v 60 46 55 55 55 55 55 55 55 55 35 55 53WL 70 54 51 11 51 51 51 51 51 51 51 51 51 80 62 48 48 48 48 48 48 48 48 48 48 4B 100 77 43 43 43 43 43 43 43 43 43 43 47 120 92 40 40 40 40 40 40 40 40 40 40 40 31-60 ft.Roof Height Table 3H:RM(ln)for Roof Slopes and Tilt Angles 46'to j66063Aj11oyWind Load Vull Ito 5 130 135 140 145 I50 15580 1909n 17.9 .1 249 26.9 289 31.0 332 35.4 .8 533Pa Pa -T3 S -102 -1L0 •11.9 -12.7 -13.69.6 dl90 0 120 6 113 1 76to 8 104 0 98 97 96 94 93 911 76 v j0 t5 88 8] 86 85 84 83 82 81 81 80 79 77 75 73 0 3 30 23 1 75 1 75 75 75 75 74 73 73 72 72 71 70 68 67 Nq0 3t 66 66 66 66 66 66 66 66 66 65 65 64 63 62 e 50 39 60 60 60 60 6D 60 6D 60 60 60 60 60 59 SB 0 v 6D 46 55 55 55 55 55 55 55 55 55 55 55 55 55 59 70 54 5t 51 51 51 51 51 sl 51 51 51 51 51 SI 51 80 62 48 48 48 48 48 48 48 48 1 48 48 48 48 48 48 too 77 43 43 47 43 43 4J 43 43 1 43 47 43 43 47 47 120 92 40 40 90 40 i0 {0 40 40 4D 40 10 40 40 90 NSSE, 5022 Sunrise Boulevard Fair Oaks CA 95629(916)536.9585 Rev.12/31M13 Page 9 I� I. ( Series 100 Snap race- Structural Report and Calculations 0-30 ft.Roof Height Table 2C:Rail Spans(in)for Roof Slopes and Tilt Angles 37'to 45' 6005Alloy Wind Load Vult 110 115 120 125 130 135 140 145 150 155 160 170 ISO 190 q6 15516.9 ISA 20.0 21.6 233 25.1 26.9 28.8 30.7 3L8 37.0 41.5 462 P4 P. .6.7 -73 .7.9 4.6 43 -10.0 .108 .11.6 -12.4 .13.2 -14.1 ASS -17.8 -19.9 �. 0 0 144 144 144 144 144 141 139 133 121 12 116 109 102 96 ,5 10 B 134 133 132 130 129 128 127 I'3 124 122 116 109 102 96 0 20 15 106 106 106 106 106 106 106 105 105 104 103 101 100 96 > 30 23 90 90 90 90 90 90 90 9D 90 90 90 90 89 88 40 31 79 79 79 79 79 79 79 1 79 79 79 79 79 1 79 79 v 50 19 72 72 72 72 72 72 T 72 72 72 7' 72 72 r- >? 60 -06 66 66 66 66 66Lfil 66 66 66 66 66 66 66 O 62 62 62 62 62 j62 62 62 62 62 62 62 62 70 5480 62 58 58 SB 58 58 58 58 58 58 58 56 58 100 77 52 5E 52 52 52 52 T_ 52 52 52 5E 5E12092 48 48 4848 48 48 48 48 48 48 48 46 0-30 JIL Roof Height Table 2D:Rail Spans(in)for Roof Slopes and Tilt Angles 46'to 60' 6005 Allay Wind Load Vult 110 115 13125 130 135 140 145 150 155 160 170 180 19D qh 155 16.9 .0 21.6 233 25.1 269 288 30.7 32.8 37.0 41.5 462 Pa P� .63 49 1 49 -9.6 -103 -11.0 -11.8 .12.6 -13A -151 -17.0 -18.9 G` 0 0 144 W 14E IJ9 135 132 IN 126 121 113 105 99 s 10 B 123 126 23 121 120 119 116 115 113 112 109 105 99 0 20 IS 106 106 04 103 102 101 100 99 98 97 95 93 91 g30 23 90 9D 0 90 90 9D 89 8B 88 87 85 84 82 40 31 79 79 9 79 79 79 79 79 79 79 78 777 76 50 39 72 72 2 72 72 72 72 72 72 12 72 72 71 e 60 46 66 66 6 66 66 66 66 66 66 66 66 66 66 0 62 62 2 62 62 62 62 62 62 61 62 62 62 70 54BO 62 58 58 6 58 5B 58 58 58 58 58 58 58 58 100 77 52 52 2 S2 52 52 52 52 52 52 52 52 52 120 92 48 48 8 48 4948 48 48 48 48 1 48 48 48 NSSE 5022 sunrise Boulevard Fair Oaks CA 95628(916)536-9585 Rev. 12131/2013 Page 11 Series 100 Snap rack.. Structural Report and Calculations 31-60 ft.Roof Height Table 2G:Rail Spans(in)for Roof Slopes and Tilt Angles 37'to 45' 6005Alloy Wind Load Wit 110 113 1 120 125 130 135 140 145 130 155 160 170 1 190 190 96 179 195 121.2 23.1 24.9 26.9 289 31.0 332 35.4 37.8 426 47.8 533' Pp Ps -7.7 -8.4 s I11.6 -II227A -I13L.3 -I14n.3 0 . 919 10 -i15n2 -I10632 -110831 -2904.6 -2829 9 8 132 I31 129 128 12] 13 124 122 117 112 103 101 94 99 c 20 15 106 IN IN106 106 105 103 t01 IN 102 101 99 94 89 a' 3 30 23 90 90 g0 90 90 90 90 90 90 90 90 69 37 86 h 40 31 79 ]9 74 79 79 79 79 79 79 ]9 79 79 79 79 c 50 39 rz n 72 72 72 72 r_ 7_ 72 1 72 n n 72 rz O 60 96 66 66 66 66 66 66 66 65 66 66 56 66 66 66 70 54 62 62 62 62 62 62 62 62 62 62 62 b2 62 62 80 62 56 58 56 56 58 58 58 58 58 58 58 58 58 58 l09 77 32 52 52 52 52 5_ s2 52 52 52 s r_ sz sz 120 1 92 1 48 1 48 48 46 1 48 48 48 48 48 48 46 48 48 46 31-60 ft.Roof Height Table 211:Rail Spans(in)for Roof Slopes and Tilt Angles 46'to 60' 6005A11oy Wind Load Vult 110 115 120 129 130 135 140 145 I50 I55 160 170 180 190 96 179 195 212 23.1 2A.9 26.9 28.9 31.0 332 35.9 77.8 42.6 47.8 532 P6 P1 -7.3 -U 4L7 AS -102 -11.0 -11.9 -I27 •13.6 .145 .15.5 -175 •19.6 .21.8 L. 0 0 144 149 lil 179 Il6 132 129 IIS 111 104 I 97 91 $ 10 8 125 123 I72 Ix0 118 116 115 I13 111 Il0 103 104 97 91 S20 15 105 104 10J 102 101 100 99 98 97 96 95 92 90 88 30 23 90 90 90 90 90 89 89 1 87 87 86 85 83 82 80 h 40 31 79 79 79 79 79 79 79 1 79 79 79 78 77 76 74 c 50 39 72 72 7272 rz 72 72 72 72 72 72 71 70 a 60 46 66 66 66 66 66 66 66 66 66 66 66 66 65 62 62 62 62 62 62 62 62 62 62 62 62 62 1 80 62 56 58 58 58 38 53 56 58 58 58 58 58 58 58 100 77 52 52 52 52 521 52 52 52 52 T_ 1 52 52 52 52 120 92 98 48 48 49 48 1 48 48 -- 48 q8 48 4B 46 46 1VSSE 5022 Sunrise Roulevatd Fav Oala CA 95628(916)536-9585 Ray. 17012013 Page 13 Series 100 Snap rack- Structural Report and Calculations Summary Charts and Topographic Factors The attached pages of this summary contain some of the most common building configurations with varying wind speeds. These charts serve as quick references for looking up maximum rail spans based on the building and site conditions. However, it must be noted that for any building where a topographic factor is applied (e.g. bills, mesas,seashore),the rail span lengths given might exceed what is allowed for the given site condition. Jr. that case, a registered structural engineer shall evaluate the exact topographic conditions for the specific site. End Zone and Edge Distances The edge zones and/or end zones of the roof area shall be determined based on the building's least horizontal dimension(LDH). The edge zone,"a", is equal to 10%of the LDH where a= .1 * LDH. It should be noted that if the solar panels installed cross two different roof sections,the smaller LDH shall be used. Rail spans in the comer zone shall be a maximum of 24 inches and this restriction will only apply to the rail attachments located in the end and edge zones (does not apply to modulus or rails that overhang into the zone). Furthermore, all edge zones requiring an adjustment (shaded cells in chart) shall be reduced by 24 inches to a minimum of 32 inches. 1�wrxrooar: O Y `� "J G J I G O L LCORNER%ONE 'a Detail 1 roof end/ed a and corner zones NSSE 5022 Sunrise Boulevard Fair Oaks CA 95629(916)536-9585 Rev. 1 213 120 1 3 Page 15 LEGEND AND ABBREVIATIONS TABLE OF CONTENTS SCOPE OF WORK GENERAL NOTES EPAGE DESCRIPTION • SYSTEM SIZE:330OW DC, 3000W AC • ALL WORK SHALL COMPLY WITH 2O13 CEC,2013 CBC, MUNICIPAL CODE,AND SE SERVICE ENTRANCE SOLAR MODULES COVER SHEET • MODULES: (12) REC SOLAR: REC275TP ALL MANUFACTURERS' LISTINGS AND INSTALLATION INSTRUCTIONS. RAIL SITE PLAN INVERTER(S): • PHOTOVOLTAIC SYSTEM WILL COMPLY WITH 2O13 CEC. LAYOUT (1)SOLAREDGE TECHNOLOGIES: SE3000 (240V)W/-ER-US . ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH 2O13 CEC. MP MAIN PANEL OR A-US • PHOTOVOLTAIC SYSTEM IS UNGROUNDED. NO CONDUCTORS ARE SOLIDLY PV4.0 ELECTRICAL • RACKING: SNAPNRACK SERIES 100 UL; FLAT TILE ROOF GROUNDED IN THE INVERTER. SYSTEM COMPLIES WITH 690.35. PV4.1 ELECTRICAL CALCS Or HOOK. SEE PEN D13. • MODULES CONFORM TO AND ARE LISTED UNDER UL 1703. SP SUB-PANEL STANDOFFS& INVERTER CONFORMS TO AND IS LISTED UNDER ILL 1741. FOOTINGS PV-5.0 SIGNAGE • RACKING CONFORMS TO AND IS LISTED UNDER UL 2703. • CONSTRUCTION FOREMAN TO PLACE CONDUIT RUN PER 690.31 O AND 2012 LC PV LOAD CENTER ,�,� CHIMNEY I FC 605.11.2. • ARRAY DC CONDUCTORS ARE SIZED FOR DERATED CURRENT. ATTIC VENT • 9.4 AMPS MODULE SHORT CIRCUIT CURRENT. SM SUNRUN METER 14.68 AMPS DERATED SHORT CIRCUIT CURRENT(690.8(a)&690.8(b)). FLUSH ATTIC VENT ADDITIONAL ELECTRICAL NOTES: pM DEDICATED PV METER • THIS PROJECT SHALL COMPLY WITH THE 2013 CALIFORNIA BUILDING CODE, I PVC PIPE VENT WHICH ADOPTS THE 2012 IBC,2012 UMC. 2012 UPC AND THE 2011 NEC.AND INVERTER(S)WITH City of Menifee WORKING SPACES PER UMC 305 AND NEC 110.26. INV INTEGRATED DC METAL PIPE VENT Building & Safety Dept. • THIS SYSTEM WILL NOT BE INTERCONNECTED UNTIL APPROVAL FROM THE DISCONNECT AND AFCI — T-VENT 0 LOCAL JURISDICTION AND THE UTILITY IS OBTAINED. JUL 01 2016 • THIS SYSTEM IS AN UTILITY INTERACTIVE SYSTEM WITH NO STORAGE AC AC DISCONNECT(S) BATTERIES. O T SATELLITE DISH • THE SOLAR PHOTOVOLTAIC INSTALLATION SHALL NOT OBSTRUCT ANY Received PLUMBING, MECHANICAL, OR BUILDING ROOF VENTS. DC DC DISCONNECT(S) � FIRE SETBACKS � • A LADDER SHALL BE SECURED IN PLACE FOR INSPECTION IN COMPLIANCE EE WITH CAL-OSHA REGULATIONS. • PROPER ACCESS AND WORKING CLEARANCE WILL BE PROVIDED PER COMBINER BOX HARDSCAPE B SECTION 110.26 CEC. -o- • EXPOSED NON-CURRENT CARRYING METAL PARTS OF MODULE FRAMES, PL— PROPERTY LINE EQUIPMENT,AND CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN -I INTERIOR EQUIPMENT — ACCORDANCE WITH 250.134 OR 250.136(A) REGARDLESS OF VOLTAGE.. L J SHOWN AS DASHED SCALE: NTS Sunrum • EACH MODULE SHALL BE GROUNDED USING THE SUPPLIED CONNECTION C POINT IDENTIFIED ON THE MODULE AND THE MANUFACTURER A AMPERE INSTRUCTIONS. AC ALTERNATING CURRENT �:� �`� 00 • IF THE EXISTING GROUNDED ELECTRODE SYSTEM CAN NOT BE VERIFIED AFCI ARC FAULT CIRCUIT INTERRUPTER GILBERT CORREIA.CIO,C46 OR IS ONLY METALLIC WATER PIPING, IT IS THE CONTRACTOR AZIM AZIMUTH CA CL#750184 VICINITY MAP RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE. COMP COMPOSITION 295 TRADE ST.SAN MARCO5.CA 92078 • MODULE INTERCONNECTIONS WILL BE MADE WITH 10 AWG PV RHW/USE-2 DC DIRECT CURRENT PHONE 858.2 1.9079 FAX BSB.550.9506 WIRE. (E) EXISTING ARRAY CONDUCTORS ARE SIZED FOR DERATED CURRENT PER STRING. EXT EXTERIOR CUSTOMER RESIDENCE: • INVERTER PROVIDES NECESSARY GROUND FAULT PROTECTION AS FIRM FRAMING RICK WRIGHT �. REQUIRED BY 2011 NEC 690.5 GROUND FAULT PROTECTION. INT INTERIOR 27958 BLACKHAWK RD, PHOTOVOLTAIC SYSTEM HAS CONDUCTOR BONDED TO GROUND IN LBW LOAD BEARING WALL MENIFEE,CA,92585 27958 BLTckhawk Rd INVERTER AS REQUIRED BY 2011 NEC 690.41 SYSTEM GROUNDING, AND MAG MAGNETIC °[+grya Rd alaCkhawk Rd 690.42 POINT OF SYSTEM GROUNDING CONNECTION. MSP MAIN SERVICE PANEL TEL.(951)238-8962 APN#:33648M d • USE UL APPROVED BONDING FITTINGS AT ALL CONDUIT/BOX JUNCTIONS. n (N) NEW PROJECT NUMBER: Moore Prt7 wng • MODULES CONFORM TO AND ARE LISTED UNDER UL 1703 AND INVERTER NTS NOT TO SCALE CONFORMS TO AND IS LISTED UNDER UL 1741. OC ON CENTER 124R-958WRIG i • THE PV CONNECTION IN THE PANEL BOARD SHALL BE POSITIONED AT THE PRE-FAB PRE-FABRICATED 949.7 5.39 C Tate Rd Tate Rd DESIGNER: OPPOSITE(LOAD)END FROM THE INPUT FEEDER LOCATION OR MAIN PSF POUNDS PER SQUARE FOOT CIRCUIT LOCATION AS REQUIRED BY NEC 690.64(B)(7). PV PHOTOVOLTAIC ELLIOT WENZEL D1s6ounm Prmt Censer TL TRANSFORMERLESS DRAFTER: Vvhitnnpttm Rd . ALL CONDUITS, BOXES, JUNCTION BOXES AND DISCONNECTS SHALL BE TYP TYPICAL R-BIEL PAINTED TO MATCH THE EXISTING BACKGROUND COLOR OF ITS LOCATION. V VOLTS NO VENTS(DORMER, PLUMBING, MECHANICAL)TO BE COVERED OR ROUTED W WATTS SHEET m AROUND SOLAR MODULES. REV NAME DATE COMMENTS COVER SHEET r. g A r REV:A 6/29/2016 PAGE PV-1 .0 ipmwr 1 tr 0 2AI PITCH TRUE MAG PV AREA AZIM AZIM (SOFT) SITE PLAN -SCALE= 1/16"=1'-0" AR-01 22° 232° 220° 124.2 ® PL PL PL AR-02 220 520 40° 88.7 Qy V Qy V OINV e (E) FENCE . . . . (E)RESIDENCE y t , MP (N)ARRAY AR-02 •SM 0 SE sunfun„ O FIRE SETBACKS (3'TYP) GILBERT CORREIA,C10.C46 Q CA CL#750184 (E)DRIVEWAY 29S TRADE ST.SAN OARCOS.CA 92078 F CNE85838tWM Q FAX 858.550.9586 m CUSTOMER RESIDENCE: v P v e RICK WRIGHT v 27958 BLACKHAWK RD, D v \ (N)CONDUIT RUN MENIFEE, CA,92585 D (ON ROOF) TEL.(951)23"962 APN#:336480018 PROJECT NUMBER: PL 124R-958WRIG O �Sy PL DESIGNER: eas.�os.39sa ELLIOT WENZEL O PL DRAFTER: 1 PL R-BIEL PL SHEET (N)ARRAY AR-01 (E)FENCE SITE PLAN REV:A 6/29/2016 PAGE PV-2.0 ROOF TYPE ATTACHMENT ROOF HEIGHT ROOF FRAME FRAME TYPE FRAME MAX FRAME OC ROOF EDGE MAX RAIL MAX RAIL DESIGN CRITERIA EXPOSURE MATERIAL SIZE SPAN SPACING ZONE SPAN OVERHANG MODULES: AR-01 CONCRETE TILE[FLAT] FLAT TILE ROOF HOOK. SEE PEN D13. TWO STORY ATTIC WOOD PREFABRICATED TRUSS 2 X 4 5'-0" 24" 4'-0" 6'-0" 2'-0" ROC SOLAR: REC275TP MODULE DIMS: AR-02 CONCRETE TILE[FLAT] FLAT TILE ROOF HOOK. SEE PEN D13. TWO STORY ATTIC WOOD PREFABRICATED TRUSS 2 X 4 5'-0" 24" 4'-0" 6' -0" 2'-0" 65.5"x 39"x 1.5" MODULE CLAMPS: D1 -AR-01 -SCALE: 3116"=V-0" Portrait: 8.2"- 16.4" PITCH: 22' { 7'-7" 16'-5" 3'— Landscape:4.9"-9.8" AZIM:232° I MAX DISTRIBUTED LOAD: 3 PSF ® 01 (D I SNOW LOAD: 0 PSF 3' WIND SPEED: 110 MPH 3-SEC GUST. LAG SCREWS: 5/16"x3.5":2.5"MIN EMBEDMENT NOTE: 6'TYP 6" INSTALLERS TO VERIFY RAFTER SIZE, SPACING AND SLOPED _E)— I SPANS,AND NOTIFY E.O.R.OF ANY DISCREPANCIES BEFORE ° PROCEEDING. 5'-6„ C5 No. 7 T W sip 70 IO * :t L"111L � s u n ru n D2 -AR-02-SCALE: 3/16"= V-0" PITCH- 22° —3'— 16'-5" 23'-11" GILBERT CORRELk C10,C46 AZIM: 52° CA CL#750184 ® .I ass sPN nwlcos,u,9x1e PHONENE 85 050,28.381.90i9 3 FAX058.550.9566 CUSTOMER RESIDENCE: C� I RICK WRIGHT 27958 BLACKHAWK RD. 5'-6" I-6'TYP-1 � MENIFEE,CA,92585 — TEL.(951)23B-8962 A N#:336480018 PROJECT NUMBER: 124R-958WRIG DESIGNER: 94 9.705.39 53 ELLIOT WENZEL DRAFTER: R-BIEL SHEET LAYOUT r 6/29/2016 PAGE .0PV-3 120/240 VAC SINGLE PHASE SERVICE OMETER#: M SCE 2220„-B,9545 UTILITY GRID EXISTING 200A C 1 MAIN BREAKER (NOT CENTER FED) 1 EXISTING SOLAREDGE 225A TECHNOLOGIES:SE3000 MAIN (N)LOCKABLE (N)SUN RUN (N)LOCKABLE (240V)W/-ER-US OR A-US �� PANEL BLADE TYPE CENTRON 4G BLADE TYPE 3000 WATT INVERTER 2 JUNCTION BOX PV MODULES FACILITY AC DISCONNECT METER AC DISCONNECT OR EQUIVALENT LOADS REC SOLAR: REC275TP /-3 f-3 F3 /-3 _ / (12)MODULES +(�j/� OPTIMIZERS WIRED IN (1)SERIES OF t (12)OPTIMIZERS 20A PV SQUARE D 250V METER SQUARE D LOAD RATED DC SOLAREDGE POWER OPTIMIZER BREAKER AT DU221RB SOCKET DU221RB OPPOSITE END 3R,30A,2P 125A CONTINUOUS 3R, 30A,2P DISCONNECT&AFCI P300 OF BUSBAR 120/240VAC & 120/240VAC 240V METER 200A, FORM 2S CONDUIT SCHEDULE IF THE MAIN SERVICE PANEL HAS THE MAIN BREAKER LOCATED IN THE MIDDLE OF THE BUSS BAR,THEN THE MAXIMUM COMBINED OVERCURRENT DEVICES ALLOWED IS 100 PERCENT OF # CONDUIT CONDUCTOR NEUTRAL GROUND THE BUSS BAR RATING. s u n ru n 1 NONE (2) 10 AWG PV WIRE NONE (1)6 AWG BARE COPPER DO NOT INSTALL INVERTER WHERE IT COULD BE EXPOSED TO DIRECT SUNLIGHT _ 2 3/4" EMT OR EQUIV. (2) 10 AWG THHN/fHWN-2 NONE (1)8 AWG THHN/THWN-2 O 3 3/4" EMT OR EQUIV. (2)10 AWG THHN/THWN-2 (1) 10 AWG THHN/THWN-2 (1)8 AWG THHN/THWN-2 PROVIDE INVERTER SHADING REQUIREMENTS GILBERT CORREIA,G10,C46 INSTALLER TO PROVIDE A NEW 3/4"DIAMETER X 10'-0" LONG GROUND ROD WITH MINIMUM CA CL#750184 8'0" EMBEDMENT IF EXISTING BUILDING ELECTRODE SYSTEM IS NOT ACCESSIBLE. 295 TRADE ST.SAN MARGOS,CA 82878 FAX N .S L95688i9 FAX 058.558.9566 MODULE CHARACTERISTICS CUSTOMER RESIDENCE: OPTIMIZER CHARACTERISTICS G12AWGBARE SS SPLIT COPPER WIRE SS SPLIT LOCK WASHER RICK WRIGHT REC SOLAR: REC275TP 275 W MIN INPUT VOLTAGE 8 VDC tSSBONDING (TORQUE TO16FT-LBS) 27958 BLACKHAWK RD, / CK MENIFEE, CA,92585 OPEN CIRCUIT VOLTAGE 38.8 V MAX INPUT VOLTAGE 48 VDC GROSNA N D LUGROUNDLUG TEL.(951)23&8962 APN#:336480018 MAX POWER VOLTAGE 31.4 V MAX INPUT ISC 10 ADCl / BONDINGPROJECT NUMBER: SHORT CIRCUIT CURRENT 9.4 A MAX OUTPUT CURRENT 15 ADC \ CHANNELNUT 124R-958WRIG SYSTEM CHARACTERISTICS-INVERTER 1DESIGNER: 949.705.3953 RAIL ELLIOT WENZEL PINS SYSTEM SIZE 3300 W NOTE: . ALL HARDWARE IS INCLUDED FROM MANUFACTURER DRAFTER: SYSTEM OPEN CIRCUIT VOLTAGE 12V . A MINIMUM OF ONE GROUND LUG IS TO BE INSTALLED ON EVERY R-BIEL CONTINUOUS ROW OF MODULES SYSTEM OPERATING VOLTAGE 350 V . GROUNDING LUG MAY BE INSTALLED IN EITHER RAIL CHANNEL MAX ALLOWABLE DC VOLTAGE 500 V . GROUNDING LUG MAY BE INSTALLED SO GROUND WIRE IS PARALLEL SHEET OR PERPENDICULAR TO RAIL ELECTRICAL ENSURE SPLIT LOCK WASHER IS INSTALLED ON TOP OF COPPER WIRE SYSTEM OPERATING CURRENT 9.4 A SNAPNRACK GROUNDING SCALE:NTS REV:A 6/29/2016 SYSTEM SHORT CIRCUIT CURRENT 15 A PER CODE:690.52 PAGE PV-4.0 System Information 3.3 kW DC Photovoltaic System (12)REC Solar: REC275TP,SolarEdge Technologies:SE3000(240V)w/-ER-US or A-US Allowable Backfeed Allowable Back-feed= (Main Panel Rating)x 1.2-(Main Breaker Rating)_ 225A x 1.2- 200A=70A 20A<_70A 4 Interconnection meets 705.12(D)(2) requirements. DC Wire Sizing Max Circuit Current=(Optimizer Max Power)x(Continuous Load)(690011)(1)]_ 1SA x 1.25= 18.75A Adjusted Conductor Ampacity=(High Temp)ITable 310.161 x(Conduit Fill)]Table 310.15(6)(2)(a)] x(Conductor Ampacity)(Table 310.16' _ 0.76 x 1 x 40A=30.4A Terminal Ratingl110.14(q] = 10 AWG,60°C Rated= 30A 30A< 30.4A 4 Terminal rating governs conductor sizing. 18.75A<30A-> lO AWG Ampacity OK Therefore 10 AWG is sufficient. AC Wire Sizing Max AC Output Current= (Max Inverter Output)x(Continuous Load)1210.19(A)(1)] 12.5 A x 1.25= 15.63 A Adjusted Conductor Ampacity= (HighTemp)]Tabie 310.161 x(Conduit Fill)ITabie 310.15(e)(2)(01 x(Conductor Ampaeity)]Tab1e 310.16'_ s u n ru 1 x 1 x 40A=40A / ® - Terminal Ratingl110.14iq] 10 AWG,60'C Rated= 30A GILBERT CORREIA.C70,C46 30A<40A--) Terminal rating governs conductor sizing. CA CL#750184 15,63A<30A 4 10 AWG Ampacity OK n5 TRADE ST.souMOROOS.0 92078 PHONE e58.281.9079 Therefore 10 AWG is sufficient. FM 85B 550.9566 CUSTOMER RESIDENCE: Inverter Overcurrent Protection RICK WRIGHT (Inverter Max Current)x(Continuous Load)= 27958 BLACKHAWK RD, MENIFEE, CA,92585 12.5 A x 1.25=15.63 A 4 20 A Overcurrent Protection TEL(951)23841962 APN k.336480018 System Characteristics PROJECT NUMBER: VMa =Inverter Fixed String Voltage= 124R-958WRIG 350V I DESIGNER: 949.705.3953 Voc = Max Inverter System Voltage = ELLIOT WENZEL 500V I DRAFTER: Operating Current =(DC System Size)/350V= R-BIEL 330OW/350V =9.43 A SHEET Short Circuit Current= (Optimizer Max Current)x(#Strings) ELECTRICAL CALCS 15Ax1= 15A REV:A 6/29/2016 PAGE PV-4.1 A WARNING ' oil ELECTRIC SHOCK HAZARD THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED LABEL LOCATION: AC DISCONNECT,POINT OF INTERCONNECTION LABEL LOCATION: (PER CODE:CEC690.54) DC DISCONNECT,INVERTER (PER CODE:CEC 690.35(F)) WARNING [To be used when inverter is ungrounded) INVERTER OUTPUT CONNECTION • NOT A WARNING RELOCATE LABEL LOCATION: ELECTRIC SHOCK HAZARD POINT OF INTERCONNECTION DO NOT TOUCH TERMINALS (PER CODE:CEC 705.12(D)(7)) TERMINALS ON BOTH LINE AND [Not required if panelboard is rated not less than sum of ampere ratings LOAD SIDES MAY BE ENERGIZED of all overcurrenl devices supplying it) IN THE OPEN POSITION DC VOLTAGE IS ALWAYS PRESENT CAUTION : SOLAR CIRCUIT WHEN SOLAR MODULES ARE EXPOSED TO SUNLIGHT LABEL LOCATION: LABEL LOCATION: MARKINGS PLACED ON ALL INTERIOR AND EXTERIOR DC CONDUIT,RACEWAYS,ENCLOSURES, AC DISCONNECT,POINT OF INTERCONNECTION AND CABLE ASSEMBLIES AT LEAST EVERY 10 FT,AT TURNS AND ABOVEIBELOW PENETRATIONS (PER CODE:CEC 690.17(E)) AND ALL COMBINERMUCTION BOXES. (PER CODE:IFC605.11.1A) A WARNING SOLAR • ELECTRIC SHOCK HAZARD LABEL LOCATION: ■ DO NOT TOUCH TERMINALS DISCONNECT,POINT OF INTERCONNECTION TERMINALS ON BOTH LINE AND (PER CODE:CEC690.13(e)) - LOAD SIDES MAY BE ENERGIZED CAUTION A WARNING DUAL POWER SOURCE ■ IN THE OPEN POSITION LABEL LOCATION: SECOND SOURCE IS PHOTOVOLTAIC SYSTEM POWER TO THIS BUILDING IS AC DISCONNECT,POINT OF INTERCONNECTION n PER CODE:CEC 690.17(E),CB LABEL LOCATION: 1� run POI O INTERCONNECTIONWARNING-Electric Shock Hazard ALSO SUPPLIED FROM THE -- (PERR CODE:DE:CEC 705.12(D)(4)) CAUTION: SOLAR ELECTRIC 1'0 � No user serviceable parts inside 1W senrice provider for assistanceSYSTEM CONNECTED FOLLOWING SOURCES WITH GILBERT CORREIA.C10,G6 CA CL#750184 LABEL LOCATION:authorized LABEL LOCATION: DISCONNECTS AS SHOWN INVERTER,JUNCTION BOXES(ROOF),AC DISCONNECT WEATHER RESISTANT MATERIAL,DURABLE ADHESIVE, 295 TRI,pE BT.eAN MAftG0.S.CA 920T8 (PER CODE:CEC690.13.G.3&CEC 690.13.G.4) UL969 AS STANDARD TO WEATHER RATING(UL LISTING PHONE 858281.9W9 OF MARKINGS NOT REQUIRED),MIN%'LETTER HEIGHT FAa 85e.550,9566 WARNING: • • • ARIAL OR SIMILAR FONT NON-BOLD,PLACED WITHIN 11 POWER SOURCE THE MAIN SERVICE DISCONNECT,PLACED ON THE SOLAR PANELS CUSTOMER RESIDENCE: OUTSIDE OF THE COVER WHEN DISCONNECT IS A, ON ROOF RICK WRIGHT LABEL LOCATION: OPERABLE WITH SERVICE PANEL CLOSED. CONDUIT,COMBINER BOX (PER CODE:CEC690.15,690.13(B)) 27958 BLACKHAWK RD, (PER CODE:CEC690.31(G)(3)(4)&CEC 690.13(G)(4) MENIFEE, CA, 92585 INVERTER i TEL.(951)238-8962 APN#:33648D01B RATED MAXIMUM POWER- 9 4 PROJECT NUMBER: POINT CURRENT (Imp) 124R-958WRIG RATED MAXIMUM POWER- POINT VOLTAGE (Vmp) 350 DESIGNER: 949,705.3953 MAXIMUM SYSTEM sooVOLTAGE (VOC) SERVICE ENTRANCE ELLIOT WENZEL MAXIMUM CIRCUIT CURRENT (Isc) is INVERTER LOCATIOlr= A4 AND PV BREAKER DRAFTER: AC DISCONNEDISCONNECT R-BIEL LABEL LOCATION: SHEET (DC PER CODE:CEC INVERTER SUNRUN ME DISCONNECT SIGNAGE (PER CODE:CEC690.53) ADHESIVE FASTENED SIGNS: •THE LABEL SHALL BE SUITABLE FOR THE ENVIRONMENT WHERE IT IS INSTALLED. REV:A 612912 116 •WHERE REQUIRED ELSEWHERE IN THIS CODE,ALL FIELD APPLIED LABELS,WARNINGS,AND 27958 BLACKHAWK RD, MENIFEE, CA, 92585 MARKINGS SHOULD COMPLY WITH ANSI Z535.4[NEC 110.21(8)FIELD MARKING]. •ADHESIVE FASTENED SIGNS MAY BE ACCEPTABLE IF PROPERLY ADHERED.VINYL SIGNS SHALL PAGE PV-5.0 BE WEATHER RESISTANT(IFC 605.11.1.31