Loading...
PMT16-02077 City of Menifee Permit No.: PMT16-02077 29714 HAUN RD. 4AQ LXk' MENIFEE,CA 92586 Type: Residential Addition MENIFEE Date Issued: 0 710 112 01 6 PERMIT Site Address: 29408 CHERYL WAY, MENIFEE, CA Parcel Number: 341-190-040 92587 Construction Cost: $350.00 Existing Use: 1 &2 Family Residence Proposed Use: Description of AS-BUILT 2-PILASTERS PER CITY STANDARD Work: Owner Contractor ANGELANAYA 29408 CHERYL WAY MENIFEE, CA 92587 Applicant License Number: ANGELANAYA 29408 CHERYL WAY MENIFEE, CA 92587 Phone: 9518379270 Fee Description Qtv Amount lSl Building Permit Issuance 1 27.00 Wall/Fence,standard 1 83.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 1.00 General Plan Maintenance Fee-Building 1 4.15 $116.15 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance.or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Pennit_Template.rpt Page 1 of 1 CITY OF MENIFEE LICENSED DECLARATION property who builds or improves thereon,and who contracts for the projects I hereby affirm under penalty of perjurythat I am under provisions of with a licensed contractor(s)pursuant to the Contractors State License law). Chapter9(commencing with section 7000)of Division 3 of the Business and ❑I am exempt from licensure under the Contractors State License Law for Professions Code and my license is in full force and effect. the following reason: License Class License No. By my signature below I acknowledge that,except for my personal residence Expires Signature in which I must have resided for at least one year prior to completion of WORKER'S COMPENSATION DECLARATION improvements covered by this permit.I cannot legally sell a structure that I have built as an owner-builder if it has not been constructed in its entirety by o 1 hereby affirm under penalty of perjury one of the following declarations:I licensed contractors.I understand that a copy of the applicable law,Section have and will maintain a certificate of consent of self-insure for workers 7044 of the Business and Professions Code,is available upon request when compensation,issued by the Director of Industrial Relations as provided for this application is submitted or at the following website: by Section 3700 of the Labor Code,for the performance of work for which this permit is Issued. www.IeKinfo.m.Rov/caIaw.htmI. Policy# Date ❑I have and will maintain workers compensation insurance,as required by PROPERTY OWNER OR AUTHORIZED AGENT section 3700 of the Labor Code,for the performance of the work for which D By my signature below I certify to each of the following:1 am the property this permit is issued.My workers compensation insurance carrier and policy owner or authorized to act on the property owners behalf.I have read this number are: application and the information I have provided is correct.I agree to comply Carrier with all applicable city and county ordinances and state laws relating to building construction.I authorize representatives of this city or county to Polity 9 Expires enter the above identified property for inspection purposes. (This section need not to be completed is the permit is for one-hundred Date dollars($100)or less OPERTYO NER OR AUTHORIZED AGENT o I certify that In the performance of the work for which this permit is issued, I shall not employ any persons in any manner so as to become subject to the CITY BUSINESS LICENSE# workers compensation laws of California,and agree that If I should become HAZARDOUS MATERIAL DECLARATION subject to the workers compensation provisions of Section 3700 of the Labor Code,I shall forthwith comply with those provisions. Will the applicant or future building occupant handle hazardous material or a Applicant mixture containing a hazardous material equal to or greater that the PP Date amounts specified on the Hazardous Materials Information Guide? WARNING:FAILURE TO SECURE WORKER'S COMPENSATION COVERAGE IS D Yes ❑No UNLAWFUL,AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES Will the intended use of the building by the applicant or future building AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS($100,000),IN occupant require a permit for the construction or modification from South ADDITION TO THE COST OF COMPENSATION,DAMAGES AS PROVIDED FOR Coast Air Quality Management District(SCAOMD?See permitting checklist IN SECTION 3706 OF THE LABOR CODE,INTEREST,AND ATTORNEYS FEES for guidelines CONSTRUCTION LENDING AGENCY o Yes o No I hereby affirm that under the penalty of perjury there is a construction Will the proposed building or modified facility be within 1000 feet of the lending agency for the performance of the work which this permit is issued outer boundary of a school? (Section 3097 Civil Code) o Yes o No OWNER BUILDER DECLARATIONS 1 have read the Hazardous Material Information Guide and the SCAOMD I hereby affirm under penalty of perjury that 1 am exempt from the permitting checklist.I understand my requirements under the State of Contractors License Law for the reason(s)indicated below by the California Health&Safety Code,Section 25505 and 25534 concerning checkmark(s)I have placed next to the applicable item(s)(Section 7031.5 hazardous material reporting. Business and Professions Code).Any city or county that requires a permit to oYes allo construct,after,improve,demolish or repair any structure,prior to its Date issuance,also requires the applicant for the permit to file a signed statement PROPERTY OWNER OR AUTHORIZED AGENT that he or she is licensed pursuant to the provisions of the Contractors State EPA RENOVATION,REPAIR AND PAINTING fRRP) License Law(Chapter 9(commencing with Section 7000)of Division 3 of the The EPA Renovation,Repair and Painting(RRP)Rule requires contractors Business and Professions Code)or that he or she is exempt from licensure receiving compensation for most work that disturbs paint in apre-1978 and the basis for the alleged exemption.Any violation of Section 7031.5 by residence cor ompensation enfor moy to st eork thartifiedrspairms nicomplywith than Applicant for a permit subjects the applcant to a civil penalty of not more required practices.This includes rental property owners and property than($500). managers who do the paint-disturbing work themselves or through their ❑I,as owner of the property,or my employee with wages as their sole employees.For more information about EPA's Renovation Program visit: compensation,will do( )all of or( )portion of the work,and the structure is www.epa.gov/lead or contact the National Lead Information Center at not intended or offered for sale.(Section 7044,Business and Professions 1-800424-LEAD(5323). Code;The Contractors State License Law does not apply to an owner of a o An EPA Lead-Safe Certified Renovator will he responsible for this project property who,through employees'or personal effort,builds or Improves the property provided that the improvements are not intended or offered for Certified Firm Name: sale.If,however,the building or improvement is sold within one year of Firm Certification No: completion,the Owner-Builder will have the burden of proving that it was not built or improved for the purpose of sale. o No EPA Lead-Safe Certified Firm is required for this project because: o I,as owner of the property am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractors State License Law does not apply to an owner of a If your project does not comply with EPA RRP rule please fill out the RRP Acknowledgement. & SAFETY PERM IT/PLAN CHECK APPLICATION l Menifee DATE - �, PERMIT/PLAN CHECK NUMBER O1,Oh 1 TYPE: O COMMERCIAL * RESIDENTIAL O MULTI-FAMILY O MOBILE HOME O POOL/SPA O SIGN SUBTYPE: O ADDITION O ALTERATION O DEMOLITION O ELECTRICAL O MECHANICAL O NEW O PLUMBING /0 RE-ROOF-NUMBEnR OF SQUARES DESCRIPTION OF WORK . �S7`'• + PROJECTADDRESS jqqOjQ Va I v4cm; ec 75'0- ASSESSOR'S PARCEL NUMBER LOT TRACT _ -- OWNER NAME 411W r)6 -p ADDRESS % ¢ c Y✓ICn� teL ��' q2sgf PHONE EMAIL i APPLICANT NAME ,I Avva,4,L ADDRESS Vt. e z PHONE ( 57 137 21 c) EMAIL - CONTRACTOR'S NAME 'e OWNER BUILDER? *YES C NO BUSINESS NAME 1r p ADDRESS PHONE LCt51) �3� Cl 110 EMAIL CONTRACTOR'S STATE LIC NUMBER - LICENSE CLASSIFICATION VALUATION$ SO FT ( X Z L SO FT APPLICANT'S SIGNATURE DATE CITY STAFF USE ONLY DEPARTMENT DISTRIBUTION �'J CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN I SMIP INVOICE PAID AMOUNT AMOUNT • O CASH O CHECK# Q CREDIT CARD VISA/MC PLAN CHECK FEES PAID AMOUNTCASH O CHECK# OCREDITCARD VISA/MC OWNER BUILDER VERIFIED OYES O NO DL NUMBER NOTARIZED LETTER O YES O NO City of Menifee Building& Safety Department 29714 HDun Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.Lis Inspection Request Line 951-245-6213 ROUSE CITY OF MENIFEE BUILDING AND SAFETY DEPARTMENT PLAN APPROVAL REVIEWED BY 1.� NO VW - TE 'Approval of these plans shall not be construed tobeapemdtfo oran approval of,any violation of any provisions of the federal, r city regulations and ordinances. This set of approved plans mu e kept onthe jobsite until completion. p;1,-� P1 �s'kr (01 %Z4 V �ao�rr pR.ot W71 L109 r r AljAYA 9Sj 7 9z /'z o h"' TOP VIEW FOOTING I I City of Menefee --_l,= BLOCKBuilding & Safety Dept. I 27" :•:.:•:•:••• GROUT JUL 0 1 20 ----- STEEL REBAR Receive BAR I PLACEMENT --1 I�- 27„ ILLUSTRATION I I SECTION VIEW I I BLOCK (12"X 12"OR 16"X 16") I I I SOLID GROUT MIN.24" 6' (4)-#4REBAR REBAR MAX ii (ONEAT EACH CORNER) OVERLAP = ALL FOOTINGS ADJACENT TO SLOPES TO BE AT LEAST 5'TO -_ DAYLIGHT AS SHOWN BELOW. ------- MIN 24" REBAR , OVERLAP - _ s(O O GRADE •'•'•'• qP BOTFOM , 5'MIN- FOOTING LIMITATIONS: FoonNGREswR sxuE I.PILASTER SPACING SHALL NOT EXCEED 20 FT.WHEN OTHER INFILL FENCING FWVEA MPI.E•'IANG 2D" xoOXwrmwwrt IS ATTACHED. t6„ v ONCRETECOVEROF '" 2 ONLY OPEN TYPE FENCING(SUCH AS WROUGHT IRON)MAY BE ATTACHEDTO PILASTERS. SOUDTYPEFENCINGMAYNQI BEATTACHEDTO PILASTER. 1 3.GATES AND DOORS ATTACHED TO PILASTER ARE LIMITED TO 200#MAX. WEIGHT AND FT.MAX.WIDTH PER PILASTER. JU 4.THI5 PILASTER DESIGN IS INTENDED TO BE USED ONLY AS A FENCING �27' FEATURE AND IS NOT INTENDED TO SUPPORT ANY OTHER LOADS. S.FFEEG`N1C�,IE HEIGHTS ARE REGULATED—CONSULT ZONING REGULATIONS BEFORE CHECKTO VERIFY IF A BUILDING PE Mrr S DEPARTMENTNG UI ED. CI6'.I�15p7UAI ggl�jggll T I�Appyyr�EALeE,p RRIICy�CIIRpCp7UIITIS.CONDUUIpTe�S.O—R_LI-GHTING FIXTURES WHEN INGINSIE IONS R REQUIRED, BII�i)��Ur,. prUT7 ` j EY I7F TLI�AFNTERLY COMPACTED THOTING;EXCAV TIONT RENCH LEAN REQUIRED: �YT�17NNCIYT6V�e KJ.CEO�N UNC 91'[1!!6 STN,6R�PI20F 1)FOOTING;EXCAVATION TRENCH CLEAN WITH STEEL IN PLACE AND SUPPORTED 3"ABOVE AND AWAY FROM RS,SEE FREESTANDI CK WALL STANDARD. THE SURROUNDING THE EARTH/DIRT. WESTERN RIVER d I UNTY CO UNIF4111MITY PROGRAM 2)REBAR/PRE-GROUT; VERTICAL REBAR IN PLACE- I- /I INSPECTION PRIOR TO PLACING GROUT. E y k ' 1(u. 3)FINAL;AFTER GROUT IS PLACED-PRIOR TO ANY DECORATIVE CAP PLACEMENT. NI DISCLAIMER: MA SO PILASTER ALTERNATE DESIGNS MAY BE POSSIBLE WHEN PROVIDED WITH A r ns sh it not be construed to bea 1iiamftfororan AN ENGINEERED ANALYSIS. USE OF THIS STANDARD DESIGN IS r�li�Nl +db�FPon of any• rt�®rsnelaflttle6ede AT THE USER'S RISK AND CARRIES NO IMPLIED OR INFERRED pp , P Mh,Stftff*t CA 92586 GUARANTEE AGAINST FAILURE OR DEFECTS. e90ltl4fW4' 3Ws• R dAP Ov 8 IDS thl PAGE f OF 1 to sl a uniii completion.