Loading...
PMT16-02060 City of Menifee Permit No.: PMT16-02060 29714 HAUN RD. SACCELh� MENIFEE, CA 92586 Type: Residential Electrical MENIFEE Date Issued: 0711112016 PERMIT Site Address: 27910 RADFORD DR, MENIFEE, CA Parcel Number: 335-091-018 92586 Construction Cost: $26,525.00 Existing Use: Proposed Use: Description of INSTALL ROOF MOUNTED SOLAR SYSTEM,34 PANELS, 1 INVERTER,7.812 kW Work: Owner Contractor TIM PAGE NEW DAY SOLAR 27910 RADFORD DRIVE 23811 WASHINGTON AVE STE C110 MENIFEE, CA 92586 #224 Applicant Phone:8554446329 TIM STONEKING License Number:812958 NEW DAY SOLAR 23811 WASHINGTON AVE STE C110 #224 MURRIETA, CA 92562 Fee Description Qtv Amount ISI Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 Additional Plan Review Electrical 158 157.50 GREEN FEE 1 2.00 SMIP RESIDENTIAL 1 4.00 General Plan Maintenance Fee-Electrical 1 12.60 $466.10 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carded on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise slated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bidg_Permit_Template.rpt Page 1 of 1 CITY OF MENIFEE LICENSED DECLARATION property who builds or improves thereon,and who contracts for the projects I hereby affirm under penalty of perjury that I am under provisions of with a licensed contractor(s)pursuant to the Contractors State License Law). Chapter9(commencing with section 7000)of Division 3 of the Business and a am exempt from licensure under the Contractors State License Law for Professions Code and my license is in full force and effect, the following reason: License Class C mil] License No. By my signature below I acknowledge that,except for my personal residence Expires_Signature in which I must have resided for at least one year prior to completion of improvements covered by this permit.I cannot legally sell a structure that I WORKER'S COMPENSATION DECLARATION have built as an owner-builder if it has not been constructed in its entirety by o l hereby affirm under penalty of perjury one of the following declarations:I licensed contractors.I understand that a copy of the applicable law,Section have and will maintain a certificate of consent of self-insure for workers 7044 of the Business and Professions Code,is available upon request when compensation,issued by the Director of Industrial Relations as provided for this application is submitted or at the following website: by Section 3700 ofthe Labor Code,for the performance of work for which www.le¢info.ca.aov/calaw.html. this permit Is issued. Policy JI Date PROPERTY OWNER OR AUTHORIZED AGENT o 1 have and will maintain workers compensation insurance,as required by section 3700 of the Labor Code,for the performance of the work forwhich 0 By mysignature below I certify to each of the following:I am the property this permit is issued.My workers compensation insurance carrier and policy owner or authorized to act on the property owners behalf.I have read this number areC:'� (� ` application and the information I have provided is correct.I agree to comply Carrier JV`Ec-'�—t; r 2a� t4 with all applicable city and county ordinances and state laws relating to [� .1 ' building construction.I authorize representatives of this city or county to Poliryq /Zk�C/ Expires Q enter the above identified property for inspection purposes. (This section need not to be completed Is the permit is for one-hundred Date dollars($100)or less PROPERTY OWNER OR AUTHORIZED AGENT 0 I certify that in the performance of the work for which this permit is issued, I shall not employ any persons in any manner so as to become subject to the CITY BUSINESS LICENSE g workers compensation laws of California,and agree that if I should become HAZARDOUS MATERIAL DECLARATION subject to the worker's compensation provisions of Section 3700 of the Labor Code,I shall forthwith complyw��ttkIhose pro ifons. Will the applicant or future building occupant handle hazardous material ora / y� mixture containing a hazardous material equal to or greater that the Applicantr�� ./ ¢Date amounts specified on the Hazardous Materials Information Guide? WARNING:FAILURE TO SECURE WORKER'S COMPENSATION COVERAGE 15 0Yes {dNo UNLAWFUL,AND SHALL SUBJECT AN EMPLOYER TO CRIMINAL PENALTIES Will the intended use of the building by the applicant or future building AND CIVIL FINES UP TO ONE HUNDRED THOUSAND DOLLARS($100,000),IN occupant require a permit for the construction or modification from South ADDITION TO THE COST OF COMPENSATION,DAMAGES AS PROVIDED FOR Coast Air Quality Management District(SCAQMD)?See permitting checklist IN SECTION 3706 OF THE LABOR CODE,INTEREST,AND ATTORNEYS FEES for guidelines CONSTRUCTION LENDING AGENCY ❑Yes_-No I hereby affirm that under the penalty of perjury there is a construction WIII the proposed building or modified facility be within 1000 feet of the lending agency for the performance of the work which this permit is issued outer bounda. of school? (Section 3097 Civil Code) 0 Yes OWNER BUILDER DECLARATIONS I have read the Hazardous Material Information Guide and the SCAQMD permitting checklist.I understand my requirements under the State of I hereby affirm under penalty of perjury that I am exempt from the California Health&Safety Code,Section 25505 and 25534 concerning Contractors License Law for the reason(s)Indicated below by the hazardous material reporting. checkmark(s)I have placed next to the applicable item(s)(Section 7031.5 oyes /! Business and Professions Code).Any city or county that requires a permit to construct,alter,improve,demolish or repair any structure,prior to its PROPERTY OWNER CiJR­AUTH[_0RIZED9k6CNT issuance,also requires the applicant for the permit to file a signed statement that he or she is licensed pursuant to the provisions of the Contractors State EPA RENOVATION.REPAIR AND PAINTING(RRPJ License Law(Chapter 9(commencing with Section 7000)of Division 3 of the The EPA Renovation,Repair and Painting(RRP)Rule requires contractors Business and Professions Code)or that he or she is exempt from licensure receiving compensation for most work that disturbs paint in a pre-1978 and the basis for the alleged exemption.Any violation of Section 7031.5 by residence or childcare facility to be RRP-certified firms and comply with an Applicant for a permit subjects the applicant to a civil penalty of not more required practices.This includes rental property owners and property than($500). managers who do the paint-disturbing work themselves or through their ❑I,as owner of the property,or my employee with wages as their sole employees.For more information about EPA's Renovation Program visit: compensation,will do( )all of or( )portion of the work,and the structure is www.eoa.eov/lead or contact the National Lead Information Center at not intended or offered for sale.(Section 7044,Business and Professions 1-800-424-LEAD(5323). Code;The Contractors State License Law does not apply to an owner of a 0 An EPA Lead-Safe Certified Renovator will be responsible for this project property who,through employees'or personal effort,builds or improves the property provided that the improvements are not Intended or offered for Certified Firm Name: sale.If,however,the building or improvement is sold within one year of Firm Certification No.: completion,the Owner-Builder will have the burden of proving that it was not built or Improved for the purpose of sale. 0 No EPA Lead-Safe Certified Firm is required for this project because: o I,as owner of the property am exclusively contracting with licensed contractors to construct the project(Section 7044,Business and Professions Code:The Contractors State License Law does not apply to an owner of a If your project does not comply with EPA RRP rule please fill out the RRP Acknowledgement. EsGil Corporation In(Partnership with Government for Building Safety DATE: 07/06/16 p APPLICANT ti—JURIS. JURISDICTION: City of Menifee ❑ PLAN REVIEWER ❑ FILE PLAN CHECK NO.: PMT16-02060 SET: I PROJECT ADDRESS: 27910 Radford Dr. PROJECT NAME: TIM PAGE 7,700 Watts Solar Photovoltaic System. ® The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. ❑ The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. ❑ The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. ❑ The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. ❑ The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. ❑ The applicant's copy of the check list has been sent to: ® Esgil Corporation staff did not advise the applicant that the plan check has been completed. ❑ Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted' Telephone #: Date contacted: ( ) Fax #: Mail Telephone Fax In Person E-mail: ❑ REMARKS: By: Sergio Azuela Enclosures: EsGil Corporation ❑ GA ❑ EJ ❑ PC 07/01 9320 Chesapeake Drive,Suite 208 ♦ San Diego, California 92123 ♦ (858)560-1468 ♦ Fax(858)560-1576 City of Menifee PMT16-02060 07/06/16 [DO NOT PAY- THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: City of Menifee PLAN CHECK NO.: PMT16-02060 PREPARED BY: Sergio Azuela DATE: 07/06/16 BUILDING ADDRESS: 27910 Radford Dr. BUILDING OCCUPANCY: TYPE OF CONSTRUCTION: BUILDING AREA Valuation Reg. VALUE ($) PORTION ( Sq. Ft.) Multiplier Mod. Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code mnf Manual Input Bldg. Permit Fee by Ordinance Plan Check Fee by Ordinance Type of Review: ❑ Complete Review ❑ Structural Only ❑Repetitive Fee El Other Repeats ] 1.5 Hrs. @ EsGil Fee $157.50 ' Based on hourly rate Comments: 1 1/2 hours plan review. Sheet 1 of 1 macvalue.doc+ ISEINNOVATIVE STRUCTURAL ENGINEERING, INC. INNOVATIVE z997o TECHNOLOGY DR,SUITE io8 STRUCTURAL MURRIETA,CA 92563 ENGINEERING PHONE:95i.600.0032 www.ISEengineers.com STRUCTURAL CALCULATIONS FOR: PAGE RESIDENCE PHOTOVOLTAIC ARRAY ADDITION 27910 RADFORD DR SUN CITY CA z 86 City of MenlfeDe t. 9 5 Building & Safety P JUN 3 0 2016 O Received 9 OWNER/DEVELOPER New Day Solar 23811 Washington Ave. Suite iio #224 Murrieta, CA 92532 June 27, 2oi6 9 ISE PROJECT z t S 6 m Exp.6/30/18 �� MUSGS Design Maps Summary Report User-Specified Input Report Title Page Residence Tue June 28,2016 00:26:47 UTC Building Code Reference Document ASCE 7-10 Standard (which utilizes USGS hazard data available in 2008) Site Coordinates 33.71580N, 117.209710W Site Soil Classification Site Class D - "Stiff Soil" Risk Category I/II/III Nuevo, i,Nq[t _1gi[.l4 J2 SI -- Perry,.:.. �o,ir ;l .Rulnolmld _Horneland Hem 7-1 SA im City Nhnch stet 1� .Lake Ekinore USGS-Provided Output Ss = 1.500 g S,s = 1.500 g S" = 1.000 g S, = 0.600 g S,,, = 0.900 g S0, = 0.600 g For Information on how the SS and S1 values above have been calculated from probabilistic (risk-targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the"2009 NEHRP"building code reference document. MCEa Response Spectrum Design Response Spectrum 1.65 1.50 1.10 1.35 0.95 1.20 0.99 1.05 0.77 P 0.90 Oi 0.66 N 0.75 on 0.55 0.GO 0.44 0.45 0.33 0.30 0.22 0.15 0'11 0.00 0.00 0.00 0.20 0.40 0.60 0.90 1.00 1.20 1.40 1.60 1.20 2.00 0.00 0.20 0.40 0.60 0.20 1.00 1.20 1.40 1.G0 1.20 2.00 Period,T(sec) Period,T(sec) For PGA„, T„ Cis, and Ca,values, please view the detailed report. ° In INNOVATIVE STRUCTURAL ENGINEERING, INC. INNOVATIVE z997o TECHNOLOGY DR,SUITE io8 STRUCTURAL MURRIETA,CA9z563 ENGINEERING PHONE:95i.600.0032 www.ISEen ineers.com CBC SECTIONS 3403.3 &3403.4 - ADDITIONS Check Photovoltaic Array Addition at Buildings -2013 California Building Code Gravity Design Loads: Roof Type: Shingle over i/z"Plywood sheathing over 2x4 Rafters over 5/8"gypsum board with insulation and miscellaneous loading Roof Live Load: F 200 psf Root Dead Load: Roofing Material: 12.0 psf Sheathing: 1.5 psf Roof Framing Members: 1.5 psf Drywall: 3.0 psf Insulation: 1.0 psf Miscellaneous: 1.0 psf Solar Array&Rack System 2.80 psf Roof Dead Load w/o Solar Array= 1 20.00 jP5f Roof Dead Load at Solar Array= 1 22.80 psf Total Roof Load w/o Solar Array= 1 40.0 jPsf Total Roof Load at Solar Array= 1 42.8 psf Area of Solar Array Addition(for gravity check)= fflft, Total Area of Affected Roof(for gravity check)= fe Area of Solar Array Addition(for lateral check)Total Area of Affected Roof+Floor(lateralcheck) ft`(Floor IfApplicable) - ISEINNOVATIVE STRUCTURAL ENGINEERING, INC. INNOVATIVE 2997oTECHNOLOGY DR,SUITE 3o8 STRUCTURAL MURRIETA,CA92563 ENGINEERING PHONE:951.600.0032 www.ISEen ineers.com CBC SECTIONS 3403.3 &3403.4 - ADDITIONS Check Photovoltaic Array Addition at Buildings- 2013 California Building Code Check Additional Gravity Load: Total Load Increase at Affected Roof= 0.90 psf Percentage of Total Load Increase= 2.24% < 5.o% OK Per CBC 3403.3 Additional Solar Array Weight is Structurally Acceptable Check Additional Gravity Load on Lateral Resisting System: (Floor Load at 2-Story only if Applicable) Dead Load Increase at Entire Roof+Floor= 0.90 psf Prct.Dead Load Increase on Entire Roof+Floor= 4.48% < io.o% OK :. Per CBC 3403.4 Additional Solar Array Lateral Load is Structurally Acceptable INNOVATIVE STRUCTURAL ENGINEERING,INC. IN NBVATIVE 2997o TECHNOLOGY DR,SUITE io8 STRUCTURAL MURRIETA,CA 92563 ENGINEERING PHONE:95i.600.0032 www.ISEen ineers.com ROOF MOUNTED SOLAR PANELS - Earthquake Analysis Earthquake Design per ASCE 7-10- Section 13.6 (Mechanical/Electrical Components) Array Properties(Per Solar Array Designer) Warray:1 2.80 PSF AREAarray: 602.0 1FT' Seismic Anchor Properties(Anchor Per Solar Array Designer) Vallow(NDS Table 11.2A): 23o lb/Mt 5/16"Lag Screw w/minimum 2.5"Embedment using Tallow(NDS Table 11K): 1o64 lb/ SnapNRack Mount System FDesign Parameters Site Class= D ASCE 7.10,Sec.11.4.2 1 Latitude,deg Longitude,deg Ss= 1.500 USGS 33.7158 -117.2097 S1= o.600 USGS Site Coefficient,Fa= 1.00 Table 11.4-1 Site Coefficient,Fv= 1.5o Table 11.4-2 S0s=2/3 Fa*Ss= 1.000 ASCE 7-io,EQ 11.4-3 So,=2/3 Fv*S1= o.600 ASCE 7-lo, EQ 11.4-4 Importance Factor,le= 1.00 ASCE 7-io,Table 1.5-2 Height of Equipment,z= 16.00 ft Height of Roof, h= 27.00 ft ap= 1.00 Table 13.6-1 RP= 1.50 Table 13.6-1 Determine Fp,Seismic Design Force(STRENGTH LEVEL)-ASCE 7-lo Section 13.3.1 Fp=(o•4aPS0slp)(1+2z/h)/(R)IP)= 0.769 EQ 13.3-1 Fp max=i.6S0sl,= 2.600 [Not Greater Than] EQ 13.3-2 Fp min=o.3S0slp= 0.3o0 [Not Less Than] EQ 13.3-3 CBC/IBC Alternate Load Combinations(A5D)-5ection 16o5.3.2, EQ.16-20&16-21 Sf=FP/1-4= o.549 j Horizontal Seismic Force ASCE 7-lo, EQ 12.4-3 Sfv=0.2S0s/1.4 = 0.143 lVertical Seismic Force ASCE 7-lo, EQ 12.4-4 Number of Required Seismic Anchors(Tension&Shear) Vseismic=Sf*Warray*AREAarray= 925 lb,Total Lateral Load on Seismic Anchors Tseismic=Sfv*Warray*AREAarray= 241 lb,Total Vertical Load on Seismic Anchors No.of Anchors=Vseismic/Vallow= 4.0 No.of Required Lateral Load Seismic Anchors No.of Anchors=Tseismic/Tallow= 0.2 No.of Required Vertical Load Seismic Anchors Total No.of Required Anchors= 2 Worst Case Tension or Shear No.of Anchors Supplied by Designer= 34 RoofTrac Standoff Mounts w/5/16"Lag Screw IS[ INNOVATIVE STRUCTURAL ENGINEERING, INC. INN UVATIVE 2997o TECHNOLOGY DR,SUITE 1o8 STRUCTURAL MURRIETA,CA 92563 ENGINEERING PHONE:951.600.0032 www.ISEen ineers.com ROOF MOUNTED SOLAR PANES - Wind Analysis Components and Cladding -Wind Load Design per ASCE 7-3.0, 30.4.2 - h<6o ft Array Properties(Per Solar Array Designer) Warray: 2.8o PSF AREAarray: 602.0 IFT2 Seismic Anchor Properties(Anchor Per Solar Array Designer) Vallow(NDS Table z 2A):j 230 lb/Mt 5116"Lag Screw wl minimum 2.5"Embedment using Tallow(NDS Table zlK): io64 lb/Mt I Rooftrac Mount System Design Parameters Design Wind Velocity(3s Gust),V= 110 mph Wind Exposure= C Mean Panel Height= 26.00 ft Total Effective Area of Typical Array= 602 ft' Panel Area to Each Support= 12 ft' Angle of Panels= 23 degrees "a"= 3.5 ft(3ft.Min.) Determine Wind Force at Each Roof Mount qh=0.00256K�KrtKdV"= 13.4 psf Load caseo.6*W K�= 0.85 Table 30.3-1,Page 317 Kn= z.o Figure 26.8-1, Page 252-253 Kd= 0.85 Table 26.6-3., Page 250 I= 1.00 GCP(Zone i)-r o.3o -0.80 Per Figures 30.4-1 thru 30.4-7 GCP(Zone 2)=1 0.30 1 -1.20 Per Figures 30.4-1thru 30.4-7 GCP(Zone 3)= 0.30 1 -2.00 (NO PANELS IN ZONE 3 FOR THIS PROJECT) (+)P=qh(GCP-GCP;)= io.o -i6.i psf,Positive Wind(io psf min)-Worst Case Lateral Load at Each Mount= 47 76 Ibs Compression l Uplift at Each Mount= zio i78 Ibs Rooftrac Roof Mount is attached to aligned roof member w/(i)5/16"Lag Screw w/Min,2.5"thread Embedment per Solar Designer Roof Mount Specification. Analysis Summary: Since allow. attachment design loads are greater than Wind demad,design is structurally acceptable. SUNNY BOY 300OTL-US / 3800TL-US /400G6 s. v-.. 5000TL-US / 6000T'L-US a 00OTL-US 770�: ' J / / THE WORLD'S ONLY SECURE POWER SUPPLY CON us Intertek Certified Innovative Powerful Flexible •UL 1741 and 1699B compliant •Secure Power Supply provides -97.6%maximum efficiency -Two MPP trackers provide •Integrated AFCI meets the require- daytime power during grid outages •Wide input voltage range numerous design options meets of NEC 2011 690.11 •Shade management with OplTrac - Extended operating Global Peak MPP tracking temperature range SUNNY BOY 3000TL-US / 380OTL-US /4000TL-US / 5000TL--US / 6000TL--US / 7000TL-US / 770OTL-US Setting new heights in residential inverter performance The Sunny Boy 3000TL-US/3800TL-US/4000TL-US/5000TL-US/6000TL-US/7000TL-US/7700TL-US represents the next step in performance for UL certified inverters.Its transformedess design means high efficiency and reduced weight.Maximum power production is derived from wide input voltage and operating temperature ranges. Multiple MPP trackers and OptiTracrm Global Peak mitigate the effect of shade and allow for installation at challenging sites.The unique Secure Power �?9E IN INFafl Supply feature provides daytime power in the event of a grid outage. High performance, flexible design and innovative features make the Sunny Boy TL-US series the first choice among solar professionals. 0 a 'Ha IMPaa4� ....... Elfidency curve SUNNY BOY 5000TL-U&22 2AOVoc! Accessories 00 ............. ................. .........06 ... ............. .......... WDMUS.jo............ 94 9? B�fv,- V11 ,="I�coon,3,=2 3800/ 90 ve FANMTD2 10 Be t fy.-lwvl E,.[V�- SO V) ..... 475 on 0.2 0.4 0.6 0.8 10 a Standard feature 0 Optional feature Not vvoilable Output.F.... Rated�, ...... ... Data.1 nvminvl cond8ivns Sunny Bay SOO(rrL-US Sunny Roy 6000TIL-US Sunny Boy 7000TL-US Sunny Bay 7700TIL.US 208 V AC 240 V AC 208 V AC 240 V AC 208 V AC 240 V AC 208 V AC 240 V AC 530OW 6300 W 7300 W 8000 w 600 V 600 v 600V 600 V 175- 480V 210-480V 245-480 V 270-480V 125-500V 125-500V 125-500 V 125-SOO V 125 V/150 V 125 V/150 V 125 V/150 V 125 V/150 V 30A/15A 30A/15 A 30A/18A 30A/18A 2/2 4550 W 5000 W 5200 W 6000 W 6000 W 7000 W 6650 W 7680 W 4550 VA 5000 VA 5200 VA 6000 VA 6000 VA 7000 VA 6650 VA 7680 VA 208 V/o 240 V/* 208 V/e 240 V/* 208 V/e 240 V/0 208 V/* 240 V/o 183-229 V 211 -264 V 183 -229V 211 -264V 183-229 V 211 -264V 183-229 V 211 -264 V 60 Hz 59,3-60 5 H2 60 H. 59.3-60.5 Hz 60 Hz 59.3-60.5 Hz 60 Hz 59.3-60.5 Hz 22A 25A 29.2 A 32A I I 1 1 1/2 1/2 1/2 1/2 4-. <A% <A% <4% 97.2% 97.6. 97.0. 97.4% 96.8% 96.8% 96.8% 97.3% 96.5', 97.0% 96.5-- 97.07. 96.5% 96,5% 96.5% 96.5'- • • • • • I/iv 490/519/185 (19.3 20.5/7.3) 187/297/190 17.4111.717.5) 617/597 266 124.3 23,5 10.51 370/240 2 80 (14.6 9.4 11.0) 24 kg 15316)/3.5 kg (S Ila) 27 kg (6016)/3.5 kg 18 lb) -40-C...+60°C (-40'F.,.+140*F) <29 dB(Al <29 dBIA) <29 dB(A) <29 dB(A) ,I W <I W <I W <TW Trandanninle. Tmrof.rrmulm Tmnsfamerlm Tmnsf.,nerle,s Convection Fan Fan Fan NEMA 3R NEMA 3R NEMA 3R NEMA3R 010 010 0/0 0/0 0/0/0 6/0/0 0/0/0 0/0/0 UL 1741,UL 1998,UL 1699B,IEEE]547,FCC Part 15(Clws A&31,CAN/CSA C22.2,107.1-1 SI3 500OTL-US-22 SB 6000T,-US-22 SB 7000TL-US-22 SB 7700TL.US.22 C"►J I(YOCERa KU -60 1000U Series KU265-6MCA CUTTING EDGE TECHNOLOGY - — - - - -- —As a pioneer with four decades of experience in the MENEM development of photovoltaic systems, Kyocera drives the market a leading provider of PV products- MEMEMI demonstrate ate our Kaizen philosophy, or commitment to continuous improvement, by setting the industry standard in the innovation of best-in-class solar energy equipment. MENNEN QUALITY BUILT IN MEMMEM • UV-stabilized, anodized aluminum frame in black •Supported by major mounting structure manufacturers MIEMMEM • Easily accessible grounding points on all four corners for fast installation • Proven junction box technology with 12 AWG PV wire MMMIMEM works with transformerless inverters •Amphenol H4-UTX locking plug-in connectors MMMMEM provide safe, quick connections PROVEN RELIABILITY MISEMEM • Kyocera modules confirmed by the Desert Knowledge Australia Solar Centre to have the highest average MEMIMEM output of any crystalline module • First module manufacturer in the world to pass long- term sequential testing performed Th Rheinland ■■■_ ■®® •Only module manufacturerto achievv e the e rank of "Performance Leader" in all six categories of GTM Research's 2014 PV Module Reliability Scorecard CERTIFICATIONS • UL1703 Certified and Registered, UL Module Fire Performance:Type 2, CEC • NEC 2008 Compliant, IEC 61215/61730,and ISO 14001 C UL US - E HIGH EFFICIENCY MULTICRYSTAL PHOTOVOLTAIC • • SOLARbyKYOCERA VINCI & ASSOCIATES Structural Engineers CLIENT: Professional Solar Products, Inc. 1551 S. Rose Ave., Oxnard, CA 93033 Tel:805-486-4700 Subject: Static load test results for the following: Mounting System Min Rail Height Max Span(in.) Maximum Frame Maximum Frame Load Equivalent Wind Speed (n.) Length*(in.) Width*(in.) (Ibs/ft') 1 (mph)** Rooffrac0 2-1/2 72 1 65(77**) 40 50 1 125(100**) TEST SETUP(as shown in attached drawing detail):Three modules,as specified above, were bolted to 2.5"tallProfessional Solar Products(PSP)patented Roof rracc support rails using an assembly of 5/16"Stainless Steel (SS)bolts, SS lock washers and proprietary PSP aluminum clamps and inserts.The RoofTrac®support rail was attached to the PSP RoofTracs structural attachment device with 3/8"SS hardware at four attachment points.The setup was attached to 2"x6" wooden rafters using 5/16"x 34/2"SS lag bolts.The attachment spans consisted of 48"front to rear with structural attachments spaced 72"on center. TEST PROCEDURE(as shown in attached drawing detail):The test set up was top loaded to above specified load.The setup remained loaded for an approximate period of 30 minutes.The maximum deflection and any signs of permanent deformation were recorded.The test setup was then inverted and loaded to simulate the uplift condition.The test set up was re-loaded to above specified load.The setup remained loaded for an approximate period of 30 minutes.The maximum deflection and any signs of permanent deformation were recorded. TEST RESULTS: The maximum top load deflection was recorded at 0.313",with no permanent deformation. The maximum uplift deflection was recorded at 0.250",with no permanent deformation. This document certifies the Roofirac®mounting system used with the modules,as specified above,withstands the stated static pressure load, equivalent to the stated wind speeds**. The mounting system performed as expected. Sincerely, James R.Vinci,S.E. This engineering report verifies that Vinci&Associates has provided independent observation for load testing as described in this report. The results of this load test reflect actual deflection values and are generally accepted as the industry standard for testing module mounting systems. Vinci&Associates does not field check installations or verify that the mounting system is installed as described in this engineering report. Structural attachment: Lag bolt attachment should be installed using the proper pilot hole for optimum strength.A 5/16"lag bolt requires a 3/16"pilot hole. It is the responsibility of the installer to insure a proper attachment is made to the structural member of the roof. Failure to securely attach to the roof structure may result in damage to equipment,personal injury or property damage. The purposed racking system may be installed on any roof up to a maximum of 24 foot above grade without further analysis. Racking can be installed at any location on the roof. Racking shall be installed into a roof member or blocking with a 5/16"diameter screw at each Fast-jack location. Screws shall have minimum of 2 Yz penetration into framing member for zone 1&2,and a minimum of 3"penetration into framing member for zone 3. (Zone 3 is defined as the approximately 4'-0"square at each comer of the roof) This office does not express an opinion as to the load bearing characteristics of the structure the mounting system/modules are being installed on. ICC accredited laboratory tested structural attachments manufactured by Professional Solar Products (including,but not limited to Fast lack®,TileTrac®,and FoamJack®)can be interchanged Win this system. & o Check with local building department or AHJ for she specific requirements. t -Z *Modules measuring within stated specifications and tested to UL1703,or equivalent,are Included w Ex in this engneering **Wind loading values relative to defined load values using wind load exposure(125 mph for 5/12 TUap� a�P roof pitch or less;100 mph for greater than 5/12 roof pitch)and gust factor coefficient"exposure C" qTP CAUFpC� as denied in the 2012(IBC)/2013(CBC).For 77"x 40"module,equivalent wind speed derated to 100 mph. ***Module tested:64.6"x 39.4"x 1.7"(sin) ****Est.snow load rating.of 25 Ib/ftz based on 2.0 safety factor.(15 Itvftz for 77"x 40"module) 175 E. Wilbur Rd, Suite 103 Thousand Oaks, CA 91360 Page f of 2 RT_6 Off FastJack r ' Patent R6,360,491 ' ' � � t r Fastjack° Structural Roof Attachment ith New Aluminum Flashing and Collar "See 90 second > real-time complete : install video at MUM.prosolar.com" y , a• Available in: Ytall FastJack"E-Series Part#FJE-200 T tall FastJack�E-Series Part#FJE-300 Fast."talck E-SeriFastJacke laSeries Part#FJE-050 FastJacka E-Series Flashing&Collar Part#FJE-Flash AlF Benefits ofFastjacknand Fastjack Flashing • Lowest cost, highest quality • Black powder-coated flashing and collar • 90 second install time • Solid aluminum post prevent water flow • Includes Stainless Steel (SS) lag through post into roof bolt and SS ProSolar rail attachment • Heavy-duty 0.032" aluminum flashing hardware thickness • • ' • The Fastjack Design • • • Patented, single lag bolt design makes it the easiest to install attachment • • • • 2 piece design allows flashing to easily slip over base, prior to post : 1 : . 11 • Flashing design prevents water ingress from any direction . r • Made in U.S.A., American Recovery and Reinvestment Act (ARRA) • " ' • compliant professional G§o)usSOLAR im ProSolar® RoofTrac® prods Inrertek Bonding and Grounding Guide .ton„ UL2703 (Patent Pending) I For RoofTraca Rail Bonding Splice •Drill 1/2"holes at bottom of rails with 1/2"110 Irwin I, Unibit"using the rail support as a hole location guide. No buss bar • Insert 5116"bolt through support holes and hand thread into thread splice rail support insert. Fasten to 15 ft-Ibs. I I For bonding module frame and clamps to support rail Green lock washer indicates Fasten pre-assembled mid-clamp assembly to module electrical band frame,to 15 fit-Ibs. Module Frame Design: I double wall,aluminum, 12" 2.0"tall,0.059"-0250" thickness, UL1703 or equivalent tested module. UL467 standard tested bonding equipment for use with Professional Solar Products(PmSolarr)support rail. Bonding of module to RoofTra&rail via ProSolaO rail channel nut using buss bar. Bonding of RoofTrac"rail to RoofTraO rail via ProSolar' UL467 tested universal splice kit(splice insert and splice support). Assembled Self-bonding Self-bonding Mid Mid Clamp With SS Bus Bar Clamp Fastened on Rail Grounding of RoofTrac"rail via Ilsco SGB-4 rail lug. (Solar Module not shown) System to be grounded per National Electrical Code(NEC). See NEC and/or Authority Having Jurisdiction (AHJ)for grounding requirements prior to installation. See final run(racking to ground electrode)grounding equipment installation instructions for specific installation information. COPYRIGHT PROFESSIONAL SOLAR PRODUCTS 2015:All information contained in this manual is property of Professional Solar Products(PSP). TleTrac'is a registered trademark for PSP and Is covered under U.S.patent#5,746,029.Roofrra&and FastJacV are registered trademarks for PSP and are covered under U.S.patent#6,360,491.Roof rrac'bonding designs patent pending. Page 1 of 4 EmListing Constructional Data Report (CDR) 1.0 Reference and Address Report Number 100779407wc-003 Original Issued: 14-Se -2012 Revised: 28-A r-2015 Standard(s) L Subject 2703-Outline of Investigation Rack Mounting Systems and Clamping Devices for Vat-Plate Photovoltaic Modules and Panels. Issue#2: 2012/11/13 Applicant Professional Solar Products, Inc. Manufacturer Professional Solar Products, Inc. Address 1551 S. Rose Avenue Address 1551 S. Rose Avenue Oxnard, CA 93033 Oxnard, CA 93033 Country USA Country USA Contact Stan Ullman Contact . Stan Ullman Phone (805)486-4700 Phone (805)486-4700 F (805)486-4799 EA FAX mail sC@orosolar.com Email s@prosolar.com Page 1 of 63 This report is for the exclusive use of Intertek's Client and is provided pursuant b the agreement between Intertek and its Client. Intedek's responsibility and liability are limited to the terns and conditions of me agreement. Intertek assumes no liability to any party, other than to the Client in accordance vnm the agreement,for any loss,expense or damage occasioned by the use of this report Only the Client is authorized to permit wpying or distribution of this report and then only in its entirety.Any use of me Intertek name or one of its marks for the sale or advertisement of the tested material,product or service must first be approved in venting by Intertek.The observations and test results in this report are relevant only to the sample tested.This report by itself does not imply that the material,product,or service is or has ever been under an Intertek wrsfication program. Page 3 of 4 CAUTION -DUAL POWER SUPPLY- POWER TO THIS BUILDING IS ALSO SUPPLIED FROM THE FOLLOWING SOURCES WITH DISCONNECTS LOCATED AS SHOWN ® Driveway i. Q O ® a Inverter Utility Point Service Me erin - Photovoltaic System Specifications - Rated Maximum Power-point Current (DC): 34.2 Amps Rated Maximum Power-point Voltage (DC): 341.0 Volt Maximum System Voltage (DC): 471.86 Volt Short Circuit Current (DC): 11.57 Amps Rated output Current (AC): 32.0 Amps Nominal Operating Voltage (AC): 240.0 Volts '(New Day Solar 1 (855) 444-6329 SERVICE BY QUALIFIED PERSONNEL ONLY TOTAL SYSTEM SPECIFICATIONS NOTES: One Line Wiring Diagram for Photovoltaic System Roof Type:Comp-Model'.Weih265SMCA 1. All UL,withsuppliedClass FinsR Rating eUL,ETL grouped th the proposed racking, r r { Length:65.431nches Width:38.981nches Weight:41.91bs. UL,with a ClassA Fire Rating when grouped with the proposed raddng,while 34 Kyocera KU265-6MCA Solar Modules PTC 238.1 Total module weight: t 1b lbsx54=97.2 lbs. Inverters carry a1741UL Listing Attachment weight:1.8 Ibs x 54=97.2 lbs. 2. All equipment will be installed and grounded in accordance with current code - Rail weight.7.351b.x 23=169.1 Ibs, and manufacture's installation instructions. _ and 1 SMA SB770OTL-US (240Vac) Inverter Total am fight a:38..98 x 65431144=( 7.71)Ibs.= 602.19 sqt 3. Note"warning: stow shall ai plastic,Sourc graved or machine printed letters. The Total anay area:38.98 x 65.43/144=(17.71)x 34=602.19 sq ft "Warning:Photovoltaic Power Source"sign will be at least 3/8 inch-high white Maximum roof load:2.8Ibs.per square foot, lettering on red background.The sign vAll be applied with approved adhesive Maximum attachment load: 31.31 Ibs.per altadlment material. System Size: 7.812 kWAC *4. All conduit shall be as follows: `1 New Day Solar rn PVC for below ground wiring,Metalic Flex for indoor attic locations,and EMT v ELECTRICAL CALCULATIONS FOR CONDUCTORS(SOLAR) Article 240.41)CEC Article 110.14 CEC 310.15((B 2))((a))CEC for above ground.Conduit runs shall be located as to reduce trip hazard,as 310.15(B)(16)CEC 310.15(B)(16)CEC 310.15(B��3)(C)CEC minimized in length as possible and installed along bottom of load bearing CIRCUITLOCATiON AMPS MAXA WIREGAUGEBTYPE SMM CAPACITY 1111RECAPACITY CONDUITTYPE #ofCONOUCMRs CONDUITSQE members. Module1J-Box C1 9.26 1.56 0 40Am m 90c° A .64 ° 1NA 25.6kn NA 5. Photovoltaic DC conductors entering the building shall be installed ina C Q Module/J-Box C2 9.26 1.56 14.44 #10 Pv-wde 40Ampsm gOc NA .64 MA 25.6Am s NA 2 1 NA metallic raceway and shall be ideni fed every 10 feet,within 1 foot of turns or > C Module I J-Box C3 926 1.56 14. #to PV_Wre 40Am 90e° NA .64 90c NA 25.6Am NA NA bends and within 1 foot above or below penetrations of roof tiling assemblies, O ModulelJ-Box C4 9.26 1.55 14.44 #10 Pv-wte 4OAm 90e NA .649W)INA 25.6Amps NA BAm s 6walls or barriers with'WARNING:PHOTOVOLTAIC POWER SOURCE."will be L J43oxllnvelter C5 9.26 1S6 14.44 #10 THHNRHV&2 40Am g0if NA .64 90c° INA 25. 2 NA installed.(CRCR331.2) I7( (V V . Photovoltaic equipment and all associated wiring and inleroonnedons shall be M C: L J-Boxllmeiter 9.26 1.56 14.44 #10 THHNffHM2 40Am s a W1 NA .64 gW INA 25.6Am 2 _ 3WorLarya' installed by Qualified Personal as well as Current(2013)California Building Ja milmarter C7 925 1.56 14.44 #10 THHWUHM2 40Am s i 90c° NA 64 9W INA ps NalAim#4 2 -8 Code(CBC),California Electrical Code(CEC),California Residential Electrical 0 0 �_ J- alinverter 9. U-44 111 41Ampsm( NA .64 11 INA 25.6Am NDMM#4 Code (CRC), California Plumbing Code (CPC),Green Building Code, �/'� 0)N N InvederlSelvice C9 32 125 40 THHNRMAI4-2 55Am 90e° 5OAm m 50°iixonu 1.0 90e° 11.0 55/50Am *Notafdn#4 3 3'wa and Current Mechanical Code. �/J � N 0) N y) J Seldo:!Outlet CIO 30 NA 30 Fd Tf#iWfHNN-2 55Am 90c° WAm 5e em�.l 1.0 90t .0 5c° 5y50 prn s *Noletion#4 Wor 7. Utility will be notified and grant permission before full activation of the PV CO system. Q M B. Backfed breaker used as the method of the interconnection shall not read, � Q ` , "Line and Load". T V 1 11 9. Photovoltaic system conductors shall be identified and grouped. The Q ` LJ�J CIO means of identification shall be permitted by separate color coding, S marking tape,tagging,or other approved means. The means of grouping 4_1 shall be We lies or similar means at least once,and then at intervals not to exceed six feet. T_ � ---- City Of Menifeo co L Ln Z Building R Safety De .Z M 5 (E)200Amp Service Panel JUN3U2016 Nero w/a 200Amp Main Breaker R I eceiver, 0/�0 o W t C10 L c Ir- , , , 3sAmp L Q LC} OI C1 J-Box uaa u _ 0 N , _ 1 L 0). °. - - - - - - - 0 2 L 5 U 1 - - SMA America ^ LL. co 3 6 SB770OTL-US-22 C9 L. , 30A F+ (240Vac) CV cn R I 7s � L 1 _ � � � E � � � � Groundingis Integrated 1 N r^ m "See note below. 8 ° ��^" L.L r vJ PRE-EXISTING GROUNDING ELECTRODE Drawn B New Da tGroundin is#6 Grounding is#8THHWTHWN-2 nubeas4^Bmansasmpwe,mrsmY y. y lar Bare Copper Date: AA lk ixa w cawaaor„e, ,nry m mxan a auPPieawntd gmun�ig ek_nraae. AHJ Ap o Module to racking grounding will be achieved via integrated Pro Solar Green Self-Bonding The Main Breaker is located at the end of the Bussing. Prepared B � :S�-��tl -" Clips and Splices. Each row of modules will then be connected via IISCO SGB-4 lug or similar PV Connection to the Service Panel is positioned at the p y and#6 bare copper to junction box.Grounding from junction box to equipment/service will be opposite end of the buss from the main Circuit I on. �O R. Scott Carlson, CA State License#812958,Type C10&C46 #8(or greater)THHN/THWN-2(LIL 467)(CEC 250.136A). Per.CEC 705.12(D) Scale: 1" = 20' , New Day Solar J 0- a) E w Q O L 0 O 'CT LO M p)NN0) O 151' UM) 0 CD N Utilit Point Service Meterin m -0 � CO CO LO 161' z : � LO z N (n � 00 36" Fire Pa ay 00 < < • A 36" ire Pathway M CO L C) Lo O� O � N O < O' 52 0 LO p • ® N� 4-M CO -a 6" e Fiat ay (n 0- O U �Z O 0 6" Fire Path ay > 0) � Driveway N U) 0) Q AHJ Approval Area 95' + Conduit Run will be nearly all through attic locations. Rain-tight metallic flex will be used, as well / � as EMT for entry into attic locations for roof-mounted installations. Compliant with 690.4(F) Prepared By:,- + Roof Access points shall be provided in accordance to v2013 CRC R331.4.1 and CBC 3111.4.1 R. Scott Carlson + Modules shall not exceed ridge, and lay parallel to roof surface for all roof-mounted installations. + Disconnects shall be clearly marked and shall conform with NEC article 690. CA State License# 812958 + CRC2013 (California Residential Code) Smoke alarms and Carbon Monoxide detectors shall/ License Type C46 are located as required per Sections R314 and R315 within CRC2013. Scale: 1° = 20' 12" minimum distance from all heating ventilation. Key No roof vents will be covered by modules. ; • Penetration Standoff LL Racking Rails New Day Solar Rafter Size: 2" x 4" Spacing: 24" o.c. L Q o W CO c N L O ° � M 151' C�Q0) N U, CO U ili Point Service Meterin U) o U co C Q 0Inydrter ce 161 Q� 000 •� � LO LO Z N U) 00 36' Fire Pa ay 00 ,�•� • 36" ire Pathway �. � N0 M OLO U o 52 � 0 V ' I LO I i CO re at ay ( N "gyp 6" Fire Path a V J a T U r. Z Driveway ,�•f r , E_ In 5' AHJ Approval Area + Conduit Run will be nearly all through attic locations. Rain-tight metallic flex will be used, as well as EMT for entry into attic locations for roof-mounted installations. Compliant with 690.4(F) Prepared By: + Roof Access points shall be provided in accordance to v2013 CRC R331.4.1 and CBC 3111.4.1 R. Scott Carlson + Modules shall not exceed ridge, and lay parallel to roof surface for all roof-mounted installations. CA State License#812958 + Disconnects shall be clearly marked and shall conform with NEC article 690. + CRC2013 (California Residential Code) Smoke alarms and Carbon Monoxide detectors shall/ License Type C46 are located as required per Sections R314 and R315 within CRC2013. Flashable Roof Stanchion Breakdown Module Placement Dimensions 40 rr�nn 3/8"x 3/4" V SS Hex Bolt" Q 3/8" SS rNew Day Solar Flat Washer Q O � rrnn O The post is installed through 65�� 48�� cc Q N U Z Flashings slip over base and the top of the flashing. Cfl L under the delicate shingle O 0 d' U-) cc — �N0) CN O �— N Overhang ll not 0 U wi be more than 20" s72" � U � d� � Q� co i L R5/16" x 3-1/2" Racking Specifications and Notes Z 00 �° _ SS Lag Bolt Threaded Fast Jack 1) RoofTrac shall be used for all racking, fitted with N U) Base, Standard or Fast Jack attachments for all anchorage. Min. E-Series 2) The Roof Track railing mounting system design is rated for (D 00 Embedment Embe Into Roof Rafter woe '� withstanding a 50 lbs. per square foot static pressure load, CO L. i equivalent to a wind speed of approximately 125 mph. Q 0 (`f w y� m 3) Utilizing the Fast Jack series, the vertical ultimate load is 2,359 lbs. 4— -a 0 0 � M' s5 while the lateral ultimate load is recorded at 808 lbs. E 3d. O I Module Racking Height s sTRUCTORP� Q 4) Modules shall not exceed ridge. 4— r'TFOFCAI.UF-tea 5) All roof penetrations are sealed with sealant and are �a) a ")� d' SOLAR PANEL guaranteed for ten years. 0) >,qt CY) FAST JACK *See attached cutsheets for supporting documentation. M += N U 0 TOTAL SYSTEM SPECIFICATIONS LLii N r/� Q Roof Type: Comp Model: KU265-6MCA AHJ Approval Area SHINGLES Length: 65.43 Inches Width: 38.98 Inches Weight: 41.9 lbs. 2 x Rafter Modules will installed Total module weight: 41 lbs. x 34= 1,424.6 lbs. parallel to rooff surface Attachment weight: 1.8 lbs x 54 = 97.2 lbs. and shall not exceed ridge. Rail weight: 7.351b. x 23 = 169.1 lbs. Total weight: 1,424.6 lbs. + 97.2 lbs. + 169.1 lbs. = 1,690.85 lbs. Prepared By Total array area: 38.98 x 65.43/144 = (17.71) x 34 = 602.19 sq ft. R. Scott Carlson Maximum roof load: 2.8 lbs. per square foot. CA State License # 812958 Maximum attachment load: 31.31 lbs. per attachment. License Type C46 A.GENERAL . 1. Applicable codes. Photovoltaic equipment,all associated wiring and interconnections shall be installed by WARNING Qualified Personal. All projects shall comply with the following referenced codes: CAUTION a. 2013 California Electrical Code(CEC) CONDUCTORS ARE ALWAYS ENERGIZED, _ � •� b. 2013 Califomia Building Code(CBC)and/or 2013 Residential Code(CRC) EVEN WHEN MAIN IS DICONNECTED -DUAL POWER SUPPLY- c. 2013 California Plumbing Code(CBC) d. 2013 California Mechanical Code(CMC) THERE IS UP TO 600 VOLTS DC. POWER TO THIS BUILDING IS ALSO SUPPLIED e. 2013 California Fire Code SERVICE BY QUALIFIED PERSONS ONLY. FROM THE FOLLOWING SOURCES WITH - New Da Solar W B.ROOF DISCONNECTS LOCATED AS SHOWN f. Current California Business and Professions Code Contact: New Day Solar 1 (855)444-6329 y 1. Roofing and weatherproofing. All roofing and weatherproofing installation shall comply with the following methods Mounting Location:Junction Box s and requirements: 9 O ® 'A J a. Any arrays integrated with the roofing material shall be Class"A"rated. Applicable only if system includes a string inverter(s). b. All roof penetrations shall be secure and weather-tight.(CRC 903.2) E c. Module installations shall not cover or block any roof plumbing or mechanical vent locations. (CPC 904, --- CPC 906,CMC 802.6,CMC 510.8) d O W 2. Firefighter access requirements. All roof-mounted solar photovoltaic systems shall comply with the following: PV SYSTEM DISCONNECT Drive (� (� r`nf a. Roof access points shall be provided per the following and in conformance with CRC -9 �V N L R331.4.1 or CEC3111.4.1 as applicable: FOR UTILITY OPERATION m 1. Located in areas not requiring placement of ground ladders over openings such as doorsAMndows. -WARNING- POOI O O N'IT � N 2. Located at strong points of building construction in locations where access point does not conflict - ELECTRICAL SHOCK HAZARD - U) 0)N N N Z with overhead obstructions such as tree limbs,wires,or signs. F.I. 2. Inspector access requirements. Aportable ladder complying with CAL-OSHA requirements shall be made available TERMINALS ON BOTH LINES AND ` .— * and secured in place for inspection. LOAD SIDES MAY BE ENERGIZED M (D c U � v C.ELECTRICAL 1. wring methods. All wiring installation shall comply with the following methods and requirements: L".- N OPEN POSITION. DUAL POWER Q r �/� a. All supplied electrical equipment is UL,ETL or CSA listed.Modules are 1703 UL,with a Class A Fire Rating r `°r� when grouped with the proposed racking,while Inverters carry a 1741 UL Listing. SUPPLY PHOTOVOLTAIC SYSTEM (d 4 b. All equipment will be installed and grounded in accordance with current code and manufacture's installation _— _— U +- d' instructions. Mounting Location:Disconnecting means(NEC 690.17) \C r O c. All junction boxes,disconnects and conductors are in accordance withlables 310.15(B)(2)(a)and •L 7 310.15(B)(3)(c)of the(NEC)rated at 60c`75c°or 90e when applicable. 00 4 + L L d. Utility will be notified and grant permission before full activation of the PV system. fitLO e. Backfed breaker used as the method of the interconnection shall not read,"Line and Load". I nvile ter S z M '^ f. Corrosion resistant conduit shall be used for all underground runs and installations. WARNING - N v! Z g. All metallic raceways and equipment shall be bonded and electrically continuous per CEC 250.90 and -ELECTRICAL SHOCK HAZARD- AC DISCOr1fleCt S 25ound I h. Grounding electrode conductor will be continuous,except for splices or joints at busbars within listed THE DC CONDUCTORS OF THIS PHOTOVOLTAIC equipment per NEC 250.64 C. SYSTEM ARE UNGROUNDED AND MAYBE I. Photovoltaic arrays shall be provided with DC ground-fault protection.(CEC 690.5) -Photovoltaic System Specifications- O I j. All exterior conduit, fittings,and boxes shall be rain-tight and approved for use in wit locations. ENERGIZED. Rated Maximum Power-point Current(DC): 33.08 Amps -O 00-1 (CEC 314,15). Mounting Location:J-Box,Combiner Box and DC Disconned(s). Rated Maximum Power-point Voltage(DC): 333.3 Volts 0 k. Working Cleamaces around existing electrical equipment as well as new electrical equipment will be Applicable only with ungrounded power systems. Maximum S stem Volta a DC): 463.2 Volts U •� - < maintained Baccordance with CEC 110.26. hort Circuit IT DC : 11.06 Am s O I. Grounding Bushings will placed around pre-punched concentric knockouts on the DC side of the system. a) m C) , ,^ (CEC 250.97) --- Rated output Current AC : 52.5 Amps (`-Jt m. All exposed wiring shall be listed as sunlight resistant and all outdoor equipment shall be NEMIA 3R rated. Nominal Operating Voltage(AC): 240.0 Volts 0 U fn (CECnduit s,CEC 3s follows: WARNING �' �_ n. NI conduit shall be as follows: L_ 4) O , 1. PVC for below ground wiring,Metallic Flex for indoor locations,and EMIT for above ground. Conduit ty "(} runs shall be located as to reduce trip hazard,as minimized in length as possible and installed along - ELECTRICAL SHOCK HAZARD- 0 0 (/� bottom of load bearingmembers. IF GROUND FAULT IS INDICATED, '(New Da Solar 1 (855) 444-6329 . .0 V N o. Markings shall be placed on interior and exterior DC conduit,raceway,enclosures,and cable assemblies NORMALLY GROUNDED CONDUCTORS y U every 10 feet-within l foot of turns or bends and within l foot above and below penetrations of roof/ceiling SERVICE BY QUALIFIED PERSONNEL ONLY 0)w (u m U O assemblies,walls,or barriers-with minimum 3/8-inch-high while lettering on red background reading: MAY BE UNGROUNDEDAND ENERGIZED. 'V%ARNING:PHOTOVOLTAIC POWER SOURCE."(CEC 690.31) _ •3 U•� U N p. DC breakers shall be listed and rated for PV use.(CEC 705.12) Mounting Location:On the Inverter (NEC 690.53)(NEC 690.54)(NEC 690.56B)(NEC 705.10) O (D q. All equipment shall be identified on a warning placard clearly showing location of all pertinent equipment and Applicable only if system includes string inverter(s). Mounting Location:Service Panel -O O C disconnects. The placard shall be metal or plastic,with engraved letters in contrasting color to the placard. 'Actual Signage Design Located within Cut Sheet Packet O O U (� 1:13 r. PV connection in panel board shall be positioned at the opposite(load)end from the input feeder location or main circuit location.(CEC 705.12) 41 V fn s. If approved plans show de-rating of the main breaker,a placard label is required at the panel.(CEC 690.53, _ L i�, a) O CEC 690.17,CEC 705.10) -WARNING- INVERTER -CAUTION- - �_ .`� rn � c o •� I. AIIeMeri�or conduit�lacemenland s¢ingshall hvembienttemperature adjustments incontonnancewith OUTPUT CONNECTION -WARNING- , .9 Z v F5 the temperate compliance of the table 310.15(b)(16). — C u. Integrated and or micro-inverter systems shall have a rooftop AC disconnect and comply with THIS BREAKER HAS 3 U _ >_ () m CEC 690.14(d)(1)and(2). DO NOT RELOCATE THIS 1 BEEN DOWNSIZED DEDICATED SOLAR >, •� = c( L v. Photovoltaic system conductors shall be identified and grouped. Themeans of identification shall be L1J m G LE •(� permitted by separate color coding,marking tape,tagging,or other approved means. The means of TO AMPS SUB-PANEL. DO NOT grouping shall be wire ties or similar means at least once,and then at intervals not to exceed six feet. OVERCURRENT DEVICE DO NOTUPSIZE ADD NEW CIRCUITS. s` .� L 2. Grounding Methods. All grounding installations shall comply with the following grounding methods/requirements: _ U •� •� •� •� 0 a. All modules shall be grounded in accordance with the CEC and the manufacturers installation instructions. Mounting Location:Inverter Output Connection Mounting Location:Breaker Mounting Location:Dedicated b. Unless specified by the manufacturer,all inverters shall have a grounding electrode conductor with a _ O O O O O Applicable only if MIS has been reduced. Sub-Panel only when applicable. 4_ V- aF 4--, 4-- minimum size of#6 copper wire.(CEC 690.47) Correct Amperage will be engraved. Co = = = = • c. Electric service panels shall be grounded with the a grounding electrode(s)that complies with CEC Article M M (U CU M V 250.Grounding-rods shall be supplemented by a second grounding-rod installed at least 6 feet apart. WARNING: PHOTOVOLTAIC POWER SOURCE (CEC 690.47) col Q� d. If the existingmain service panel does not have verifiable grounding electrode,it shall be the contractor's v L-t V co M M ('7 co >y P 9 9 Mounting Location:Conduit Run r � � � co L responsibility to install a supplemental grounding electrode. Service grounding electrode must be verified Photovoltaic DC conductors entering the building shall be idenfified Mounting Location:Breaker •� t� O T- 0 L- at the time of inspection for all buildings. Buildings with a metallic water pipe system as the sole grounding every 10 ft.and within 1 foot of bends and above/below penetrations electrode shall have a supplemental electrode installed.(CEC 690.47) of roof/celing assemblies,walls,or barriers. Cl N N N N N U