PMT16-01972 City of Menifee Permit No.: PMT16-01972
29714 HAUN RD.
<ACCEiL/-> MENIFEE,CA 92586 Type: Residential Electrical
MENIFEE Date Issued: 07/2 212 0 1 6
PERMIT
Site Address: 28963 SKYKLARK ST,MENIFEE,CA Parcel Number: 333-631-033
92584 Construction Cost: $10,689.60
Existing Use: Proposed Use:
Description of SOLAR TR 31582-1 MENIFEE HILLS
Work: 16 MODULES,4.24KW
LOT 80
Owner Contractor
LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC
980 MONTECITO DR#302 25 ENTERPRISE
CORONA,CA 92879 ALISO VIEJO,CA 92656
Applicant Phone:9493498269
JEREMIAH ACAYTURRI License Number:728102
LENNAR HOMES OF CALIFORNIA INC
25 ENTERPRISE
ALISO VIEJO,CA 92656
Fee Description gly Amount lEl
Solar, Residential or Small Commercial 1 252.00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 2.00
General Plan Maintenance Fee-Electrical 1 12.60
$294.60
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bldg_Permit_Tempiate.rpt Page 1 of 1
BUILDING & SAFETY PERMIT/PL.PERMIT/PLAN CHECK . . • •
r�=�s
`Menifee
DATE 06/15/2016 PERMIT/PLAN CHECK NUMBER P"HU94-01cil
TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL [-]MULTI-FAMILY ❑MOBILEHOME ❑POOL/SPA []SIGN
SUBTYPE: ❑✓ ADDITION ❑ALTERATION [-]DEMOLITION ❑ELECTRICAL [-]MECHANICAL
[-]NEW ❑PLUMBING [I RE-ROOF-NUMBER OF SQUARES
DESCRIPTION OF WORK Solar Permit-Plan 3404-4.24 kW/16 PCS
Master Solar Permit: P M T I -out
PROJECTADDRESS 28963 Skylark St.,Menifee,CA 92584
ASSESSOR'S PARCEL NUMBER 333-631-033 LOT 80 TRACT 3 5 ^
PROPERTY OWNER'S NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr.,Suite 302, Corona, CA 92879
PHONE (951)817-3680 EMAIL leremiah.acayturd@lennar.com
APPLICANT NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr.,Suite 302, Corona, CA 92879
PHONE (951)817-3680 EMAIL leremiah.acayturri@lennar.com
CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? ❑✓ YES❑NO
BUSINESS NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879
PHONE (951)817-3680 EMAIL jeremiah.acayturi@lennar.com
CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B
VALUATION $ $ 10,689.60 SQ FT L SO.FT
APPLICANT'S SIGNATURE DATE 06/15/2016
CITY STAFF USE ONLY
DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER
BUILDING PLANNING ENGINEERING FIRE GREEN SMIP
INVOICE I =PAID AMOUNT
AMOUNT OCASH OCHECKN 0CREDIT CARD VISA/MC
PLAN CHECK FEES PAIDAMOUNT OCASH 0CHECKp O CREDIT CARD VISA/MC
OWNER BUILDER VERIFIED OYES O. NO DL NUMBER NOTARIZED LETTER O YES O NO
City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777
www.cityofinenifee.us Inspection Request Line 951-246-6213
SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED
ITEM OTY MFR. 1 MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE
SYSTEM SIZE 4.24 KW LOCATIONS INDICATED BY THE ILLUSTRATION.
MODULE 16 PCS. HYUNDAI HIS-S265RG(265W) Y
INVERTER 16 PCS. ENPHASE M2I5-60-2LL-S22-IG BUYER: LI I �I
ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY I DATE:
SUB-ARRAY INFORMATION BU LDII
ARRAY#I ARRAY#2 ARRAY#3
MOD OTY 16 NA NA BUYER: F,L N /�
TILT 213' NA' NA• ��I fi
AZIMUTH 254• NA' NA- City of Menifee DATE:
Building Dept
JUN 2 8 REVIEW
Received FAPPro al of tl
aPprovi I of,an
regulati nsand
26'-5'ARRAY jobsite I ntil car
12'-II' 27'-3'FLASHING
XiNij
SOLADTRANSITION
WIRE
TRANSITION BOX '
(UNDER ARRAY) }
Nil,
PV AC DISCONNECT ~ .r
EXTERIOR-GARAGE �
UTILITY METER 6
MAIN SERVICE PANEL-,--[ -------J \�
(VERIFIED BY BUILDER)
J
---- — — --
1
NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF
PLAN 3404 ELEVATION C ®�
ORIENTATION 4 LOT#OBO
MENIFEE HILLS LENNAR: ORIGINAL BY: ANGELA BURKE DATE:11.25.2015
980 MONTECITO DRIVE,#302 REVIEWED BY:JIMMY METER DATE:II.27.20I5
CORONA.CA 92879 REV.# BY DATE DESCRIPTION
namasu�
SOLAR
DWG TITLE: rPAGE #: SCALE: SITE LOCATION: 4571 Brwd"y Street
INDIVIDUAL 28963 SKYLARK STREET Bouitle4 GO 803M
PLOT PLAN 1116'= I'-0' MENIFEE.CA 303.447.0300
SYSTEM LAYOUT
MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS
ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL
LOCATION MENIFEE.CA INV.MAKE INVERTER SPEC ENPHASE
TEMP,AMBIENT HIGH(THAX) ASHRAE 2% •C 37 INV. MODEL INVERTER SPEC M215-60-2LL-SZ2-IG
TEMP.AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 INV.MAX POWER.(WAC MAX) INVERTER SPEC WATTS(AC) 225
TEMP.MODULE TEST(TEEST) MODULE SPEC °C 25 INV. INPUT V.(VOC MAX) INVERTER SPEC VOLTS(od 48
TEMP.DELTA LOW(TDELTA) THIN-TTEsT •C -27 INV.OUTPUT V.(Vac NOM) INVERTER SPEC VOLTS(AD) IFEF
MOD.MANUFACTURER. MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60
MOD.PART NUMBER MODULE SPEC HIS-S265RG INV.OUTPUT CURRENT,IAC INVERTER SPEC AMPS(AC) 0.9 ETY
MOD.POWER STC(P) MODULE SPEC WATTS(DC) 265 INV.PHASE QUANTITY INVERTER SPEC PHASE t
MOD.POWER PTC MODULE SPEC WATTS(DC) 238 1 COMPLIANCE INVERTER SPEC U1_17 7
MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(OC) 31.30 INV.GROUNDING INVERTER SPEC ISO
MOD.OPEN CCT.VOLTAGE(VOC) MODULE SPEC VOLTS(oc) 38.10 INV.OTY.MAX/BRANCH CCT. INVATYec OTY Ib
MOD.COEFF.VOLT/TEMP(COEF) MODULE SPEC V/°C -0.114 BRANCH CCT.OUTPUT.IMAXBC (IACINV.GTY8C) AMPS(AC) 14.G0
MOD.MAX VOLTAGE(VMAXMOO) (vac+(TD°COEF)) VOLTS(DO 41.18 INV.QUANTITY,TOTAL INV.OTYT QTY 16
MOD.OPERATING CURRENT(IMP) MODULE SPEC AMPS(OC) 8,50 TOTAL SYSTEM OUTPUT.IMAXTs I(IAC•INV.GTYT) AMPS(AC) 114.40
MOD.SHORT CCT.CURRENT On) MODULE SPEC AMPS(UU 9.00 G
MOD. MAXIMUM CURRENT(IMAX) (Isc•1.25) AMPS(DC) 11.25
MIN.AMPACITY REO'D,PER NEC (IMAX• 1.25) AMPS(00) 14.06
SERIES FUSE RATING.MAX MODULE SPEC AMPS(DU 15
ELECTRICAL EQUIPMENT SCHEDULE plans shallnOt eCOnsi
KEY CITY MANUFACTURER MODEL NOTES TRADE
I Ib HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR elation of any Pr Visions
2 16 ENPHASE M215-60-2LL-S22-IG PV INVERTER SOLAR
3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR Inances, This si t of app
4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT.NEMA 3R,240V.30A SOLAR 40n,
5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR
6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR
7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR
8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS:I X 15A-IP(ENVOY) SOLAR
9 NOTE CUTLER-HAMMER TBD PV BREAKER,I x 2OA-2P.LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR
10 I TBD TBO SERVICE PANEL.MIN. 125A BUS BLDR.ELLEL.
II TBD TBD UTILITY METER.IPH.120/240V,200A BLDR.EEL.
12 1 I 1 TBD I TBD I GROUNDING ELECTRODE UFER I BLDR.ELEC.
CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS
U CONDITION OF USE(COU): I(AMPACITY•TEMP. DERATE°FILL OERATE)Vs.REQ'D(IMAX) ITEM UNIT PANEL
2)TERMINALS(TERM): AMPACITY AT TERMINALS.VS.REO'D.(IMAX• 1.25) PANEL MFR. CUTLER-HAMMER
KEY SIZE CU/AL INSULATION CALC. AMPACITY W70 TEMP. I FILL RESULT I REQ'D I OCD BUS RATING AMPS 200
TYPE DERATES DERATE I DERATE I W (A) USED(A) MAIN DISCONNECT AMPS 200
A #12 CU T14WN-2 COU 30 0.76 1.0 1 22.80 114.40 ALLOWED PV PER NEC AMPS LO
TERM 25 25 18.00 20 PV OCPD DEVICE USED AMPS 20
B #10 CU NM-8 COU 40 0.91 1.0 36.40 14.40
TERM 35 35 18.00 20
C #10 CU I NM-B COU 40 0.91 1.0 36.40 114.40
TERM 35 35 18.00 20
CONDUCTOR SCHEDULE
KEY CONDUCTORS CU/AL 1 TYPE 1 LOCATION I TRADE
A I-0
12 ENGAGE CABLE.1-#6G.FREE AIR CU TC-ER ARRAY SOLAR
B 3-#10.1-#10 EGC I LU NM-B(ROMEX) I INTERIOR ISOLAR -
L 3-#10.1-#10 EGC CU NM-8(ROMEX) INTERIOR SOLAR 5 6 11
D CAT5E.ETHERNET CABLE CU CATSE INTERIOR SOLAR 7 o Y
e O
SEE NOTE 15 0
40 O
Q
2pA/$P
IN
G IS
A B C =12
I I I
ROOF EXTERIOR-GARAGE
ELECTRICAL DIAGRAM 4.24 KW
LOT#080
ORIGINAL BY: ANGELA BURKE DATE:11.25.2015
MENIFEE HILLS LENNAR: REVIEWED BY:JIMMY METER DATE:11.27.2015
CORONA,
NA,CA 92 DRIVE.#302 REV.# BY DATE DESCRIPTION
CORONA,CA 92879
namast;6
DWG TITLE: PAGE#: SCALE: SITE LOCATION: so��X
4571 Broadway Street
INDIVIDUAL 28963 SKYLARK STREET Boulder,CO W304
PLOT PLAN 2 NTS
ELECTRICAL MENIFEE,CA 303.447.0300
STRUCTURAL NOTES:
SOLAR CONTRACTOR-
U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C.
2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS.TO MAXIMUM EXTENT POSSIBLE.
3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT.
4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED.
5)PV ARRAY WILL BE A MINIMUM OF 3-ABOVE THE COMPOSITE SHINGLE ROOF SURFACE.
6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION
MANUAL.VERSION 227.3.PUB 140113-ICC,JANUARY 2014. �/�p fl(Y(A�aN.
7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH 01 SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(29 BEYOND THE LS7�\
OF THE PV ARRAY/SUB-ARRAY.
8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'.
ROOFING CONTRACTOR-
U DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3%
2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE
APROVED PRIOR TO PV SYSTEM INSTALLATION.
3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT 00 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK B
"_ :11tj
BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS.
4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE.
5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS.
6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE.BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO
INSTALLATION.
I to be a pc rmitfor,,
ne federal, itate or c
?d plans mt st be I(ep
ELECTRICAL NOTES:
GENERAL-
1)ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL).
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC.
3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC
WELD.
4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING.NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE
MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED.
5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE.
6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE.
SOLAR CONTRACTOR-
7)MODULE CERTIFICATIONS WILL INCLUDE UL1703, IEC61646,IEC61730.
B)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS.
9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS.
10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM.
IU MODULE AND ENPHASE WIRING SMALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS. WIRING SHALL NOT MAKE CONTACT WITH THE
ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER.
12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122.
13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING.OR MANUFACTURER'S RECOMMENDATIONS.
14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT.
15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR.
SIGNAGE-
16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES.
17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS.
18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT')'.
19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL Be MARKED'PHOTOVOLTAIC POWER SOURCE:OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'.
BUILDER ELECTRICAL AND SOLAR CONTRACTORS-
20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER.
21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26.
LENNAR: ORIGINAL BY: ANGELA BURKE DATE:II.2S.2OIS
MENIFEE HILLS REVIEWED BY:JIMMY METER DATE:11.27-2015
980 NA.CA I92 DRIVE.#302
CORONA,CA 92879 REV.# BY DATE DESCRIPTION
namast;e
SOIAS
DWG TITLE: PAGE#: I SCALE: SITE LOCATION:
INDIVIDUAL 4571 Broadway CO Street
PLOT PLAN 3 NTS 28963 SKYLARK STREET Boulder,
NOTES MENIFEE,CA 03.447.0300
CAUTION:
POWER TO THIS BUILDING IS SUPPLIED BY THE
UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS
ARE LOCATED AS SHOWN.
)k� lac
E
SOLADECK WIRE ihP
TRANSITION BGX
(UNDER ARRAY)
PV AC DISCONNECT
EXTERIOR-GARAGE
UTILITY METER 8
MAIN SERVICE PANEL
(VERIFIED BY BUILDER)
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
I-877-SLR-POWR
PV POWER SOURCE - AC SPECS
AC OPERATING VOLTAGE: 240 V
AC OPERATING CURRENT: 14.4 A
NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION
MENIFEE HILLS LENNAR: ORIGINAL BY: ANGELA BURKE I DATE:11.25.2015
980 MONTECITO DRIVE,#302 REVIEWED BY:JIMMY METER I DATE:11.27.2015
, t1
CORONA,CA 92879 REV.# BY DATE I DESCRIPTION
namasbg
DWG TITLE: PAGE#: I SCALE: SITE SM..
LOCATION: 4571 Broed" Street
INDIVIDUAL 28963 SKYLARK STREET Y
PLOT PLAN 4 NTS Boulder,CO 80
PLACARDS MENIFEE.CA 303.447.03DO