Loading...
PMT16-01969 City of Menifee Permit No.: PMT16-01969 29714 HAUN RD. Type: Residential Electrical <ACCEL/-! MENIFEE,CA 92586 MENIFEE Date Issued: 07/22/2016 PERMIT Site Address: 28927 SKYKLARK ST,MENIFEE,CA Parcel Number: 333-631-030 92584 Construction Cost: $14.593.40 Existing Use: Proposed Use: Description of SOLAR TR 31582-1 MENIFEE HILLS Work: 14 MODULES,3.71KW LOT 77 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO OR#302 25 ENTERPRISE CORONA, CA 92879 ALISO VIEJO,CA 92656 Applicant Phone:9493498269 JEREMIAH ACAYTURRI License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ALISO VIEJO,CA 92656 Fee Description ,City Amount Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 2.00 General Plan Maintenance Fee-Electrical 1 12.60 $294.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Pernit_Template.rpt Page 1 of 1 BUILDING • APPLICATION Menifee DATE 06/15/2016 PERMIT/PLAN CHECK NUMBER 1ilow (Abi TYPE: []COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILE HOME ❑POOL/SPA [-]SIGN SUBTYPE: ❑✓ ADDITION []ALTERATION []DEMOLITION []ELECTRICAL ❑MECHANICAL ❑NEW []PLUMBING ❑RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit-Plan 3105-3.71 kW/14 PCS Master Solar Permit: PMTH—oo-7og PROJECT ADDRESS 4 28927 Skylark St., Menifee, CA 92584 ASSESSOR'S PARCEL NUMBER 333-631-030 LOT 77 TRACT 31S8L- PROPERTY OWNER'S NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302, Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acaytum@lennaccom APPLICANT NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRAcrOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? ❑✓ YES❑NO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr, Suite 302,Corona, CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ $14,593.40 L SO FT APPLICANT'S SIGNATURE DATE 06/15/201QTYSTAFF USE ONLY DEPARTMENT DISTRIBUTION CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEE G FIRE GREEN SMIP INVOICE U PAID AMOUNT AMOUNT 1� O CASH O CHECK# O CREDIT CARD VISA/MC PLAN CHECK FEES PAID AMOUNT O CASH O CHECKtr O CREDITCARD VISA/MC OWNER BUILDER VERIFIED OYES O NO DL NUMBER NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Department 29714 Houn Rd. Menifee, CA 92586 951-672-6777 www.citycfinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 3.71 KW 1 LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 14 PCS.1 HYUNDAI I HIS-S265RG(265W) BUYER: INVERTER 14 PCSj ENPHASE I M215-60-2LL-S22-IG ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: SUB-ARRAY INFORMATION t �v MOD OTY ARRAOY#I ARRAY#2 ARR ZY#3 BUYER: l.I 1'(� I yy V F ME IFEE TILT 23° 1 23° 23° A D S AZIMUTH 112° 202• 22• DATE: FLAN APPRIC VAL City of Menifee Building Dept REVIEWEDED EW JUN 2 8 'IQ. R e c e i v e 'Approval of these pl ins shal 23'-2-ARRAY 3• approval of,any viola ion of F———————— ————————— - regulations and ordin nces. ' jobsite until completi n. I I I I � I � t I SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) a a — > o a c �o a I � — I PV AC DISCONNECT n L J EXTERIOR-GARAGE I UTILITY METER B MAIN SERVICE PANEL — J (VERIFIED BY BUILDER) NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF N PLAN 3105 ELEVATION A ORIENTATION I LO T#077 ORIGINAL BY: ANGELA BURKE DATE:11.25.2015 MENIFEE HILLS LENNAR: 980 MONTECITO DRIVE,#302 REVIEWED BY:JIMMY METER I DATE:11.27.2015 CORONA,CA 92879 REV.# BY DATE DESCRIPTION namast6 tame DWG TITLE: PAGE#- SCALE: SITE LOCATION: INDIVIDUAL 4577 Ber,CO8 304 28927 SKYLARK STREET Bo303. 7.03DO q PLOT PLAN /I6'=I'-0- MENIFEE.CA 303.947.0300 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE,CA INV.MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% •C 37 INV.MODEL INVERTER SPEC M215-60.2LL-S22-IG TEMP.AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 INV.MAX POWER,(WAG MAX) INVERTER SPEC WATTS(Ac) 225 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V,(Voc MAX) INVERTER SPEC VOLTS(od 48 TEMP,DELTA LOW(ToELTA) TmIN-TTEST °C -27 INV. OUTPUT V.(VAc MOM) INVERTER SPEC VOLTS(AC) 240 MOD. MANUFACTURER MODULE SPEC HYUNDAI INV. OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD. PART NUMBER MODULE SPEC HIS-S265RG INV.OUTPUT CURRENT,IAC INVERTER SPEC AMPS(AC) 0.9 MOD. POWER STC(P) MODULE SPEC WATTS(DO 265 INV.PHASE QUANTITY INVERTER SPEC PHASE I ' DEI MOD.POWER PTC MODULE SPEC WATTS(DC) 230 COMPLIANCE INVERTER SPEC U1_1741AEEEI54 MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(00 1 31.30 INV.GROUNDING INVERTER SPEC ISOLATED MOD.OPEN CCT.VOLTAGE WOO MODULE SPEC VOLTS(DO 38.10 INV.OTY,MAX/BRANCH CCT. INV.QTYBC OTY 14 MOD.COEFF.VOLT/TEMP(COEF) MODULE SPEC V/°C -0.114 BRANCH CCT.OUTPUT.IMAXec (IAC•INV.QTYBC) AMPS(AG) 12.60 MOD.MAX VOLTAGE(VMAXMOB) (VOC+(TO•COEF)) VOLTS QIC) 41.18 INV,QUANTITY.TOTAL I INV.QTYT I QTY 1 14 MOD.OPERATING CURRENT(IMP) MODULE SPEC AMPS(DO 8.50 TOTAL—SYSTEM IMAXTs I(IAC-INV.OTYT) AMPS(AC) 1 12.60 MOD.SHORT CCT.CURRENT(Isc) MODULE SPEC AMPS(00 9.00 MOD. MAXIMUM CURRENT(TMAX) (ISC• 1.25) AMPS(DO 11.25 MIN.AMPACITY REQ'D,PER NEC (IMAX• 1.25) AMPS(M) 14.06 SERIES FUSE RATING.MAX MODULE SPEC AMPS(Oc) 15 ELECTRICAL EQUIPMENT SCHEDULE KEY QTY MANUFACTURER MODEL NOTES TRADE 1 14 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR t be I onstrue 2 14 ENPHASE M215-60-2LL-S22-IG PV INVERTER SOLAR ;ovi ions of 3 3 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR K 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT.NEMA 3R.240V,30A SOLAR .Set BP(!fC 5 1 ENPHASE ENVOY PV DATA MONITOR. 120V SOLAR 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR 8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS:I X 15A-IP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBD PV BREAKER,I X 2OA-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 I TBD TBD SERVICE PANEL.MIN. 125A BUS BLDR.ELEC. II I TBD TBD UTILITY METER,IPH,120/24OV,200A 1 BLDR.ELEC. 12 1 1 1 TBD I TBD I GROUNDING ELECTRODE UFER I BLDR.ELEC. CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS U CONDITION OF USE(COU): I (AMPACITY•TEMP.DERATE•FILL DERATE)vs.REO'D(IMAX) ITEM UNIT PANEL 2)TERMINALS(TERM): AMPACITY AT TERMINALS.VS.REO'D,([MAX• 1,25) PANEL MFR. CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALL. AMPACITY W/O TEMP. FILL RESULT REO'D OCD BUS RATING AMPS 200 TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200 A #12 CU THWN-2 COU 30 0.76 1.0 22.80 12.60 ALLOWED PV PER NEC AMPS 40 TERM 25 25 15.75 20 PV OCPD DEVICE USED AMPS 20 B #10 CU NM-B CCU 40 0.91 1.0 36.40 12.60 TERM 35 35 15.75 20 C #10 CU NM-8 COU 40 0.91 1.0 36.40 12.60 TERM 35 35 115.75 1 20 CONDUCTOR SCHEDULE KEY 1 CONDUCTORS CU/AL TYPE LOCATION TRADE A 1-#12 ENGAGE CABLE,1-#6G.FREE AIR CU TC-ER ARRAY SOLAR B 3410,I-#10 EGG I CU I NM-B(ROMEX) IINTERIOR SOLAR C 3410.1410 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR D CAT5E,ETHERNET CABLE I CU I CAT5E I INTERIOR I SOLAR 2 3 5 i O- G SEE NOTE 15 10 o I ,G© O WA, N G G-� ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 3.71 KW LOT#077 ORIGINAL BY: ANGELA BURKE DATE:11.25.2015 MENIFEE HILLS LENNAR: REVIEWED BY:JIMMY METER DATE:11.27.2015 CORONA, NA,CA 92 DRIVE.#302 REV.# BY DATE DESCRIPTION CORONA,CA 92879 Onamast;d sou. DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Bm dmy Street INDIVIDUAL 28927 SKYLARK STREET BOYI.I'er,CO 80304 PLOT PLAN 2 NTS ELECTRICAL MENIFEE,CA 305447.0300 STRUCTURAL NOTES: SOLAR CONTRACTOR- U ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL,VERSION 227.3,PUB 140113-ICC,JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(P)SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(2')BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. RT ENT ROOFING CONTRACTOR- U DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(I')OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE.BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. Qs a p.rmit for, edeml,state or ans In iust be k( ELECTRICAL NOTES: GENERAL- 1)ALL PV EDUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SMALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646, IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. IU MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT e. 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED*PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10% BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER, 20 SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY: ANGELA BURKE I DATE:11.25.2015 MENIFEE HILLS LENNAR: 980 MONTECITO DRIVE,#302 REVIEWED BY:JIMMY METER I DATE:11.27.2015 CORONA.CA 92879 REV.# BY DATE DESCRIPTION tftmasbifiso". DWG TITLE: PAGE*: I SCALE: SITE LOCATION: 4571 Smaeway Slmet INDIVIDUAL 28927 SKYLARK STREET Bouldur,CO 80304 PLOT PLAN 3 NTS MENIFEE.CA NOTES 303.d47.0300 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. ,G /1D ;T 1 SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER e MAIN SERVICE PANEL (VERIFIED BY BUILDER) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP I-877-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: 12.6 A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY: ANGELA BURKE DATE:11.25.2O15 MENIFEE HILLS LENNAR: REVIEWED BY:JIMMY METER DATE:11.27.2O15 CORONNA.A.C CA 980 DRIVE,#302 REV.# BY DATE DESCRIPTION •, A 92879 namaste some DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Bmadway Street INDIVIDUAL 28927 SKYLARK STREET Bo der,CO 8O3O4 PLOT PLAN A NTS MENIFEE,CA 303.447.0300 PLACARDS