PMT16-01968 City of Menifee Permit No.: PMT16-01968
29714 HAUN RD. Type: Residential Electrical
< ►CCELAI" MENIFEE,CA 92586
0""'"-"1Wt-" MENIFEE Date Issued: 07/22/2016
PERMIT
Site Address: 28915 SKYKLARK ST,MENIFEE, CA Parcel Number: 333-631-029
92584 Construction Cost: $10,689.60
Existing Use: Proposed Use:
Description of SOLAR TR 31582-1 MENIFEE HILLS
Work: 16 MODULES,4.24KW
LOT 39
Owner Contractor
LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC
980 MONTECITO DR#302 25 ENTERPRISE
CORONA,CA 92879. ALISO VIEJO,CA 92656
Applicant Phone:9493498269
JEREMIAH ACAYTURRI License Number.728102
LENNAR HOMES OF CALIFORNIA INC
25 ENTERPRISE
ALISO VIEJO,CA 92656
Fee Description Oft Amount 151
Solar, Residential or Small Commercial 1 252.00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 2.00
General Plan Maintenance Fee-Electrical 1 12.60
$294.60
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing builiding operations being carried on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bldg_Pennit Template.rpt Page 1 of 1
APPLICATION
BUILDING & SAFETY PERMIT/PLAN CHECK
Menifee
DATE 06/15/2016 PERMIT/PLAN CHECK NUMBER
TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILE HOME ❑POOL/SPA ❑SIGN
SUBTYPE: ❑✓ ADDITION ❑ALTERATION ❑DEMOLITION [—]ELECTRICAL [—]MECHANICAL
❑NEW [—]PLUMBING [:]RE-ROOF-NUMBEROFSQUARES
DESCRIPTION OF WORK Solar Permit-Plan 3404-4.24 kW/16 PCS
Master Solar Permit: P MT
PROJECT ADDRESS 28915 Skylark St., Menifee, CA 92584
ASSESSOR'S PARCEL NUMBER 333-631-029 LOT 39 TRACT �—
PROPERTY OWNER'S NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr.,Suite 302, Corona, CA 92879
PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com
APPLICANT NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr.,Suite 302,Corona, CA 92879
PHONE (951)817-3680 EMAIL jeremiah.scayturri@lennar.com
CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? DYES❑NO
BUSINESS NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879
PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com
CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B
VALUATION$ $10,689.60 FT L SQ FT
APPLICANT'S SIGNATURE DATE 06/15/2016
CITY STAFF USE ONLY
y
DEPARTMENT DISTRIBUTIO SMIP �SQ CITY OF MENIFEE BUSINESS LICENSE NUMBER
BUILDING PLANNING ENGINEERING FIRE GREEN I
INVOICE ba PAID AMOUNT
AMOUNT • OCASH OCHECK# OCREDITCARD VISA/MC
PLAN CHECK FEES PAID AMOUNT O CASH O CHECK# O CREDIT CARD VISA/MC
OWNER BUILDER VERIFIED O YES O NO DL NUMBER NOTARIZED LETTER O YES O NO
City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777
www.cityofinenifee.us Inspection Request Line 951-246-6213
SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED
ITEM OTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE
SYSTEM SIZE 4.24 KW I I LOCATIONS INDICATED BY THE ILLUSTRATION.
MODULE 16 PCS.1 HYUNDAI I MIS-S265RG(265W) BUYER: `i NIFE
INVERTER 16PCS. ENPHASE M215-60-2LL-S22-IGrY
ROOF TYPE TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE:
SUB-ARRAY INFORMATION BUILDING AND AFE
ARRAY#I 1 ARRAY AY#2 ARR #3
MOD OTY 16 NA NA BUYER: PLAN
TILT 23' NA- NA' L/"UY h1r-t•I�VV
AZIMUTH 1 108° NA- NA' DATE:
city of Menilee REVIEWED
Building Dept A 0
JUN 2 8 21],i 'Approval of these plans sha I not b(
approval of,any violation of My pro,
Received regulations and ordinances. rhis set
26-5-ARRAY 4• jobsite until completion.
---- -------
I I
I I
I t I
I
I I
I I
SOLADECK WIRE
TRANSITION BOX
(UNDER ARRAY)
J I PV DISCONNECT
I EXTEE RIOR-GARAGE
L I UTILITY METER A
I MAIN SERVICE PANEL
a0 _ (VERIFIED BY BUILDER) _
9
NOTE: DIMENSIONS ARE SHOWN IN PLANE OF ROOF N
PLAN 340E ELEVATION C-REVERSE
ORIENTATION I LOT#039
ORIGINAL BY: ANGELA BURKE DATE:11.25.2015
MENIFEE HILLS LEN14AR:
980 MONTECITO DRIVE,#302 REVIEWED BY:JIMMY METER I DATE:11.27.2015
CORONA.CA.92879 REV.# BY DATE DESCRIPTION
Vnamast;6
SOLAR
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street
INDIVIDUAL 28915 SKYLARK STREET Boulder,CO 80
PLOT PLAN 1 1116'=I.-C, MENIFEE.CA 3D3.447.0300
SYSTEM LAYOUT
MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS
ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL
LOCATION MENIFEE,CA INV.MAKE INVERTER SPEC ENPHASE
TEMP,AMBIENT HIGH(TMAR) ASHRAE 2% 'C 37 INV.MODEL INVERTER SPEC M215-60-2LL-S22-IG
TEMP.AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 INV.MAX POWER,(WAC MAX) INVERTER SPEC WATTS(AC) 225
TEMP.MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V,(VOC MAX) INVERTER SPEC VOLTS(DC) 48
TEMP.DELTA LOW(TEELTA) THIN-TTEST °C -27 INV. OUTPUT V.(VAC MOM) INVERTER SPEC VOLTS(AC) 240
MOD.MANUFACTURER MODULE SPEC HYUNDAI INV. OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 EPAI
MOD.PART NUMBER MODULE SPEC HIS-S265RG INV. OUTPUT CURRENT.IAC INVERTER SPEC AMPS(AC) 0.9
MOD.POWER STC(P) MODULE SPEC WATTS(DC) 265 INV. PHASE QUANTITY INVERTER SPEC PHASE I
MOD.POWER PTC MODULE SPEC WATTS(DC) 238 COMPLIANCE INVERTER SPEC UL1741/IEEE1547
MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS CDC) 31.30 INV. GROUNDING INVTER SPEC ISOLATED
MOD.OPEN CCT.VOLTAGE(VOC) MODULE SPEC VOLTS CDC) 38.10 INV. CITY,MAX/BRANCH CCT. INERV.QTYeCi OTY 16
MOD.COEFF.VOLT/TEMP(COEF) MODULE SPEC V/°C -0.I14 BRANCH CCT.OUTPUT,IMAXBC UAC•INV.QTYaC) I AMPS(AC) 1 14.40
MOD.MAX VOLTAGE(VMAXMOD) (Vac t(TD'COEF)) VOLTS W 41.18 INV.QUANTITY,TOTAL INV.QTYT I OTY IIb
MOD.OPERATING CURRENT(IMP) MODULE SPEC AMPS CDC) 8.50 TOTAL SYSTEM OUTPUT,IMAXTS (IAC'INV.QTYT) I AMPS(AC) I14.40
MOD. SHORT CCT. CURRENT(ISC) MODULE SPEC AMPS(139) 9.00
MOD.MAXIMUM CURRENT(IMAX) (Isc°1.25) AMPS(OC) 11.25
MIN.AMPACITY REO'D,PER NEC (IMAX•1.25) AMPS(DC) 14.06
SERIES FUSE RATING,MAX MODULE SPEC AMPS(DC) 15
ELECTRICAL EQUIPMENT SCHEDULE Bstr,cato6(
KEY OTY MANUFACTURER MODEL NOTES TRADE 'nso thefec
1 16 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR
2 16 ENPHASE M215-60-2LL-S22-IG PV INVERTER SOLAR ppr ved pie
3 1 RSTC/SOLADECK 0766-3% PV ROOF JUNCTION BOX.NEMA 3R SOLAR
4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT.NEMA 3R,24OV,30A SOLAR
5 1 ENPHASE ENVOY PV DATA MONITOR.IZOV SOLAR
6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR
7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR
8 NOTE CUTLER-HAMMER TOD PV BRANCH CIRCUIT BREAKERS:I x ISA-IP(ENVOY) SOLAR
9 NOTE CUTLER-HAMMER TBD PV BREAKER,I X ZOA-2P.LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR
10 TBD TBD SERVICE PANEL,MIN. 125A BUS BLDR.ELEC.
11 TBD TBD UTILITY METER,IPH.120/24OV.200A BLDR.ELEC.
12 1 I 1 TBD I TBD I GROUNDING ELECTRODE UFER BLDR.ELEC.
CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS
D CONDITION OF USE(COW: I(AMPACITY°TEMP.DERATE-FILL DEBATE)VS.REO'D(IMAX) ITEM UNIT PANEL
2)TERMINALS(TERM): AMPACITY AT TERMINALS VS. REO'D,(IMAX' 1.25) PANEL MFR. CUTLER-HAMMER
KEY SIZE CU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REOM OCD BUS RATING AMPS 200
TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200
A #12 CU I THWN-2 COU 30 0.76 1.0 22.80 1 14.40 1 ALLOWED PV PER NEC AMPS 40
TERM 25 25 W14.40
20 PV OCPD DEVICE USED AMPS 20
B #10 CU NM-B COU 40 0.91 1.0 36.40
TERM 35 35 20
C #10 CU NM-B COU 40 0.91 1.0 36.40 TERM 35 20
CONDUCTOR SCHEDULE
KEY 1 CONDUCTORS CU/AL TYPE LOCATION TRADE
A I-#12 ENGAGE CABLE,I-#6G,FREE AIR CU TC-ER ARRAY SOLAR
B 1 34I0.1-#10 EGC CU I NM-B(ROMEX) INTERIOR I SOLAR
C 1 3-#10,1-#10 EGC CU I NM-B(ROMEX) INTERIOR I SOLAR
D 1 CAT5E.ETHERNET CABLE I CU I CAT5E INTERIOR I SOLAR 5 5 II
0• c a O
SEE NOTE 15 I 10
O ® � 2�F
O L
IN
6 G �
ROOF EXTERIOR-GARAGE
ELECTRICAL DIAGRAM 4.24 KW
LOT#039
ORIGINAL BY: ANGELA BURKE DATEAI.25.2015
MENIFEE HILLS LENNAR:
980 MONTECITO DRIVE,#302 REVIEWED BY:JIMMY METER I DATE:11.27.2015
CORONA,CA 92879 REV.# BY DATE DESCRIPTION
namasbAR
SOLAR
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Sft e
INDIVIDUAL 28915 SKYLARK STREET Boulder,CO W304
PLOT PLAN 2 NTS
ELECTRICAL MENIFEE,CA 303.447.0300
STRUCTURAL NOTES:
SOLAR CONTRACTOR-
S ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C.
2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE.
3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT.
4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED.
5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE.6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION -MENT
MANUAL.VERSION 227.3.PUB 140113-ICC.JANUARY 2014.
7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH 01 SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(2')BEYOND THE EDGE
OF THE PV ARRAY/SUB-ARRAY.
8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'.
ROOFING CONTRACTOR-
D DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3.
2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION.IT SHALL BE
APROVED PRIOR TO PV SYSTEM INSTALLATION. (.
3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT 00 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE.DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO D
BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS.
4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE.
5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS.
6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO it for.Or
INSTALLATION.
to Or City
s.Le kept I
ELECTRICAL NOTES:
GENERAL -
0 ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL).
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/LEG,
3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC
WELD.
4)NON-CURRENT CARRYING METAL PARTS SMALL BE CHECKED FOR PROPER GROUNDING.NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE
MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED.
5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE.
6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE.
SOLAR CONTRACTOR-
7)MODULE CERTIFICATIONS WILL INCLUDE UL1703, IEC61646,IEC61730.
8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS.
9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS.
10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM.
IU MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE
ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER.
12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122.
13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS.
14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT.
15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR.
SIGNAGE-
16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES.
17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS.
18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT t.
19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE:OR EQUIVALENT:WIRING/RACEWAYS SMALL BE MARKED EVERY 10'.
BUILDER ELECTRICAL AND SOLAR CONTRACTORS-
20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER.
21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26.
ORIGINAL BY: ANGELA BURKE DATE:11.
LENNAR: 25.20i5
MENIFEE HILLS REVIEWED BY:JIMMY METER DATE:11.27.2015
980 MONTECITO DRIVE.#302
CORONA,CA 92879 REV.# BY DATE DESCRIPTION
namaste
Sor•v
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street
INDIVIDUAL 28915 SKYLARK STREET Boulder,CO 80304
PLOT PLAN 3 NTS MENIFEE•CA
NOTES 303.447.0300
CAUTION:
POWER TO THIS BUILDING IS SUPPLIED BY THE
UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS
ARE LOCATED AS SHOWN.
V
SOLADECK WIRE
TRANSITION BOX
(UNDER ARRAY)
PV AC DISCONNECT
EXTERIOR-GARAGE
UTILITY METER 8
MAIN SERVICE PANEL
(VERIFIED BY BUILDER)
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
1-877-SLR-POWR
PV POWER SOURCE - AC SPECS
AC OPERATING VOLTAGE: 240 V
AC OPERATING CURRENT: 14.4 A
NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION
ORIGINAL BY: ANGELA BURKE I DATE:11.25.2015
MENIFEE HILLS LENNAR: REVIEWED BY:JIMMY METER DATE:11.27.2015
CO NA.CA I92 DRIVE,#302
CORONA.CA 92879 REV.# BY DATE DESCRIPTION
namas.w
AoiAN
DWG TITLE: PAGE*: I SCALE: SITE LOCATION: 4571 B.dmy Street
INDIVIDUAL 28915 SKYLARK STREET Boulder,CO 8004
PLOT PLAN 4 NTS PLACARDS MENIFEE,CA 303.447.0300