Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
PMT16-01967
City of Menifee Permit No.: PMT16-01967 29714 HAUN RD. �CCEL/? MENIFEE,CA 92586 Type: Residential Electrical MENIFEE Date Issued: 0 7/2 212 01 6 PERMIT Site Address: 28903 SKYKLARK ST,MENIFEE, CA Parcel Number: 333-631-028 92584 Construction Cost: $8,017.20 Existing Use: Proposed Use: Description of SOLAR TR 31582-1 MENIFEE HILLS Work: 12 MODULES,3.18KW LOT 38 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA,CA 92879 ALISO VIEJO,CA 92656 Applicant Phone:9493498269 JEREMIAH ACAYTURRI License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ALISO VIEJO,CA 92656 Fee Description gtv Amount f5l Solar,Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL _ 1 2.00 General Plan Maintenance Fee-Electrical 1 12.60 $294.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carded on thereunder when in violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise staled,a permit for construction under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permit_Template.rpt Page 1 of 1 APPLICATIONBUILDING & SAFETY PERMIT/PLAN CHECK Menifee DATE 06/15/2016 PERMIT/PLAN CHECK NUMBER TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILE HOME ❑POOL/SPA ❑SIGN SUBTYPE: ❑✓ ADDITION []ALTERATION ❑DEMOLITION ❑ELECTRICAL [—]MECHANICAL [—]NEW ❑PLUMBING ❑RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit-Plan 2033X-3.18 kW/12 PCS Master Solar Permit: t P MT 14 —007 Q PROJECT ADDRESS 28903 Skylark St., Menifee, CA 92584 ASSESSOR'S PARCEL NUMBER 333-631-028 LOT 38 TRACT 3 �Sg2 PROPERTY OWNER'S NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr., Suite 302, Corona, CA 92879 PHONE (951)817-3680 EMAIL leremiah.acayturri@lennar.com APPLICANT NAME Lerner Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL Jeremiah.acayturri@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? ❑✓ YES❑NO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302, Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lenner.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ $8.017.20 SQ FT SQ FT APPLICANT'S SIGNATURE DATE 06/15/2016 1 f14 DEPARTMENT DISTRIBUTION ^ Y' CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN (� SMIP INVOICE PAIDAMOUNT O, AMOUNT OCASH OCHECK# ,CREDIT CARD VISA/MC PLAN CHECK FEES PAIDAMOUNT OCASH OCHECK# OCREDITCARD VISA/MC OWNER BUILDER VERIFIED O YES O NO DL NUMBER NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MFR. 1 MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 3.IBKW I I LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 12PCS.1 HYUNDAI I HIS-S265RG(265W) BUYER: [ ry� INVERTER I2 PCS. ENPHASE M2I5-60-2LL-S22-IG f 1 1ry Of IVI` ROOF TYPE ,_ TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: 1 I SUB-ARRAY INFORMATION BUILDING 4 ARRAY#I ARRAY#2 ARRAY#3 " MOD CITY 12 NA NA BUYER: (^�'' APR( TILT 23' NA' NA' FLAN A R( AZIMUTH 1 198• 1 NA' I NA' DATE: City of Menitee Building Dept rREVIE JUN 2 3 IJ �, r3 'Approval of hese pl R e c e i v-e7% ' approval of,a ly viola regulations ai d ordin jobsite until c Impleti I I I I I I I I I I I I I I � I I I I I I I I I I I I L____J N aLL Js PV AC DISCONNECT w EXTERIOR-GARAGE v UTILITY METER 6 �' o MAIN SERVICE PANEL (VERIFIED BY BUILDER) / 10'-10' 3' SOLADECK WIRE-,/ N BOX Q TRANSITION eJ (UNDER ON AY) �r NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN 2034 ELEVATION A ORIENTATION I LOT#038 ORIGINAL BY: ANGELA BURKE DATE:11.25.2015 MENIFEE HILLS LENNAR: 980 REVIEWED BY:JIMMY METER DATE:F27.2015 CORONA. q,C CA A 92874 DRIVE.#302 REV.# BY DATE I DESCRIPTIONlu namastd SOLAR DWG TITLE: PAGE#: I SCALE: SITE LOCATION: tviat INDIVIDUAL 4571Ber,DO8dway 304 28903 SKYLARK STREET Boulder, 7030304 PLOT PLAN I/16'=I'-0' MENIFEE,CA 303.447.0300 SYSTEM LAYOUT MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE.CA INV.MAKE INVERTER SPEC ENPHASE TEMP.AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INV.MODEL INVERTER SPEC M215-60-2LL-S2 =1 TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN °C -2 INV.MAX POWER.(WAC MAX) INVERTER SPEC WATTS(AC) 225 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V.(VOC MAX) INVERTER SPEC VOLTS In) 4B TEMP,DELTA LOW(TDELTA) THIN-TTEST 'C -27 INV. OUTPUT V.(VAC MGM) INVERTER SPEC VOLTS(AC) 240 ETY MOD.MANUFACTURER MODULE SPEC HYUNDAI INV. OUTPUT FREQUENCY INVERTER SPEC HERTZ 60 MOD.PART NUMBER MODULE SPEC HIS-S265RG INV. OUTPUT CURRENT,IAC INVERTER SPEC AMPS(AC) 0.9 MOD.POWER STC(P) MODULE SPEC WATTS(00 265 INV.PHASE QUANTITY INVERTER SPEC PHASE I MOD.POWER PTC MODULE SPEC WATTS(00 238 COMPLIANCE INVERTER SPEC UL174I/IEEE 47 MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(DC) 31.30 INV. GROUNDING INVERTER SPEC ISOLATED MOD.OPEN CCT.VOLTAGE(VOC) MODULE SPEC VOLTS(DC) 38.10 INV.CITY,MAX/BRANCH CCT. INV.OTYet CITY 12 MOD.COEFF.VOLT/TEMP(COEF) MODULE SPEC V/°C -0.114 BRANCH CCT.OUTPUT,IMA%BD (IAC•INV.CITYBC) AMPS(AU IO.BO MOD.MAX VOLTAGE(VMAXMOD) (VO6♦(T0•COEF)) VOLTS(oC) 41.18 INV.QUANTITY.TOi I INV.OTYT I QTY 1 12 MOD.OPERATING CURRENT(IMP) MODULE SPEC AMPS(DD) 8.50 TOTAL SYSTEM OUTPUT.IMAXTS I(IAC•INV.OTYT) I AMPS(AC) 1 10.80 MOD.SHORT CCT. CURRENT(ISC) MODULE SPEC AMPS(00 9.00 MOD, MAXIMUM CURRENT(TMAX) (ISC•1.25) AMPS(00 11.25 MIN.AMPACITY REO'D,PER NEC (IMAx•1.25) AMPS(00 14.06 SERIES FUSE RATING,MAX MODULE SPEC AMPS(oC7 15 5haN n be Con ELECTRICAL EQUIPMENT SCHEDULE Iofany rovisiol KEY QTY MANUFACTURER MODEL NOTES TRADE es. THIS Set Of a, 1 12 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR 2 12 ENPHASE M215-60-2LL-S22-IG PVINVERTER SOLAR 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,240V,30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR 8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS-,I x 15A-IP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBD PV BREAKER.I x 20A-2P.LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 I TBD TBD SERVICE PANEL,MIN. 125A BUS BLDR.ELEC. II 1 TBD TBD UTILITY METER,IPH. 120/24OV,200A BLDR.ELEC. 12 1 I 1 TBD TBD I GROUNDING ELECTRODE UFER I BLDR.ELEC. CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS 1)CONDITION OF USE(COU): I(AMPACITY • TEMP.DERATE•FILL DERATE)vim.REO'D(IN") ITEM UNIT PANEL 2)TERMINALS(TERM): I AMPACITY AT TERMINALS.vs.REO'D.OMAX• 1.25) PANEL MFR. CUTLER-HAMMER KEY SIZE CU/AL INSULATION CALL. AMPACITY W/O TEMP. FILL RESULT REO'D OCD BUS RATING AMPS 200 TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 20D A #12 CU THWN-2 COU 30 0.76 1.0 22.80 10.80 ALLOWED PV PER NEC AMPS 40 TERM 25 25 13.50 20 PV OCPD DEVICE USED AMPS 1 20 B #10 CU NM-B COU 1 40 0.91 1.0 36.40 10.80 TERM 35 35 13.50 20 C #10 CU NM-B COU 1 40 0.91 1.0 36.40 10.80 TERM 135 35 13.50 20 CONDUCTOR SCHEDULE KEY CONDUCTORS CU/AL TYPE LOCATION TRADE A I-#12 ENGAGE CABLE.1-#6G.FREE AIR CU TC-ER ARRAY SOLAR B 3-#10,1-#IQ EGC I CU I NM-B(ROMEX) I INTERIOR ISOLAR 5 © II C 3-#10.1-#10 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR C= p D CAT5E,ETHERNET CABLE Cu CAT5E INTERIOR SOLAR 7 O SEE NOTE 15 I 10 ® 5A/lP O O 9 O � N 3 'N A B T10 I I 1 ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 3.18 KW LOT#038 MENIFEE HILLS LENNAR: ORIGINAL BY: ANGELA BURKE DATE:11.25.2015 980 MONTECITO DRIVE.#302 REVIEWED BY:JIMMY METERI DATE:11.272015 CORONA,CA 92079 REV.# BY DATE DESCRIPTION namasb6 DWG TITLE: PAGE#: SCALE: SO t SITE LOCATION: g571&a,CO 304 INDIVIDUAL 28903 SKYLARK STREET BDW3.4C08030q PLOT PLAN 2 NTS ELECTRICAL MENIFEE,CA 303.447.0300 STRUCTURAL NOTES: SOLAR CONTRACTOR- D ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS.TO MAXIMUM EXTENT POSSIBLE. 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. -p RTM 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION MANUAL.VERSION 227.3.PUB 140113-ICC.JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(11 SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21)BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. ROOFING CONTRACTOR- ' 17 DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE - APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT(I')OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF SAVE.PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SMALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. I to be a Pen 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE.BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO INSTALLATION. to ederalrs) ded lans mus ELECTRICAL NOTES: GENERAL- U ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 77 MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730. 8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED.FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 12OV BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SMALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING.BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT I}'. 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY: ANGELA BURKE DATE:11.25.20I MENIFEE HILLS LENNAR: 980 MONTECITO DRIVE,#302 REVIEWED BY:JIMMY METER DATE:1127.2015 CORONA,CA 92879 REV.# BY DATE DESCRIPTION tannasb6 ao�•e DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 4571 8 Street PLOT PLAN 3 NTS 28903 SKYLARK STREET Bo3 der.D3.4 CO 80304 NOTES MENIFEE,CA 03.447.0300 CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. ;Iran PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER fl MAIN SERVICE PANEL (VERIFIED BY BUILDER) SOLADECN WIRE TRANSITION BOX (UNDER ARRAY) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP 1-877-SLR-POWR PV POWER SOURCE - AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: im A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION ORIGINAL BY: ANGELA BURKE DATE:11.25.2015 MENIFEE HILLS LENNAR: REVIEWED BY:JIMMY METER DATE:11.27.2015 CO NA,CA 92 DRIVE,#302 CORONA,CA 92879 REV.# BY DATE DESCRIPTION namaste BOLA. DWG TITLE: PAGE#: I SCALE: SITE LOCATION: 4571 Broadway CO Street INDIVIDUAL MENIF SKYLARK.STREET Boulder, 7. 30004 PLOT PLAN 4 NTS MENIFEE,CA PLACARDS 303.447.0300