PMT16-01962 City of Menifee Permit No.: PMT16-01962
29714 HAUN RD.
'C—ACCEL/k�. MENIFEE, CA 92586 Type: Residential Electrical
`'""'"„'"""'"— MENIFEE Date Issued: 07/22/2016
PERMIT
Site Address: 30191 MUIRLANDS DR, MENIFEE,CA Parcel Number: 364-370-060
92584 Construction Cost: $6,943.00
Existing Use: Proposed Use:
Description of SOLAR TR 30422-3 CAMELLIA
Work: 10 MODULES 2.65KW
LOT 161
Owner Contractor
LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC
980 MONTECITO DR#302 25 ENTERPRISE
CORONA,CA 92879 ALISO VIEJO,CA 92656
Applicant Phone:9493498269
JEREMIAH ACAYTURRI License Number:728102
LENNAR HOMES OF CALIFORNIA INC
25 ENTERPRISE
ALISO VIEJO, CA 92656
Fee Description 01rt Amount 151
Solar,Residential or Small Commercial 1 252.00
Building Permit Issuance 1 27.00
GREEN FEE 1 1.00
SMIP RESIDENTIAL 1 1.00
General Plan Maintenance Fee-Electrical 1 12.60
$293.60
The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and
specifications or from preventing builiding operations being carded on thereunder when in violation of the Building Code or of any other
ordinance of City of Menifee.Except as otherwise stated,a permit for construction under which no work is commenced within six
months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be
forfeited.
AA_Bldg_Pennit_Template.rpt Page 1 of 1
BUILDING & SAFETY • APPLICATION
Menifee
DATE 0 6/1 512 0 1 6 PERMIT/PLAN CHECK NUMBER Phil to/O'_ (031,
TYPE: ❑COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILE HOME ❑POOL/SPA ❑SIGN
SUBTYPE: ❑✓ ADDITION [—]ALTERATION [—]DEMOLITION ❑ELECTRICAL ❑MECHANICAL
❑NEW ❑PLUMBING ❑RE-ROOF-NUMBER OF SQUARES
DESCRIPTION OF WORK Solar Permit-Plan 2077-2.65 kW/ 10 PCS
Master Solar Permit: PMT14-02630
PROJECT ADDRESS 30191 Muirlands Dr.,Menifee, CA 92584
ASSESSOR'S PARCEL NUMBER 364-370-060 LOT 161 TRACT 30422-3
PROPERTY OWNER'S NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr.,Suite 302, Corona,CA 92879
PHONE (951)817-3680 EMAIL leremlah.acayturri@lennar.com
APPLICANT NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879
PHONE (951)817-3680 EMAIL leremiah.acayturri@lennar.com
CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? ❑✓ YES❑NO
BUSINESS NAME Lennar Homes of California, Inc.
ADDRESS 980 Montecito Dr., Suite 302, Corona,CA 92879
PHONE (951)817-3680 EMAIL Jeremiah.acayturri@lennar.com
CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B
VALUATION$ $6,943.00 L SO FT
APPLICANT'S SIGNATURE DATE 06/15/2016
CITY STAFF USE ONLY
DEPARTMENT DISTRIBUTION M CITY OF MENIFEE BUSINESS LICENSE NUMBER
BUILDING PLANNING ENGINEERING FIRE GREEN SMIP I v
INVOICE M PAID AMOUNT AMOUNT 0CASH OCHECK# 0CREDIT CARD VISA/MC
PLAN CHECK FEES PAID AMOUNT 0CASH 0CHECK# 0 CREDIT CARD VISA/MC
OWNER BUILDER VERIFIED OYES O NO DLNUMBER NOTARIZED LETTER O YES O NO
City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777
www.citycfinenifee.us Inspection Request Line 951-246-6213
SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED
ITEM OTY MFR. MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE
SYSTEM SIZE 2.65 KW LOCATIONS INDICATED BY THE ILLUSTRATION.
MODULE 10 PCS. HYUNDAI HIS-SZ65RG(265W) BUYER:
INVERTER IO PCSJ ENPHASE I M215-60-2LL-S22-IG
ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE:
SUB-ARRAY INFORMATION
ARRAY#1 ARRAY#2 1 ARRAY#3
MOD OTY IO NA NA BUYER:
ILT 23• 1 [a. I NA- City of Menifee DATE: tiI t OF ENI
AZIMUTH 1 270• 1 NA- I NA- Building Dept
WING AN
JUN 13 YC' Mike DufBpl1 N Ap R0%.� Sr VPOperations
uc#1001133 Class R
Receiv `A REVIEWED
16'-5"ARRAY
IT-3'FLASHING 20'-A&" Approval of thes plans
approval of,any v olation
— regulations and oi dinancf
jobsite until comp etion.
9
I I
SOLADECK WIRE
TRANSITION BOX
(UNDER ARRAY) I
I I
PV AC DISCONNECT i
EXTERIOR-GARAGE I
I i
UTILITY METER 6
MAIN SERVICE PANEL-1-4 -—
(VERIFIED BY BUILDER)
I I
NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF
®Z
PLAN 2077 ELEVATION C
ORIENTATION 4 LOT#161
LENNAR: ORIGINAL BY: GREG WONG I DATE:16.04.I3
CAMELLIA AT 980 MONTECITO DRIVE,#302 REVIEWED BY:SHAUN MARUNA I DATE:16.04.13
THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION
;2mamae,M.
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571E roadway Street
INDIVIDUAL 30191 CA NDS DRIVE BONtle4 00304
PLOT PLAN I/16'= I'-0' MENIFEE.EE,U 303.447.0300
SYSTEM LAYOUT
MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS
ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL
LOCATION MENIFEE.CA INV.MAKE INVERTER SPEC ENPHASE
TEMP.AMBIENT HIGH(TMAX) ASHRAE 2% °C 37 INV.MODEL INVERTER SPEC M215-60-2LL-S22-IG
TEMP,AMBIENT LOW(TMIN) ASHRAE EXTR.MIN °C -2 INV.MAX POWER.MAC MAX) INVERTER SPEC WATTS(AC) 225
TEMP.MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V,(VDC MAX) INVERTER SPEC VOLTS(DC) 48
TEMP,DELTA LOW(TDELTA) TMIN-TTEST °C -27 INV.OUTPUT V,(VAC NOM) INVERTER SPEC VOLTS(AU 240
MOD. MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FREQUENCY INVERTER SPEC HERTZ 60
MOD. PART NUMBER MODULE SPEC HIS-S265RG INV.OUTPUT CURRENT,IAC INVERTER SPEC AMPS(AC) 0.9
MOD. POWER STC(P) MODULE SPEC WATTS(DC) 265 INV.PHASE QUANTITY INVERTER SPEC PHASE I L
MOD.POWER PTC MODULE SPEC WATTS(DC) 238 COMPLIANCE INVERTER SPEC UL1741/1EEE1547 "
MOD.OPERATING VOLTAGE(VMP) MODULE SPEC VOLTS(DC) 31.30 INV. GROUNDING INVERTER SPEC ISOLATED ���
MOD.OPEN CCT.VOLTAGE(VOC) MODULE SPEC VOLTS(DC) 38.10 INV.CITY,MAX/BRANCH CCT. INV.GTYac OTY I0 J
MOD.COEFF.VOLT/TEMP(COEF) MODULE SPEC V/°C -0.114 BRANCH CCT. OUTPUT,IMAXBC I (IAC-INV.QTYBC) I AMPS(AC) 19.00
MOD. MAX VOLTAGE(VFIAXMDD) (VOG♦(TO°COEF)) VOLTS(DC) 41.18 INV.QUANTITY.TOTAL I INV.QTYT I OTY 110
MOD.OPERATING CURRENT(IMP) MODULE SPEC AMPS(DC) 8.50 TOTAL SYSTEM OUTPUT,IMAxTS (IAC°INV.QTYT) I AMPS(AC) 19.00
MOD.SHORT CCT. CURRENT(ISU MODULE SPEC AMPS(DC) 9.00
MOD.MAXIMUM CURRENT(IMAX) (ISC• 1.25) AMPS(DC) 11.25
MIN.AMPACITY REO'D.PER NEC (TMAX' 1.25) AMPS(DC) 14.06
SERIES FUSE RATING,MAX MODULE SPEC AMPS(DC) 15
ELECTRICAL EQUIPMENT SCHEDULE
KEY CITY MANUFACTURER MODEL I NOTES TRADE °
1 10 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR
2 ID ENPHASE M215-60-2LL-S22-IG PVINVERTER SOLAR IP
3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA SIR SOLAR he con
4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT.NEMA 3R,24OV,30A SOLAR �q rovislot
5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR
6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR This iet of al
7 1 TBD TBD CAT5 PORT FOR SOLAR PV INTER14ET CONNECTION TO HOME NETWORK BOX SOLAR
8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS;1 X 15A-IP(ENVOY) SOLAR
9 NOTE CUTLER-HAMMER TBD PV BREAKER,I x 2OA-2P.LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR
10 I TBD TBD SERVICE PANEL,MIN. 125A BUS BLDR.ELEC.
II I TBD TBD UTILITY METER.IPH,I20/240V,200A BLDR.ELEC.
12 1 I 1 TBD I TBD I GROUNDING ELECTRODE LIFER BLDR.ELEC.
CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS
U CONDITION OF USE(COU): (AMPACITY•TEMP.DERATE° FILL DERATE)VS. REQ'D(IMAX) ITEM UNIT PANEL
2)TERMINALS(TERM): AMPACITY AT TERMINALS.VS. REO'D.(IMAX• 1.25) PANEL HER. CUTLER-HAMMER
KEY SIZE LU/AL INSULATION CALC. AMPACITY W/O TEMP. FILL RESULT REO'D OCD BUS RATING AMPS 200
TYPE DERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT AMPS 200
A #12 CU THWN-2 COU 30 0.76 1.0 1 22.80 9.00 ALLOWED PV PER NEC AMPS 40
TERM 25 1 25 11.25 20 PV OCPD DEVICE USED AMPS 20
B #10 Cu NM-B COU 40 0.91 1.0 36.40 9.00
TERM 35 35 11.25 20 .��\�
C #10 1 CU I NM-B COU 40 0.91 1 1.0 36.40 9.00 Mike DUfaUlt
TERM 35 35 11.25 20
CONDUCTOR SCHEDULE 5F Licit
0 1001133 oCs
k 333 Class B
KEY CONDUCTORS CU/AL TYPE LOCATION TRADE
A I-#12 ENGAGE CABLE. 1460.FREE AIR I CU I TC-ER I ARRAY I SOLAR
B I 3-#10,I-#10 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR
C 1 3-#10,1410 EGC I CU I NM-B(ROMEX) I INTERIOR I SOLAR
D CAT5E.ETHERNET CABLE CU CA75E INTERIOR I SOLAR
5 6 It
7 • o I O_
SEE NOTE 15 QQ
B
isviF
O
'N
G
G
A B C
ROOF EXTERIOR-GARAGE
ELECTRICAL DIAGRAM 2.65 XW
LOT#161
ORIGINAL BY: GREG WONG DATE:16.04.13
CAMELLIA AT LENNAR:
980 MONTECITO DRIVE,#302 REVIEWED BY:SHAUN MARUNA I DATE:16.04.13
THE LAKES CORONA,CA 92879 REV.# BY DATE I DESCRIPTION •,
namastA
SOIX•
DWG TITLE: PAGE#: SCALE: SITE LOCATION:
tmot
INDIVIDUAL 4571&DB-- 304
PLOT PLAN 2 NTS 3019I MUIRLANDS DRIVE BDutle4 7030309
ELECTRICAL MENIFEE.CA 3033.497.0300
STRUCTURAL NOTES:
SOLAR CONTRACTOR- Mike Dufault
D ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. Sr VP Operations
2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. LlC#1001133 Class B
3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT.
4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED.
5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE.
6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CDDE-COMPLIANT INSTALLATION
MANUAL.VERSION 227.3,PUB 140113-ICC,JANUARY 2DI4.
7)UNIRAC TOP CLAMPS REQUIRE A ONE INCH(1')SPACE BETWEEN PV MODULES. SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND THE EDGE
OF THE PV ARRAY 7 SUB-ARRAY.
B)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. //LL f
ROOFING CONTRACTOR- ) PAR 1
1)DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'.
2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL-TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE
APROVED PRIOR TO PV SYSTEM INSTALLATION.
3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT 00 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE,DOWN TO THE ROOF EAVE.PEEL-N-STICK BASE TO `
BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS.
4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE. COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE.
5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS.
6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE.BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO
INSTALLATION. �—
O6eapf
lL federal,
ved plans ml
ELECTRICAL NOTES:
GENERAL-
D ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL).
2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC.
3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC
WELD.
4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING.NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE
MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED.
5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE.
6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE.
SOLAR CONTRACTOR-
7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730.
8)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS.
9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS.OF WATER AND INSECTS,
10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM.
11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE
ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER.
12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122.
13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING.OR MANUFACTURER'S RECOMMENDATIONS.
14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT.
15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR.
SIGNAGE-
16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES.
17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS.
M)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF
MINIMUM HEIGHT J'.
19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED"PHOTOVOLTAIC POWER SOURCE;OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'.
BUILDER ELECTRICAL AND SOLAR CONTRACTORS-
20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER.
20 SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26.
ORIGINAL BY: GREG WONG DATE:16-0 .
LENNAR: 13
CAMELLIA AT REVIEWED BY:SHAUN MARUNA I DATE:16.04.13
980 MONTECITO DRIVE,#302
THE LAKES CORONA,CA 92B79 REV.# BY DATE DESCRIPTION •�
namasbB
SOLAS
DWG TITLE: PAGE#: SCALE: SITE LOCATION:
treet
INDIVIDUAL _ 4571 BroaCO 304
PLOT PLAN 3 KITS 30191 EE.C ANDS DRIVE Boulder, 030004
NOTES MENIFEE.CA 303.447.0300
Mike Dufaul[
Sr VP Operations
Lid 1001133 Class B
CAUTION:
POWER TO THIS BUILDING IS SUPPLIED BY THE
UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS
ARE LOCATED AS SHOWN. I��J'
pqpo
DATE
a;or an
e or city
le kept on t
SOLADECK WIRE
TRANSITION BOX
(LINDER ARRAY)
PV AC DISCONNECT
EXTERIOR-GARAGE
LMUTY METER&
MAIN SERVICE PANEL
(VERIFIED BY BUILDER)
SERVICE BY QUALIFIED PERSONNEL ONLY
CONTACT: SUNSTREET ENERGY GROUP
1-877-SLR-POWR
PV POWER SOURCE - AC SPECS
AC OPERATING VOLTAGE: 240 V
AC OPERATING CURRENT: 9.0 A
NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION
ORIGINAL BY: GREG WONG DATE:16.04.13
980 MDNTECITD DRIVE.#302
CAMELLIA AT LENNAR: REVIEWED BY:SHAUN MARUNA I DATE:16.D4.13
THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION
Vnamasr6
fOLAr
DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadway Street
INDIVIDUAL 30191 MUIRLANDS DRIVE Boulder,CO 80304
PLOT PLAN 4 NTS MENIFEE,CA 3D3.447-0300
PLACARDS