Loading...
PMT16-01961 City of Menifee Permit No.: PMT16-01961 29714 HAUN RD. Type: Residential Electrical 4ikCCEL/ MENIFEE,CA 92586 Cmm.-Fi S,dtrxr MENIFEE Date Issued: 0 7/2 212 01 6 PERMIT Site Address: 30203 MUIRLANDS DR, MENIFEE, CA Parcel Number: 364-370-059 92584 Construction Cost: $8,331.60 Existing Use: Proposed Use: Description of SOLAR TR 30422-3 CAMELLIA Work: 12 MODULES 3.18KW LOT 160 Owner Contractor LENNAR HOMES OF CA LENNAR HOMES OF CALIFORNIA INC 980 MONTECITO DR#302 25 ENTERPRISE CORONA, CA 92879 ALISO VIEJO,CA 92656 Applicant Phone:9493498269 JEREMIAH ACAYTURRI License Number:728102 LENNAR HOMES OF CALIFORNIA INC 25 ENTERPRISE ALISO VIEJO,CA 92656 Fee Description OQl( Amount($1 Solar, Residential or Small Commercial 1 252.00 Building Permit Issuance 1 27.00 GREEN FEE 1 1.00 SMIP RESIDENTIAL 1 2.00 General Plan Maintenance Fee-Electrical 1 12.60 $294.60 The issuance of this permit shall not prevent the building official from thereafter requiring the correction of errors in the plans and specifications or from preventing builiding operations being carried on thereunder when In.violation of the Building Code or of any other ordinance of City of Menifee.Except as otherwise stated,a permit for constructlon under which no work is commenced within six months after issuance,or where the work commenced is suspended or abandoned for six months,shall expire,and fees paid shall be forfeited. AA_Bldg_Permil_Template.rpt Page 1 of 1 BUILDING & SAFETY PERMIT/PLANAPPLICATION - r-. , Menif1 ee DATE 06/15/2016 PERMIT/PLAN CHECK NUMBER TYPE: []COMMERCIAL ❑✓ RESIDENTIAL ❑MULTI-FAMILY ❑MOBILEHOME POOL/SPA []SIGN SUBTYPE: ❑✓ ADDITION []ALTERATION []DEMOLITION []ELECTRICAL []MECHANICAL ❑NEW ❑PLUMBING ❑RE-ROOF-NUMBER OF SQUARES DESCRIPTION OF WORK Solar Permit-Plan 2785-3.18 kW/12 PCS Master Solar Permit: PMT14-02630 PROJECT ADDRESS 30203 Muirlands Dr., Menifee, CA 92584 ASSESSOR'S PARCEL NUMBER 364-370-059 LOT 160 TRACT 30422-3 PROPERTY OWNER'S NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona, CA 92879 PHONE (951)817-36BO EMAIL Jeremiah.acayturri@lennar.com APPLICANT NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302,Corona,CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S NAME Lennar Homes of California, Inc. OWNER BUILDER? ❑✓ YES❑NO BUSINESS NAME Lennar Homes of California, Inc. ADDRESS 980 Montecito Dr.,Suite 302, Corona, CA 92879 PHONE (951)817-3680 EMAIL jeremiah.acayturri@lennar.com CONTRACTOR'S STATE LIC NUMBER 728102 LICENSE CLASSIFICATION A&B VALUATION$ $8.331.60 S LSQFT APPLICANT'S SIGNATURE DATE 06/15/2016 CITY STAFF USE ONLY DEPARTMENT DISTRIBUTION p CITY OF MENIFEE BUSINESS LICENSE NUMBER BUILDING PLANNING ENGINEERING FIRE GREEN ( SMIP INVOICE qq. PAIDAMOUNT AMOUNT O��l O CASH O CHECK q O CREDITCARD VISA/MC PLAN CHECK FEES PAID AMOUNT OCASH OCHECKH 0CREDITCARD VISA/MC [OWNER VERIFIED OYES O NO - DL NUMBER NOTARIZED LETTER O YES O NO City of Menifee Building&Safety Department 29714 Haun Rd. Menifee, CA 92586 951-672-6777 www.cityofinenifee.us Inspection Request Line 951-246-6213 SYSTEM INFORMATION BUYER ACKNOWLEDGES THAT THE SOLAR MODULES TO BE INSTALLED ITEM OTY MFR. 1 MODEL ON THE ROOF OF THE HOME WILL BE SUBSTANTIALLY IN THE SYSTEM SIZE 3.18 KW I LOCATIONS INDICATED BY THE ILLUSTRATION. MODULE 12PCS.1 HYUNDAI I HIS-S265RG(265W) BUYER: INVERTER 12 PCS. ENPHASE M215-60-2LL-S22-IG ROOF TYPE I TILE W/COMPOSITE SHINGLE UNDER ARRAY DATE: �J SUB-ARRAY INFORMATION .i r01 101 ARRAY#I 1 ARRAY#2 1 ARRAY#3 �,1'��' MOD OTY 12 NA NA BUYER: TILT 1 23° 1 NA' I NA' AZIMUTH 1 270° 1 NA' I NA' City of men l DATE:__=:M,,kl PR Building DeptJUN 13 ZCiS Re c Is iv 4aproval of th se I pa '),proval of,an violati 19'-9'ARRAY regl;lations and 6'-6.Xe' 20'-7-FLASHING rdinar Inb'itauntilcon I;tion --——— —— — -—————— ---� I I - I I I I I I I I I I r ———J I SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) I I VN—— I PV AC DISCONNECT + —J I EXTERIOR-GARAGE UTILITY METER 6 MAIN SERVICE PANEL -------- --------J (VERIFIED BY BUILDER) `e V NOTE:DIMENSIONS ARE SHOWN IN PLANE OF ROOF PLAN 2785 ELEVATION B-REV RSE ®Z ORIENTATION 4 LOT# CAMELLIA AT LENNAR: ORIGINAL BY: GREG WONG I DATE:16.04.13 980 MONTECITO DRIVE.#302 REVIEWED 8Y:SHAUN MARUNA I DATE:16.04.13 THE LAKES CORONA,CA 92879 REV.# BY DATE I DESCRIPTION namast6 DWG TITLE: PAGE#: SCALE: SITE LOCATION: SOLAR INDIVIDUAL 4571 Broadway Street PLOT PLAN 1 1/16-= 1'-0' 3D203 MUIRLANDS DRIVE Boultler,CO B0304 SYSTEM LAYOUT MENIFEE,CA 303.447.0300 MODULE SPECS AND CALCULATIONS INVERTER SPECS AND CALCULATIONS ITEM NOTE/CALC UNIT DETAIL ITEM NOTE/CALC UNIT DETAIL LOCATION MENIFEE.CA INV. MAKE INVERTER SPEC ENPHASE TEMP,AMBIENT HIGH(TMAX) ASHRAE 2% 'C 37 INV. MODEL INVERTER SPEC MZ15-60-2LL-S22-IG TEMP,AMBIENT LOW(THIN) ASHRAE EXTR.MIN 'L -2 INV.MAX POWER,(WAG MAX) INVERTER SPEC WATTS(ac) 225 TEMP,MODULE TEST(TTEST) MODULE SPEC °C 25 INV. INPUT V.(VDC MAX) INVERTER SPEC VOLTS(Oc) 48 TEMP,DELTA LOW(TOELTA) TMIN-TTEST °C -27 INV.OUTPUT V,(VAC NOM) INVERTER SPEC VOLTS(AD) 24D I MOD.MANUFACTURER MODULE SPEC HYUNDAI INV.OUTPUT FRECUENCY INVERTER SPEC HERTZ 60 MOD.PART NUMBER MODULE SPEC HIS-S265RG INV.OUTPUT CURRENT.IAC INVERTER SPEC AMPS(AC) 0.9 �ET MOD.POWER STC(P) MODULE SPEC WATTS(0c) 265 INV.PHASE DUANTITY INVERTER SPEC PHASE I 1 MOD.POWER PTC MODULE SPEC WATTS(Dc) 239 COMPLIANCE INVERTER SPEC UL1741/IEEEI5 MOD.OPERATING VOLTAGE(VMF) MODULE SPEC VOLTS(oc) 31.30 INV.GROUNDING INVERTER SPEC DILATED MOD.OPEN CCT.VOLTAGE(Voc) MODULE SPEC VOLTS(oc) 38.10 INV.OTY.MAX/BRANCH CCT, INV.QTYBc QTY 12 MOD.COEFF.VOLT/TEMP(COEF) MODULE SPEC V/°C -0,114 BRANCH CCT.OUTPUT, IMAXBC UAc'HNV.QTY80 I AMPS(AC) I 1D.80 MOD.MAX VOLTAGE(VMAXMOD) (VOD 4(TD-COEF)) VOLTS(oc) 41.18 INV.QUANTITY,TOTAL INV.QTYT QTY 12 MOD.OPERATING CURRENT(IMP) MODULE SPEC AMPS(Dc) B.50 TOTAL SYSTEM OUTPUT.IMAXTS (IAC'INV.QTYT) AMPS(ac) 10.80 MOD.SHORT CCT. CURRENT(Isc) MODULE SPEC AMPS(DO 9.00 MOO.MAXIMUM CURRENT(IMAX) (Isc• 1.25) AMPS(DU 11.25 MIN.AMPACITY REO'D,PER NEC (IMAX' 1.25) AMPS(oc) 14.06 ° SERIES FUSE RATING,MAX MODULE SPEC AMPS(oc) 15 ELECTRICAL EQUIPMENT SCHEDULE noi be con: KEY QTY MANUFACTURER MODEL NOTES TRADE 1 12 HYUNDAI HIS-S265RG(265W) PV MODULE SOLAR �any Ovlslon 2 12 ENPHASE M215-60-2LL-S22-IG PV INVERTER SOLAR Thist of ap 3 1 RSTC/SOLADECK 0786-3R5 PV ROOF JUNCTION BOX,NEMA 3R SOLAR 4 1 CUTLER-HAMMER DG221URB PV AC DISCONNECT,NEMA 3R,240V,30A SOLAR 5 1 ENPHASE ENVOY PV DATA MONITOR,120V SOLAR 6 1 TBD TBD 120V DEDICATED RECEPTACLE FOR ENVOY PV DATA MONITOR SOLAR 7 1 TBD TBD CATS PORT FOR SOLAR PV INTERNET CONNECTION TO HOME NETWORK BOX SOLAR 8 NOTE CUTLER-HAMMER TBD PV BRANCH CIRCUIT BREAKERS;I X 15A-IP(ENVOY) SOLAR 9 NOTE CUTLER-HAMMER TBD PV BREAKER,I x 20A-2P,LOCATE AT OPPOSITE END OF BUS FROM MAIN BREAKER SOLAR 10 I TBD BD SERVICE PANEL,MIN. 125A BUS BLDR.ELEC. 11 TBD T TBD 1 UTILITY METER,IPH,120/240V.200A BLDR.ELEC. 12 1 1 1 TBD I TBD I GROUNDING ELECTRODE UFER BLDR.ELEC. CONDUCTOR SIZING CALCULATIONS INTERCONNECTION CALCULATIONS O CONDITION OF USE(COU): (AMPACITY•TEMP.DERATE• FILL DERATE)Vs.REQ'D(IMAX) ITEM UNIT PANEL 2)TERMINALS(TERM): AMPACITY AT TERMINALS.vs. REO'D,(IMAX• 1.25) PANEL MFR. CUTLER-HAMMER KEY SIZE LU/AL INSULATION CALL. AMPACITY W/D TEMP. FILL RESULT REO'D OCD BUS RATING AMPS 200 TYPE OERATES DERATE DERATE (A) (A) USED(A) MAIN DISCONNECT I AMPS 20D A #12 CU THWN-2 COU 30 0.76 1.0 22.80 10.BO ALLOWED PV PER NEC AMPS 40 TERM 25 25 13.50 20 py OLPD DEVICE USED AMPS 20 B #10 CU NM-B CCU 40 0.91 1.0 36.40 10.80 TERM 35 35 13.50 20 "^�� C #10 CU NM-B COU 40 0.91 1.0 36.40 10.80 Mike DUfaQI[ TERM 35 35 1 13.50 20 CONDUCTOR SCHEDULE Llcg ID01 133 Cs ic# 133 Class B KEY CONDUCTORS CU/AL TYPE LOCATION TRADE A 1NGAGE CABLE, 1-#6G,FREE AIR CU TC-ER ARRAY SOLAR B 3-1-#2 E#10.1-#10 EGG CU I NM-B(ROMEX) INTERIOR SOLAR C 3-#10.1410 EGC CU I NM-B(ROMEX)I INTERIOR SOLAR D I CAT5E.ETHERNET CABLE I CU I CATSE JINTERIOR SOLAR 5 6 11 7 • o 0 � M - SEE NOTE 15 10 O ISMS, 0 9 O2b1/ 3 N G G ROOF EXTERIOR-GARAGE ELECTRICAL DIAGRAM 3.18Xw LOT#160 ORIGINAL BY: GREG WONG I DATE:16.04.13 CAMELLIA AT LENNAR: 980 MONTECITO DRIVE,#302 REVIEWED BY:SHAUN MARUNA DATE:16.04.13 THE LAKES CORONA.CA 92879 REV.# BY DATE DESCRIPTION namast;6 SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: Streiat INDIVIDUAL 457T BIOaCO8 PLOT PLAN 2 NTS 30203 MUIRLANDS DRIVE BOWOe4 703004 3 04 ELECTRICAL MENIFEE,CA 303. 47.0300 STRUCTURAL NOTES: SOLAR CONTRACTOR- Mike Dufault D ALL PV ROOF ATTACHMENTS WILL BE SPACED ALONG MODULE RACKING RAILS AT NOT GREATER THAN 48'O.C. Sr VP Opet3tions 2)ALL PV ROOF ATTACHMENTS WILL BE STAGGERED BY ROW AMONGST THE ROOF FRAMING MEMBERS,TO MAXIMUM EXTENT POSSIBLE. Lic#1001133 Class B 3)ROOF PENETRATIONS ASSOCIATED WITH SOLAR RACKING WILL BE SEALED WITH AN APPROVED SEALANT. 4)SOLADECK WIRE TRANSITION BOX WILL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. IT WILL BE FLASHED AND SEALED. 5)PV ARRAY WILL BE A MINIMUM OF 3'ABOVE THE COMPOSITE SHINGLE ROOF SURFACE. 6)THE UNIRAC SOLARMOUNT RACKING SYSTEM AND SOLAR PV ARRAY WILL BE INSTALLED ACCORDING TO THE UNIRAC SOLARMOUNT CODE-COMPLIANT INSTALLATION pgRl MANUAL.VERSION 227.3,PUB 140113-ICC,JANUARY 2014. 7)UNIRAC TOP CLAMPS REQUIRE'A ONE INCH(1')SPACE BETWEEN PV MODULES.SOLARMOUNT RAILS MUST EXTEND A MINIMUM OF TWO INCHES(21 BEYOND THE EDGE OF THE PV ARRAY/SUB-ARRAY. 8)UNIRAC SOLARMOUNT REQUIRES THAT A THERMAL EXPANSION GAP BE INSTALLED FOR ANY RAIL LENGTH OF GREATER THAN 40'. ROOFING CONTRACTOR- U DISTANCE BETWEEN ARRAY EDGE AND TRANSITION FLASHING(COMPOSITION TO TILE)WILL BE A MINIMUM OF 3'. 2)26 GAUGE INTERLOCKING FLASHING'SIDEWALL'TO BE INSTALLED ALONG THE LENGTH OF THE PV ARRAY AT ROOFING MATERIAL TRANSITION. IT SHALL BE APROVED PRIOR TO PV SYSTEM INSTALLATION. 3)PEEL-N-STICK BASE TO BE INSTALLED ONE FOOT 00 OR MORE BEYOND THE EDGE OF THE COMPOSITION SHINGLE.DOWN TO THE ROOF EAVE. PEEL-N-STICK BASE TO BE INSTALLED PER MANUFACTURER'S SPECIFICATIONS. 4)AREAS UNDER EACH PV ARRAY SHALL BE ROOFED WITH COMPOSITION SHINGLE.COMPOSITION SHINGLE SHALL RUN FROM ABOVE THE PV ARRAY TO THE ROOF EAVE. 5)TILE INSTALLED BELOW THE ARRAY TO BE INSTALLED ABOVE THE COMPOSITION ROOF PER ROOFER SPECIFICATIONS. 4 6)BIRDSTOP WILL BE INSTALLED AT THE UPPERMOST TRANSITION FROM TILE TO COMPOSITION SHINGLE. BIRDSTOP TO BE SPECIFIED BY ROOFER PRIOR TO •40 be a INSTALLATION. P e federal pans m ELECTRICAL NOTES: GENERAL- n ALL PV EQUIPMENT WILL BE TESTED AND LISTED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING LABORATORY(NRTL). 2)THE GROUNDING OF THE PHOTOVOLTAIC SYSTEM SHALL COMPLY WITH THE APPLICABLE VERSION OF THE NEC/CEC. 3)ALL GROUNDING ELECTRODE CONDUCTORS WILL BE INSTALLED IN A CONTINUOUS LENGTH EXCEPT WHERE SPLICED BY AN IRREVERSIBLE CONNECTOR OR EXOTHERMIC WELD. 4)NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING.,NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE ELECTRICALLY INSULATED BECAUSE OF PAINT/FINISH. PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED. 5)ROOF PENETRATIONS WILL BE COMPLETED AND SEALED PER APPLICABLE CODE. 6)ALL CONDUCTORS WILL HAVE A 90-C RATING TO ENSURE CODE COMPLIANCE. SOLAR CONTRACTOR- 7)MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730. B)CONDUIT AND CONDUCTOR SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS. 9)RACEWAY POINT OF PENETRATION FROM EXTERIOR TO INTERIOR WILL BE SEALED TO PREVENT INGRESS OF WATER AND INSECTS. 10)DC WIRING IS LIMITED TO PV ARRAY FOOTPRINT W/ENPHASE MICRO-INVERTER SYSTEM. 11)MODULE AND ENPHASE WIRING SHALL BE LOCATED AND SECURED UNDER THE ARRAY USING SUITABLE WIRING CLIPS.WIRING SHALL NOT MAKE CONTACT WITH THE ROOF SURFACE AND SHALL BE MANAGED IN A WORKMAN-LIKE MANNER. 12)EQUIPMENT GROUNDING CONDUCTORS WILL BE SIZED IN ACCORDANCE WITH NEC TABLE 250.122. 13)CONDUCTOR TERMINATIONS WILL BE TORQUED PER DEVICE LISTING,OR MANUFACTURER'S RECOMMENDATIONS. 14)A PV AGGREGATION PANEL(SUB PANEL)WILL NOT BE INCLUDED FOR SYSTEMS WITH ONE BRANCH CIRCUIT. 15)A DEDICATED 120V BRANCH CIRCUIT IS REQUIRED IN MASTER CLOSET(OR EQUIVALENT)FOR ENPHASE ENVOY MONITOR. SIGNAGE- 16)PV SYSTEMS SHALL BE CLEARLY MARKED IN ACCORDANCE WITH NEC ARTICLE 690 AND OTHER APPLICABLE STATE AND LOCAL CODES. 17)ALL SAFETY MARKING/PLACARDS SHALL BE PERMANENTLY ATTACHED BY ADHESIVE OR OTHER MECHANICAL MEANS. 18)MARKING/PLACARDS WILL BE METAL OR PLASTIC WITH ENGRAVED OR MACHINE PRINTED LETTERING. BACKGROUND WILL BE RED WITH WHITE CAPITAL LETTERING OF MINIMUM HEIGHT r. 19)ALL WIRING/RACEWAYS/JUNCTION BOXES WILL BE MARKED'PHOTOVOLTAIC POWER SOURCE:OR EQUIVALENT:WIRING/RACEWAYS SHALL BE MARKED EVERY 10'. BUILDER ELECTRICAL AND SOLAR CONTRACTORS- 20)INSTALLATION SHALL BE COMPLETED IN A NEAT AND WORKMAN-LIKE MANNER. 21)SPACE REQUIREMENTS FOR ALL ELECTRICAL EQUIPMENT WILL COMPLY WITH NEC ARTICLE 110.26. ORIGINAL BY: GREG WONG DATE:16.04.13 CAMELLIA AT LENNAR: REVIEWED BY:SHAUN MARUNA DATE: 04.15 980 MONTECITO DRIVE,#3D2If THE LAKES CORONA.CA 92879 REV.# BY DATE DESCRIPTION •� namast;6 DWG TITLE: PAGE#: SCALE: SITE LOCATION: INDIVIDUAL 45]1 Ber,CO 8 Street PLOT PLAN 3 NTS 30203 MUIRLANDS DRIVE Boulder,C08030q MENIFEE,CA 303.44].0300 NOTES Mike Dufault Sr VP Operations tit#1001133 Class B CAUTION: POWER TO THIS BUILDING IS SUPPLIED BY THE I NT UTILITY AND A SOLAR PV SYSTEM. DISCONNECTS ARE LOCATED AS SHOWN. 4' I` DATE or,or an or city LTkept on the SOLADECK WIRE TRANSITION BOX (UNDER ARRAY) PV AC DISCONNECT EXTERIOR-GARAGE UTILITY METER e NAIN SERVICE PANEL (VERIFIED BY BUILDER) SERVICE BY QUALIFIED PERSONNEL ONLY CONTACT: SUNSTREET ENERGY GROUP I-877-SLR-POWR PV POWER SOURCE — AC SPECS AC OPERATING VOLTAGE: 240 V AC OPERATING CURRENT: im A NOTE: SEE MASTER SET FOR ADDITIONAL PLACARD INFORMATION CAMELLIA AT LENNAR: ORIGINAL BY: GREG WONG I DATE:16.04.13 980 MONTEC1TO DRIVE.#302 REVIEWED BY:SMAUN MARUNA I DATE:16.04.13 THE LAKES CORONA,CA 92879 REV.# BY DATE DESCRIPTION %mclst;d SOLAR DWG TITLE: PAGE#: SCALE: SITE LOCATION: 4571 Broadwa 1 PLOT PLAN 4 NTS INDIVIDUAL 30203 MUIRLANDS DRIVEr= Boulder,CO 80304 PLACARDS I MENIFEE.CA 303.447.0300